首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Little is known about melamine (MEL) analysis in children's urine. In this study, an isotopic ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and systematically validated for the analysis of MEL in urine. The method is easily performed and comprises acidification, solid‐phase extraction (SPE) and UPLC/MS/MS analysis. 13C3N3(15NH2)3 was used as the internal standard (IS) for calibration. Transition ions m/z 127 > 85 of MEL and m/z 133 > 89 of the IS were used for quantification and m/z 127 > 68 of MEL was used for quantitative confirmation. Recovery and precision were assessed to guarantee the applicability of the method. The limit of quantification (LOQ) was 0.01 µg/mL while the calculated method detection limit was 0.006 µg/mL. The mean recoveries ranged from 96–99%. The method was then applied to analyze urine samples from children who had potentially consumed MEL‐tainted dairy products during screening in Taiwan. Ten nephrolithiasis cases and 20 age‐ and gender‐matched controls were selected for this study. Three out of the 10 nephrolithiasis cases had elevated levels of MEL. Comparatively, twenty age‐ and gender‐matched non‐nephrolithiasis controls consuming Taiwan brand milk powder all showed MEL levels lower than the detection limit except for two children with background levels of 0.02 µg/mL. The background level in these children urine samples was established by UPLC/MS/MS analysis. Positive results of urine MEL tests might be associated with nephrolithiasis in these candidates. Measurement of urine MEL concentration can be helpful in confirming MEL‐related nephrolithiasis, but its clinical application needs further clarification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Dendrobine, considered as the major active alkaloid compound, has been used for the quality control and discrimination of Dendrobium which is documented in the Chinese Pharmacopoeia. In this work, a sensitive and simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method for determination of dendrobine in rat plasma is developed. After addition of caulophyline as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 (2.1 ×100 mm, 1.7 µm) column with acetonitrile and 0.1% formic acid as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 264.2 → 70.0 for dendrobine and m/z 205.1 → 58.0 for IS. Calibration plots were linear throughout the range 2–1000 ng/mL for dendrobine in rat plasma. The RSDs of intra‐day and inter‐day precision were both <13%. The accuracy of the method was between 95.4 and 103.9%. The method was successfully applied to pharmacokinetic study of dendrobine after intravenous administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive, rapid and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the determination of aristolochic acid‐I (AA‐I) in rat plasma. Finasteride was used as the internal standard (IS). The analyte was separated on a Zorbax Eclipse XDB‐C18 column by isocratic elution with methanol‐10 mM ammonium acetate (75:25, v/v, pH = 7.3) at a flow rate of 0.25 mL/min, and analyzed by mass spectrometry in positive multiple reaction monitoring mode. The precursor‐to‐product ion transitions of m/z 359.0 → 298.2 and m/z 373.1 → 305.2 were used to detect AA‐I and IS, respectively. Good linearity was achieved over a range of 0.4–600 ng/mL. Intra‐ and inter‐day precisions measured as relative standard deviation were less than 13.5%, and accuracy ranged from 94.2 to 97.5%. The developed method was successfully applied in the pharmacokinetic study of AA‐I in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A novel, rapid and sensitive isocratic liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for quantification of docetaxel in human plasma with paclitaxel as internal standard. The high sensitivity and specificity of MS/MS detection enabled the use of a small volume of plasma (0.05 mL) and a simple liquid-liquid extraction procedure. Furthermore, a very short run-time (3 min) fulfilled the need for monitoring plasma levels of docetaxel from large-scale clinical studies. The calibration curve for docetaxel was linear over the range 5-1000 ng/mL with coefficients of correlation >0.999 using only 0.05 mL plasma. The intra- and inter-day precisions (CV) of analysis were <7%, and accuracy ranged from 96 to 110%. The applicability of the method was demonstrated in a pharmacokinetic study of a 1-h infusion of docetaxel with dosages of 75 mg/m(2). Possible conjugated metabolites of docetaxel were not detected in patients' samples.  相似文献   

5.
An HPLC/MS/MS method for the determination of arbidol in human plasma was developed. Arbidol and internal standard (loratadine) were extracted from alkaline plasma with tert-butyl methyl ether and analyzed on a Zorbax SB C18 column (30 x 2.1 mm id, 3.5 microm particle size). The detection was by monitoring arbidol at m/z 479.1 --> 434.1 and the internal standard at m/z 383.2 --> 337.2. The method was validated according to U.S. Food and Drug Administration guidelines. The calibration curve was linear over the range of 0.5-500 ng/mL using a 100 microL sample volume. The intraday and interday precisions were less than 6.5%, and acceptable values were obtained for accuracy, recovery, and sensitivity. The developed method was selective, simple, sensitive, and easily applicable.  相似文献   

