首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rapid and efficient enantioseparation of halogen aryl alcohols and β‐blockers propranolol and pindolol in packed bed CEC (p‐CEC) using as‐prepared submicron porous silica chiral stationary phases (CSPs) has been achieved. Monodispersed 0.66 and 0.81 μm chiral submicron porous silica spheres were prepared using tetramethoxysilane and hexadecyltrimethylammonium bromide, followed by a hydrothermal treatment method with ammonia–ethanol to expand the pore of silica spheres without changing their spherical morphology. A proper specific surface of ca. 230 m2/g and pore sizes average of 6–8 nm were obtained by this method. The submicron porous silica spheres were modified with mono‐6‐phenylcarbamoylated β‐CD via thiol‐en radical addition. They were packed into 9 cm 50 μm id capillary columns with photopolymerized monolithic frits. These submicron CSPs showed greater column efficiency (about 476 000 plates/m for 4‐iodophenyl‐1‐ethanol) and higher resolution than the corresponding 3 μm CSP.  相似文献   

2.
陈巧梅  柳青  申琳  薛芸  王彦  阎超 《色谱》2018,36(4):388-394
采用改良Stöber法制备420 nm亚微米单分散二氧化硅微球,采用C18硅烷化修饰后装填成毛细管色谱柱。采用该色谱柱,在加压毛细管电色谱平台上成功地实现了3对手性三唑类农药烯效唑、烯唑醇和丙环唑的同时拆分和分离。考察了各因素对手性分离效果的影响,优化后的色谱条件为:流动相为乙腈-20 mmol/L磷酸盐缓冲液(pH=6.8)(45:55,v/v),其中缓冲液中含20 mmol/L羟丙基-γ-环糊精(HP-γ-CD);泵流速为0.04 mL/min;施加电压-9.4 kV;检测波长220 nm。在上述条件下,烯效唑、烯唑醇和丙环唑3种对映体同时得到拆分和分离,相邻两峰之间的分离度依次为4.20、12.9、4.41、4.09、1.70,分离时间仅为12 min,柱效最高达到310000 plates/m。该研究为手性三唑类农药的同时分离提供了新的分离分析思路。  相似文献   

3.
Nonporous monodispersed silica spheres of 1.3 μm were coated with gold nanoparticles (AuNPs) and subsequently coated with n‐octadecanethiol. By transmission electron microscopy analysis, the average diameter of the AuNPs on the silica spheres was determined to be 12 nm. The chromatographic and electrochromatographic properties of self‐assembled n‐octadecanethiol AuNP‐coated silica microspheres (C18‐AuNPs‐SiO2) were investigated using a group of nonpolar PAHs. The stationary phase appears to display a characteristic reversed‐phase behavior. Higher separation efficiency and shorter separation times were obtained using pressurized CEC (pCEC) compared with capillary LC (CLC). A maximum column efficiency of about 2.5×105 plates per meter and less than 18 min separation time for benzene were obtained in pCEC while only 66 507 plates per meter and an analysis time of nearly 100 min were observed in CLC mode. A chemical stability test of the C18‐AuNPs‐SiO2 stationary phase under extremely high and low pH conditions demonstrated that it is stable at pH 12 and 1 for at least 60 h. The results confirm that C18‐AuNPs‐SiO2 possesses a high rigidity to withstand high packing pressures and can be used as a good stationary phase for CLC and pCEC.  相似文献   

4.
Brush‐type chiral stationary phases (CSP) have been prepared both from a silica monolith and, separately, from 10 μm porous silica beads via a process of in‐column modification including attachment of the chiral selector via copper‐catalyzed azide–alkyne cycloaddition. Azide functionalities were first introduced on the pore surface of each type of support by reaction with 3‐(azidopropyl)trimethoxysilane, followed by immobilization of a proline‐derived chiral selector containing an alkyne moiety. This functionalization reaction was carried out in dimethylformamide (DMF) in the presence of catalytic amounts of copper (I) iodide. The separation performance of these triazole linked stationary phases was demonstrated in enantioseparations of four model analytes, which afforded separation factors as high as 11.4.  相似文献   

5.
A chiral capillary monolithic column for enantiomer separation in capillary electrochromatography was prepared by coating cellulose tris(3,5‐dimethylphenylcarbamate) on porous glycidyl methacrylate‐co‐ethylene dimethacrylate monolith in capillary format grafted with chains of [2(methacryloyloxy)ethyl] trimethylammonium chloride. The surface modification of the monolith by the photografting of [2(methacryloyloxy)ethyl] trimethylammonium chloride monomer as well as the coating conditions of cellulose tris(3,5‐dimethylphenylcarbamate) onto the grafted monolithic scaffold were optimized to obtain a stable and reproducible chiral stationary phase for capillary electrochromatography. The effect of organic modifier (acetonitrile) in aqueous mobile phase for the enantiomer separation by capillary electrochromatography was also investigated. Several pairs of enantiomers including acidic, neutral, and basic analytes were tested and most of them were partially or completely resolved under aqueous mobile phases. The prepared monolithic chiral stationary phases exhibited a good stability, repeatability, and column‐to‐column reproducibility, with relative standard deviations below 11% in the studied electrochromatographic parameters.  相似文献   

