首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Understanding how metallodrugs interact with their protein targets is of vital importance for uncovering their molecular mode of actions as well as overall pharmacological/toxicological profiles, which in turn facilitates the development of novel metallodrugs. Silver has been used as an antimicrobial agent since antiquity, yet there is limited knowledge about silver-binding proteins. Given the multiple dispersed cysteine residues and histidine–methionine pairs, Escherichia coli malate dehydrogenase (EcMDH) represents an excellent model to investigate silver coordination chemistry as well as its targeting sites in enzymes. We show by systematic biochemical characterizations that silver ions (Ag+) bind EcMDH at multiple sites including three cysteine-containing sites. By X-ray crystallography, we unravel the binding preference of Ag+ to multiple binding sites in EcMDH, i.e., Cys113 > Cys251 > Cys109 > Met227. Silver exhibits preferences to the donor atoms and residues in the order of S > N > O and Cys > Met > His > Lys > Val, respectively, in EcMDH. For the first time, we report the coordination of silver to a lysine in proteins. Besides, we also observed argentophilic interactions (Ag⋯Ag, 2.7 to 3.3 Å) between two silver ions coordinating to one thiolate. Combined with site-directed mutagenesis and an enzymatic activity test, we unveil that the binding of Ag+ to the site IV (His177-Ag-Met227 site) plays a vital role in Ag+-mediated MDH inactivation. This work stands as the first unusual and explicit study of silver binding preference to multiple binding sites in its authentic protein target at the atomic resolution. These findings enrich our knowledge on the biocoordination chemistry of silver(i), which in turn facilitates the prediction of the unknown silver-binding proteins and extends the pharmaceutical potentials of metal-based drugs.

Silver-binding preference in its authentic protein targets with MDH as a paradigm was uncovered.  相似文献   

2.
N-Boc derivatives of Met, Cys, and Trp, the properties of which resemble those of the respective amino acid residues present in proteins, are efficiently oxidized by methyltrioxorhenium and H2O2. A high regioselectivity for the oxidation of these residues when embedded into peptides was also found.  相似文献   

3.
Zusammenfassung Ein neues Verfahren zur Nitrat- und Nitritspurenbestimmung in verschiedenartigen Lebensmittelproben wird beschrieben. Dazu wird die massenspektrometrische Isotopenverdünnungsanalyse unter Verwendung eines 15NO 3 - und 15NO 2 -Indicators sowie die Messung negativer NO 2 -Thermionen im Massenspektrometer eingesetzt. Als definitive Methode liefert dieses Verfahren vergleichsweise richtige Analysenergebnisse, weshalb es sich vor allem auch als Eichverfahren eignet. Es werden Nitratgehalte in verschiedenen Milchpulver- und Schinkenproben im Bereich 3–170 ppm sowie getrocknete Proben von Pflanzenmaterialien im Bereich 0,1–2 Gew.-% analysiert. Dabei kann die Bestimmung letztgenannter Proben auch als Mikroanalyse erfolgen. Soweit es sich bei den Lebensmitteln um homogenisierte Proben handelt, liegen bei Konzentrationen >100 ppm die relativen Standardabweichungen des Verfahrens im Bereich 0,2–1%, bei Gehalten von 10–100 ppm im Bereich 1,5–3%. Die entsprechende Reproduzierbarkeit für parallel zum Nitrat bestimmtes Nitrit liegt bei 2–6% für Gehalte im Bereich 1–50 ppm. Die Nachweisgrenze für Nitrat und Nitrit ist etwa 0,2 ppm.
New calibration method for the nitrate and nitrite trace determination in food samples
Summary A new analytical procedure for the determination of nitrate and nitrite traces in different food samples is described. Isotope dilution mass spectrometry is applied using a 15NO 3 and a 15NO 2 spike for the dilution technique and measuring negative NO 2 thermal ions in the mass spectrometer. This definitive method provides relatively accurate analysis results. Therefore, it is especially suitable as a calibration method. Nitrate contents in different milk powder samples and ham samples in the range of 3–170 ppm as well as dried samples of different plant materials in the range of 0.1–2% (by weight) are analysed. The determination of the plant material can also be carried out as micro analysis. So far as the food samples are homogeneous, the relative standard deviation of this method is in the range of 0.2–1% for nitrate contents of > 100 ppm and in the range of 1.5–3% for those of 10–100 ppm. The corresponding values for nitrite analysed in parallel to nitrate are 2–6% in the range of 1–50 ppm. The nitrate and nitrite detection limit is about 0.2 ppm.


