共查询到20条相似文献,搜索用时 0 毫秒
1.
《Electroanalysis》2006,18(2):177-185
In this article, the results of some recent investigations on two types of bismuth‐modified carbon paste electrodes are presented. In the first study, the bismuth‐film carbon paste electrode (BiF‐CPE) operated in situ and employed in anodic stripping voltammetry of Cd(II) and Pb(II) at the low μg L?1 level was of interest in view of choosing the proper Bi(III)‐to‐Me(II) concentration ratios (where Me: Pb or Cd). Such optimization has resulted in significant improvement of detection limits down to 1.0 μg L?1 Cd and 0.8 μg L?1 for Pb, which allowed us to apply the BiF‐CPE for analysis of selected real samples of tap and sea water. The BiF‐CPE was also further investigated for its application in highly alkaline media. In this case, attention was focused on the complex‐forming capabilities of the OH – ions and their effect on the anodic stripping characteristics of some heavy metals (i.e. Cd, Pb, Tl) as well as upon the formation of the bismuth film itself. The last example deals with the continuing characterization of the recently introduced carbon paste electrodes modified with bismuth powder (Bi‐CPEs) which combine the advantageous properties of carbon paste material with the favorable electrochemical properties of bismuth. Three series of electrodes, differing either in the content of metallic bismuth (from 8 to 50% w/w) or in the type of the carbon powder used (two spectroscopic types of graphite and powdered glassy carbon), were compared and the respective relations to the optimal carbon paste composition evaluated. Attractive electroanalytical performance of the Bi‐CPE in anodic stripping voltammetry is demonstrated for selected model mixtures of heavy metals (Mn, Zn, Cd, Pb, Tl, and In). 相似文献
2.
Christos Kokkinos Ioannis Raptis Anastasios Economou Thanassis Speliotis 《Electroanalysis》2010,22(20):2359-2365
This work reports the trace determination of Tl(I) by square‐wave anodic stripping voltammetry (SWASV) on novel microsensors equipped with a bismuth‐film electrode (BiFE). The sensors were fabricated by a multistep microfabrication approach combining sputtering (to deposit the electrode materialm, bismuth‐ and the insulator SiO2, on the surface of a silicon wafer) and photolithography (to define the geometry of the sensor). The effect of the preconcentration time, the preconcentration potential and the SW stripping parameters were investigated. Using the selected conditions, the 3σ limit of detection was 0.6 µg L?1 of Tl(I) at a preconcentration time of 240 s and the percent relative standard deviation was 4.3 % at the 10 µg L?1 level (n=8). In order to eliminate the interference caused by Pb(II) and Cd(II), EDTA was added in the sample solution The method was successfully applied to the determination of Tl(I) in a certified lake water sample. These new sensors exhibit excellent mechanical stability and offer wide scope as mercury‐free disposable sensors for trace metal analysis. 相似文献
3.
Leandro M. de Carvalho Paulo C. do Nascimento Andrea Koschinsky Michael Bau Raquel F. Stefanello Cristiane Spengler Denise Bohrer Cristiane Jost 《Electroanalysis》2007,19(16):1719-1726
This paper describes a comparative study of the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in highly saline samples (seawater, hydrothermal fluids, and dialysis concentrates) by ASV using the mercury‐film electrode (MFE) and the bismuth‐film electrode (BiFE) as working electrodes. The features of MFE and BiFE as working electrodes for the single‐run ASV determinations are shown and their performances are compared with that of HMDE under similar conditions. It was observed that the stripping peak of Tl(I) was well separated from Cd(II) and Pb(II) peaks in all the studied saline samples when MFE was used. Because of the severe overlapping of Bi(III) and Cu(II) stripping peaks in the ASV using BiFE, as well as the overlapping of Pb(II) and Tl(I) stripping peaks in the ASV using HMDE, the simultaneous determination of these metals was not possible in highly saline medium using these both working electrodes. The detection limits calculated for the metals using MFE and BiFE (deposition time of 60 s) were between 0.043 and 0.070 μg L?1 for Cd(II), between 0.060 and 0.10 μg L?1 for Pb(II) and between 0.70 and 8.12 μg L?1 for Tl(I) in the saline samples studied. The detection limits calculated for Cu(II) using the MFE were 0.15 and 0.50 μg L?1 in seawater/hydrothermal fluid and dialysis concentrate samples, respectively. The methods were applied to the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in samples of seawater, hydrothermal fluids and dialysis concentrates. 相似文献
4.