6.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

7.
A novel cellulose tris(N‐3,5‐dimethylphenylcarbamate) (CDMPC) chiral stationary phase (CSP) was prepared by coating CDMPC on TiO2/SiO2, which was prepared by coating titania nanoparticles on silica through a self‐assemble technique. At first, 2‐hydroxyl‐phenyl acetonitrile and α‐phenylethanol were separated on this new CSP to evaluate the chiral separation ability. Then, two pesticides, matalaxyl and diclofop‐methyl were separated. The influence of the mobile phase composition on the enantioselectivity was discussed, and the repeatability and stability of the CSP were studied too.  相似文献   

8.
This study investigates the ability of functionalized multiwalled carbon nanotubes (MWCNTs) for enantio‐separation of metoprolol chiral forms. 2Hydroxypropyl‐β‐cyclodextrin (2HP‐β‐CD) was applied as a chiral selector to functionalize carbon nanotubes (CNTs). The modified multiwalled CNT samples were characterized using scanning electron microscopy and Fourier transform infrared spectroscopy. The results of analyses showed that CNTs were successfully cross‐linked with 2HP‐β‐CD. To evaluate the enantio‐separation property of the products, the separation of metoprolol chiral forms on the initial and final products was examined. Further, UV–visible spectroscopy and polarimeter analyses were used for characterization. The results indicate that MWCNT does not have any intrinsic enantio‐separation ability, although its selectivity for enantio‐separation can be enhanced by cross‐linking it to 2HP‐β‐CD. Moreover, the optimal mass of adsorbent as well as optimal mass of functional groups is estimated to achieve maximum enantio‐separation efficiency. The results indicate that applying large amounts of 2HP‐β‐CD to CNTs functionalization decreases the cross‐linking efficiency, which consequently reduces enantio‐separation efficiency. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A system enabling coupling of pressurized capillary electrochromatography (pCEC) with off-column amperometric detection (AD) is reported in which conduction of the current in pCEC was achieved through a cellulose acetate-coated porous polymer joint, and the effect of the high-voltage field applied to pCEC for AD was also eliminated. Effects of supplementary pressure on the porous polymer joint and the effects on AD of capillary columns of different i.d. were investigated. The performance of the pCEC–AD system with the porous polymer joint was evaluated with phenol and hydroquinone using sulfonated stearyl methacrylate monolithic columns. The separation efficiency of the column in pCEC–AD, using the proposed off-column detection with the cellulose acetate membrane joint, was comparable with that of pCEC–UV using on-column detection. Compared with end-column detection using a 50 μm i.d. capillary column without a joint, a higher signal-to-noise ratio was achieved, even using a 100 μm i.d. capillary column with a joint. Successful separation and detection of dopamine and epinephrine were also achieved by use of this system.  相似文献   

10.
The enantio‐separations of eight 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs (2‐APA NSAIDs) were established using reversed‐phase high‐performance liquid chromatography with hydroxypropyl‐β‐cyclodextrin (HP‐β‐CD) as chiral mobile phase additive for studying the stereoselective skin permeation of suprofen, ketoprofen, naproxen, indoprofen, fenoprofen, furbiprofen, ibuprofen and carprofen. The effects of the mobile phase composition, concentration of HP‐β‐CD and column temperature on retention and enantioselective separation were investigated. With 2‐APA NSAIDs as acidic analytes, the retention times and resolutions of the enantiomers were strongly related to the pH of the mobile phase. In addition, both the concentration of HP‐β‐CD and temperature had a great effect on retention time, but only a slight or almost no effect on resolutions of the analytes. Enantioseparations were achieved on a Shimpack CLC‐ODS (150 × 4.6 mm i.d., 5 μm) column. The mobile phase was a mixture of methanol and phosphate buffer (pH 4.0–5.5, 20 mM) containing 25 mM HP‐β‐CD. This method was flexible, simple and economically advantageous over the use of chiral stationary phase, and was successfully applied to the enantioselective determination of the racemic 2‐APA NSAIDs in an enantioselective skin permeation study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The reduction of analysis time, cost, and improvement of separation efficiency are the main requirements in the development of high‐throughput assay methods in bioanalysis. It can be achieved either by ultra‐high‐performance liquid chromatography (UHPLC) using stationary phases with small particles (<2 μm) at high back pressures or by using opposite direction—monolithic stationary phases with low back pressures. The application of new types of monolithic stationary phases for UHPLC is a novel idea combining these two different paths. The aim of this work was to test the recently introduced second‐generation of monolithic column Chromolith® HighResolution for UHPLC analysis of liposoluble vitamins in comparison with core‐shell and fully porous sub‐2 μm columns with different particle sizes, column lengths, and shapes. The separation efficiency, peak shape, resolution, time of analysis, consumption of mobile phase, and lifetime of columns were calculated and compared. The main purpose of the study was to find a new, not only economical option of separation of liposoluble vitamins for routine practice.  相似文献   