Vortrag anläßlich des Symposiums Anorganische Anionenanalytik, Regensburg, 19.–21. 9. 1984

Der Deutsche Forschungsgemeinschaft und dem Fonds der Chemischen Industrie danken wir für die finanzielle Unterstützung.  相似文献   

4.
Summary Traces of molybdenum in sea water have been preconcentrated by anion-exchange from acidified samples in the presence of sodium azide. Molybdenum adsorbs strongly on a column of Bio-Rad AG 1 (Cl) and can be stripped easily by elution with 2 mol/l NH4Cl — 2 mol/l NH4OH solution. Molybdenum in the effluent is determined by graphite furnace atomic absorption spectrometry. The combined method allows to determine traces of molybdenum in sea water as well as non-saline water on a 100 ml sample basis. The method gives a relative standard deviation of better than 8% at a molybdenum level of 10 g 1–1 of sea water.
Bestimmung von Molybdänspuren in Meereswasser mit Hilfe einer Kombination von Anionenaustausch und elektrothermischer Atomabsorptionsspektrometrie
  相似文献   

5.
Summary A simple and rapid procedure for the determination of sulphur in geological and biological samples by combustion in an oxygen current followed by coulometric titration of the sulphur dioxide produced is described. Samples analysed include rocks, soils, sediments, ores, minerals and plants. 8-Hydroxyquinoline is used to remove interfering halogens from the combustion products. 100 mg of sample are mixed with 500 mg of V2O5 (oxidant) and 500 mg of Fe (flux) and ignited for 4–15 min in a resistance-type furnace at 1400° C. The method is applicable to sulphur contents in samples of 10 ppm to X0 wt.-% S with standard deviations ranging from 0.001–0.2% S. For testing accuracy 21 standard reference samples were analysed. Results obtained compare favourably with recent publications.
Bestimmung des Gesamt-Schwefels in geologischen und biologischen Substanzen durch coulometrische Titration nach vorhergehender Verbrennung der Probe
Zusammenfassung Es wird eine einfache und schnelle Methode der Schwefelbestimmung in geologischen und biologischen Proben durch Verbrennung im Sauerstoffstrom und anschließende coulometrische Titration des freigesetzten SO2 beschrieben. Es wurden Gesteine, Böden, Sedimente, Erze, Minerale und Pflanzen analysiert. 100 mg der Probe werden mit 500 mg V2O5 (Oxidationsmittel) und 500 mg Fe (Fluß-mittel) in 4–15 min in einem Widerstandsofen bei 1400° C verbrannt. Zur Entfernung von Halogenwasserstoffen aus dem Reaktionsgas wird eine 8-Hydroxychinolin-Falle verwendet. Die Methode ist auf Proben mit Schwefelgehalten von 10 ppm bis X0 Gew.-% anwendbar. Die Standardabweichung liegt im Bereich von 0.001–0.2% S. Es wurden 21 Standardproben analysiert, um die Genauigkeit des Verfahrens zu überprüfen. Die Ergebnisse zeigen eine befriedigende Übereinstimmung mit neueren Literaturdaten.
  相似文献   

6.
Summary The determination of gold at 10–3–10–4% levels in black copper and speiss is based upon selective dissolution of the samples with sulphuric acid and separation of the matrix elements by filtration. Gold is determined in the solid residue by flame atomic absorption spectrometry. Relative standard deviation was 7%–10% for about 20 g Au/t.
AAS-Bestimmung von Gold in Rohkupfer und Speiseprodukten
  相似文献   

