首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The purpose of applying a countercurrent flow to isotachophoretic migration is to increase the effective separation channel length during ITP. However, severe dispersion induced by applying a counterflow can be detrimental to ITP. This paper uses numerical simulations in a 2D axisymmetric domain to investigate the dispersion caused by a parabolic counterflow in open‐capillary ITP. Counterflow in these simulations was generated by applying a back pressure to stop the isotachophoretic stack, i.e., forming stationary ITP zones. It is found that dispersion is strongly related to analyte molecular diffusivity: R‐phycoerythrin, due to its small diffusivity, showed ~20‐fold increase in zone width in stationary counterflow ITP, compared to ITP in the absence of counterflow, while fluorescein only had ~10% increase in zone width under similar operating conditions. Applying the Taylor–Aris dispersion formula in counterflow ITP simulations provided only a rough estimate of the dispersion, e.g., overestimation of analyte zone widths. Experiments on counterflow ITP were conducted in a silica capillary that was covalently and dynamically coated to exclude electroosmosis effect. The counterflow was generated by adjusting the relative height of the fluids in the two reservoirs at the capillary ends. Good qualitative agreement between simulations and experiments was found.  相似文献   

2.
Dynamic computer simulation data are compared for the first time with CE data obtained with a laboratory made system comprising an array of 8 contactless conductivity detectors (C4Ds). The experimental setup featured a 50 μm id linear polyacrylamide (LPA) coated fused‐silica capillary of 70 cm length and a purpose built sequential injection analysis manifold for fluid handling of continuous or discontinuous buffer configurations and sample injection. The LPA coated capillary exhibits a low EOF and the manifold allows the placement of the first detector at about 2.7 cm from the sample inlet. Agreement of simulated electropherograms with experimental data was obtained for the migration and separation of cationic and anionic analyte and system zones in CZE configurations in which EOF and other column properties are constant. For configurations with discontinuous buffer systems, including ITP, experimental data obtained with the array detector revealed that the EOF is not constant. Comparison of simulation and experimental data of ITP systems provided the insight that the EOF can be estimated with an ionic strength dependent model similar to that previously used to describe EOF in fused‐silica capillaries dynamically double coated with Polybrene and poly(vinylsulfonate). For the LPA coated capillaries, the electroosmotic mobility was determined to be 17‐fold smaller compared to the case with the charged double coating. Simulation and array detection provide means for quickly investigating electrophoretic transport and separation properties. Without realistic input parameters, modeling alone is not providing data that match CE results.  相似文献   

3.
This work describes a novel approach for monitoring analyte diffusion in solution that is based on electrospray ionization mass spectrometry (ESI-MS). A mass spectrometer at the end of a laminar flow tube is used to measure the Taylor dispersion of an initially sharp boundary between two solutions of different analyte concentration. This boundary is dispersed by the laminar flow profile in the tube. However, this effect is diminished by analyte diffusion that continuously changes the radial position, and hence the flow velocity of individual analyte molecules. The steepness of the resulting dispersion profile therefore increases with increasing diffusion coefficient of the analyte. A theoretical framework is developed to adapt the equations governing the dispersion process to the case of mass spectrometric detection. This novel technique is applied to determine the diffusion coefficients of choline and cytochrome c. The measured diffusion coefficients, (11.9 +/- 1.0) x 10(-10) m(2) s(-1) and (1.35 +/- 0.08) x 10(-10) m(2) s(-1), respectively, are in agreement with the results of control experiments where the Taylor dispersion of these two analytes was monitored optically. Due to the inherent selectivity and sensitivity of ESI-MS, it appears that the approach described in this work could become a valuable alternative to existing methods for studying diffusion processes, especially for experiments on multicomponent systems.  相似文献   

4.
This paper demonstrates a simple and easy setting up of a fused‐silica capillary‐assembled microfluidic system (μCE). This system incorporates a split‐flow pressure injection of the sample into a microfluidic system made from PDMS and a short (~20 cm) length of fused‐silica capillary as a separation unit. The on‐capillary detection was carried out by fiber optic spectrometry. A mixture of six cephalosporin antibiotics was separated in the μCE system and the obtained results were compared to those achievable by conventional CE. The six components could be separated within 8.5 min with the number of theoretical plates around 10 000.  相似文献   

