首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A flow injection spectrophotometric method is proposed for the determination of bromoxynil herbicide. Bromoxynil was hydrolyzed with HCl and the resulting product, 3,5-dibromo-4-hydroxyaniline, was diazotized with nitrite and coupled with aniline. The absorbance of the azo dye was measured at 500 nm. The conditions were optimized for diazotization using FIA. The range of linearity was found to be 0.01 to 5 ppm with a molar absorptivity of 1.27 x 10(5) L mol(-1) cm(-1). The % recovery for the determination of bromoxynil was found to be 91%. The sampling frequency was 80 samples per hour for FIA. The method is simple, fast, and has been successfully applied to the determination of bromoxynil in commercial formulations and food samples.  相似文献   

2.
A spectrophotometric enzymatic flow injection (FI) system for the determination of diethyl-p-nitrophenylphosphate (paraoxon) is proposed. The method was based on the determination of the acetic acid formed by the enzymatic reaction of the acetylcholinesterase, immobilized on glass beads, with the substrate acetylcholine. The acetic acid formed permeates through a PTFE membrane and is received by a solution (pH 7.0) containing the acid-base indicator Bromocresol Purple (B.C.P.), leading to a pH change and therefore to a color change. The variation of the absorbance of the solution is detected spectrophotometrically at 400 nm. The determination of paraoxon is related to its inhibitory action on the enzyme. Therefore the analytical signal is the difference between the signal that corresponds to the free and the one that corresponds to the inhibited enzyme, considering a fixed acetylcholine concentration. The correlation between the peak height and paraoxon concentration at a given acetylcholine concentration is linear in the range from 5.0 x 10(-7) mol L-1 to 5.0 x 10(-5) mol L-1 (r = 0.998) of paraoxon, with a relative estimated standard deviation (R.S.D.) of +/- 1.7% (n = 10) considering a solution containing 5.0 x 10(-6) mol L-1 of paraoxon and a solution containing 5.0 x 10(-3) mol L-1 of acetylcholine. Therefore, the quantitative limit detection is about 2.5 x 10(-7) of paraoxon (3 sigma). A 1,1'-trimethylene-bis(4-formylpyridinium bromide)dioxime (TMB-4) solution was used to reactivate the enzyme.  相似文献   

3.
Wang S  Du L  Yao X  Niu X  Zhuang H 《Annali di chimica》2005,95(1-2):87-94
A novel kinetic spectrophotometric method is described for the determination of rutin. The method is based on the inhibitory effect of rutin on the oxidation reaction of amaranth by potassium periodate in acidic media at 100 degrees C. The linear range for the determination of rutin is 0.02 - 0.50 microg/ml, and the detection limit is 0.014 microg/ml. The method has been successfully applied to the determination of rutin in medicine of rutin tablet and traditional Chinese medicine.  相似文献   

4.
A simple, rapid, and economical spectrophotometric method is developed for the determination of sulfur dioxide in sugar and air samples. The developed method is based on a red-brown peroxovanadate complex (λmax = 470 nm) produced in 2 M sulfuric acid when ammonium metavanadate is treated with hydrogen peroxide. Under fixed concentrations of hydrogen peroxide and ammonium metavanadate, when sodium metabisulfite (Na2S2O5 = 2SO2) is added, it preferentially reacts with hydrogen peroxide producing sulfuric acid, and the unreacted hydrogen peroxide then reacts with ammonium metavanadate; therefore, the concentration of sulfur dioxide is directly proportional to a decrease in the concentration of the peroxovanadate complex. The stoichiometric ratio between hydrogen peroxide and ammonium metavanadate as well as the stability constant of the complex are determined by the modified Job’s method and the respective values are found to be 1: 1 and 2.5 × 104 mol−1 L, respectively. The system obeys Lambert-Beer’s law in the concentration range 3.57–64.26 ppm of sulfur dioxide. The molar absorptivity, correlation coefficient, and Sandell’s sensitivity values are found to be 0.649 × 103 L mol−1 cm−1, 0.9908, and 0.1972 μg cm−2, respectively. The method is applied to the determination of sulfur dioxide present in commercial sugars and air samples. The results obtained are reproducible with a standard deviation of 0.02–0.05. For method validation, sulfur dioxide is also determined separately following the AOAC method for an air sample and the ICUMSA method for commercial sugars. The results obtained by the developed and official methods are in good agreement. The text was submitted by the authors in English.  相似文献   