7.
Zusammenfassung Es wird ein Verfahren zur Bestimmung von Hafnium in Zirkoniumoxid mittels der Neutronenaktivierungsanalyse beschrieben, das keine besonderen Einrichtungen und Schutzmaßnahmen für den Umgang mit den aktivierten Proben erfordert. Es eignet sich besonders zur Bestimmung von 10–100 ppm HfO2 in ZrO2. Dabei beträgt die relative Standardabweichung 5–10%.
Summary A procedure is described for the determination of hafnium in zirconium oxide by neutron activation analysis. The special feature of the method is the use of low activities only. Therefore no extensive precautions are required. The method is specially suitable for the determination of 10–100 ppm of HfO2 in ZrO2. The relative standard deviation is 5–10%.


Wir danken Herrn Prof. W. Fischer für wertvolle Diskussionen, dem Laboratorium für Technische Physik der Technischen Hochschule München für die Durchführung der Bestrahlungen, dem Bundesministerium für Wissenschaftliche Forschung und dem Fonds der Chemischen Industrie für finanzielle Unterstützung.  相似文献   

8.
Summary A differential pulse-polarographic method has been studied for the determination of vanadium employing the catalytic maximum wave. A well-defined differential pulse polarographic peak is observed in the potential range from –0.2 to –0.7 V vs. SCE for vanadium(V) in 10 mmol 1–1 NaCl containing 10 mmol 1–1 acetic acid, 40 mmol 1–1 pyrocatechol, and 2.5 mmol 1–1 KBrO3. The peak current is very large and proportional to the concentration of vanadium(V) between 1×10–7 and 1×10–6 mol 1–1. The relative standard deviation at 0.5 mol l–1 vanadium(V) was 2.06% (n=7). This method has been successfully applied to the determination of vanadium in standard materials such as pond sediment.
Spurenbestimmung von Vanadium mit Hilfe der katalytischen Maximumsstufe in der Differential-Puls-Polarographie
Zusammenfassung Ein gut definierter differentialpuls-polarographischer Peak wurde für Vanadium(V) in 10 mmol/l NaCl-Lösung, die 10 mmol/l Essigsäure, 40 mmol/l Brenzcatechin und 2,5 mmol/l KBrO3 enthielt, beobachtet (Potentialbereich –0,2 bis –0,7 V gegen SCE). Der Peakstrom ist sehr groß und die Vanadiumkonzentration im Bereich von 1×10–7 bis 1×10–6 mol/l proportional. Die relative Standardabweichung betrug 2,06% (n=7) bei 0,5 mol/l Vanadium(V). Das Verfahren wurde mit gutem Erfolg zur Vanadiumbestimmung in Standardproben (z.B. Teichsediment) eingesetzt.
  相似文献   

9.
Summary The HPLC behaviours of Cr(VI), Mo(VI) and V(V) peroxo complexes in a H2O2-8-hydroxyquinolinebipyridine system were studied by using pre-column in combination with on-column derivatisation. The chromatograms of Cr(VI), Mo(VI) and V(V) show them to be CrO2– 4, oxine-Mo peroxo and oxine-V-bipyridine peroxo complexes, respectively, and were used for the separation, identification and determination of Cr(VI), Mo(VI) and V(V) using acetonitrile-water as mobile phase. The calibration curves obtained for 20 l injections were linear for 1.4–7.0 mg/l Cr, 1.3–6.5 mg/l Mo and 0.7–3.4 mg/l V. The relative standard deviations were between 6 and 10%.
HPLC-Analyse von Cr, V und Mo unter Verwendung von Vorsäulen- in Kombination mit Säulenderivatisierung durch Oxin, Bipyridin und H2O2
  相似文献   