6.
A simple, sensitive and rapid ultra-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS) method has been developed and validated for the determination of lercanidipine in human plasma. Lercanidipine and the internal standard, nicardipine, were extracted from plasma by liquid-liquid extraction using tert-butyl methyl ether as the extraction solvent. UPLC analysis was performed isocratically on an AcQuity UPLC BEH C18 analytical column (2.1 x 50.0 mm i.d., particle size 1.7 microm). The mobile phase consisted of 70% acetonitrile in water containing 0.2% v/v formic acid and pumped at a flow rate of 0.30 mL/min. ESI in positive ion mode, with multiple reaction monitoring (MRM), was chosen for the detection of the analytes. The assay was linear over a concentration range of 0.05-30 ng/mL for lercanidipine with a limit of quantitation of 0.05 ng/mL. Quality control samples (0.05, 0.15, 15 and 25 ng/mL) in five replicates from five of analytical runs demonstrated intra-assay precision (% CV < or =7.3%), inter-assay precision (% CV < or =6.1%) and an overall accuracy (% relative error) of less than 6.2%. A run time of less than 1.0 min for each sample made it possible to analyze a large number of human plasma samples per day. The method can be used to quantify lercanidipine in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

7.
A novel method for the biological monitoring of benzene‐exposed workers has been developed through ultra‐performance liquid chromatography coupled to tandem mass spectrometry. The method uses trans,trans‐muconic acid in urine as the benzene‐exposure biomarker. The method was developed using a triple quadrupole mass spectrometer with enough sensitivity to facilitate diluting and injecting the urine samples directly, rather than performing a solid‐phase extraction procedure as is common in the available protocols. Moreover, compared with a conventional high‐pressure liquid chromatography system, the separation power provided by the ultra‐performance liquid chromatography system allows a 10‐fold reduction in run time. The method was adjusted to a dynamic range of between 198.9 and 4916.7 µg/L to cover the biological exposure index of trans,trans‐muconic acid in urine. Also, the method demonstrated intra‐day and inter‐day precision at 98%, and accuracy within an acceptable range of 101 ± 8%. The method has been used to quantify various types of urine samples, such as workers' urine and inter‐laboratory proficiency tests. Depending on the sample, the quantified levels ranged from less than the limit of quantitation to 3836.7 µg/L. No levels exceeding the calibration range were detected in the urine of workers, and the reported concentrations in urine for the proficiency tests were, as expected, based on known values. Moreover, the new method using sample dilution and faster chromatographic run was more effective, facilitating fast communication of results, as needed, to decision‐makers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and high sensitive ultra‐high‐performance liquid chromatography tandem mass spectrometry method for the determination of fludrocortisone in human plasma was developed and validated as per guidelines. The analyte and internal standard (IS), fludrocortisone‐d5, were extracted from human plasma via liquid–liquid extraction using tert‐butyl methyl ether. The chromatographic separation was achieved on a Chromolith RP18e column using a mixture of acetonitrile and 2 mm ammonium formate (70:30, v/v) as the mobile phase at a flow rate of 0.7 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in multiple reaction monitoring and positive ion mode. The precursors to product ion transitions monitored for fludrocortisone and IS were m/z 381.2 → 343.2 and 386.2 → 348.4, respectively. The assay was validated with linear range of 40–3000 pg/mL. The intra‐ and inter‐day precisions (relative standard deviation) were within 0.49–7.13 and 0.83–5.87%, respectively. The proposed method was successfully applied to pharmacokinetic studies in humans. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
To characterize the preclinical plasma pharmacokinetics of entrectinib, a reproducible and precise assay is necessary. In this study, we developed and validated a simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method for the measurement of entrectinib using carbamazepine as the internal standard in rat plasma. Sample preparation was a simple protein precipitation with acetonitrile, then entrectinib was eluted on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm) using a gradient elution with a mobile phase composed of acetonitrile (A) and 0.1% formic acid in water (B). Detection was achieved using multiple‐reaction monitoring in positive ion electrospray ionization mode. The method showed good linearity over the concentration range of 1–250 ng/mL (r2 > 0.9951). The intra‐ and inter‐day precision was determined with the values of 6.3–12.9 and 2.6–6.9%, respectively, and accuracy values of 0.5–11.6%. Matrix effect, extraction recovery, and stability data all met the acceptance criteria of US Food and Drug Administration guidelines for bioanalytical method validation. The method was successfully applied to a pharmacokinetic study. In this study, we developed the complete validated method for the quantification of entrectinib in rat plasma.  相似文献   

