共查询到20条相似文献,搜索用时 0 毫秒
1.
The feasibility of using capillary columns equipped with silica frits and packed with a polymer-based anion exchanger (Dionex AS9-HC) for CEC separations of inorganic anions has been investigated. Experiments using a conventional 25 cm packed bed, and mobile phase flow that is a combination of hydrodynamic and electroosmotic flow were used to demonstrate that by varying the applied voltage (electrophoresis component) or the concentration of the competing ion in the mobile phase (ion-exchange component), considerable changes in the separation selectivity could be obtained. Using an artificial neural network, this separation system was modelled and the results obtained used to determine the optimum conditions (9 mM perchlorate and −10 kV) for the separation of eight inorganic anions. When a short (8 cm) packed bed was used, with detection immediately following the packed section, the separation of eight test analytes in under 2.2 min was possible using pressure-driven flow and a simple step voltage gradient. A more rapid separation of these analytes was obtained by only applying high voltage (−30 kV), where many of the same analytes were separated in less than 20 s and with a different separation selectivity to that obtained in conventional ion-exchange or capillary electrophoresis separations. 相似文献
2.
A novel and simple method for the preparation of silica nanoparticles having surface-functionalized diamino moiety (dASNPs) was reported in our paper and characterized using scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectrometry, and thermogravimetry techniques. To test this method practically, in this contribution we describe the enhanced separation of four plant auxins - indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), 2,4-dichlorophenoxyacetic acid (dCPAA), and 2-(1-naphthyl) acetic acid (NAA) - by capillary electrochromatography using diamino moiety functionalized silica nanoparticles as pseudostationary phase (PSP) in the running buffer. The effect of pH, buffer concentration, and diamino moiety functionalized silica nanoparticles concentration on the selectivity of separation was investigated. A combination of the nanoparticles and running buffer reversed the electroosmotic direction making possible the rapid and efficient separation of the auxins from the auxins migrated in the same direction with the EOF under optimum experimental conditions. A good resolution of four auxins was obtained within 5.5 min under optimum experimental conditions. The precision (RSD, n = 5) was in the range of 0.72-0.91% and 1.89-2.23% for migration time and peak area response, respectively. The detection limits were 0.48, 0.44, 0.46, and 0.42 μM for NAA, IBA, IAA, and dCPAA, respectively. Furthermore, the method was successfully tested for the determination of IAA in the grapes. 相似文献
3.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes. 相似文献
4.
Li-Xiao He Chun-Rong Tian Jun-Hui Zhang Wen Xu Bo Peng Sheng-Ming Xie Min Zi Li-Ming Yuan 《Electrophoresis》2020,41(1-2):104-111
Since some metal-organic cages (MOCs) have been synthesized in past several years, the applications of MOCs such as drug delivery, molecular recognition, separation, catalysis, and gas storage, etc. have been witnessed with a significant increase. However, to the best of our knowledge, so far no one has used MOCs as chiral stationary phase to separate chiral compounds in CEC. In this study, three MOCs were developed as the stationary phase for CEC separation of enantiomers. The MOCs coated capillary column showed good chiral recognition ability for some chiral compounds, including amine, alcohols, ketone, etc. The influence of buffer concentration, applied voltage, pH of buffer solution on the chiral separations was also investigated. The RSDs of run-to-run, day-to-day, and column-to-column for retention time were 2.1-4.67%, 1.2-4.36%, and 3.62-6.43%, respectively. This work reveals that the chiral MOCs material is feasible for the enantioseparation in CEC. 相似文献
5.
Poly(N-isopropylacrylamide) (PNIPAM) is an interesting class of temperature sensitive, water soluble polymer that has a lower critical solution temperature (LCST) of 32 °C. Above the LCST, PNIPAM gets phase-separated and precipitates out from water. The fascinating temperature-sensitive property of PNIPAM has led to a growing interest in diverse fields of applications. Recently, capillary electrochromatography (CEC) has gained attention due to the wide range of applications based on the use of open tubular capillaries. In this paper, the use of phase-separated PNIPAM as a pseudostationary phase for CEC is demonstrated for the detection of single nucleotide polymorphisms (SNPs). Owing to the dynamic coating, the phase-separated PNIPAM particles did not require any immobilization technique and could exist as a mobile stationary phase in the open tubular capillary. The heteroduplex analyses of mutation samples could be successfully performed based on the phase-separated PNIPAM particles in the constructed CEC system. The CEC system, based on PNIPAM particles capable of having a narrow size distribution, shows great potential as an alternative to conventional DNA mutation systems. 相似文献
6.
