首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 351 毫秒
1.
This study describes a fast and simple methodology for the preparation of Cerium (III) Hexacyanoferrate (II) (CeHCF) nanoparticles (NPs). The NPs were characterized by fourier transform infrared (FTIR), x‐ray diffraction (XRD), scanning electron microscopy (SEM) and cyclic voltammetry (CV). The CeHCF cyclic voltammogram indicate a well‐defined redox pair assigned as Fe2+/Fe3+ in the presence of cerium (III), with a formal potential of Eθ′=0.29 V (v=100 mV s?1, KNO3; 1.0 mol/L, pH 7.0). The carbon paste electrode modified with CeHCF (CeHCF‐CPE) was applied to the catalytic electrooxidation of dopamine applying Differential Pulse Voltammetry (DPV). DPV showed linear response at two concentration ranges, from 9.0×10?7 to 8.0×10?6 and 9.0×10?6 to 1.0×10?4 mol/L, with an LOD of 1.9×10?7 and 1.0×10?5 mol/L, respectively. The CeHCF‐CPE exhibited selectivity against substances commonly found in biological samples, with redox potentials close to that of dopamine, such as urea and ascorbic acid (AA). Subsequently the CeHCF‐CPE was successfully applied to the detection of dopamine in simulated urine samples, with recovery percentages ranging between 99 and 103%.  相似文献   

2.
Prussian blue analogue nanoparticles doped with Ce(III) (CeHCF) have been synthesized using chitosan (CS) and poly(diallyldimethylammonium chloride) (PDDA) as protective matrix and were cast onto a glassy carbon electrode surface directly. Transmission electron microscopy, UV‐Vis absorption spectroscopy and resonance Rayleigh scattering technique were employed to characterize the PB analogue nanoparticles protected with CS and PDDA. Compared with the bare glassy carbon electrode, the modified electrode exhibited excellent performances for determining H2O2. This work demonstrates the feasibility of the CS‐PDDA‐CeHCF nanoparticles modified glassy carbon electrode for practical sensing applications.  相似文献   

3.
《Electroanalysis》2017,29(4):1022-1030
The proposed chemically modified electrode was graphene oxide that was synthesized via Hummer's method followed by reduction of antimony film by in‐situ electrodeposition. The experimental process could be concluded in three main steps: preparation of antimony film, reduction of analyte ions on the electrode surface and stripping step under the conditions of square wave anodic stripping voltammetry (SWASV). A simple and rapid approach was developed for the determination of heavy metals simultaneously based on a sequential injection (SI), an automated flow‐based system, coupled with voltammetric method using antimony‐graphene oxide modified screen‐printed carbon electrode (SbF‐GO‐SPCE). The effects of main parameters involved with graphene oxide, antimony and measurement parameters were also investigated. Using SI‐SWASV under the optimal conditions, the proposed electrode platform has exhibited linear range from 0.1 to 1.5 M. Calculated limits of detection were 0.054, 0.026, 0.060, and 0.066 μM for Cd(II), Pb(II), Cu(II) and Hg(II), respectively. In addition, the optimized method has been successfully applied to determine heavy metals in real water samples with acceptable accuracy of 94.29 – 113.42 % recovery.  相似文献   

4.
Boron‐doped Diamond (BDD) electrode has become one of the important tools for heavy metal detection. By studying some analytical parameters of DPASV method, like deposition time and potential in different electrolyte concentrations (acetate buffer), the conditions for detecting very low metal ion levels (Zn, Cd, Pb, and Cu) could be chosen. Diluted electrolyte (0.01 M buffer) was one of the factors favoring low detection and quantification limits, but its quantification range is short in comparison to more concentrated media. For ?1.7 V deposition potential, the detection of single metal at ppb levels was reached in 60 s deposition time. Understanding different metal‐metal interactions shows the limits to the simultaneous determination of heavy metals at BDD. Quantification was possible for the simultaneous determination of Zn, Cd and Pb despite the overlapping of Zn and Cd peaks. The performance of the BDD was compared with that of another C‐based solid electrode: the glassy carbon electrode (without mercury plating). A lower base line current, wider potential range, higher sensitivity (3 to 5 times higher than GC) and longevity of the material were noticed for the BDD.  相似文献   