The antimony film electrode (SbFE) was prepared ex situ for anodic and adsorptive stripping voltammetric measurement of selected heavy metal ions. The electrode revealed good linearity for Cd(II) and Pb(II) in a nondeaerated solution of 0.01 M HCl in the examined concentration range from 25 to 80 μg L?1 with limits of detection of 1.1 μg L?1 for Cd(II) and 0.3 μg L?1 for Pb(II) and an excellent reproducibility. The preplated SbFE was also preliminary tested for measuring low levels of Ni(II) using adsorptive stripping voltammetry exhibiting good linearity and sensitivity in combination with only a 30 s deposition step. 相似文献
5.
Christos Kyrisoglou Anastasios Economou Constantinos E. Efstathiou 《Electroanalysis》2012,24(9):1825-1832
This work reports the utility of an iridium microwire plated in situ with a bismuth film for the simultaneous determination of Pb(II) and Cd(II) by square‐wave anodic stripping voltammetry (SWASV). The experimental variables (concentration of the bismuth plating solution, preconcentration potential, accumulation time) were investigated. The limit of detection was 1 µg L?1 for Pb(II) and 1.5 µg L?1 for Cd(II) (at 300 s of preconcentration) and the % relative standard deviations were lower than 4.9 % and 5.5 %, respectively, at the 20 µg L?1 level (n=8). In addition, a study was made of coating the iridium‐based bismuth‐film microsensor with a film of Nafion for operation in the presence of surfactants. Finally, the electrode was applied to the determination of Pb(II) and Cd(II) in wastewater and tapwater samples. 相似文献
6.
To improve the reproducibility, stability, and sensitivity of bismuth film electrode (BiFE), we studied the performances of a mixed coating of two cation‐exchange polymers, Nafion (NA) and poly(sodium 4‐styrenesulfonate) (PSS), modified glassy carbon BiFE (GC/NA‐PSS/BiFE). The characteristics of GC/NA‐PSS/BiFE were investigated by scanning electron microscopy and cyclic voltammetry. Various parameters were studied in terms of their effect on the anodic stripping voltammetry (ASV) signals. Under optimized conditions, the limits of detection were 71 ng L?1 for Cd(II) and 93 ng L?1 for Pb(II) with a 10 min preconcentration. The results exhibited that GC/NA‐PSS/BiFE can be a reproducible and robust tool for monitor of trace metals by ASV rapidly and environmentally friendly, even in the presence of surface‐active compounds. 相似文献
7.
《Electroanalysis》2004,16(21):1745-1754
This works reports the use of adsorptive stripping voltammetry (AdSV) for the trace determination of chromium on a rotating‐disk bismuth‐film electrode (BFE). During the reductive accumulation step, all the chromium species in the sample were reduced to Cr(III) which was complexed with cupferron and the complex was accumulated by adsorption on the surface of a preplated BFE. The stripping step was carried out by using a square‐wave (SW) potential‐time voltammetric signal. Electrochemical cleaning of the bismuth film was employed, enabling the same bismuth film to be used for a series of measurements in the presence of dissolved oxygen. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for chromium was 100 ng L?1 (for 120 s of preconcentration) and the relative standard deviation was 3.6% at the 2 μg L?1 level (n=8). Finally, the method was applied to the determination of chromium in real samples with satisfactory results. 相似文献
8.
《Analytical letters》2012,45(11):2273-2284
Abstract A novel voltammetric method—anodic—using a bismuth/poly(aniline) film electrode has been developed for simultaneous measurement of Pb(II) and Cd(II) at low µg L?1 concentration levels by stripping voltammetry. The results confirmed that the bismuth/poly(aniline) film electrode offered high‐quality stripping performance compared with the bismuth film electrode. Well‐defined sharp stripping peaks were observed for Pb(II) and Cd(II), along with an extremely low baseline. The detection limits of Pb(II) and Cd(II) are 1.03 µg L?1 and 1.48 µg L?1, respectively. The bismuth/poly (aniline) electrode has been applied to the determination of Pb(II) in tap water samples with satisfactory results. 相似文献
9.
