共查询到20条相似文献,搜索用时 46 毫秒
1.
Hongyun Ji Meng Li Lihong Guo Hongyan Yuan Chunling Wang Dan Xiao 《Electrophoresis》2013,34(17):2546-2552
A new detector, capillary coupled with optical fiber LED‐induced fluorescence detector (CCOF‐LED‐IFD, using CCOF for short), is introduced for CE. The strategy of the present work was that the optical fiber and separation capillary were, in the parallel direction, fastened in a fixation capillary with larger inner diameter. By employing larger inner diameter, the fixation capillary allowed the large diameter of the optical fiber to be inserted into it. By transmitting an enhanced excitation light through the optical fiber, the detection sensitivity was improved. The advantages of the CCOF‐CE system were validated by the detection of riboflavin, and the results were compared to those obtained by the in‐capillary common optical fiber LED‐induced fluorescence detector (IC‐COF‐LED‐IFD, using COF for short). The LODs of CCOF‐CE and COF‐CE were 0.29 nM and 11.0 nM (S/N = 3), respectively. The intraday (n = 6) repeatability and interday (n = 6) reproducibility of migration time and corresponding peak area for both types of CE were all less than 1.10 and 3.30%, respectively. The accuracy of the proposed method was judged by employing standard addition method, and recoveries obtained were in the range of 98.0–102.4%. The results indicated that the sensitivity of the proposed system was largely improved, and that its reproducibility and accuracy were satisfactory. The proposed system was successfully applied to separate and determine riboflavin in real sample. 相似文献
2.
A highly sensitive optical fiber light-emitting diode (LED)-induced fluorescence detector for CE has been constructed and evaluated. In this detector, a violet or blue LED was used as the excitation source and an optical fiber with 40 microm OD was used to transmit the excitation light. The upper end of the fiber was inserted into the separation capillary and was situated right at the detection window. Fluorescence emission was collected by a 40 x microscope objective, focused on a spatial filter, and passed through a cutoff filter before reaching the photomultiplier tube. Output signals were recorded and processed with a computer using in-house written software. The present CE/fluorescence detector deploys a simple and inexpensive optical system that requires only an LED as the light source. Its utility was successfully demonstrated by the separation and determination of amino acids (AAs) labeled with naphthalene-2,3-dicarboxaldehyde (NDA) and FITC. Low detection limits were obtained ranging from 17 to 23 nM for NDA-tagged AAs and 8 to 12 nM for FITC-labeled AAs (S/N=3). By virtue of such valuable features as low cost, convenience, and miniaturization, the presented detection scheme was proven to be attractive for sensitive fluorescence detection in CE. 相似文献
3.
A novel fluorescence detector based on collinear scheme using a brightness light-emitting diode emitting at 470 nm as excitation source is described. The detector is assembled by all-solid-state optical-electronic components and coupled with capillary electrophoresis using on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids and small molecule peptide as test analyte were used to evaluate the detector. The concentration limit of detection for FITC-labeled phenylalanine was 10 nM at a signal-to-noise ratio (S/N) of 3. The system exhibited good linear responses in the range of 1 × 10−7 to 2 × 10−5 M (R2 = 0.999). 相似文献
4.
Profiling of erythropoietin products by capillary electrophoresis with native fluorescence detection
The potential of CE with native fluorescence detection (Flu) for the profiling of the therapeutic protein erythropoietin (EPO) was studied. EPO is a highly heterogeneous glycoprotein comprising a large number of isoforms. CE was applied to induce separation among the various glycoforms. Native Flu of EPO provided high detection selectivity yielding good signal‐to‐noise ratios and stable baselines, particularly when compared to conventional UV absorbance detection. In order to enhance EPO isoform resolution, CE was performed using a capillary with a neutral coating in combination with a simple BGE of 2.0 M acetic acid (pH 2.1). CE‐Flu analysis of the EPO biological reference preparation of the European Pharmacopeia resulted in a highly detailed glycoform profile. Migration time RSDs for selected EPO isoforms were less than 0.22% and 0.80% for intraday and interday repeatability, respectively. RSDs for relative peak intensity of the major EPO isoforms were less than 3%. The achieved resolution, migration time stability, and sensitivity allowed discrimination of different EPO products (EPO‐α and EPO‐β) based on the recorded glycoform pattern. The developed CE‐Flu method is relatively straightforward, and shows potential for quality control in biopharmaceutical production. 相似文献
5.