12.
A novel cyclodextrin intermediate, mono‐2A‐allylcarbamido‐2A‐deoxy‐permethylated β‐cyclodextrin, was synthesized by reacting allylamine and newly prepared mono‐2A‐azido‐2A‐deoxy‐permethylated β‐cyclodextrin by the Staudinger reaction and anchored onto porous silica beads by a one‐pot hydrosilylation and immobilization procedure to afford a novel chiral stationary phase. This stationary phase acts as a new member of the previous chiral stationary phase series immobilized on the cyclodextrin C2 position. This stationary phase depicted enantiomeric separation abilities toward a series of bicyclic and tricyclic racemates under reversed‐phase conditions. The resolutions for hesperetin and naringenin achieved on the current phase reached 3.91 and 1.11, respectively, much higher than the previous permethylated β‐cyclodextrin with the linkage at the C6 position.  相似文献   

13.
Pressure‐assisted CEC (pCEC) can either be performed on a CE instrument by adding pressure at the column inlet, or by applying voltage on a capillary liquid chromatography system. This study investigates the pressure's added value in pCEC using an LC instrument as well as the influence of the polymerization‐mixture composition on monolithic columns in such experimental circumstances. Two factors of the polymerization mixture, which is used to prepare the monolithic capillary columns, were varied according to an experimental design approach: the pore‐forming solvent/total monomer ratio and the pore‐forming solvents composition. Initially, the effect of the resulting stationary phase on the elution behavior of mainly pharmaceutical compounds was studied. Four responses were used to evaluate the effects on the chromatography: retention time, retention factor, peak asymmetry and number of theoretical plates. After processing the results, the stationary phase composition with the best chromatographic behavior was determined and tested. The advantageous properties of this stationary phase compared with the design center‐point column were demonstrated. Secondly, the results of these pCEC experiments were compared with those generated in an identical experimental setup previously performed using CEC. Chromatographic conditions were chosen so that the center‐point column showed similar retention in CEC and pCEC. The expected advantage (faster analysis) and drawback (decreased efficiency) of pCEC in the analysis of pharmaceuticals was evaluated. Analysis time and efficiency were both found to depend greatly on the porosity of the column. The conclusion of this comparison is that pCEC did not have a significant added value to CEC. However, this was mainly due to the instrument's limitation of the pressure‐driven flow over the column. A clear benefit of the pCEC setup was apparatus‐related, i.e. the presence of a loop injection system on the pCEC instrument, which avoids the injection problems that were occasionally observed in CEC.  相似文献   

14.
《Electrophoresis》2018,39(2):348-355
A new single‐urea‐bound chiral stationary phase based on 3,5‐dimethylphenylcarbamoylated β‐cyclodextrin was prepared through the Staudinger reaction of mono (6A‐azido‐6A‐deoxy)‐per(3,5‐dimethylphenylcarbamoylated) β‐cyclodextrin and 3‐aminopropyl silica gel under CO2 atmosphere. The new phase exhibited good enantioseparation performance for 33 analytes using normal‐phase HPLC conditions; 19 of them were baseline separated. Effects of structure of analytes, alcoholic modifiers, and acidic/basic additives on separation performances of this new cyclodextrin chiral stationary phase have been studied in detail. The results showed that the retention and resolution of acidic and basic analytes on the CSP were greatly affected by the additives. Peak symmetry for some analytes could be improved by simultaneously adding acidic and basic additives to the mobile phase. This work expands the potential applications of the cyclodextrin‐based chiral stationary phases in the normal‐phase HPLC.  相似文献   