5.
For separation of enantiomers in presence of a chiral selector, data obtained with the 1D dynamic simulators SIMUL5complex and GENTRANS are compared to data predicted by PeakMaster 6, a recently released generalized model of the linear theory of electromigration. Four electrophoretic systems with stereoisomers of weak bases were investigated. They deal with the estimation of input data for complexation together with the elucidation of the origin of observed system peaks, the interference of analyte and system peak migration, the change of enantiomer migration order as function of the selector concentration and the inversion of analyte migration direction in presence of a multiply negatively charged selector. For all systems, data predicted with PeakMaster 6 are in agreement with those of the dynamic simulators and simulation data compare well with experimental data that were monitored with setups featuring conductivity and/or UV absorbance detection along the capillary. SIMUL5complex and GENTRANS provide the full dynamics of any buffer and sample arrangement and require very long execution time intervals. PeakMaster 6 is restricted to conventional CZE, is based on an approximate solution of the transport equations, provides data for realistic experimental conditions within seconds and represents a practical tool for an experimentalist.  相似文献   

6.
In this study, we report the design of a microchip‐based hydraulic pump that comprises three glass conduits arranged in a T‐geometry, one of which has a 2 mm long segment shallower (0.5–3 μm in depth) than the remaining 15 μm deep microfluidic network. Upon application of an electric field across this microchannel junction, a mismatch in EOF rate is introduced due to a differential in the fluid conductivity across the deep and shallow segments. Using the reported micropump, pressure‐driven velocities up to 3.2 mm/s have been generated in a 15 μm deep separation channel for an applied voltage of 1.75 kV allowing us to operate under separation conditions that yield the minimum plate height. Moreover, we have shown that this flow velocity can be maximized by optimizing the depth in the shallow region of the T‐geometry. Interestingly however, a simple theory accounting for fluid conductivity differences across microchannels of different depths significantly underestimates the pressure‐driven velocities observed in our experiments. The Taylor dispersion coefficient in our system on the other hand compares well with the theoretical predictions reported in the literature. Finally, the functionality of our device has been demonstrated by implementing a reverse‐phase chromatographic separation that was driven by the pressure‐driven flow generated on‐chip.  相似文献   

7.
This study reports a reinvestigation of background electrolyte selection strategy for performance improvement in CE‐LIF of peptides and proteins. This strategy is based on the employment of high concentrations of organic species in BGE possessing high buffer capacity and low specific conductivity in order to ensure excellent stacking preconcentration and separation resolution of fluorescently tagged peptides and proteins. Unlike universal UV detection, the use of such BGEs at high concentrations does not lead to degradation of LIF detection signals at the working excitation and emission wavelengths. At the same buffer ionic strength, pH and electric field, an “inorganic‐species‐free” BGE (or ISF BGE) for CE‐LIF of fluorescently labeled beta amyloid peptide Aβ 1–42 (a model analyte) offered a signal intensity and peak efficiency at least three‐times higher than those obtained with a conventional BGE normally used for CE‐LIF, while producing an electric current twice lower. Good peak performance (in terms of height and shape) was maintained when using ISF BGEs even with samples prepared in high‐conductivity phosphate buffer saline matrix. The advantageous features of such BGEs used at high concentrations over conventional ones in terms of high separation resolution, improved signal intensities, tuning of EOF magnitudes and minimization of protein adsorption on an uncoated fused silica capillary are demonstrated using Alexa‐488‐labelled trypsin inhibitor. Such BGE selection approach was applied for investigation of separation performance for CE‐LIF of ovalbumin labelled with different fluorophores.  相似文献   

8.
Use of a square‐wave potential program for time‐dependent amperometric detection of analyte zones in capillary electrophoresis (CE) is described. Electrochemical detection for CE requires that the separation field be isolated from that of the electrochemical detection. This is generally done by physically separating the CE separation field from that of the detection. By applying a time variant potential program to the detection electrode, the detector current has a time dependence that can be used to help isolate the electrochemical detection current from that of the separation. When using a 20 μm inner‐diameter capillary, we find that a square‐wave potential program decreases the RMS baseline current from 4.5×10?10 A, found with a constant potential amperometric detection, to 1.1×10?10 A when using a square‐wave potential program. With a 75 μm inner‐diameter capillary, the improvement is even more dramatic, from 2.3×10?9 A with amperometric detection to 2.06×10?10 A when using a 1 Hz square‐wave potential program. When not using the time‐dependent detection with the 75 μm capillary, the analyte zones were beneath the S/N for the system and not detected. With the square‐wave potential program and time‐dependent detection, however, the analyte zones for an electrokinetic injection of 200 μM solution of 2,3‐dihydroxybenzoic acid were observed with the 75 μm inner‐diameter capillary. The improvement in the ability to discriminate the analytical signal from the background found experimentally is consistent with modeling studies.  相似文献   