A simple fluorescence detector for capillary electrophoresis (CE) using a blue light-emitting-diode (LED) as excitation source is constructed and evaluated. An optical fiber was used to collect the fluorescence, and a flat end of the fiber was modified to spherical end, resulting in 50% increase of efficiency over the flat end. A simple device for optical alignment of the fibers and capillary column was designed. The concentration and mass detection limits for fluorescein were 1.8×10−7 mol l−1 and 4.3 femol, respectively. 相似文献
6.
An integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity was obtained compared with our previous work and the detection limit for fluorescein was 5 nM. Application of the detector for the analysis of FITC-labeled Ephedrine extract was demonstrated. 相似文献
7.
Feng-Bo Yang 《Talanta》2009,78(3):1155-203
In this work, a simple and low-cost miniaturized light-emitting diode induced fluorescence (LED-IF) detector based on an orthogonal optical arrangement for capillary electrophoresis (CE) was developed, using a blue concave light-emitting diode (LED) as excitation source and a photodiode as photodetector. A lens obtained from a waste DVD-ROM was used to focus the LED light beam into an ∼80 μm spot. Fluorescence was collected with an ocular obtained from a pen microscope at 45° angle, and passed through a band-pass filter to a photodiode detector. The performance of the LED-IF detector was demonstrated in CE separations using sodium fluorescein and fluorescein isothiocyanate (FITC)-labeled amino acids as model samples. The limit of detection for sodium fluorescein was 0.92 μM with a signal-to-noise ratio (S/N) of 3. The total cost of the LED-IF detector was less than $ 50. 相似文献
8.
Zhongqi Xu Toshiaki EsumiNatsuki Ikuta Takeshi Hirokawa 《Journal of chromatography. A》2009,1216(17):3602-3605
In this report aimed on further development of a high-sensitivity capillary gel electrophoresis (CGE) method for analysis of DNA fragments, we firstly explored online transient isotachophoresis (tITP) preconcentration combined with fluorescence detection (FD). The fluorescence signal (excitation: 488 nm; emission: 590 nm) was generated using the intercalating dye of ethidium bromide (EB). It was found when the leading electrolyte (LE) was injected behind the sample zone, such a special tITP mode has significant advantages to solve the bubble formation issue and to improve the analytical performance stability. Two standard DNA samples, a 50 bp DNA step ladder and the φX174/HaeIII digest, were used to evaluate the qualitative and quantitative abilities of the tITP-FD approach. A highly diluted sample (10,000-fold in the water, e.g. the φX174/HaeIII digest diluted from 500 μg/ml to the 50 ng/ml level) was enriched and detected; the LOD was down to 0.09 ng/ml for the 72 bp fragment, apparently improved more than 1000-fold in comparison with UV detection. Although the RSD of peak areas (n = 3) was around 15.5% for the sample was electrokinetically injected, good linearity of peak area response showed that the proposed method is suitable for quantitative analysis. 相似文献
9.
Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization. 相似文献
10.
11.
Chang-Zhu Yu You-Zhao He Hai-Yang Xie Yong Gao Wu-Er Gan Jun Li 《Journal of chromatography. A》2009,1216(20):4504-4509
A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm × 50-μm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6 mm at one end of both 50 μm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 μm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 μmol/L. The column efficiency was in the range from 1.0 × 105 to 2.5 × 105 plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves. 相似文献
12.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles. 相似文献
13.
Capillary electrophoresis (CE) coupled with fiber-optic light-emitting diode-induced fluorescence detection has been developed for the separation of tyrosine (Tyr) enantiomers. R(−)-4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole was used as a chiral fluorescence tagged reagent for derivatization of Tyr. The effect of pH, running buffer concentration and applied voltage on enantioselectivity has been investigated. The optimum CE conditions are 15 mmol/L borate running buffer (pH 10.5) and 14-kV applied voltage. Good reproducibility was obtained with coefficient of variation (n = 7) of migration time and peak area less than 0.2 and 2.0%, respectively. The limits of detection of d- and l-Tyr derivatives were 2.9 and 2.2 μmol/L (S/N = 3), respectively. The proposed method has been successfully applied to the determination of Tyr in a commercial amino acid oral solution. 相似文献
14.