The analytical potential of the use of surfactant-coated single-walled carbon nanotubes (SC-SWNTs) as pseudostationary phase in CE is described. The pseudostationary phase shows an efficient alternative in enhancing electrochromatographic resolution of compounds which are capable of interacting with a nanotube surface, such as aromatic compounds. In general, the resolution is enhanced by increasing nanotube concentration in the buffer but the maximum amount of SWNTs that can be added to background electrolyte was found limited by compatibility with the UV/visible detection. As an alternative, a low-extension partial filling was used, consisting of the introduction into the capillary of concentrated SC-SWNT, just before the sample, with a plug length similar to the sample one. This has been showed as a reliable procedure in increasing resolution and sensitivity by sweeping phenomena. Finally, the potential of SC-SWNTs to perform chiral separations is discussed. 相似文献
7.
The suitability of noncovalently bilayer-coated capillaries for the analysis of proteins by capillary electrophoresis (CE) at medium pH was investigated. Fused-silica capillaries were coated simply by successively flushing with a polybrene (PB) and a poly(vinyl sulfonate) (PVS) solution. A protein test mixture was used to evaluate the performance of the coated capillaries. Comparisons with bare fused-silica capillaries were made. Several background electrolytes (BGEs) were tested in combination with the PB-PVS coating, showing that optimum performance was obtained for the proteins using high BGE concentrations. With a 300 mM Tris phosphate buffer (pH 7.0), good plate numbers (150,000-300,000), symmetrical peaks, and favorable migration-time repeatabilities (RSDs below 0.8%) were obtained for the proteins. Using bare fused-silica capillaries, the protein peaks were significantly broadened and the migration-time RSDs often exceeded 5%. It is concluded that the PB-PVS coating effectively minimizes adverse protein adsorption and provides a very stable electroosmotic flow (EOF). We also investigated the potential of a commercially available bilayer coating (CEofix) for protein analysis. It is demonstrated that with this coating, good plate numbers and peak symmetries for proteins can be achieved when the CEofix BGE ("accelerator") is replaced by a common BGE such as sodium or Tris phosphate. Apparently, the negatively charged polymer present in the "accelerator" interacts with the proteins causing band broadening. The utility of the bilayer coatings is further illustrated by the separation of proteins such as interferon-alpha 2b, myoglobin and carbonic anhydrase, by the analysis of a degraded insulin sample in time, and by the profiling of the glycoprotein ovalbumin. In addition, it is demonstrated that even in the presence of concentrations of human serum albumin in the sample of up to 60 mg/mL, the PB-PVS coating still provides reproducible protein separations of good performance. 相似文献
8.
Amphiphilic silica nanoparticles surface-functionalized by 3-aminopropyltriethoxysilane (APTES) and octyltriethoxylsilane (OTES) were successfully prepared and characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectrometry (FT-IR) and thermogravimetry (TG) techniques. The potential use of these bifunctionalized nanoparticles as pseudostationary phases (PSPs) in capillary electrophoresis (CE) for the separation of charged and neutral compounds was evaluated in terms of their suitability. As expected, fast separation of representative aromatic acids was fulfilled with high separation efficiency, because they migrate in the same direction with the electroosmotic flow (EOF) under optimum experimental conditions. Using a buffer solution of 30mmol/L phosphate (pH 3.0) in the presence of 0.5mg/mL of the synthesized bifunctionalized nanoparticles, the investigated basic compounds were baseline-resolved with symmetrical peaks. Due to the existence of amino groups on the surface of nanoparticles, "silanol effect" that occurs between positively charged basic analytes and the silanols on the inner surface of capillary was greatly suppressed. Furthermore, the separation systems also exhibited reversed-phase (RP) behavior when neutral analytes were tested. 相似文献
9.
The chiral separation ability of a capillary packed with teicoplanin aglycone as a chiral stationary phase was investigated. This stationary phase was used successfully for chiral resolution of both diastereomeric dipeptides and tripeptides possessing one or two chiral centers. The composition of the mobile phase was shown to be crucial for separation. The use of reversed-phase mode was clearly superior to the polar-organic mode. The nature of the organic modifier was found to have a marked influence on separation. After optimizing conditions, all diasteromeric dipeptides and tripeptides investigated were baseline-resolved, however, it was not possible to find a uniform mobile phase showing optimal results for all peptides investigated. 相似文献
10.