9.
In this work, a new technique for off-line hyphenation between CE and MALDI-MS is presented. Two closed fused-silica capillaries were connected via a silicon chip comprising an open microcanal. The EOF in the system was evaluated using mesityloxide or leucine-enkephalin as a sample and with a running buffer that rendered the analyte neutrally charged. Comparison was made between the EOF in a closed system (first capillary solely included in the electrical circuit) and in a closed-open system (first capillary and microcanal included in the electrical circuit). It was concluded that the experimental values of the EOF agreed with the theory. The influence of the capillary outer diameter on the peak dispersion was investigated using a closed-open-closed system (first capillary, microcanal and second capillary included in the electrical circuit). It was clearly seen that a capillary with 375 microm od induced considerably higher peak dispersion than a 150 microm od capillary, due to a larger liquid dead volume in the connection between the first capillary outlet and the microcanal. Mass spectrometric analysis has also been performed following CE separation runs in a closed-open-closed system with cytochrome c and lysozyme as model proteins. It was demonstrated that a signal distribution profile of the separated analytes could be recorded over a 30 mm long microcanal.  相似文献   

10.
A mathematical model developed for aqueous solutions and adapted to methanol as solvent was applied to predict the electromigration characteristics of analytes and background electrolytes in capillary zone electrophoresis. These characteristics are the effective mobility, and the tendency of the analyte to undergo peak-broadening due to electromigration dispersion. The input parameters for calculation like limiting mobilities and dissociation constants were experimentally determined or taken from the literature. By the aid of the model, the molar response for conductivity detection was calculated as well as the transfer ratio when indirect UV detection was used. They allow depicting the electropherogram by computer simulation. An additional important program output is the prediction of the occurrence of system- or eigenpeaks that mimic peaks of analytes or electroosmotic flow markers. The measured electropherograms were in agreement with those theoretically predicted. Deviations were attributed to ion pairing in methanolic solutions, which was not implemented in the model.  相似文献   

11.
This study describes stationary counterflow isotachophoresis (ITP) in a poly(acrylamide‐co‐N,N′‐methylenebisacrylamide) monolithic column as a means for improving ITP processing capacity and reducing dispersion. The flow profile in the monolith was predicted using COMSOL's Brinkman Equation application mode, which revealed that the flow profile was mainly determined by monolith permeability. As monolith permeability decreases, the flow profile changes from a parabolic shape to a plug shape. An experimental monolithic column was prepared in a fused‐silica capillary using an ultraviolet‐initiated polymerization method. A monolithic column made from 8% (wt.) monomer was chosen for the stationary counterflow ITP experiments. Counterflow ITP in the monolithic column showed undistorted analyte zones with significantly reduced dispersion compared to the severe dispersion observed in an open capillary. Particularly, for r‐phycoerythrin focused by counterflow ITP, its zone width in the monolithic column was only one‐third that observed in an open capillary. These experiments demonstrate that stationary counterflow ITP in monoliths can be a robust and practical electrofocusing method.  相似文献   

12.
The system peaks that often appear on electropherograms in anion separation by CE with indirect spectrophotometric detection, negative voltage polarity and cathodic EOF are studied. The system peaks are shown to correspond to the zones with the changed concentration of the BGE constituents; they appear while the zone of each analyte anion passes through the outlet end of the capillary and are transported to the detector by EOF. An equation is suggested for predicting migration times of the system peaks with an error of 1%. The ratios of the system peak area to the analyte peak area are found to amount to 20%. It is shown that it is possible to avoid overlapping of the system peaks and analyte peaks by controlling the EOF velocity owing to hydrodynamic pressure. Using the mathematical simulation of CE shows that the system peaks and baseline shift can result from changing the transference numbers of the BGE ions and analyte ions at the capillary edge. The cases when the system peak may be incorrectly identified as the peak of analyte ion are considered. In order to avoid such errors, some practical recommendations are given.  相似文献   