Benturquia N Couderc F Sauvinet V Orset C Parrot S Bayle C Renaud B Denoroy L 《Electrophoresis》2005,26(6):1071-1079
Serotonin or 5-hydroxytryptamine (5-HT) is a major neurotransmitter in the central nervous system. In this work, a method for analyzing 5-HT in brain microdialysis samples using a commercially available capillary electrophoresis (CE) system has been developed. A pH-mediated in-capillary preconcentration of samples was performed, and after separation by capillary zone electrophoresis, native fluorescence of 5-HT was detected by a 266 nm solid-state laser. The separation conditions for the analysis of 5-HT in standard solutions and microdialysates have been optimized, and this method has been validated on both pharmacological and analytical bases. Separation of 5-HT was performed using a 80 mmol/L citrate buffer, pH 2.5, containing 20 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and +30 kV voltage. The detection limit was 2.5 x 10(-10) mol/L. This method allows the in vivo brain monitoring of 5-HT using a simple, accurate CE measurement in underivatized microdialysis samples. 相似文献
15.
Herein, we summarize the current status of native fluorescence detection in microchannel electrophoresis, with a strong focus
on chip-based systems. Fluorescence detection is a powerful technique with unsurpassed sensitivity down to the single-molecule
level. Accordingly fluorescence detection is attractive in combination with miniaturised separation techniques. A drawback
is, however, the need to derivatize most analytes prior to analysis. This can often be circumvented by utilising excitation
light in the UV spectral range in order to excite intrinsic fluorescence. As sensitive absorbance detection is challenging
in chip-based systems, deep-UV fluorescence detection is currently one of the most general optical detection techniques in
microchip electrophoresis, which is especially attractive for the detection of unlabelled proteins. This review gives an overview
of research on native fluorescence detection in capillary (CE) and microchip electrophoresis (MCE) between 1998 and 2008.
It discusses material aspects of native fluorescence detection and the instrumentation used, with particular focus on the
detector design. Newer developments, featured techniques, and their prospects in the future are also included. In the last
section, applications in bioanalysis, drug determination, and environmental analysis are reviewed with regard to limits of
detection. 相似文献
16.
Over the past few years, a large number of studies have been prepared that describe the analysis of peptides and proteins using capillary electrophoresis (CE) and laser-induced fluorescence (LIF). These studies have focused on two general goals: (i) development of automatic, selective and quick separation and detection of mixtures of peptides or proteins; (ii) generation of new methods of quantitation for very low concentrations (nm and subnanomolar) of peptides. These two goals are attained with the use of covalent labelling reactions using a variety of dyes that can be readily excited by the radiation from a commonly available laser or via the use of noncovalent labelling (immunoassay using a labelled antibody or antigen or noncovalent dye interactions). In this review article, we summarize the works which were performed for protein and peptide analysis via CE-LIF. 相似文献
17.
In this work, we characterize a previously synthesized multi-cationic aminopyrene-based labeling tag for oligosaccharide analysis by capillary electrophoresis with laser-induced fluorescence detection (CE/LIF). The fluorescent tag, 4,4',4''-(8-aminopyrene-1,3,6-trisulfonyl)tris(1-methylpiperazine) (APTMP), was characterized by reaction with standard maltooligosaccharides and the labeling parameters such as fluorescent tag concentration, labeling temperature, and time as well as influence of a reducing agent and its solvent were investigated in terms of labeling efficiency. The nanomolar limit of detection of CE/LIF analysis of APTMP labeled maltopentaose was determined. However, significant amount of the oligosaccharides was reduced to alditols, which negatively affects the yield and rate of the labeling reaction. Under optimized conditions, a highly reproducible labeling by multi-cationic APTMP was obtained; however, the most commonly used labeling by multi-anionic 8-aminopyrene-1,3,6-trisulfonic acid trisodium salt (APTS) is superior compared to APTMP labeling. Lower reactivity of APTMP compared to APTS can be explained by the loss of nucleophilicity induced by substitution of the sulfonate groups with more electron-withdrawing aminosulfonyl ones. On contrary, APTMP is still a promising tag for oligosaccharide labeling followed by CE-MS in a positive ion mode, which is considered to be more sensitive than MS detection of APTS in a negative ion mode. 相似文献
18.