10.
Summary The proposed method for the determination of Cr in gallium arsenide is based on the catalytic activity of chromium(VI)-DTPA complex in the presence of nitrate ions. After dissolution of gallium arsenide with hydrochloric and nitric acids and volatilization of arsenic, chromium is oxidised to chromate with potassium chlorate in nitric acid. After nitric acid removal, the 0.012 M DTPA — 2.5 M LiNO3 supporting electrolyte buffered with 0.2 M CH3COONa — 0.05 M CH3COOH is directly added to the residue. Differential pulse polarography of this solution provides a detection limit of about 100 ng g–1, with a relative standard deviation of ±2–5% and a reproducible calibration curve up to at least 1 g of Cr(VI) ml–1.
Differential-pulspolarographische Bestimmung von Chrom in Galliumarsenid
Zusammenfassung Das vorgeschlagene Verfahren beruht auf der katalytischen Aktivität des Chrom(VI)-DTPA-Komplexes in Gegenwart von Nitrationen. Nach Auflösung des Galliumarsenids mit Salz- und Salpetersäure, wird Arsen verflüchtigt und Chrom mit KClO3/HNO3 zu Chromat oxidiert. Die Salpetersäure wird entfernt und der Rückstand direkt mit dem Trägerelektrolyt versetzt (0,012 M DTPA — 2,5 M LiNO3, gepuffert mit 0,2 M CH3COONa — 0,05 M CH3COOH). Durch Differentialpulspolarographie dieser Lösung erhält man eine Nachweisgrenze von etwa 100 ng g –1. Die relative Standardabweichung beträgt ± 2–5%, die Eichkurve ist reproduzierbar bis 1 g Cr(VI) ml–1.
  相似文献   

11.
Summary N-Bromosuccinimide has been successfully applied in the determination of 1–50 mg of W(CN)8 4–in approximately 6 M hydrochloric acid using Naphthol Blue Black indicator. The average error is ±0.42% and the average standard deviation is ±0.06 mg. The method is not applicable to the determination of Mo(CN) 8 4– ions. Tetrakis-(N-hydro-2-carbocyclic acid-pyridinium)octacyanotungstate(IV) and -molybdate(IV) were used as primary standards for the preparation of standard Mo(IV) and W(IV) solutions. The composition of the latter compounds was verified by analysis and single crystal X-ray data were obtained.
Titrimetrische Bestimmung von Octacyanowolframat(IV)-ionen mit N-Bromsuccinimid
Zusammenfassung N-Bromsuccinimid wurde mit Erfolg zur Bestimmung von 1–50 mg W(CN)8 4–-Ionen in ungefähr 6 M Salzsäure mit Naphthol-Blau-Schwarz als Indicator verwendet. Der mittlere Fehler beträgt ±0,42 %, die mittlere Abweichung ±0,06 mg. Die Methode ist nicht brauchbar für die Bestimmung von Mo(CN)8 4–-Ionen. Tetrakis(N-hydro-2-carbonylsäure-pyridinium) octacyanowolframat(IV) und -molybdat(IV) wurden als Primärstandards für die Herstellung von Standard-Mo(IV)- und -W(IV)-Lösungen benutzt. Die Zusammensetzung dieser Verbindungen wurde durch Analyse kontrolliert und die Einkristall-Röntgen-Daten wurden festgestellt.
  相似文献   

12.
Ion-exchange LC and spectroscopic supporting techniques have been successfully used to study the kinetics and mechanism of oxidation reactions of selenomethionine (SeMet). Oxidation of selenomethionine with both cyanogen bromide (CNBr) and hydrogen peroxide (H2O2) proceeds through a stable intermediate which undergoes cyclization and C-Se bond cleavage to form 2-amino-4-butyrolactone. This stable intermediate was identified by IR spectroscopy as methionine dihydroxy selenide. The CH3-Se moiety of SeMet formed methyl selenic acid upon reaction with H2O2 and methyl selenocyanate (CH3SeCN), characterized by GC-MS, for the reaction with CNBr. Both reactions were of apparent first order with respect to the concentration of SeMet. A rate constant (k1)of 4.0×10–3 s–1 for the reaction of SeMet with HO and 4.0×10–3 s–1 for the reaction with CNBr were determined at a temperature of 22°C. Oxidation of methionine (Met) gives disparate kinetics and oxidation products from SeMet. Thus the differential rate method can be utilized to quantitatively separate SeMet in biological samples in the presence of much higher concentrations of Met.  相似文献   