10.
Doping control analysis of performance‐enhancing peptides in urine represents a challenging requirement in modern sports drug testing. Low dosing, effective metabolism and short half‐life lead to target concentrations in the low fmol/mL range in urine. Synthetic adrenocorticotropic hormone (1‐24, Syn‐ACTH‐en) shares all these characteristics and improved analytical performance is required for its sufficient determination by means of liquid chromatography/tandem mass spectrometry (LC/MS/MS). The desired effects for cheating sportsmen are mainly due to enhanced release of corticosteroids as well as androgenic steroids into the circulation after systemic administration of the drug. Immunoaffinity purification with coated magnetic beads and subsequent liquid chromatography with nano‐ultra‐performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (high resolution/high mass accuracy) of Synacthen from urinary specimens is described in the present study. The general proof of principle was obtained by analysis of excretion study urine samples and validation was performed with focus on the limit of detection (3 pg/mL), linearity, precision (<20%), recovery (~30%), robustness, specificity and stability. For all experiments, the ACTH fragment 1‐17 was used as the internal standard. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Salvianolic acid A (SAA), a major effective constituent of Salvia miltiorrhizas, is widely used in traditional Chinese medicine. A sensitive rapid analytical method was established and validated for SAA in rat plasma, which was further applied to assess the pharmacokinetics of SAA in rats receiving a single oral dose of SAA. The method used liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with chloramphenicol as the internal standard. A simple liquid-liquid extraction based on ethyl acetate was employed. The combination of a simple sample cleanup and short chromatographic run time (3 min) increased the throughput of the method substantially. The method was validated over the range 1.4-1000 ng/mL with a correlation coefficient >0.99. The lower limit of quantification was 1.4 ng/mL for SAA in plasma. Intra- and inter-day accuracies for SAA were 95-113 and 98-107%, and the inter-day precision was less than 12%. This method is more sensitive and faster than previous methods. After a single oral dose of 100 mg/kg of SAA, the mean peak plasma concentration (Cmax) of SAA was 318 ng/mL at 0.5 h, the area under the plasma concentration-time curve (AUC0-12 h) was 698 +/- 129 ng.h/mL, and the elimination half-life (T1/2) was 3.29 h.  相似文献   

12.
Steroid hormones play a critical role in maintaining the homeostasis of human metabolism. Urine as a noninvasive sample has been extensively used in clinical diagnosis for hormones homeostasis. In this study, the simultaneous characterization of fourteen hormones in urine was performed based on ultra‐high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPHLC/ESI(+)‐MS/MS) with multiple reaction monitoring in the positive ionization mode. The target hormones were cortisone, cortisol, 11‐deoxycortisol, aldosterone, corticosterone, 11‐deoxycorticosterone, progesterone, 17‐OH‐progesterone, pregnenolone, estrone, estradiol, estriol, testosterone and dehydreopiandrosterone. β‐Glucuronidase/sulfatase deconjugation and liquid–liquid extraction (LLE) were conducted for the determination of urinary hormones (free + conjugated forms). The limits of detection (LODs) ranged from 0.2 ng/mL (11‐deoxycortisol and testosterone) to 1 ng/mL (cortisone). The extraction recovery of the targeted compounds ranged from 87% to 127%, indicating sufficient extraction efficiency for the LLE process. Intraday precision was below 10% and the accuracy ranged from 84% to 122%. The profiling analysis of hormones in urine samples helps to understand the metabolic state of biological systems and can be employed as a diagnostic tool in diseases developed by endocrine‐disrupted systems.  相似文献   

13.
14.
BMS-378806 is a human immunodeficiency virus (HIV) entry inhibitor that is being developed for the oral treatment of HIV infection. Human plasma and urine LC/MS/ MS methods have been developed and validated for the quantitation of BMS-378806. For human plasma method, methyl t-butyl ether was used to extract BMS-378806 from plasma in a 96-well format, and the organic layers were dried down and then reconstituted for the injection, while a dilute-and-shoot approach was used for human urine method in a 96-well format. Chromatographic separation was achieved isocratically on a Phenomenex C18 (2) Luna column (2 x 50 mm2, 5 microm). The mobile phase contained 60:40 v/v of 0.1% formic acid in water and ACN. Detection was by positive ion electrospray MS/MS. The standard curves ranged from 1.25 to 1000 ng/mL for the plasma assay and from 10 to 5000 ng/mL for the urine assay. The curves were fitted to a 1/x2 weighted quadratic regression model for both methods. The validation results demonstrated that both methods had satisfactory precision and accuracy across the calibration ranges. The methods were applied to the analysis of human plasma and urine samples from a single ascending dose clinical study to assess the pharmacokinetics of the drug. The pharmacokinetic analysis results indicated the absorption and disposition of the drug was rapid. The systemic exposure of BMS-378806 was generally dose proportional among the doses from 100 to 1200 mg, but not dose proportional to 1600 mg. There were modest increases in the systemic exposure when the drug was given with food or given as a solution formulation. Renal excretion was not a substantial elimination pathway of the drug. BMS378806 was safe and well tolerated over a dose range of 100-1600 mg administered as a single oral dose.  相似文献   