5.
采用电化学沉积法将铁氰化铈(CeHCF)薄膜修饰于玻碳电极(GCE)表面,得到铁氰化铈薄膜修饰玻碳电极;将血红蛋白(Hb)固载于该修饰电极表面,成功制得了Hb/CeHCF/GCE过氧化氢生物传感器.考察了铁氰化铈薄膜修饰玻碳电极的氧化还原机理和制备条件,并对血红蛋白在电极上的电子传递过程进行了较为深入的研究.结果表明,铁氰化铈薄膜为血红蛋白提供了温和的固载环境,可实现血红蛋白与电极表面的直接电子转移,提高了血红蛋白的电化学活性;所制得的传感器对过氧化氢具有较高的催化响应和较强的稳定性.相关研究结果在生物医学和临床医学领域具有一定的借鉴意义.  相似文献   

6.
《Analytical letters》2012,45(7):1289-1298
Abstract

Poly (acridine orange) (PAO) film–modified electrode was prepared by the electrooxidation of Acridine orange on a glassy carbon electrode (GCE) for the detection of hydroquinone in the presence of o‐hydroquinone and m‐hydroquinone. The electrochemical behavior of hydroquinone on the modified electrode was investigated with respect to different solution acidity, scan rate, and accumulation time. A pair of sharp and well‐defined peaks was obtained at 0.45 and 0.42 V [vs. a saturated calomel electrode (SCE)] at the PAO film–modified electrode. The potential difference between this pair of cathodic and anodic peaks was decreased to only 30 mV as compared to the 241 mV that was obtained on the bare glassy carbon electrode (GCE). As to o‐hydroquinone and m‐hydroquinone, their corresponding oxidation peaks appeared at 0.55 V and 0.89 V (vs. SCE), respectively. The oxidation potential differences between these three isomers enabled the separate detection of hydroquinone. Under the optimum experimental situation, the oxidation peak current of hydroquinone was proportional to the concentration at the range of 6.8×10?7–9.6×10?5 M. The detection limit was been estimated as 3×10?7 M with 130 s accumulation. This method was applied to the hydroquinone detection in tap water samples.  相似文献   

7.
A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg2+, Pb2+, Cd2+, Cu2+, and Zn2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, "cleaning" solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 microg L(-1). The precision of determination was satisfactory for the respective concentration level.  相似文献   

8.
《Electroanalysis》2017,29(11):2444-2453
Heavy metals, being one of the most toxic and hazardous pollutants in natural water, are of great public health concern. Much effort is still being devoted to the optimization of the electroanalytical methods and devices, particularly for the development of novel electrode materials in order to enhance selectivity and sensitivity for the analysis of heavy metals. The ability of 3D‐printing to fabricate objects with unique structures and functions enables infinite possibilities for the creation of custom‐made electrochemical devices. Here, stainless steel 3D‐printed electrodes (3D‐steel) have been tested for individual and simultaneous square wave anodic stripping analysis of Pb and Cd in aqueous solution. Electrodeposition methods have also been employed to modify the steel electrode surface by coating with a thin gold film (3D−Au) or a bismuth film (3D−Bi) to enhance the analytical performance. All 3D‐printed electrodes (3D‐steel, 3D−Au and 3D−Bi) have been tested against a conventionally employed glassy carbon electrode (GC) for comparison. The surface modified electrodes (3D−Au and 3D−Bi) outperformed the GC electrode demonstrating higher sensitivity over the studied concentration ranges of 50–300 and 50–500 ppb for Pb and Cd, respectively. Owing to the bismuth property of binary alloys formation with heavy metals, 3D−Bi electrode displayed well‐defined, reproducible signals with relatively low detection limits of 3.53 and 9.35 ppb for Pb and Cd, respectively. The voltammetric behaviour of 3D−Bi electrode in simultaneous detection of Pb and Cd, as well as in individual detection of Pb in tap water was also monitored. Overall, 3D‐printed electrodes exhibited promising qualities for further investigation on a more customizable electrode design.  相似文献   