13.
Mai TD  Hauser PC 《Electrophoresis》2011,32(21):3000-3007
It is demonstrated that a hydrodynamic flow superimposed on the mobility of analyte anions can be used for the optimization of analysis time in capillary zone electrophoresis. It was also possible to use the approach for counter‐balancing the electroosmotic flow and this works as well as the use of surface modifiers. To avoid any band‐broadening due to the bulk flow narrow capillaries of 10 μm internal diameter were employed. This was enabled by the use of capacitively coupled contactless conductivity detection, which does not suffer from the downscaling, and detection down to between 1 and 20 μM for a range of inorganic and small organic anions was found feasible. Precisely controlled hydrodynamic flow was generated with a sequential injection manifold based on a syringe pump. Sample injection was carried out with a new design relying on a simple piece of capillary tubing to achieve the appropriate back‐pressure for the required split‐injection procedure.  相似文献   

14.
An in‐capillary 2, 2‐diphenyl‐1‐picrylhydrazyl (DPPH)‐CE‐the DAD (in‐capillary DPPH‐CE‐DAD) combined with reversed‐electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β‐CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p‐coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH‐CE‐DAD method. Sensitivity was enhanced under reversed‐electrode polarity stacking mode and 10‐ to 31‐fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in‐capillary DPPH‐CE‐DAD method combined with reversed‐electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products.  相似文献   

15.
Jaros M  Soga T  van de Goor T  Gas B 《Electrophoresis》2005,26(10):1948-1953
A simple rule stating that the signal in conductivity detection in capillary zone electrophoresis is proportional to the difference between the analyte mobility and mobility of the background electrolyte (BGE) co-ion is valid only for systems with fully ionized electrolytes. In zone electrophoresis systems with weak electrolytes both conductivity signal and electromigration dispersion of analyte peaks depend on the conductivity and pH effects. This allows optimization of the composition of BGEs to give a good conductivity signal of analytes while still keeping electromigration dispersion near zero, regardless of the injected amount of sample. The demands to achieve minimum electromigration dispersion and high sensitivity in conductivity detection can be accomplished at the same time. PeakMaster software is used for inspection of BGEs commonly used for separation of sugars (carbohydrates, saccharides) at highly alkaline pH. It is shown that the terms direct and indirect conductivity detection are misleading and should not be used.  相似文献   

16.
A simple microchip CE method integrated with contactless conductivity detection was developed for the direct determination of partition coefficients of selected pharmaceuticals after phase distribution equilibrium. The equilibrium of distribution between two phases for four pharmaceuticals was performed using a 1‐octanol/water system and 1‐octanol/buffer system. During the concentration determination, several major factors affecting detection were investigated in detail for each pharmaceutical to optimize the detection sensitivity. In the optimal conditions, sufficient electrophoretic separation and sensitive detection for each target analyte can be achieved within 40 s. The two systems showed a pH‐dependent partition behavior. Moreover, the measured values showed excellent agreement with those obtained by the traditional shake‐flask method with HPLC–UV detection and literature reports, respectively. The developed method can be successfully applied to measure partition coefficient values of pharmaceuticals and requires much shorter analytical time compared to traditional methods.  相似文献   

17.
A mathematical and computational model is introduced for optimization of background electrolyte systems for capillary zone electrophoresis of anions. The model takes into account mono- or di- or trivalent ions and allows also for modeling of highly acidic or alkaline electrolytes, where a presence of hydrogen and hydroxide ions is significant. At maximum, the electrolyte can contain two co-anions and two counter-cations. The mathematical relations of the model are formulated to enable an easy algorithmization and programming in a computer language. The model assesses the composition of the background electrolyte in the analyte zone, which enables prediction of the parameters of the system that are experimentally available, like the transfer ratio, which is a measure of the sensitivity in the indirect photometric detection or the molar conductivity detection response, which expresses the sensitivity of the conductivity detection. Furthermore, the model also enables the evaluation of a tendency of the analyte to undergo electromigration dispersion and allows the optimization of the composition of the background electrolyte to reach a good sensitivity of detection while still having the dispersion properties in the acceptable range. Although the model presented is aimed towards the separation of anions, it can be straightforwardly rearranged to serve for simulation of electromigration of cationic analytes. The suitability of the model is checked by inspecting the behavior of a phosphate buffer for analysis of anions. It is shown that parameters of the phosphate buffer when used at neutral and alkaline pH values possess singularities that indicate a possible occurrence of system peaks. Moreover, if the mobility of any analyte of the sample is close to the mobilities of the system peaks, the indirect detector signals following the background electrolyte properties will be heavily amplified and distorted. When a specific detector sensitive on presence of the analyte were used, the signal would be almost lost due to the excessive dispersion of the peak.  相似文献   

