首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
An open tubular molecule imprinted polymer (OT‐MIP) capillary column has been prepared for chiral separation of ofloxacin enantiomers in CEC. The S‐ofloxacin imprinted OT column was fabricated by thermally initiated non‐covalent polymerization procedure inside a pretreated and silanized fused silica capillary. The template molecule was incorporated with methacrylic acid (MAA), ethylene glycol dimethacrylate (EDMA) and 4‐styrenesulfonic acid (4‐SSA) and dissolved in a porogen mixture of ACN/2‐propanol (9:1). The separation efficiency of the 4‐SSA MIP column was found quite better than that of the MIP column without 4‐SSA. It has been demonstrated that our OT‐MIP column can separate ofloxacin enantiomers with excellent chiral separation efficiency after tuning the various chromatographic conditions. The optimized chromatographic eluent was 85:15, v/v%, ACN/60 mM sodium acetate at pH 7. The separation efficiency and selectivity of chiral separation of this study were far better than those obtained by previous methods for chiral separation of R‐ and S‐ofloxacin.  相似文献   

2.
A procedure is described for the slurry packing of 50‐μm ID fused silica capillaries with 3‐μm octadecyl silica (ODS) particles for capillary electrochromatography (CEC) and its hyphenation with electrospray ionisation mass spectrometry (ESI/MS). A homogeneous packed bed is obtained by using a slow packing process in an upward direction with a balanced density slurry solvent and MeOH as packing solvent. Special attention was paid to the in‐ and outlet frit preparation in order to avoid gas bubble formation which renders CEC‐ESI/MS problematic. Frits were made out of the packed bed itself, sintered in water, by using a perforated heating ribbon; they were not longer than 1 mm. In CEC‐UV, column efficiencies up to 300,000 plates per meter were obtained. Absence of gas bubbles was ascertained by the straightforward coupling to ESI/MS. A make‐up flow of 3 μL/min H2O/MeOH containing 0.1% HCOOH was used in the sheath flow interface. Steroids and carbamates were analysed with a 0.1% triethylamine‐acetic acid buffer (pH 8.9) containing varying amounts of acetonitrile. In CE‐ESI/MS, efficiencies dropped by ca. 20% but spectral data were excellent.  相似文献   

3.
A pressure‐assisted CEC with ESI‐MS based on poly(1‐hexadecene‐co‐trimethylolpropane trimethacrylate) monolithic column for rapid analysis of two β2‐agonists and three narcotics was established in this article. After the organic polymer‐based monolithic column was prepared by an in‐situ polymerization procedure, a systematic investigation of the pressure‐assisted CEC separation and ESI‐MS detection parameters was performed. Baseline separation of the studied analytes could be obtained using the solution containing 75% ACN v/v and 20 mmol/L ammonium acetate with pH 8.0 as running buffer, when applying separation voltage of 20 kV and assisted pressure of 5 bar. Under the optimized conditions, two β2‐agonists and three narcotics could be completely resolved and accurately determined within 15 min. Finally, the proposed method was successfully used for real urine samples detection.  相似文献   

4.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

5.
Shabi Abbas Zaidi 《Electrophoresis》2013,34(9-10):1375-1382
To extend the application of molecularly imprinted polymers, the dual‐templates molecularly imprinted monolithic columns were developed in a capillary format. Two templates serotonin and histamine were simultaneously imprinted using two different functional monomers such as methacrylic acid (MAA) and methylenesuccinic acid (MSA) in a mixture of ethylene glycol dimethacrylate (EDMA) as a cross‐linker and AIBN as polymerization initiator dissolved in DMF as porogen. The resulting molecular imprinted polymers (MIPs) were characterized based on their performance in the CEC separation of two imprinted templates. The optimization parameters such as pH, ACN composition, and concentration of the eluent were varied to achieve best resolution and efficiency for CEC separation of templates with each MIP column. It was found that the MIP monolith column fabricated using MSA offered better resolution and separation efficiency compared to column fabricated with MAA. This work utilized the dual‐templates imprinting approach successfully and broadens the scope of multi‐templates imprinting capabilities in capillary format in CEC application.  相似文献   