5.
A rapid, simple, and most economical spectrophotometric method was proposed for the determination of nitrite in various water samples, soil samples, and roots of leguminous plants. The method is based on decolorizing effect of nitrite on complex formed between hydrogen peroxide and vanadate in acidic medium. The decolorization of that complex by nitrite was exploited to monitor the reaction spectrophotometrically at 470 nm.The method was optimized for effect of concentrations of ammonium metavanadate, hydrogen peroxide, various acids, concentrations of sulphuric acid, order of reagents addition and color stability. The color of the complex was found to be stable for about 2 days, and the stability constant of the complex was also calculated by modified Job's method. The linearity range of the calibration graph was over 6.67-66.7 microg ml(-1) of nitrite with molar absorptivity, 0.276 x 10(3) mol(-1) l cm(-1) and Sandell's sensitivity, 0.1667 microg cm(-2). The method was applied successfully for the determination of nitrite in soil samples, various wastewater samples and roots of leguminous plants.  相似文献   

6.
A new catalytic kinetic spectrophotometric method for the determination of oxalic acid has been described based on its catalytic effect on the redox reaction between safranine and dichromate in dilute sulfuric acid media. The reaction is monitored photometrically by measuring the decrease in absorbance of safranine at the maximum wavelength of 530 nm. Under the optimum conditions, a calibration graph from 0.10 to 10.00 microg ml(-1) of oxalic acid with a detection limit of 0.08 microg ml(-1) was obtained. The relative standard deviation (R.S.D.) for ten replicate measurements of 1.0 and 5.0 microg ml(-1) oxalic acid was 2.7 and 2.5%, respectively. The purposed method is simple, sensitive, selective and inexpensive. The applicability of the proposed method was determined by the determination of oxalic acid in spinach and wastewater samples with satisfactory results.  相似文献   

7.
A kinetic spectrophotometric method for measuring thiocyanate is described. The proposed method is based on the inhibitory effect of thiocyanate on the oxidation of Methyl Red by bromate in the presence of nitrite, which was monitored at 520 nm. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. Thiocyanate can be measured in the range of 0.05-1.1 microg ml(-1) with a detection limit of 0.025 microg ml(-1). This method has been used to determine trace thiocyanate in urine and tap water samples.  相似文献   

8.
A kinetic spectrophotometric method for the determination of thiocyanate, based on its inhibitory effect on silver(I) catalyzed substitution of cyanide ion, by phenylhydrazine in hexacyanoferrate(II) is described. Thiocyanate ions form strong complexes with silver(I) catalyst which is used as the basis for its determination at trace level. The progress of reaction was monitored, spectrophotometrically, at 488 nm (λmax of [Fe(CN)5PhNHNH2]3?, complex) under the optimum reaction conditions at: 2.5 × 10?3 M [Fe(CN)6]4?, 1.0 × 10?3 M [PhNHNH2], 8.0 × 10?7 M [Ag+], pH 2.8 ± 0.02, ionic strength (μ) 0.02 M (KNO3) and temperature 30 ± 0.1 °C. A linear relationship obtained between absorbance (measured at 488 nm at different times) and inhibitor concentration, under specified conditions, has been used for the determination of [thiocyanate] in the range of 0.8–8.0 × 10?8 M with a detection limit of 2 × 10?9 M. The standard deviation and percentage error have been calculated and reported with each datum. A most plausible mechanistic scheme has been proposed for the reaction. The values of equilibrium constants for complex formation between catalyst–inhibitor (KCI), catalyst–substrate (Ks) and Michaelis–Menten constant (Km) have been computed from the kinetic data. The influence of possible interference by major cations and anions on the determination of thiocyanate and their limits has been investigated.  相似文献   

