首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

2.
采用电氧化法制备了一种新型γ-氨基丁酸(ABA)修饰的玻碳电极.X射线光电子能谱(XPS)和循环伏安法研究表明,ABA以单分子层状态以C—N键牢固地共价键合在电极表面.该修饰电极对多巴胺(DA)、尿酸(UA)和抗坏血酸(AA)都具有良好的电化学催化特性.在pH=7.0磷酸缓冲溶液中,DA,UA和AA分别于0.45,0.25和0.07V(vs.Ag/AgCl)有一个良好的、独立的阳极方波伏安峰,表明此修饰电极可用于这3种物质的同时测定.与DA,UA和AA的方波伏安峰电流呈线性关系的浓度范围分别为4.0~400,2.0~500和1.0~600μmol/L,检测限(3δ)分别为1.6,1.2和0.8μmol/L.该修饰电极具有良好的灵敏度、选择性和稳定性,并具有抗污染能力.  相似文献   

3.
制备了聚乙烯亚胺(PEI)功能化的石墨烯(G)修饰电极以实现抗坏血酸(AA)、 多巴胺(DA)、 尿酸(UA)和色氨酸(Trp)的分离及同时测定. 采用红外光谱(FTIR)、 紫外-可见吸收光谱(UV-Vis)、 X射线粉末衍射仪(XRD)和透射电子显微镜(TEM)对电极修饰材料进行了表征, 并优化了该修饰电极同时测定AA, DA, UA和Trp的实验条件. 在聚乙烯亚胺功能化石墨烯修饰的玻碳电极(PEI-G/GCE)上实现了AA, DA, UA 和Trp氧化峰的分离, AA-DA, DA-UA和UA-Trp的氧化峰电位差分别为298, 130和350 mV. 该修饰电极对AA, DA, UA和Trp的检测线性范围分别为50~5800, 30~2570, 0.05~400和6~1000 μmol/L; 检出限分别为16.67, 10, 0.017和2 μmol/L.  相似文献   

4.
In this study, a nanocomposite of 3, 4, 9, 10‐perylenetetracarboxylic acid and L‐cysteine (PTCA‐Cys) with satisfactory water‐solubility and film‐forming ability was prepared and worked as substrate for modifying the glassy carbon electrode. Then, gold nanoparticles (AuNPs) were immobilized to achieve a PTCA‐Cys‐AuNPs modified electrode which provided more reaction positions on the sensor. Scanning electron microscopy, transmission electron microscopy, cyclic voltammetry and different pulse voltammetry were employed to characterize the assembly process of the sensor. The constructed sensor displayed desirable sensitivity, selectivity and stability towards the simultaneous detection of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Under the optimal experimental conditions, the oxidation peaks of AA, DA and UA appeared at 64, 240 and 376 mV, respectively. The corresponding linear response ranges were 3.2–435, 0.04–100 and 0.80–297 μM, and the detection limits were 1.1, 0.010 and 0.27 μM (S/N=3), respectively.  相似文献   

5.
The present study reports the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA) in phosphate buffer solution (pH 7.0) using graphene paste electrode modified with functionalized graphene sheets (GPE‐MFGSs). The presence of FGS inhibited the adsorption of AA owing to the electrostatic repulsion, but was favorable for the affinity adsorption of DA and UA via the ion exchange and hydrogen bonding mechanisms, respectively. This led to the decrease in the oxidation potential of AA and the significantly enhanced oxidation peak currents of DA and UA at the GPE‐MFGSs. By cyclic voltammetry and differential pulse voltammetry, the oxidation potentials of AA, DA, and UA, at the GPE‐MFGSs in a ternary mixture were found to be well resolved so that their simultaneous determination could be achieved. Furthermore, the influence of some experimental variables such as graphene paste composition, working solution pH, scan rate and pulse amplitude was studied. In addition, by differential pulse voltammetry, the linear dependence of peak current on the concentration was obtained in the ranges of 0.05–9.0, 0.03–13, and 0.03–5.5 µM with the lowest detection limits of 0.02, 0.01, and 0.01 µM for AA, DAand UA, , respectively.  相似文献   