The solutions of linear polymers traditionally used for DNA separation have been employed for the capillary electrophoresis (CE) of diastereomers of chemically modified DNA. The selectivity of diastereomeric separation of the phosphorothioate (PS) and 2'-O-methylated (2-OMe) PS oligonucleotides depends on the nature of the polymer additive in the CE background electrolyte. The selectivity of separation for different polymers increases in the line: linear polyacrylamide < polyethylene glycol < polyvinyl pyrrolidone. The separation of oligomer diastereomers was shown to be primarily based on the hydrophobic interaction with the polymer network that acts as a pseudostationary phase. While lowering the temperature resulted in improved separation, the addition of organic modifiers such as formamide, methanol or acetonitrile counteracts the solute adsorption on the polymer network, and decreases the selectivity of DNA diastereoseparation. The effect of molecular mass and concentration of the polymer on the separation selectivity was investigated. 相似文献
11.
Enantiomeric separations in capillary electrochromatography (CEC) carried out using a continuous-bed chiral stationary phase (CSP) based on the macrocyclic antibiotic, vancomycin, is presented. The continuous beds were prepared from methacryloxypropyl modified fused silica capillaries (100 microm ID) by in situ copolymerization of N-(hydroxymethyl)acrylamide and piperazine diacrylamide with vinyl sulfonic acid comonomer used to introduce ionic functionality and thus a strong electroosmotic flow (EOF). The CSP was subsequently prepared by immobilizing the vancomycin stationary phase by reductive amination. Preliminary results have indicated that an extremely strong EOF is obtained in both the nonaqueous polar organic (15.2 x 10(-5) cm2 V(-1) s(-1) and the aqueous reversed-phase modes of operation (8.5 x 10(-5) cm2 V(-1) s(-1)). Enantioselectivity was obtained for four racemic compounds, the best of which was in the case of thalidomide which was separated in 10 minutes with high resolution (Rs = 2.5) and efficiency (120,000 plates meter(-1)) values. 相似文献
12.
This work presents the application of membrane technology for the fabrication of stationary phase for CEC columns using the technique based on phase inversion of polymer solution. A blend of polyimide P84 and sulphonated poly(ether ether ketone was processed via immersion precipitation dry‐wet spinning into small‐bore porous fiber. The morphology, zeta potential, and performance of the porous structure in the CEC separation were investigated. Noncharged molecules (as markers of the electroosmotic flow) and small organic compounds were injected into the column, driven under the application of voltage, and detected on the electropherogram. The proof of concept of applying porous membrane structure as stationary phase for CEC was shown and possible optimization to improve efficiency and selectivity was suggested. 相似文献
13.
Dextran sulfate, a polyanionic polysaccharide, was evaluated as a chiral additive in capillary electrophoresis. Structurally related compounds having a variety of functional groups were utilized to probe the selectivity of the chiral selector. The effects of pH, chiral selector concentration, and chiral selector composition on resolution were also studied. At low pH, the reversed polarity mode was employed to achieve separation of the probe compounds. The electrophoretic results provided insight into the chiral recognition of dextran sulfate in capillary electrophoresis. Several factors, including hydrophobic, steric, and electrostatic interactions, appeared to play a role in the observed enantioseparations. 相似文献
14.
This work describes the separation of basic aromatic compounds by capillary electrochromatography employing acidic carrier electrolytes and bare silica as well as strong cation-exchange stationary phases. A mixed-mode separation mechanism was involved, comprising chromatographic interactions (adsorption, ion-exchange) as well as electrophoretic migration. The influence of ion-exchange on the retention/migration of the solutes could be manipulated according to procedures commonly employed in ion chromatography. These include variations of the eluting strength and/or the concentration of the competing ion present in the background electrolyte. Using this approach, separation times could be shortened and changes in selectivity could be achieved for a number of analytes. 相似文献
15.
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption. 相似文献
16.