Arráez-Román D Fernández-Sánchez JF Cortacero-Ramírez S Segura-Carretero A Fernández-Gutiérrez A 《Electrophoresis》2006,27(9):1776-1783
We constructed a simple fluorescence detector for both direct and indirect CE methods using a blue light-emitted diode (470 nm) as excitation source, a bifurcated optical fiber as a waveguide, and a CCD camera as a detector. The connection of all the components is fairly easy even for nonexperts and the use of a CCD camera improves the applicability of this detector compared to the others using PMTs because it permits the recording of 2-D electropherograms or phosphorescence measurements. This detector provides a compact, low cost, and rapid system for the determination of native fluorescence compounds which have high quantum yields by CE with direct fluorescence detection, showing an LOD of 2.6 x 10(-6) M for fluorescein; the determination of fluorescence derivative compounds by CE with direct fluorescence detection, showing an LOD of 1.6 x 10(-7) M for FITC-labeled 1,6-diaminohexane; and nonfluorescence compounds by CE with indirect fluorescence detection with an LOD of 2.7 x 10(-6) M for gallic acid. 相似文献
19.
An LIF detector was integrated into a CE system which uses a ball lens to focus the laser beam on the CE capillary. The detector employs an ellipsoid that is glued on the capillary window, to permit the collection of the fluorescence in the capillary. This 'trapped' fluorescence stays in the capillary because the angle of the silica/air interface is greater than the critical angle. The performance of this new detector setup is found to be identical to the collinear setup using the same ball lens. An application to the analysis of FITC-labeled IgG was optimized using a 14 cm effective length capillary. The LOD of an FITC-labeled IgG2 at an excitation wavelength of 488 nm was 150 pg/mL, which was 10 times better than the LOD recorded with slab gel silver staining. Using a tetramethylrhodamine (TAMRA)-labeled IgG2 and a 532 nm excitation wavelength the LOD is 50 pg/mL. The electropherograms of four different commercial FITC conjugates of IgG were studied. The presence of aggregates was observed in two samples while close kinetics of reduction was observed between free aggregates and high aggregates concentration samples. The integrated LIF detector provides an extremely powerful and convenient tool for antibody analysis and should be useful for therapeutic MAb control in pharmaceutical facilities. 相似文献
20.
A two-dimensional (2-D) separation system of coupling chromatography to electrophoresis was developed for profiling Escherichia coli metabolites. Capillary liquid chromatography (LC) with a monolithic silica-octadecyl silica column (500 x 0.2 mm ID) was used as the first dimension, from which the effluent fractions were further analyzed by capillary electrophoresis (CE) acting as the second dimension. Field-enhanced stacking was selectively employed as a concentration strategy to interface the two dimensions, which proved to be beneficial for the detection of metabolites. An artificial sample containing 118 standards, some of which lack chromophores or have weak UV absorbance, was used to optimize the 2-D separation system. Under the optimum conditions, 63 components in the artificial sample having absorbance at 254 nm could be well resolved and detected. The utility of the system was demonstrated by comprehensive analysis of E. coli metabolites. Comparing with the previous 2-D separation system we published in Anal. Chem. 2004, 76, 1419-1428, using a longer monolithic column in the first dimension improved the separation efficiency and offered the possibility of increasing the injection volume without compromising the separation efficiency. In the second dimension, field-enhanced stacking was used to improve the concentration sensitivity of the metabolites, and more metabolites in E. coli cell extract were detected and identified using the developed 2-D separation system. In addition, preliminary investigation for future CE-mass spectrometry coupling was also made in the study by using volatile buffers in the capillary LC and CE techniques. 相似文献