9.
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb2+ and Cu2+ respectively. The technique was used for the detection of Pb2+ and Cu2+ in spiked lake water. The average recoveries of Pb2+ and Cu2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.  相似文献   

10.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

11.
《Electroanalysis》2017,29(11):2418-2422
This communication shows the improved performance of electrochemically‐reduced graphene oxide (ERGO) modified electrodes for the square‐wave voltammetric detection of cocaine (COC) and its main adulterants paracetamol (PAR), caffeine (CAF) and levamisole (LEV). The four compounds can be identified in a single voltammetric scan on the ERGO‐modified electrode with adequate resolution of peaks and increase in current (at least 2‐fold) in comparison with the unmodified electrode. Moreover, electrode fouling typically verified during the oxidation of CAF and LEV is eliminated. CAF and PAR were determined in a real COC sample and satisfactory recovery values were obtained (103 and 85 %, respectively).  相似文献   

12.
A new sensor has been developed for the simultaneous detection of cadmium, lead, copper and mercury, using differential pulse and square wave anodic stripping voltammetry (DPASV and SWASV) at a graphite–polyurethane composite electrode with SBA‐15 silica organofunctionalized with 2‐benzothiazolethiol as bulk modifier. The heavy metal ions were preconcentrated on the surface of the modified electrode at ?1.1 V vs. SCE where they complex with 2‐benzothiazolethiol and are reduced to the metals, and are then reoxidized. Optimum SWASV conditions lead to nanomolar detection limits and simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ in natural waters was achieved.  相似文献   

13.
《Electroanalysis》2017,29(10):2178-2189
The challenge of heavy metal detection for environmental, industrial and medical purposes has led to the development of many analytical techniques. Stripping voltammetry is a very sensitive electrochemical method and has been widely used for heavy metal detection. Carbon nanotubes, a well‐studied carbon material with physical and chemical properties suited for electrode material is commonly employed for sensitive and selective metal detection in electrochemistry. This article reviews the recent (2011–2016) applications of carbon nanotubes as an electrode or electrode surface modifier for heavy metals detection with stripping voltammetry.  相似文献   

14.
A 1‐[2‐hydroxynaphthylazo]‐6‐nitro‐2‐naphthol‐4‐sulfonate/ CuO nanoparticles modified carbon paste electrode (HNNSCCPE) was constructed and the electro‐oxidation of isoprenaline at the surface of the modified electrode was studied using cyclic voltammetry (CV), chronoamperometry (CHA), and square wave voltammetry (SWV). Under the optimized conditions, the square wave voltammetric peak current of isoprenaline increased linearly with isoprenaline concentrations in the range of 1.0×10?7 to 7.0×10?4 M and detection limit of 5.0×10?8 M was obtained for isoprenaline. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of isoprenaline, acetaminophen and N‐acetyl‐L‐cysteine which makes it suitable for the detection of isoprenaline in the presence of acetaminophen and N‐acetyl‐L‐cysteine in real samples.  相似文献   

15.
A novel electrochemical cell design is proposed to allow fast, reproducible and highly efficient convective transport of dissolved substances to screen‐printed electrochemical three‐electrode strips mounted on miniaturized plastic vessels, with the goal of improving detection limits in disposable electrochemical stripping field sensors. The experimental configuration has been tested for accumulation of the selected heavy metals ions Zn(II), Cd(II), and Pb(II), codeposited with bismuth ions on a carbon disk screen‐printed working electrode before detection by square wave anodic stripping voltammetry. Chemical and instrumental variables of the proposed device and associate electrochemical method were optimized. Selected parameters gave detection limits in the low ng mL?1 range with moderate deposition time (120 s). Practical applicability was tested on certified water and real samples (tap water and waste water), with acceptable results, suggesting potential usefulness for field environmental monitoring of heavy metals.  相似文献   