13.
Zusammenfassung Die in der Literatur bekannten Verfahren zur Anreicherung von Spurenelementen aus Reinstquecksilber — Destillation des Metalls, Reduktion des Nitrats mit Ameisensäure, fraktionierende Matrixextraktion aus jodidhaltiger Lösung — wurden auf ihre Verwendbarkeit zur Palladiumanreicherung in Quecksilberpräparaten untersucht. Alle diese Methoden erwiesen sich als ungeeignet.Auch das von uns bereits publizierte Verfahren zur Anreicherung von Palladiumspuren durch Mitfällen an AgCN ist in der ursprünglichen Fassung nicht auf Quecksilberpräparate anwendbar. Eine praktisch vollständige Mitfällung des Palladiums wird erst erreicht, wenn das in Salpetersäure gelöste gesamte Quecksilber vor der AgCN-Fällung in Hg(CN)2 überführt wird. Der AgCN-Niederschlag wurde spektrochemisch analysiert. Für Quecksilbermetall mit 10–6% Pd beträgt die relative Standardabweichung etwa 0,18. Die Nachweisgrenze liegt bei 5 · 10–7% Pd.
On the enrichment of traces of palladium in high-purity mercury
The methods usually applied for the enrichment of trace elements in high-purity mercury—destination of the metal, reduction of the nitrate with formic acid, fractional extraction out of the iodide containing solution—were examined as to their efficiency for the enrichment of palladium in mercury. All these methods proved to be not qualified. In the presence of mercury this is also valid for a method, in which palladium is co-precipitated on AgCN. As we have published earlier, AgCN is a suitable trace collector for Pd in many materials.However, a practical complete co-precipitation of the palladium is possible, when all the mercury, solved in nitric acid, is converted into Hg(CN)2 before the AgCN is precipitated. The AgCN precipitate was analysed spectrochemically. For the analysis of metallic mercury containing 10–6% Pd the relative standard deviation is about 0.18. The limit of detection was found to be at 5×10–7% Pd.
  相似文献   

14.
Zusammenfassung Ein Verfahren zur Analyse von Ätzlösungen wird beschrieben, die gelöste Sulfat- und Fluorionen enthalten. Die Ionen werden in einer Austauschersäule DOWEX 1×8, 50–100 mesh, bei pH 5 bis 6,5 getrennt, das Fluor mit 0,1 M NH4Cl-Lösung eluiert und mit ÄDTA-Lösung gegen CaCl2-Lösung titriert. Die Sulfatbestimmung erfolgt im Ausgangsgemisch durch Titration mit 0,1 N NaOH-Lösung mit Methylorange als Indicator. Der relative Fehler der Fluorbestimmung liegt bei ±1–1,5%.
Separation and determination of SO4 2– and F ions in etching solutions
The ions are separated in an exchange column of DOWEX 1×8 (50–100 mesh) at pH 5–6.5. F is eluated with a 0.1 M solution of NH4Cl and the excess of CaCl2 solution is titrated back with EDTA. The error is about 1–1.5%.The SO4 2– content is determined by titration with a 0.1 N solution of NaOH; indicator is methylorange.
  相似文献   