15.
A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC‐MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope‐labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra‐ and inter‐batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC‐MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
An automatic on‐line solid‐phase extraction with ultra‐high performance liquid chromatography and tandem mass spectrometry method was developed for the simultaneous determination of ten antipsychotics in human plasma. The plasma sample after filtration was injected directly into the system without any pretreatment. A Shim‐pack MAYI‐C8 (G) column was used as a solid‐phase extraction column, and all the analytes were separated on a Shim‐pack XR‐ODS III column with a mobile phase consisting of 0.1% v/v formic acid in water with 5 mM ammonium acetate and acetonitrile. The method features were systematically investigated, including extraction conditions, desorption conditions, the equilibration solution, the valve switching time, and the dilution for column‐head stacking. Under the optimized conditions, the whole analysis procedure took only 10 min. The limits of quantitation were in the range of 0.00321–2.75 μg/L and the recoveries ranged from 75.9 to 122%. Compared with the off‐line ultra‐high performance liquid chromatography and the reported methods, this validated on‐line method showed significant advantages such as minimal pretreatment, shortest analysis time, and highest sensitivity. The results indicated that this automatic on‐line method was rapid, sensitive, and reliable for the determination of antipsychotics in plasma and could be extended to other target analytes in biological samples.  相似文献   

17.
An ultra‐high‐performance liquid chromatography/electrospray ionisation tandem mass spectrometry system is described for the separation and characterisation of uroporphyrinogen, heptacarboxylic acid porphyrinogen, hexacarboxylic acid porphyrinogen, pentacarboxylic acid porphyrinogen and coproporphyrinogen. The separation was carried out on a 100 mm × 2.1 mm Thermo‐Hypersil BDS column (2.4 µm average particle size) by gradient elution with a mixture of acetonitrile, methanol and 1 mol/L aqueous ammonium acetate buffer, pH 5.16, as eluent. The fragmentation pattern of each compound was established by collision‐induced dissociation tandem mass spectrometry. The most characteristic fragmentation was ring opening at one of the four methylene bridges of the protonated porphyrinogen molecule followed by further cleavages of methylene bridges linking the four pyrrole rings at various points to give product ions with methylenepyrrolenine, methylene‐dipyrrolenine and methylene‐tripyrrolenine structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
19.
A simple and reproducible bioanalytical method for the determination of gemcitabine in human plasma treated with tetrahydrouridine (THU) was developed and validated using a hydrophilic interaction ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC‐MS/MS). To prevent deamination of gemcitabine, blood was treated with THU, and the plasma samples obtained after centrifugation were used in this study. Gemcitabine and gemcitabine‐13C, 15N2 used as an internal standard, were extracted from human plasma treated with THU using a 96‐well Hybrid SPE‐Precipitation plate. Extracts were chromatographed on a hydrophilic interaction chromatography column with isocratic elution. Detection was performed using Quattro Premier with positive electrospray ionization multiple reaction monitoring mode. The standard curve ranged from 10 to 10,000 ng/mL without carryover. No significant interferences were detected in blank plasma and no interferences by 2′‐2′‐difluoro‐2′‐deoxyuridine, a metabolite of gemcitabine. Accuracy and precision in the intra‐batch reproducibility study using quality control samples with three THU levels did not exceed ±5.4 and 7.3%, respectively, and the inter‐batch reproducibility results also met the criteria. Stability of gemcitabine was ensured in whole blood and plasma as well as stability of THU in solutions. The UPLC‐MS/MS method developed was successfully validated and can be applied for gemcitabine bioanalysis in clinical studies. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
Ultra‐performance hydrophilic interaction liquid chromatography (UPHILIC) interfaced with the electrospray ionization (ESI) source of a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of everolimus in mouse plasma samples. UPHILIC was performed on a sub‐2 µm bare silica particle packing with the column pressure under traditional high‐performance liquid chromatography (HPLC) to allow fast separation of pharmaceutical compounds within a chromatographic analysis time of 1 min. This UPHILIC technology is comparable with reversed‐phase ultra‐performance liquid chromatography (RPUPLC) in terms of chromatographic efficiency but demands neither expensive ultra‐high‐pressure instrumentation nor new laboratory protocols. With the ESI source, multiple reaction monitoring (MRM) of the ammoniated adduct ions of the analyte was used for tandem mass spectrometric detection. The retention mechanism profiles of the test compounds under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of the test compounds in positive ion mode were investigated. A UPHILIC/MS/MS approach following a protein precipitation procedure was applied for the quantitative determination of everolimus at the low ng/mL region in support of a pharmacodynamic study. The analytical results obtained by the UPHILIC/MS/MS approach were fond to be in good agreement with those obtained by the RPUPLC/MS/MS method in terms of assay sample throughput, sensitivity and accuracy. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号