16.
A fullerene‐C60‐modified glassy carbon electrode has been examined for the simultaneous determination of 2′‐deoxyadenosine (2′‐dAdo) and adenine in human blood and urine using Osteryoung square‐wave voltammetry (OSWV) at pH 7.2. Compared to bare glassy carbon electrode (GCE), the modified electrode displays a shift of the oxidation potential in the negative direction with significant increase in the peak current for both the analytes. At modified electrode well‐defined anodic peaks at potential of 1248 mV and 994 mV are observed for 2′‐dAdo and adenine respectively. Linear calibration curves were obtained within the concentration range 10 nM to 100 μM for both the compounds in 0.1 M phosphate buffer solution (PBS) with the limit of detection 0.8×10?8 M and 0.95×10?8 M for 2′‐dAdo and adenine respectively. The analytical utility of the present method is demonstrated by quantitative detection of 2′‐dAdo and adenine in human urine of normal subjects as well as in patients with hepatocellular carcinoma. Interfering effect of some coexisting metabolites has also been reported.  相似文献   

17.
2‐chlorobenzoyl ferrocene, was synthesized and used to construct a modified ZnO‐CuO nanoplates modified carbon paste electrode. The electrooxidation of captopril at the surface of the modified electrode was studied. Under the optimized conditions, the square wave voltammetric (SWV) peak current of captopril increased linearly with captopril concentration in the range of 5.0×10?7 to 9.0×10?4 M and detection limit of 90.0 nM was obtained for captopril. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for captopril oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of captopril and tryptophan which makes it suitable for the detection of captopril in the presence of tryptophan in real samples.  相似文献   

18.
The electrochemical synthesis of silver nanoparticles (nano‐Ag) has been successfully carried out on glassy carbon electrode (GCE) and indium tin oxide electrode (ITO) using 1‐butyl‐3‐methylimidazolium tetrafluoroborate (BMT) as green electrolytes. Further the electrodeposited nano‐Ag modified ITO electrode has been examined using atomic force microscopy (AFM), and X‐ray diffraction studies (XRD). The electrodeposited Ag nanoparticles on ITO were found in the size range of 5 to 35 nm. The nano‐Ag film modified GCE was further coated with nafion (Nf) and BMT (1 : 1 ratio) mixture and found to be stable in BMT and in pH 7 phosphate buffer solution (PBS). The nano‐Ag/BMT‐Nf film modified GCE successfully applied for the oxygen reduction reaction in neutral pH (pH 7.0 PBS). The proposed film modified GCE successfully reduces the over potential and show well defined reduction peaks for the detection of dissolved oxygen using cyclic voltammetry (CV) and rotating disc voltammetry (RDE). The film also applied for the detection of dissolved oxygen using electrochemical impedance spectroscopic studies (EIS).  相似文献   

19.
A carbon paste electrode was modified with 2‐(4‐Oxo‐3‐phenyl‐3,4‐dihydroquinazolinyl)‐N′‐phenyl‐hydrazinecarbothioamide, magnetic core? shell Fe3O4@SiO2/MWCNT nanocomposite and ionic liquid (n‐hexyl‐3‐methylimidazolium hexafluoro phosphate). The electro‐oxidation of hydrazine at the surface of the modified electrode was studied using electrochemical approaches. This modified electrode offers a considerable improvement in voltammetric sensitivity toward hydrazine, compared to the bare electrode. Square wave voltammetry (SWV) exhibits a linear dynamic range from 7.0×10?8 to 5.0×10?4 M and a detection limit of 40.0 nM for hydrazine. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for hydrazine oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of hydrazine and phenol that makes it suitable for the detection of hydrazine in the presence of phenol in real samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号