6.
In this paper electropolymerization of a thin film of para‐phenylenediamine (PPD) is studied at glassy carbon electrode (GCE) in sulfuric acid media by cyclic voltammetry. The results showed that this polymer was conducting and had a reproducible redox couple in the potential region from 0.0 to 0.4 V in phosphate buffer solution. This modified GCE (p‐PPD‐GCE) was applied for simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA) using differential pulse voltammetry (DPV). The p‐PPD‐GCE in 0.1 M phosphate buffer solution (pH 5.0) separated the DPV signals of AA, DA and UA with sufficient potential differences between AA–DA and DA–UA and also enhanced their oxidation peak currents. The oxidation currents were increased from 2.0 to 2000.0 µM for AA, 10.0 to 1250.0 µM for DA and 50.0 to 1600.0 µM for UA. The detection limits were evaluated as 0.4, 1.0 and 2.5 µM for AA, DA and UA, respectively (S/N=3).  相似文献   

7.
The properties of graphite electrode (Gr) modified with poly(diallyl dimethyl ammonium chloride) (PDDA) for the detection of uric acid (UA) in the presence of dopamine (DA) and high concentration of ascorbic acid (AA) have been investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The polymer modified graphite electrode was prepared by a very simple method just by immersing the graphite electrode in PDDA solution for 20 minutes. The PDDA/Gr modified electrode displayed excellent electrocatalytic activity towards the oxidation of UA, DA and AA compared to that at the bare graphite electrode. The electrochemical oxidation signals of UA, DA and AA are well resolved into three distinct peaks with peak potential separations of 220 mV, 168 mV and 387 mV between AA‐DA, DA‐UA and AA‐UA respectively in cyclic voltammetry studies and the corresponding peak potential separations are 230 mV, 130 mV and 354 mV respectively in differential pulse voltammetry. The lowest detection limits obtained for UA, DA and AA were 1×10?7 M, 2×10?7 M and 800×10?9 M respectively. The PDDA/Gr electrode efficiently eliminated the interference of DA and a high concentration of AA in the determination of UA with good selectivity, sensitivity and reproducibility. The modified electrode was also successfully applied for simultaneous determination of UA, DA and AA in their ternary mixture.  相似文献   

8.
A facile approach for the synthesis of gold nanoparticle-loaded carbon nanofiber(Au/CNF) composites was developed. When applied to electrochemistry, these composites showed attractive performances such as high conductivity and facile electron transfer kinetics. Under physiological conditions, the Au/CNF composite modified electrode exhibits highly electrocatalytic activity for the oxidation of dopamine, ascorbic acid and uric acid. Owing to the good selectivity for the simultaneous detection of these three ...  相似文献   

9.
A modified electrode was fabricated by electrochemically deposition of Pt nanoparticles on the multiwall carbon nanotube covered glassy carbon electrode (Pt nanoparticles decorated MWCNT/GCE). A higher catalytic activity was obtained to electrocatalytic oxidation of ascorbic acid, dopamine, and uric acid due to the enhanced peak current and well‐defined peak separations compared with both, bare and MWCNT/GCE. The electrode surfaces were characterized by scanning electron microscopy (SEM), X‐ray diffraction (XRD) and electrochemical impedance spectroscopy (EIS). Individual and simultaneous determination of AA, DA, and UA were studied by differential pulse voltammetry. The detection limits were individually calculated for ascorbic acid, dopamine, and uric acid as being 1.9×10?5 M, 2.78×10?8 M, and 3.2×10?8 M, respectively. In simultaneous determination, LODs were calculated for AA, DA, and UA, as of 2×10?5 M, 4.83×10?8 M, and 3.5×10?7 M, respectively.  相似文献   

10.
《Electroanalysis》2004,16(10):866-869
Exfoliated graphite electrodes have been used to detect uric acid at neutral pHs, by following its oxidation. A linear range of 5–53 μM and a detection limit of 5 μM are observed at a pH of 7.0. Uric acid was found to be selectively adsorbed on exfoliated graphite surface in the presence of excess ascorbic acid. This leads to its selective determination in the presence of ascorbic acid. Simultaneous detection of uric acid, dopamine and ascorbic acid has also been demonstrated on exfoliated graphite electrodes in a pH 7 buffer.  相似文献   