15.
Amylose tris(3,5-dimethylphenylcarbamate) (ADMPC) coated on a kind of small particle silica gel was prepared. On this ADMPC chiral stationary phase (CSP), the direct enantiomeric separation of six novel chiral transition metal tetrahedral clusters has firstly been achieved using n-hexane as the mobile phase containing various alcohols as modifiers. The effect of mobile phase modifiers and the structural variation of the solutes on their retention factors (k‘) and resolutions (Rs) were investigated. The result suggests that not only the structure and concentration of alcohol in mobile phase, but also the structural differences in racemates can have a pronounced effect on enantiomeric separation. ADMPC-CSP is a suitable CSP for the optical resolution of chiral tetrahedral cluster by HPLC.  相似文献   

16.
胡静  刘让东  王薇薇  王彦  闫超 《色谱》2019,37(5):551-557
采用改良Stöber法合成580 nm亚微米单分散的二氧化硅微球,并以此为基质,通过"巯基-烯"点击化学反应将半胱氨酸成功键合到修饰有乙烯基团的二氧化硅微球表面,合成了一种新型亚微米亲水作用固定相(Cys-VTMS-SiO2)。采用高压匀浆法制备了新型亚微米亲水色谱填充柱,通过不同乙腈比例、缓冲盐浓度和pH条件下对甲苯、丙烯酰胺和硫脲的分离分析揭示其亲水机理。依托加压毛细管电色谱平台,成功实现了对核苷、酚类、胺类及多肽等亲水性物质的快速有效分离,其有望应用于其他强极性和亲水性化合物的分离分析。  相似文献   

17.
The screening conditions of an existing column and mobile phase selection strategy for chiral compounds in normal‐phase high performance liquid chromatography (NP‐HPLC) were tested for their applicability on Chiralpak IC, which is a chiral stationary phase (CSP) made by immobilising cellulosic tris (3,5‐dichlorophenyl‐carbamate) on silica gel. In this study, the applicability of the optimization steps of the existing separation strategy was examined using 36 compounds representing the three possible resolution situations that occur after screening. The cumulative number of separated compounds is 27 (75.0 %), and the cumulative number of baseline separated compounds is 19 (52.8 %).  相似文献   

18.
An open tubular molecule imprinted polymer (OT‐MIP) capillary column has been prepared for chiral separation of ofloxacin enantiomers in CEC. The S‐ofloxacin imprinted OT column was fabricated by thermally initiated non‐covalent polymerization procedure inside a pretreated and silanized fused silica capillary. The template molecule was incorporated with methacrylic acid (MAA), ethylene glycol dimethacrylate (EDMA) and 4‐styrenesulfonic acid (4‐SSA) and dissolved in a porogen mixture of ACN/2‐propanol (9:1). The separation efficiency of the 4‐SSA MIP column was found quite better than that of the MIP column without 4‐SSA. It has been demonstrated that our OT‐MIP column can separate ofloxacin enantiomers with excellent chiral separation efficiency after tuning the various chromatographic conditions. The optimized chromatographic eluent was 85:15, v/v%, ACN/60 mM sodium acetate at pH 7. The separation efficiency and selectivity of chiral separation of this study were far better than those obtained by previous methods for chiral separation of R‐ and S‐ofloxacin.  相似文献   

19.
A practical chiral CE method, using sulfated‐β‐CD as chiral selector, was developed for the enantioseparation of glycopyrrolate containing two chiral centers. Several parameters affecting the separation were studied, including the nature and concentration of the chiral selectors, BGE pH, buffer type and concentration, separation voltage, and temperature. The separation was carried out in an uncoated fused‐silica capillary of (effective length 40 cm) × 50 μm id with a separation voltage of 20 kV using 30 mM sodium phosphate buffer (pH 7.0, adjusted with 1 M sodium hydroxide) containing 2.0% w/v sulfated‐β‐CD at 25°C. Finally, the method for determining the enantiomeric impurities of RS‐glycopyrrolate was proposed. The method was further validated with respect to its specificity, linearity range, accuracy and precision, LODs, and quantification in the expected range of occurrence for the isomeric impurities (0.1%).  相似文献   

20.
Metal–organic frameworks are promising porous materials. Chiral metal–organic frameworks have attracted considerable attention in controlling enantioselectivity. In this study, a homochiral metal–organic framework [Co2(D‐cam)2(TMDPy)] (D‐cam = d ‐camphorates, TMDPy = 4,4′‐trimethylenedipyridine) with a non‐interpenetrating primitive cubic net has been used as a chiral stationary phase in high‐performance liquid chromatography. It has allowed the successful separation of six positional isomers and six chiral compounds. The good selectivity and baseline separation, or at least 60% valley separation, confirmed its excellent molecular recognition characteristics. The relative standard deviations for the retention time of run‐to‐run and column‐to‐column were less than 1.8 and 3.1%, respectively. These results demonstrate that [Co2(D‐cam)2(TMDPy)] may represent a promising chiral stationary phase for use in high‐performance liquid chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号