9.
Dominik P  Kaupenjohann M 《Talanta》2000,51(4):701-707
We describe a spectrophotometric method to determine the sum of Fe(II) plus Fe(III) in HCl and oxalate extracts. The principle of the method is to reduce Fe(III) by ascorbate in near-neutral solution and to sequester the Fe(II) formed as a tri-ferrozine complex, which is then determined photometrically at 562 nm. Because the complex is stable, the reaction is irreversible and complete. Fe(III) in HCl solution reacted very rapidly, whereas oxalate decelerated the overall reaction so that pseudo first-order kinetics with respect to Fe(III) was detected. However, when extractions were conducted at the recommended soil:solution ratio, the absorption reached 98% of its final value within a few minutes. To test the method, four soils differing considerably in texture and carbonate, organic matter, and Fe(III)(hydr)oxide contents were extracted with oxalate in the dark for amorphous (Fe(o)), and with boiling oxalate for total Fe(III)(hydr)oxide (Fe(bo)). This newly developed spectrophotometric method showed excellent correspondence with the conventional atomic absorption spectroscopy (AAS) method. The method presented here can therefore be used as an alternative method to determine the Fe content of oxalate and hydrochloric acid extracts if AAS is not available. Oxalate extracts low in Fe content, which cannot be diluted, are easier to determine by the photometric method than by AAS.  相似文献   

10.
A simple and sensitive flow injection method with spectrophotometric detection was developed for the determination of formaldehyde. The method is based on the catalytic effect of formaldehyde on the oxidation of sulfonazo III with bromate in acidic media. The decrease in absorbance of the reaction mixture was measured at 566 nm. The calibration graph was linear in the range of 0.005 to 2.80 microg ml(-1) formaldehyde at a rate of 38 +/- 4 samples h(-1). The limit of detection was 4 ng ml(-1). The relative standard deviations for ten replicate measurements of 0.20, 0.50 and 1.00 microg ml(-1) formaldehyde were 1.3, 0.8 and 0.7%, respectively. The method was applied to the determination of formaldehyde in river water, shampoo and melamine-formaldehyde resin.  相似文献   

11.
Summary When bentazone herbicide is injected into the gas-liquid chromatograph together with trimethylanilinium hydroxide, it reacts to yield a methylated derivative with good gas-chromatographic properties. This derivatization technique allows a rapid qualitative and quantitative chromatography of this pesticide. Standard deviations were about ±1%.  相似文献   

12.
偶氮胭脂红B动力学光度法测定Fe(III)   总被引:1,自引:0,他引:1  
动力学光度法测定铁[1,2]多用2,4 二氯苯酚+4 氨基安替比林[3]、苄橙[4]、次甲基蓝[5]、酸性铬蓝K[6]和二溴对甲基偶氮羧[7]等为监测组分,以H2O2为氧化剂,α,α 联吡啶为活化剂。本文用催化光度法确定铁(III)催化高碘酸钾氧化偶氮胭脂红B褪色反应的动力学条件及有关参数,仅以高碘酸钾为氧化剂,不使用活化剂,操作简单、快速,用于水样及生物样中铁的测定,结果满意。1 实验部分移取0 20mlFe(III)标准工作溶液(1 0μg/ml)于25ml比色管中,依次加入2 0ml0 02mol/L硫酸溶液,1 5ml0 010mol/L高碘酸钾溶液,1 5m…  相似文献   

13.
A catalytic for determination of nanomolar concentrations of Co(II), i.e., oxidation of -adrenaline hydrochloride with H2O2 in alkaline medium, is proposed. The reaction gives a low limit of detection of 2.5 × 10 −9 M Co(II) in the reaction mixture, good reproducibility with a relative standard deviation (R.S.D.) of 4−5% in the Co(II) concentration range 8.0 × 10−9−8.0 × 10−8M and good selectivity. On the basis of this indicator reaction, a catalytic-spectrophotometric method for the determination of cobalt in small urine samples (5.00 ml) was elaborated. The analysis of 17 urine samples, taken from healthy persons of different ages, gave cobalt concentrations in the range 0.20–1.50 μmol 1−1. The R.S.D. for ten replicate analyses of a urine sample with an average cobalt content of 0.63 μmol 1−1 was 5.6%. The reliability of the method was verified by a comparative photometric method (r = 0.9755) and by a determination based on known additions of cobalt (r = 0.9894).  相似文献   