6.
A new and simple open‐tubular CEC (OT‐CEC) method with a novel diblock copolymer poly(butyl methacrylate)71‐block‐poly(glycidyl methacrylate)9 as the coating based on its self‐assembled properties has been developed. Compared with the bare capillary, this coating could act as a surfactant and improve the separation efficiency of aromatic amines. Meanwhile, the effects of pH value, buffer concentration, and the copolymer block ratio on the separation efficiencies were investigated in detail. It has been found that the three tested aromatic amines could be baseline separated by the OT‐CEC method with the cooperation of SDS. The proposed OT‐CEC method showed good repeatability with RSDs <3.2% for testing the EOF. Moreover, it was also well validated by satisfactory linearity and favorable recovery, which ensured its successful application in the separation of aromatic amines in nail polish samples. The results revealed the potential applicability of the OT‐CEC method in cosmetic analysis.  相似文献   

7.
A new trimethylamine amination polychloromethyl styrene nanolatex (TMAPL) and TMAPL coated capillary column (ccc‐TMAPL) were successfully prepared. The TMAPL coating was characterized with reversed steady EOF values of ca. ?16.8 × 10?5 cm2 V?1 s?1. It was applied to establish open‐tubular (OT) CEC and field‐amplified sample stacking (FASS) OT‐CEC methods for the determination of bromate in tap water. Compared to OT‐CEC, the LOD with FASS‐OT‐CEC was improved from 80 to 8 ng/mL. The developed FASS‐OT‐CEC method was practically used for the analysis of bromate in tap water samples with recoveries ranging from 93.6 to 103.5%.  相似文献   

8.
A generalized preparation procedure of open tubular (OT) molecule imprinted polymer (MIP) columns is proposed for a number of templates with acidic functionality such as profen drugs and others. The template (S‐enantiomer) was mixed with methacrylic acid, ethylene glycol dimethacrylate and 4‐styrenesulfonic acid, dissolved in a porogen mixture of ACN/2‐propanol (9/1), and incubated in a pretreated and silanized fused silica capillary by the thermal non‐covalent polymerization procedure. The whole preparation procedure was exactly the same for all the MIP capillaries except for the selection of template. Nevertheless, the morphologies of the MIP layers were markedly variant depending upon the choice of template. The separation efficiency of each OT‐MIP column for chiral separation of R‐ and S‐enantiomers was examined and tuned to obtain the best separation efficiency by changing the chromatographic parameters such as eluent composition and pH. Different optimized conditions were obtained for different OT‐MIP columns. Nevertheless, a unified eluent could be used to obtain still quite satisfactory results. Non‐chiral separation of the MIP columns were also examined in the unified eluent with two sets of test mixtures, that is, a mixture of alkylbenzenes and a mixture of small polar solutes. The chiral and non‐chiral separation of this study resulted in very good separation efficiencies. This work is the very first study for the generalization of preparation of OT‐MIP columns for a number of templates.  相似文献   

9.
Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.  相似文献   

10.
《Electrophoresis》2018,39(11):1382-1389
A sheath‐flow interface is the most common ionization technique in CE‐ESI‐MS. However, this interface dilutes the analytes with the sheath liquid and decreases the sensitivity. In this study, we developed a sheathless CE‐MS interface to improve sensitivity. The interface was fabricated by making a small crack approximately 2 cm from the end of a capillary column fixed on a plastic plate, and then covering the crack with a dialysis membrane to prevent metabolite loss during separation. A voltage for CE separation was applied between the capillary inlet and the buffer reservoir. Under optimum conditions, 52 cationic metabolite standards were separated and selectively detected using MS. With a pressure injection of 5 kPa for 15 s (ca. 1.4 nL), the detection limits for the tested compounds were between 0.06 and 1.7 μmol/L (S/N = 3). The method was applied to analysis of cationic metabolites extracted from a small number (12 000) of cancer cells, and the number of peaks detected was about 2.5 times higher than when using conventional sheath‐flow CE‐MS. Because the interface is easy to construct, it is cost‐effective and can be adapted to any commercially available capillaries. This method is a powerful new tool for highly sensitive CE‐MS‐based metabolomic analysis.  相似文献   