11.
《Analytical letters》2012,45(15):2633-2643
Abstract

A new polymer (polyhistidine) modified electrode has been fabricated and was applied to the catalytic oxidation of ascorbic acid (AA), reducing the overpotential by 400 mV. The catalytic rate constant of the modified electrode for the oxidation of AA was determined using a rotating electrode. The catalytic current was linearly dependent on the ascorbic acid concentration between 5×10?5 and 2×10?3 M. The catalytic effect on the AA resulted in the separation of the overlapping voltammograms of AA and dopamine (DA) in a mixture. This allowed the determination of AA in the presence of DA. The electrode was rather stable even after several months; a reproducible response of AA was obtained.  相似文献   

12.
Uric acid (UA) was determined in the presence of ascorbic acid (AA) by using a carbon paste electrode modified superficially by a β‐cyclodextrin film (CPE/β‐CD). The surface carbon paste electrode was prepared applying a 30 cycles potential program and using a 1 M HClO4+0.01 M β‐CD electrolytic solution. The UA and AA solutions were used to evaluate the electrode selectivity and sensitivity by cyclic voltammetric and amperometric methods. In these experiments the detection limit for UA was (4.6±0.01)×10?6 M and the RSD calculated from the amperometric curves was 10%. From the data obtained it was possible to quantify UA in the urine and saliva samples. Selective detection of UA was improved by formation of an inclusion complex between β‐CD and UA. The results show that the CPE/β‐CD is a good candidate due to its selectivity and sensitivity in the UA determination in complex samples like the biological fluids.  相似文献   

13.
In this paper, a silver doped poly(L ‐valine) (Ag‐PLV) modified glassy carbon electrode (GCE) was fabricated through electrochemical immobilization and was used to electrochemically detect uric acid (UA), dopamine (DA) and ascorbic acid (AA) by linear sweep voltammetry. In pH 4.0 PBS, at a scan rate of 100 mV/s, the modified electrode gave three separated oxidation peaks at 591 mV, 399 mV and 161 mV for UA, DA and AA, respectively. The peak potential differences were 238 mV and 192 mV. The electrochemical behaviors of them at the modified electrode were explored in detail with cyclic voltammetry. Under the optimum conditions, the linear ranges were 3.0×10?7 to 1.0×10?5 M for UA, 5.0×10?7 to 1.0×10?5 M for DA and 1.0×10?5 to 1.0×10?3 M for AA, respectively. The method was successfully applied for simultaneous determination of UA, DA and AA in human urine samples.  相似文献   

14.
A gold nanoparticles modified carbon paste electrode (GN‐CPE) was used as a highly sensitive electrochemical sensor for determination of tyrosine (Tyr), dopamine (DA) and uric acid (UA) in phosphate buffer solution (PBS). The study and measurements were carried out by using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry methods. In DPV, the GN‐CPE could separate the oxidation peak potentials of DA and UA present in the same solution, though at the unmodified CPE the peak potentials were indistinguishable. The prepared electrode showed voltammetric responses with high sensitivity and selectivity for Tyr, DA and UA in optimal conditions, which makes it very suitable for simultaneous determination of these compounds. The calibration curves for Try, DA and UA were linear for the concentrations of each species. The proposed voltammetric approach was also applied to the determination of Tyr concentration in human serum as a real sample.  相似文献   

15.
聚苯胺修饰电极上抗坏血酸与多巴胺氧化峰的分离   总被引:5,自引:0,他引:5  
本文介绍一种分离抗坏血酸(AA)和多巴胺(DA)氧化峰的新方法。聚苯胺(PA)对AA和DA有不同的催化性,因而在PA修饰电极上,AA和DA在不同的电位被氧化,从而解决了二者氧化峰不能分离的问题。实验表明,在PA膜电极上,AA和DA氧化峰可分开约140mV。  相似文献   