18.
A pressurized liquid junction nanoelectrospray interface was designed and optimized for reliable on-line CE-MS coupling. The system was constructed as an integrated device for highly sensitive and selective analyses of proteins and peptides with the separation and spray capillaries fixed in a pressurized spray liquid reservoir equipped with the electrode for connection of the electrospray potential. The electrode chamber on the injection side of the separation capillary and the spray liquid reservoir were pneumatically connected by a Teflon tube filled with pressurized nitrogen. This arrangement provided precisely counterbalanced pressures at the inlet and outlet of the separation capillary. The pressure control system was driven by an electrically operated valve and maintained the optimum flow rate for the electrospray stability. All parts of the interface being in contact with the CEBGE, spray liquid and/or sample were made of glass or Teflon. The use of these materials minimized the electrospray chemical noise often caused by plastic softeners or material degradation. During optimization, the transfer of the separated zones between the separation and electrospray capillaries was monitored by UV absorbance and contactless conductivity detectors placed at the outlet of the separation capillary and inlet of the electrospray tip, respectively. This arrangement allowed independent monitoring of the effects of pressure, CE voltage and geometry of the liquid junction on the spreading and dilution of the separated zones after passage through the interface.  相似文献   

19.
A modified partial filling method for chiral separation of DL-lactic acid as the model chiral compound with vancomycin chloride as the chiral selector was developed by CE with contactless conductivity detection. Electrokinetic partial filling technique (EK-PFT) was used as an alternative method to the conventional hydrodynamic partial filling method. EK-PFT, in contrast to the hydrodynamic partial filling technique, allowed the removal of the chloride counterions from the chiral selector which otherwise led to poor sensitivity in conductivity detection. The baseline separation of DL-lactic acid as the model analyte was achieved in 5 min in a polyacrylamide-coated capillary. The best resolution was achieved by electrokinetic partial filling of vancomycin cations from the injection solution containing 5 mmol/L oxalate L-histidinium at pH 4.5 with 10 mmol/L vancomycin chloride. Computer simulation was used to explain the observed phenomena in the boundary between the inject vial and the capillary during the EK-PFT of vancomycin cations.  相似文献   

20.
Macka M  Johns C  Grosse A  Haddad PR 《The Analyst》2001,126(4):421-425
Isoelectric buffers are attractive for electrophoresis because of their low conductivity, and their compatibility with indirect photometric detection in capillary electrophoresis (CE) where they do not interfere with the detection by exhibiting competitive displacement of the UV-absorbing probe ion. N-carboxymethylated polyethyleneimine (CMPEI) was prepared by introducing a half molar equivalent of carboxylate groups onto a polyethyleneimine backbone. Its isoelectric point determined by conductometric titration and from the pH of its dilute aqueous solution is approx. 6.8, which allows isoelectric buffering at a lower pH compared to histidine (pI7.7). Although the isoelectric point is somewhat diffuse, as expected for a polymeric compound, it exhibits a buffering capacity at a pI point of about twice that of histidine. Studies of electroosmotic flow (EOF) profile at various pH values in fused silica capillaries showed that CMPEI adsorbs onto the fused silica wall and reverses the EOF at pH < 6.5. CMPEI was applied as a buffer in an electrolyte containing 0.5 mM of the anionic dye tartrazine used as the probe for indirect detection of anions. The separation system exhibited a stable baseline, no system peaks, separation efficiencies of up to 195,000 theoretical plates, and detection limits down to 0.2 microM or 2 amol of injected analyte.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