11.
We have designed a semi‐online liquid chromatography/matrix‐assisted laser desorption/ionization mass spectrometry (LC/MALDI‐MS) system to introduce eluent from a octadecylsilyl (ODS) group modified monolithic silica capillary chromatographic column directly onto a sample plate for MALDI‐MS analysis. Our novel semi‐online system is useful for rapidly and sensitively examining the performance of a monolithic capillary column. An additional advantage is the small elution volume of a monolithic capillary column, which allows delicate eluents, such as 1,1,1,3,3,3,‐hexafluoroisopropyl alcohol (HFIP), to be used to achieve cost‐effective analysis. Using the semi‐online LC/MALDI‐MS system, chromatographic separation of polymers by the monolithic column with different eluents was studied. Separation of poly(methyl methacrylate) and Nylon 6/6 showed that the column functioned via size‐exclusion separation when tetrahydrofuran or HFIP eluent was used. On the other hand, the separation behavior of Nylon 11 indicated a reversed‐phase mode owing to the interaction of the polymer with the modified ODS group in the column. Using tetrahydrofuran/methanol (1:1, v/v) as the eluent, the LC/MALDI‐MS spectra of poly(lactic acid), which contains both linear and cyclic polymer structures, showed that the column could separate the hydrophobic cyclic polymer and elute it out relatively slowly. The monolithic column functions basically via size‐exclusion separation; the reversed‐phase separation by interaction with the ODS functions may have less influence on column separation. The semi‐online monolithic capillary LC/MALDI‐MS method we have developed should provide a means of effectively analyzing synthetic polymers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
A new in-house designed and constructed injection valve for capillary electrochromatography (CEC) based on a rotating injection part with compartments for the eluent as well as for the sample has been coupled to a mass spectrometer via a sheath flow electrospray ionisation (ESI) interface, using short capillary columns of 15 cm length. The CEC columns were packed with 3 microm C(18) bonded silica particles, and a mixture of peptides was analysed using an ammonium acetate/acetonitrile eluent. A significant increase in the signal-to-noise ratio was obtained when the peptides were dissolved in water with the same content of organic modifier as in the eluent with an addition of 0.5% (v/v) acetic acid. When the CEC analysis was performed without any additional pressure, the separation current sometimes dropped tremendously due to bubble formation, caused by different permeability in the first and packed part of the column causing an extremely low electroosmotic flow. The separation current was restored to its original value by applying only 7 bar at the inlet of the CEC column, and the separation performance for the test peptides was recovered. A comparison of the CEC performance of peptides in pure CEC mode and in low-pressure CEC mode is reported.  相似文献   

13.
Zhu Y  Zhou C  Qin S  Ren Z  Zhang L  Fu H  Zhang W 《Electrophoresis》2012,33(2):340-347
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption.  相似文献   

14.
岳春月  丁国生  唐安娜 《色谱》2013,31(1):10-14
依据分子印迹技术(MIT)制备的分子印迹聚合物(MIP)颗粒对模板分子及其结构类似物具有特异性识别和选择性吸附作用,同时具有较大的比表面积和快速的传质动力学特性,因而被广泛用作液相色谱固定相和固相萃取材料。将MIP颗粒作为固定相应用于毛细管电色谱(CEC),结合了CEC的快速、高效和MIP的高亲和性、高选择性的特点,成为分析科学领域最具有发展前景的分离技术之一。MIP颗粒在CEC领域有几种不同的应用形式: 作为填充材料填充到毛细管柱中;作为嵌入材料嵌入到毛细管柱内部不同基质的骨架中;作为准固定相添加到CEC运行缓冲溶液中。本文综述了近几年MIP颗粒在CEC领域应用的发展,对该领域今后的发展前景进行了展望。  相似文献   