《Electroanalysis》2006,18(9):854-861
Nafion polymer coated bismuth‐film‐modified carbon film electrodes have been investigated for reducing the influence of contaminants such as surfactants in the anodic stripping voltammetry of trace metal ions. The influence of the coating on electrode response has been tested with both ex situ and in situ bismuth film deposition, with and without the polymer coating. The electrode assemblies and interfacial characteristics in the presence of the non‐ionic surfactant Triton‐X‐100 have been probed with electrochemical impedance spectroscopy. The Nafion coating successfully decreases the adsorption of Triton on the bismuth film surface, and demonstrates that this strategy allows measurement of these trace metals in environmental samples containing surfactants. 相似文献
10.
Mercury Films on Commercial Carbon Screen‐Printed Devices for the Analysis of Heavy Metal Ions: a Critical Evaluation 下载免费PDF全文
Clara Pérez‐Ràfols Núria Serrano José Manuel Díaz‐Cruz Cristina Ariño Miquel Esteban 《Electroanalysis》2015,27(6):1345-1349
The suitability of mercury films on commercial screen‐printed electrodes for the analysis of heavy metal ions is critically tested for the particular case of Pb(II)‐ions. Although determination is possible by anodic stripping voltammetry with a reasonable detection limit (8.9 µg L?1), important drawbacks are noticed as a consequence of the heterogeneous deposition of mercury on the rough surface of screen‐printed devices. 相似文献
11.
Sub‐ppt Level Detection of Mercury(II) Based on Anodic Stripping Voltammetry with Prestripping Step at an In Situ Formed Bismuth Film Modified Glassy Carbon Electrode 下载免费PDF全文
Shao‐Hua Wu Zhao‐Yan Zheng Ji‐Fang Zhang Zi‐Wang Song Lei Fang Jian‐Jun Sun 《Electroanalysis》2015,27(7):1610-1615
Sensitive and selective detection of Hg2+ in solution is a challenging work. An anodic stripping voltammetry with prestripping step at an in situ formed bismuth film modified glassy carbon electrode was proposed for detection of mercury(II) in solution. This prestripping step was able to decrease the background and improve the signal‐to‐noise ratio and thus enhance the sensitivity. With this method, highly sensitive and selective detection of Hg2+ with a ppt‐level detection limit of 0.5 ng L?1 could be achieved. Moreover, this method provides low interference, rapid and extreme simple and convenience, and hold great promise for in situ Hg2+ determination. 相似文献
12.
《Electroanalysis》2002,14(24):1707-1712
A study is presented on the characterization, evaluation and optimization of several key operational parameters for a reliable and effective use of a bismuth film electrode (BiFE) as an advanced replacement of the mercury film electrode in anodic stripping voltammetric measurements of trace heavy metals. Applying in situ preparation of the BiFE and employing lead(II) and cadmium(II) as model analyte ions, key parameters including bismuth precursor salt and substrate surface (platinum, gold, glassy carbon, carbon paste, carbon fiber) for bismuth plating, concentration as well as cationic and anionic composition of the measurement solution, solution pH and temperature, potential interferents, and stripping modes were carefully examined for their effects in the preconcentration and stripping steps. Parameters such as substrate surface (except platinum), precursor salt, solution matrix and temperature showed no or little impact on the BiFE performance in stripping analysis. On the other hand, the BiFE performance was found to be dependent on the solution pH (with maximum efficiency in the range of 4 to 5), on the stripping mode (with square‐wave voltammetry as the best choice) and to a certain degree on the presence of surface active substances. The results revealed that the non‐toxic solid‐state BiFE is applicable under a wide variety of conditions which proves it highly suitable for practical work in environmental trace heavy metal analysis. 相似文献
13.
Chen Chen Xiangheng Niu Yan Chai Hongli Zhao Minbo Lan Yonggang Zhu Gang Wei 《Electroanalysis》2013,25(6):1446-1452
This work presents a disposable bismuth‐antimony film electrode fabricated on screen‐printed electrode (SPE) substrates for lead(II) determination. This bismuth‐antimony film screen‐printed electrode (Bi‐SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi‐SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen‐printed electrodes (BiSPE), antimony film screen‐printed electrodes (SbSPE) and bismuth‐antimony film glassy carbon electrodes (Bi‐SbGC). Under optimized conditions, the Bi‐SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 µg/L. The Bi‐SbSPE has been demonstrated successfully to detect lead in river water sample. 相似文献
14.