15.
Summary 1-amino-4-hydroxyanthraquinone (AMHA) is proposed as a spectrophotometric reagent for the determination of yttrium. The solution equilibria ofAMHA complexes with Y(III) have been studied spectrophotometrically in 50% (v/v) ethanol at 25°C and an ionic strength ofI=0.1 mol·dm–3 (NaClO4). The complexation reactions were investigated and characterized using graphical logarithmic analysis of the absorbance graphs. The composition, molar absorptivities, and stability constants of the chelates ofAMHA with Y(III) have been determined spectrophotometrically. A simple, rapid, selective, and sensitive method for the spectrophotometric determination of microamounts of Y(III) is developed based on the formation of the violet YLH+ complex with max=580nm atpH 6.2(=0.98×104l·mol–1·cm–1). Interferences and their elimination have been studied. Many foreign ions are tolerated in considerable amounts; 45–60 fold amounts of rare earths do not interfere with the determination of yttrium. In the determination of yttrium in synthetic polymetallic samples the relative error and relative standard deviation of the method were found to be better than 1 and 0.5%, respectively.
Spektrophotometrische Bestimmung von Mikromengen Yttrium mit 1-Amino-4-hydroxyanthrachinon
Zusammenfassung 1-Amino-4-hydroxyanthrachinon (AMHA) wird als spektrophotometrisches Reagens zur Bestimmung von Yttrium vorgeschlagen. Die Gleichgewichte von Komplexen ausAMHA und Y(III) in Lösung wurden in 50% (v/v) Ethanol bei 25°C und einer lonenstärke vonI=0.1M (NaClO4) untersucht. Die Komplexierungsreaktionen wurden durch graphische logarithmische Analyse der Extinktionskurven charakterisiert. Die Zusammensetzungen, die molaren Extinktionen und die Stabilitätskonstanten der Chelate vonAMHA mit Y(III) wurden spektrophotometrisch bestimmt. Eine einfache, schnelle, selektive und empfindliche Methode zur spektrophotometrischen Bestimmung von Mikromengen Y(III) wurde entwickelt. Sie basiert auf der Bildung des violetten YLH+-Komplexes mit max=580 nm beipH 6.2 (=0.98×104l·mol–1·cm–1). Störungen und ihre Beseitigung werden ebenfalls diskutiert. Viele Fremdionen werden in beträchtlichen Mengen toleriert; 45–60 facher Überschuß an Seltenen Erden stört die Bestimmung von Yttrium nicht. Der relative Fehler und die relative Standardabweichung der Methode bei der Bestimmung von Yttrium in synthetischen polymetallischen Proben waren besser als 1 bzw 0.5%.
  相似文献   

16.
Zusammenfassung Der rote Nickel-PAN-Komplex wird bei pH 10 mit Chloroform extrahiert. Störendes Eisen und Kupfer werden durch Tiron maskiert. Bei Molybdän- und Wolframproben mit 5 bis 100 ppm Ni beträgt die Standardabweichung ±1,6 ppm Ni.
Summary The red nickel-PAN-complex is extracted with chloroform at pH 10. Interfering iron and copper are masked with Tiron. The standard deviations in samples of molybdenum and tungsten containing 5–100 ppm nickel was ± 1.6 ppm Ni.

Resume On extrait le complexe rouge nickel-PAN à pH 10 par le chloroforme. On masque le fer et le cuivre qui gênent, par le Tiron. Pour les échantillons de molybdène et de tungstène à 5–100 ppm de nickel, la déviation standard s'élève à ±1,6 ppm de nickel.
  相似文献   

17.
Summary A method is described for the simultaneous speciation of Fe(CN) 6 4– and Fe(CN) 6 3– in a flow injection (FIA) system comprising electrochemical (EC) and flame atomic absorption spectrometry (AAS) detectors in series. One of these species is detected amperometrically at a Pt-electrode by applying the required potential and measuring the resulting reduction or oxidation current of the appropriate iron cyanide complex. Total iron in both species is determined by an AAS detector. The EC detector is inherently more sensitive, with a detection limit of 0.5 g Fe l–1 and a relative standard deviation of 1.0% for a 0.040 g Fe ml–1 sample. The limit of detection for the AAS detector is 0.5 g Fe ml–1, and the relative standard deviation for a 5.70 g Fe ml–1 sample is 0.40%. The method enables up to 60 analyses (120 speciations) per hour and obviates the problem of easy oxidation of Fe(CN) 6 4– .
Simultane Speziation von Eisen(II)- und Eisen(III)-Cyanokomplexen durch Flie\injektionsanalyse mit Hilfe von hintereinander geschalteten elektrochemischen und AAS-Detektoren
  相似文献   