15.
A novel drug‐screening system, consisting of paper spray‐MS (PS‐MS) and a CE‐ESI‐MS method was developed. This system can be easily switched either to PS‐MS for rapidly screening samples or to the traditional CE‐ESI‐MS method for separation and to obtain detailed mass spectral information, while sharing the same mass spectrometer. In the former case, when a sharp (15°‐tip) chromatography paper was used, the optimized distance from the paper tip to the mass inlet was 7.7 mm, whereas the optimized distance for the CE‐ESI tip was ~13.5 mm. Using 4chloroamphetamine as a model compound, the LODs for PS‐MS and CE‐ESI‐MS were determined to ~0.1 and 0.25 ppm, respectively. Comparisons of results obtained using PS‐MS and CE‐ESI‐MS and the experimental conditions are described.  相似文献   

16.
One of the challenging instrumental aspects in coupling an automated CE instrument with ESI mass spectrometry (CE‐MS) is finding the balance between the stability, reproducibility and sensitivity of the analysis and compatibility with the standard CE instrumentation. Here, we present a development of a new liquid junction based electrospray interface for automated CE‐MS, with a focus on the technical design followed by computer modeling of transport conditions as well as characterization of basic performance of the interface. This hybrid arrangement designed as a microfabricated unit attachable to the automated CE instrument allows using of a wide range of separation capillaries with respect to their diameter, length or internal coating (e.g., for suppressed electroosmotic flow). Different compositions of the ESI liquid and background electrolyte solutions can be used if needed. The microfabricated part, prepared by laser machining from polyimide, includes a self‐aligning liquid junction, a short transport channel, and a pointed sprayer for the electrospray ionization. This microfabricated part is positioned in a plastic connection block securing the separation capillary and flushing ports. Transport conditions were modelled using computer simulation and the real life performance of the interface was compared to that of a commercial sheath liquid interface. The basic performance of the interface was demonstrated by separations of peptides, proteins, and oligosaccharides.  相似文献   

17.
In this work, a novel molecularly imprinted polymer (MIP) monolithic column with integrated in‐column electroosmotic pump (EOP) was designed and successfully prepared to facilitate the capillary chromatography with MIP column. A silica‐based EOP was synthesized at the detection end of the MIP monolithic capillary column by so‐gel to provide the hydrodynamic driven force for the capillary chromatography. Because of large surface area and low fluidic resistance of the silica monolith,a strong and steady EOF was generated by silica‐based EOP, indicating that the EOP was quite compatible with MIP capillary column. With the sufficient EOF provided by EOP, the electro‐driven based capillary chromatographic separation of nitrophenol isomers was achieved in 4‐vinylpyridine‐based MIP monolithic capillary, which was originally proved infeasible because of the EOF shortage. No significant influence upon the specific recognition of the MIP was found due to the setting of EOP after the detection window of the column. The influence of experimental parameters on the EOF such as voltage and pH value of running buffer was investigated. The column was also evaluated by capillary liquid chromatographic mode to compare with EOP‐driven capillary chromatography. Higher column efficiency was obtained by EOP‐driven separation with improved peak shape. The results suggested that EOP‐supported technique would be a good way to solve the problem of weak EOF generation in electro‐driven capillary chromatography.  相似文献   