《Analytical letters》2012,45(7):1267-1278
Abstract In this work, a new method for the simultaneous determination of Pb(II) and Cd(II) on the multiwalled carbon nanotubes (MWNT)-Nafion-bismuth modified glassy carbon electrode (GCE) using square-wave anodic stripping voltammetry has been studied. Scanning electron microscopy was used to investigate the characteristics of the MWNT-Nafion-bismuth modified GCE. Well-defined sharp stripping peaks were observed in the determination of Pb(II) and Cd(II) simultaneously on this electrode. Under optimized conditions, the lowest detectable concentrations were 50 ng/l for Pb(II) and 80 ng/l for Cd(II) under a 10 min preconcentration. The attractive performances of MWNT-Nafion-bismuth modified GCE demonstrated its application for a simple, rapid, and harmless determination of trace heavy metals. 相似文献
15.
Nikolitsa Lezi Anastasios Economou Panagiotis A. Dimovasilis Pantelis N. Trikalitis Mamas I. Prodromidis 《Analytica chimica acta》2012
In this article, a study of novel screen-printed electrodes bulk-modified with five potential bismuth precursor compounds (bismuth citrate, bismuth titanate, bismuth oxide, bismuth aluminate and bismuth zirconate) is presented for the determination of Cd(II) and Pb(II) by anodic stripping voltammetry. During the electrolytic deposition step, the precursor was reduced and served as the source of bismuth. Different key parameters were investigated in detail such as the nature of the bismuth precursor compound, the precursor content in the carbon ink, the polarisation range of the sensors, the supporting electrolyte, the stripping waveform, the deposition time, the deposition potential and the long-term stability of the sensors under continuous use. Using bismuth citrate as the precursor, the limit of detection was 0.9 μg L−1 for Pb(II) and 1.1 μg L−1 for Cd(II). The reproducibility on the same sensor (expressed as % relative standard deviation, (n = 8)) was 5.4% for Pb(II) and 7.2% for Cd(II) at the 20 μg L−1 level. Finally, the sensors were applied to the determination of Cd(II) and Pb(II) in water samples. 相似文献
16.
A novel analytical procedure for the determination of Pb(II) and Cd(II) in herbal medicines by differential pulse anodic stripping voltammetry (DPASV) on Nafion‐coated bismuth film electrode (NCBFE) was proposed and experimentally validated. Various experimental parameters, which influenced the response of the NCBFE to these metals in real samples, were optimized. The results showed that there were well‐defined peaks of Pb and Cd in herb samples at deposition potential of ?1.2 V and deposition time of 300 s. The analytical performance of the NCBFE was evaluated in the presence of dissolved oxygen, with the determination limits of 0.35 µg·L?1 for Pb and 0.72 µg·L?1 for Cd and recoveries of 87.8% –105.4% for Pb and 89.5% –108.5% for Cd obtained from different samples. The Pb and Cd concentrations in the studied samples have been also determined by graphite furnace atomic absorption spectrometry (GFAAS), suggesting that there was a satisfactory agreement between the two techniques, with relative errors lower than 6.5% in all cases. The great advantages of the proposed method over the spectroscopic method were characterized by its simplicity, selectivity and short analysis time, simultaneous analysis of different metals and cost‐efficiency. 相似文献
17.
Lab‐on‐a‐Chip Sensor with Evaporated Bismuth Film Electrode for Anodic Stripping Voltammetry of Zinc
Wenjing Kang Xing Pei Wei Yue Adam Bange William R. Heineman Ian Papautsky 《Electroanalysis》2013,25(12):2586-2594
In this work, we report on the development of a lab‐on‐a‐chip electrochemical sensor that uses an evaporated bismuth electrode to detect zinc using square wave anodic stripping voltammetry. The microscale electrochemical cell consists of a bismuth working electrode, an integrated silver/silver chloride reference electrode, and a gold auxiliary electrode. The sensor exhibits a linear response in 0.1 M acetate buffer at pH 6 with zinc concentrations in the 1–30 μM range and a calculated detection limit of 60 nM. The sensor successfully detected zinc in a bovine serum extract and the results were corfirmed by independent AAS measurements. Our results demonstrate the advantageous qualities of this lab‐on‐a‐chip electrochemical sensor for clinical applications, which include small sample volume (µL scale), reduced cost, short response time and high accuracy at low concentrations of analyte. 相似文献
18.