16.
《Electroanalysis》2003,15(21):1693-1698
The voltammetric behaviors of uric acid (UA) and L ‐ascorbic acid (L ‐AA) were studied at well‐aligned carbon nanotube electrode. Compared to glassy carbon, carbon nanotube electrode catalyzes oxidation of UA and L ‐AA, reducing the overpotentials by about 0.028 V and 0.416 V, respectively. Based on its differential catalytic function toward the oxidation of UA and L ‐AA, the carbon nanotube electrode resolved the overlapping voltammetric response of UA and L ‐AA into two well‐defined voltammetric peaks in applying both cyclic voltammetry (CV) and differential pulse voltammetry (DPV), which can be used for a selective determination of UA in the presence of L ‐AA. The peak current obtained from DPV was linearly dependent on the UA concentration in the range of 0.2 μM to 80 μM with a correlation coefficient of 0.997. The detection limit (3δ) for UA was found to be 0.1 μM. Finally, the carbon nanotube electrode was successfully demonstrated as a electrochemical sensor to the determination of UA in human urine samples by simple dilution without further pretreatment.  相似文献   

17.
《Analytical letters》2012,45(16):2618-2630
A carbon paste electrode (CPE), modified with novel hydroquinone/TiO2 nanoparticles, was designed and used for simultaneous determination of ascorbic acid (AA), uric acid (UA) and folic acid (FA). The magnitude of the peak current for modified TiO2-nanoparticle CPE (MTNCPE) increased sharply in the presence of ascorbic acid and was proportional to its concentration. A dynamic range of 1.0–1400.0 μM, with the detection limit of 6.4 × 10?7 M for AA, was obtained using the DPV technique (pH = 7.0). The prepared electrode was successfully applied for the determination of AA, UA, and FA in real samples.  相似文献   

18.
制备了碳纳米管修饰电极(镶嵌、涂层),并研究了电分离多巴胺(DA)和抗坏血酸(AA)的机理.结果表明,该电极的表面有一个多孔性的立体界面层,不仅对DA和AA具有较强的电催化作用,而且二者的氧化峰电位差(ΔEpa)达250mV以上.用循环伏安法和差示脉冲伏安法研究了影响ΔEpa的因素.分散剂的种类对ΔEpa有很大的影响;多层碳纳米管的管径对ΔEpa的影响较小,碳纳米管的种类(单层、多层、螺旋型多层)则有一定的区别;同一种碳纳米管经不同氧化强度的酸截短后,对ΔEpa产生了明显影响.这说明修饰电极的界面性质对电分离DA和AA有较大的影响.  相似文献   

19.
张英  任旺  李敏娇 《电化学》2012,(1):79-83
研究柠檬酸(CA)修饰玻碳电极(CA/GC)在抗坏血酸(AA)、多巴胺(DA)和尿酸(UA)混合体系中的循环伏安(CV)行为.结果表明,AA、DA和UA在CA/GC电极上氧化峰电流增大,且三者氧化峰电位明显分离(ΔEp(DA,AA)=170 mV,ΔEp(DA,UA)=130 mV,ΔEp(AA,UA)=300 mV).据此,可同时检测AA、DA和UA.在优化的实验条件下,AA、DA和UA的氧化峰电流与其浓度分别在2.0×10-6~1.5×10-3mol.L-1,6.0×10-7~1.0×10-3mol.L-1和6.0×10-7~1.0×10-3mol.L-1范围内呈线性关系.该电极重现性好,可用于盐酸多巴胺针剂DA、VC片剂AA及人体尿液UA的测定.  相似文献   

20.
In this paper, a pre‐anodized carbon paste electrode (PACPE) is fabricated by a simple electrochemical pretreatment method, which can be used for the simultaneous determination of uric acid (UA) and ascorbic acid (AA). The influencing mechanism of the acidity on the size of oxidation peak current (ip,a) of UA and AA is discussed in detail. According to the results, in different pH conditions, the intensity of hydrogen bonding between UA, AA and the surface of PACPE, the degree of reduction reaction at the auxiliary electrode, and the structural configurations of UA and AA with different species in reaction system have evident influence on the size of oxidation peak current. In pH 7.00 phosphate buffer solution, the calibration curves for UA and AA are obtained in the range of 5.0 x 10‐7–5.0 x 10‐5 mol/L and 3.0 x 10‐5–5.0 x 10‐3 mol/L, respectively. The detection limits for UA and AA are found to be 2.0 x 10‐8 mol/L and 1.2 x 10‐6 mol/L, respectively. This proposed method has been successfully applied to determine UA and AA in human urine simultaneously with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号