The application of indirect spectrophotometric detection was investigated for a capillary electrochromatographic system in which an anion-exchange stationary phase (in the form of aminated latex particles) was coated onto the wall of a fused-silica capillary. The study has focused on the choice of the type and concentration of the absorbing coion (probe) added to the background electrolyte and the role of this species in manipulating the ion-exchange contributions to the separation with a view to controlling the selectivity of the separation. Common inorganic anions were used as analytes and nitrate, p-toluenesulfonate, nicotinate, and chromate were investigated as probes. It was found that most of these probes produced only a limited range of separation selectivities when their concentration was varied over the practically accessible range. p-Toluenesulfonate provided the greatest variation in selectivity, but peak distortion due to electromigration dispersion was evident for the faster ions. When variation of the separation selectivity - from predominantly electrophoretic in nature to predominantly ion-exchange in nature - was desired, this was best achieved by varying the type of probe rather than its concentration. For example, the nitrate probe provided predominantly electrophoretic separations with good peak shapes and high efficiencies. A comprehensive list of probes, ranked in order of ion-exchange selectivity coefficients determined by ion chromatography, was compiled and this proved to be a useful tool to assist in the selection of a probe for a desired separation selectivity. The limits of detection for the analytes and probes studied ranged from 20-55 micromol for the chromate system to 230-600 micromol for the nicotinate system, with nitrate and p-toluenesulfonate giving intermediate values. 相似文献
17.
Thomas Eimer Klaus K. Unger Takao Tsuda 《Fresenius' Journal of Analytical Chemistry》1995,352(7-8):649-653
Pressurized flow electrochromatography (PEC) is a hybrid of capillary LC and capillary electroendosmotic chromatography (CEC). Both a pressure gradient and an electric field are applied across a packed capillary. The feasability of a simple, easy to handle PEC instrumentation is demonstrated. Home made capillary columns with four different silica-based reversed phase packings have been operated under PEC conditions separating non ionic and ionic low molecular weight analytes. The capillary columns have been characterized with respect to their separation efficiency and selectivity and the results have been compared to those obtained with the purely pressure driven system. An electrochromatographic capacity factor is discussed.Dedicated to Professor Dr. Dr. h.c. mult. J.F.K. Huber on the occasion of his 70th birthday 相似文献
18.
Dorothee Wistuba 《Journal of chromatography. A》2010,1217(7):941-952
Chiral-modified silica-based monoliths have become well-established stationary phases for both high performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). The silica-based monoliths were fabricated either in situ in the capillaries for nano-HPLC and CEC or in a mould for “conventional” HPLC. The present review summarizes the chiral modification of silica monoliths and the recent development in the field of enantioselective separations by nano-HPLC and CEC. 相似文献
19.
Nanoparticles exhibiting favorable surface-to-volume ratios create efficient stationary phases for electrochromatography. New nanomaterials derived from chitosan (CS) were immobilized onto modified capillaries for use as the chiral stationary phase (CSP) in open-tubular electrochromatography. This immobilization was achieved through the copolymerization of glycidyl methacrylate-modified nano-CS with methacrylamide (MAA) and bis-acrylamide crosslinkers (forming the MAA-CS capillary) rather than the attachment of nano-CS to the copolymer of glycidyl methacrylate, MAA, and bis-acrylamide (forming the MAA+CS capillary). The completed MAA-CS capillary and its precursors were examined by SEM and ATR-IR measurements. Before separating chiral samples, the MAA-CS capillary was characterized by electroosmotic flow measurements at varying pH values, concentrations, and volume percentages of organic modifiers in the running buffers. Tryptophan enantiomers were well separated by the MAA-CS capillary, whereas no enantioselectivity was observed in the MAA+CS capillary. With the addition of 80% MeOH into the phosphate buffer, the chiral separation of (±)-catechin was accomplished in a normal-phase mode. However, the new CSP has its limitations, as only two groups of α-tocopherol stereoisomers were separated. 相似文献
20.
Modelling of migration behaviour of inorganic anions in ion-exchange capillary electrochromatography
A theoretical model to explain the observed mobility of inorganic anions in capillary electrochromatography (CEC) using ion-exchange (IE) stationary phases has been derived. The model divides contributions to the observed mobility of an analyte ion into capillary electrophoretic (CE) and IE components. The CE component includes the influence of varying the ionic strength of the background electrolyte on the electrophoretic mobility of the analyte, while the IE component accounts for the variation in retention of the analyte ion caused by changing the composition of the background electrolyte. The model was verified using a mixture of UV-absorbing inorganic ions in electrolytes of differing eluotropic strength in both packed and open-tubular CEC systems, with excellent agreement (r2 > 0.98) for both systems. Values of constants in the model equation determined by nonlinear regression were used to estimate the relative strengths of the interactions of different analytes with the stationary phase and these were found to agree well with elution orders observed in conventional IE chromatography. 相似文献