14.
三甲氧基苯基荧光酮分光光度法测定锡的研究和应用   总被引:3,自引:0,他引:3  
研究了新显色剂三甲氧基苯基荧光酮分光光度测定锡的方法。在酸性介质中,表面活性剂吐温 40存在下,试剂与锡形成稳定的橙红色络合物,在510nm处具有最大吸收,其表观摩尔吸光系数ε510=1.48×105L·mol-1·cm-1,锡量在0~0 80μg mL范围内符合比尔定律。方法已应用于铝合金、碳素钢等样品中微量锡的测定。  相似文献   

15.
The present paper describes a simple, selective and sensitive kinetic method for the determination of trace amounts of molybdenum(VI) based on its inhibitory effect on the reaction oxidation of 4-hydroxycoumarine by KMnO(4) in the presence of hydrochloric acid, at pH 1.75 at 25 degrees C. The rate of the indicator reaction was followed spectrophotometrically by measuring the decrease in the absorbance of KMnO(4) at 525 nm. The development method includes optimization of the reagent concentration and temperature. The calibration graph was linear in the range of concentrations from 20 to 200 ng/cm(3) of molybdenum(VI). The probable relative error was in the interval 3.10 - 10.52% for the concentration range of 200 - 20 ng/cm(3) molybdenum(VI), respectively. The interference effects of the foreign ions were determined to assess the selectivity of the method. The developed method was found to have relatively good selectivity, sensitivity, simplicity and rapidity. The proposed method was applied to the determination of molybdenum(VI) in a particular type of steel and alloy (hastelloy).  相似文献   

16.
A simple kinetic spectrophotometric method was developed for the determination of ultratrace amounts of Se(IV). The method is based on the reduction of spadns by sulphide in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of spadns at 515 nm with a fixed-time method. The decrease in the absorbance of spadns is proportional to the concentration of Se(IV) in the range 0.5–100 ng/mL with a fixed time of 2.5–7.0 min from the initiation of the reaction. The limit of detection is 0.3 ng/mL Se(IV). The relative standard deviation for the determination of 0.02 and 0.10 μg/mL Se(IV) was 2.10 and 1.95%, respectively. The method was applied to the determination of Se(IV) in water. The text was submitted by the authors in English.  相似文献   

17.
研究了显色剂盐酸副玫瑰苯胺与Cr2O72 -的褪色反应.发现在H2SO4介质中盐酸副玫瑰苯胺与Cr(Ⅵ)反应具有高灵敏的褪色现象.据此建立了测定Cr(Ⅵ)的光度法.当Cr(Ⅵ)质量浓度为0.01~2.0 mg/L时,盐酸副玫瑰苯胺的吸光度与Cr(Ⅵ)浓度符合朗伯-比耳定律,摩尔吸光系数为5.9×105 L·mol-1·...  相似文献   

18.
19.
We report on a combination of magnetic solid-phase extraction and spectrophotometric determination of bromate. Cetyltrimethylammonium ion was adsorbed on the surface of phenyl-functionalized silica-coated Fe3O4 nanoparticles (Ph-SiO2@Fe3O4), and these materials served as the sorbent. The effects of surfactant and amount of sorbent, the composition of the desorption solution, the extraction time and temperature were optimized. Under optimized conditions, an enrichment factor of 12 was achieved, and the relative standard deviation is 2.9 % (for n?=?5). The calibration plot covers the 1–50 ng mL?1 range with reasonable linearity (r 2?>?0.998); and the limit of detection is 0.5 ng mL?1. The method is not interfered by ionic compounds commonly found in environmental water samples. It was successfully applied to the determination of bromate in spiked water samples.
Figure
Extraction of bromate ions using surfactant-coated phenyl functionalized Fe3O4 magnetic nanoparticles followed by spectrophotometric detection.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