18.
本文采用原位聚合法制备了以四肽YPLG为模板的毛细管分子印迹整体柱,在毛细管电色谱模式下以模板分子和它的结构类似物YPGL为样品,对分子印迹聚合物的识别机理进行了研究。这两种四肽由于化学结构相似且等电点非常相近,普通的电色谱和毛细管电泳方法分离非常困难。但我们的实验表明,印迹整体柱对模板分子具有特异性识别能力,因此YPLG与YPGL之间的分离因子为1.73,分离度达3.72。实验中系统地研究了流动相中有机溶剂的含量、缓冲溶液的pH值、缓冲溶液的盐浓度以及柱温对四肽识别的影响。实验中我们观察到模板在印迹柱上具有非线性的Van’t Hoff行为,揭示可能存在多重保留机理。本研究结果表明,在毛细管电色谱模式下,分子印迹整体柱的分子识别主要决定于样品与印迹聚合物之间的氢键作用以及印迹孔穴的三维结构。  相似文献   

19.
Amino acids residues are commonly submitted to various physicochemical modifications occurring at physiological pH and temperature. Post‐translational modifications (PTMs) require comprehensive characterization because of their major influence on protein structure and involvement in numerous in vivo process or signaling. Mass spectrometry (MS) has gradually become an analytical tool of choice to characterize PTMs; however, some modifications are still challenging because of sample faint modification levels or difficulty to separate an intact peptide from modified counterparts before their transfer to the ionization source. Here, we report the implementation of capillary zone electrophoresis coupled to electrospray ionization tandem mass spectrometry (CZE‐ESI‐MS/MS) by the intermediate of a sheathless interfacing for independent and highly sensitive characterization of asparagine deamidation (deaN) and aspartic acid isomerization (isoD). CZE selectivity regarding deaN and isoD was studied extensively using different sets of synthetic peptides based on actual tryptic peptides. Results demonstrated CZE ability to separate the unmodified peptide from modified homologous exhibiting deaN, isoD or both independently with a resolution systematically superior to 1.29. Developed CZE‐ESI‐MS/MS method was applied for the characterization of monoclonal antibodies and complex protein mixture. Conserved CZE selectivity could be demonstrated even for complex samples, and foremost results obtained showed that CZE selectivity is similar regardless of the composition of the peptide. Separation of modified peptides prior to the MS analysis allowed to characterize and estimate modification levels of the sample independently for deaN and isoD even for peptides affected by both modifications and, as a consequence, enables to distinguish the formation of l ‐aspartic acid or d ‐aspartic acid generated from deaN. Separation based on peptide modification allowed, as supported by the ESI efficiency provided by CZE‐ESI‐MS/MS properties, and enabled to characterize and estimate studied PTMs with an unprecedented sensitivity and proved the relevance of implementing an electrophoretic driven separation for MS‐based peptide analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
Tryptophan (TRP) is an essential amino acid catabolized mainly through the kynurenine pathway, and part of it is catabolized in the brain. The abnormal depletion of TRP and production of kynurenine (KYN) by two enzymes, tryptophan 2,3-dioxygenase (TDO) and indoleamine 2,3-dioxygenase (IDO), have been linked to various neurological diseases. The ratio of TRP/KYN in plasma is a valuable measure for IDO/TDO activity and the prognosis of disease conditions. The 4-vinylphenylboronic acid (4-VPBA) was evaluated as a novel stationary phase for OT–CEC–MS/MS. TRP, KYN, and 3-hydroxykynurenine were separated using optimum conditions of 15 mM (NH4)2CO3 at pH 8 as a background electrolyte and 25 kV separation voltage on a 90 cm column. The usefulness of the 4-VPBA column for simple, fast, repeatable, and sensitive CEC–ESI–MS/MS application was demonstrated for the quantitation of TRP and KYN in the plasma of healthy human subjects and neuroinflammation subjects. The plasma sample was extracted on a zirconia-based ion-exchange cartridge for simultaneous protein precipitation and phospholipid removal. The method of standard addition, in combination with the internal standards approach, was used to prepare the calibration curve to overcome matrix matching and eliminate procedural errors. The developed quantitation method was validated according to FDA guidelines for sensitivity, accuracy, precision, and extraction recovery. The measured plasma level of TRP and KYN in healthy humans is aligned with the human metabolome database for the same two metabolites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号