《Analytical letters》2012,45(7):764-773
Integrating the screen printing technique with the vacuum evaporation method, we developed a novel and disposable screen-printed gold film electrode (SPGFE) in the present work. First, a conductive silver layer, a connection graphite-carbon layer, and an insulating polymer layer were successively printed onto a flexible polyethylene terephthalate (PET) substrate. Then, a gold thin film was achieved on the scheduled vacant site by use of the vacuum evaporation method. In order to enhance the electroanalytical performance of the SPGFE, the thickness of the gold film was controlled in the range of 70–80 nm under optimum conditions. The fabricated SPGFE was applied to detect trace mercury(II) based on the square-wave anodic stripping voltammetry (SWASV). The results indicated that the proposed SPGFE exhibited higher sensitivity to trace mercury(II) than the gold disc electrode. The stripping current was linearly related to the concentration of mercury(II) in the range of 16–280 µg/L (R2 = 0.9919) and 1.2–8.0 µg/L (R2 = 0.9977), with a detection limit of 0.8 µg/L (S/N = 3) under 180 s accumulation. The SPGFE was further used to detect mercury in real samples, and the obtained results revealed a good agreement with those of inductively coupled plasma atomic emission spectrometry (ICP-AES) and atomic absorption spectroscopy (AAS). The highly sensitive and environmental friendly electrode, as another type of “mercury-free” electrode, holds great promise in stripping measurements. 相似文献
19.
Maiara Oliveira Salles Dario Battistel Alex Silva Lima Mauro Bertotti Salvatore Daniele 《Electroanalysis》2011,23(3):595-603
Scanning electrochemical microscopy (SECM) in feedback mode was employed to characterise the reactivity and microscopic peculiarities of bismuth and bismuth/lead alloys plated onto gold disk substrates in 0.1 mol L?1 NaOH solutions. Methyl viologen was used as redox mediator, while a platinum microelectrode was employed as the SECM tip. The metal films were electrodeposited ex situ from NaOH solutions containing either bismuth ions only or both bismuth and lead ions. Approach curves and SECM images indicated that the metal films were conductive and locally reactive with oxygen to provide Bi3+ and Pb2+ ions. The occurrence of the latter chemical reactions was verified by local anodic stripping voltammetry (ASV) at the substrate solution interface by using a mercury‐coated platinum SECM tip. The latter types of measurements allowed also verifying that lead was not uniformly distributed onto the bismuth film electrode substrate. These findings were confirmed by scanning electron microscopy images. The surface heterogeneity produced during the metal deposition process, however, did not affect the analytical performance of the bismuth coated gold electrode in anodic stripping voltammetry for the determination of lead in alkaline media, even in aerated aqueous solutions. Under the latter conditions, stripping peak currents proportional to lead concentration with a satisfactory reproducibility (within 5 % RSD) were obtained. 相似文献
20.
《Electroanalysis》2017,29(4):1022-1030
The proposed chemically modified electrode was graphene oxide that was synthesized via Hummer's method followed by reduction of antimony film by in‐situ electrodeposition. The experimental process could be concluded in three main steps: preparation of antimony film, reduction of analyte ions on the electrode surface and stripping step under the conditions of square wave anodic stripping voltammetry (SWASV). A simple and rapid approach was developed for the determination of heavy metals simultaneously based on a sequential injection (SI), an automated flow‐based system, coupled with voltammetric method using antimony‐graphene oxide modified screen‐printed carbon electrode (SbF‐GO‐SPCE). The effects of main parameters involved with graphene oxide, antimony and measurement parameters were also investigated. Using SI‐SWASV under the optimal conditions, the proposed electrode platform has exhibited linear range from 0.1 to 1.5 M. Calculated limits of detection were 0.054, 0.026, 0.060, and 0.066 μM for Cd(II), Pb(II), Cu(II) and Hg(II), respectively. In addition, the optimized method has been successfully applied to determine heavy metals in real water samples with acceptable accuracy of 94.29 – 113.42 % recovery. 相似文献