18.
Summary A nitrate-selective electrode based on precipitated nitron nitrate in an epoxy resin matrix has been prepared. The lower detection limit is 10–5 M, the optimum pH range is 2.0–8.5, and the response time is 1 min. The electrode is selective in presence of CH3COO, SO4 2–, C2O4 2–, PO4 3–, NO2 , Cl and Br, but I interferes. Results for nitrate in soil samples were in agreement with values obtained spectrophotometrically.
Eine neue nitrat-spezifische Elektrode auf der Basis gefällten Nitronnitrats
Zusammenfassung Eine nitrat-spezifische Elektrode auf der Basis gefällten Nitronnitrats in einer Epoxyharz-Matrix wurde hergestellt. Die untere Nachweisgrenze ist 10–5 M, das pH-Optimum liegt zwischen 2,0 und 8,5, die Reaktionszeit beträgt 1 Minute. Die Elektrode ist selektiv in Gegenwart von Acetat, Sulfat, Oxalat, Phosphat, Nitrit, Chlorid und Bromid; aber Jodid stört. Ergebnisse der Nitratbestimmung in Bodenproben stimmen mit spektrophotometrischen Resultaten überein.


Presented at the 8th International Microchemical Symposium, Graz, August 25–30, 1980.  相似文献   

19.
Summary 4 combination preparations of Trimethoprim (TMP) and Sulphamethoxazole (SMZ) were administered to 8 healthy male subjects and plasma samples were analysed after extraction of TMP and SMZ by high-performance liquid chromatography with a variable UV-detector at 230 and 280 nm. The Chromatographic system consisted of a Waters reversed-phase C18 column and a mobile phase containing phosphate buffer, pH 5.0, and ethanol (80 + 20). A dose of 80 mg TMP × 400 mg SMZ results in a plasma concentration of 0.05–1.0 g/ml TMP and 1–20 g/ml SMZ during 26 h after drug administration. The relative standard deviation for TMP was found to be ±5–7% and for SMZ ±2–3%.
HPLC-Analyse von Trimethoprim und Sulfamethoxazol in Plasma
Zusammenfassung 4 Kombinationspräparate von Trimethoprim (TMP) und Sulphamethoxazol (SMZ) wurden 8 gesunden männlichen Probanden verabreicht. Die Bestimmung von TMP und SMZ in Plasmaproben erfolgte nach Extraktion durch Hochdruckflüssigkeits-Chromatographie mit einem UV-Detektor bei 230 und 280 nm. Es wurden eine Waters-Reversed-Phase-C18-Säule und ein Phosphatpuffer(pH 5,0)-Ethanolgemisch (80 + 20) als Fließmittel verwendet. Nach Verabreichung einer Dosis von 80 mg TMP + 400 mg SMZ betrugen während 26 h die Plasmakonzentrationen von TMP und SMZ 0,05-1 g bzw. 1–20 g/ ml. Die relative Standardabweichung für TMP beträgt ±5–7% und für SMZ ±2–3%.
  相似文献   

20.
A micro-combustion calorimeter was developed. The small energy equivalent (ca. 68 JK–1) of this calorimeter makes it possible to measure combustion energies of very small samples. The energy equivalent was determined by burning 2 mg of benzoic acid. The standard deviation of the mean energy equivalent was reduced to 0.014% in 5 experiments. The standard massic energy of combustion of salicylic acid and the standard deviation of the mean were determined to be –21871±5 J g–1, which agrees well with the literature values. The standard molar enthalpy of formation of salicylic acid was derived as –591.2±1.7 kJ mol–1.This revised version was published online in November 2005 with corrections to the Cover Date.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号