首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A signal‐enhanced immunosensor has been developed by self‐assembling Au NPs onto a ferrocene‐branched poly(allylamine)/multiwalled carbon nanotubes (PAA‐Fc/MWNTs) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg) as a model protein. The formation of PAA‐Fc/MWNTs composite not only effectively avoided the leakage of Fc and retained its electrochemical activity, but also enhanced the conductivity and charge‐transport properties of the composite. Further adsorption of Au NPs into the PAA matrix provided both the interactive sites for the immobilization of hepatitis B surface antibody (HBsAb) and a favorable microenvironment to maintain its activity. Tests performed with this immunosensor showed a specific response to HBsAg in the range of 0.1–350.0 ng mL?1 with a detection limit of 0.03 ng mL?1.  相似文献   

2.
In this article, a detailed electrochemical study of a novel 6‐ferrocenylhexanethiol (HS(CH2)6Fc) self‐assembled multiwalled carbon nanotubes‐Au nanoparticles (MWNTs/Au NPs) composite film was demonstrated. MWNTs/Au NPs were prepared by one‐step in situ synthesis using linear polyethyleneimine (PEI) as bifunctionalizing agent. HS(CH2)6Fc, which acted as the redox mediator, was self‐assembled to MWNTs/Au NPs via Au‐S bond. Transmission electron microscopy (TEM), energy‐dispersive X‐ray analysis (EDX), Fourier transformed infrared absorption spectroscopy (FT‐IR), UV‐visible absorption spectroscopy, and cyclic voltammetry were used to characterize the properties of the MWNTs/Au NPs/HS(CH2)6Fc nanocomposite. The preparation of the nanocomposite was very simple and effectively prevented the leakage of the HS(CH2)6Fc mediator during measurements. The electrooxidation of AA could be catalyzed by Fc/Fc+ couple as a mediator and had a higher electrochemical response due to the unique performance of MWNTs/Au NPs. The nanocomposite modified electrode exhibited excellent catalytic efficiency, high sensitivity, good stability, fast response (within 3 s) and low detection limit toward the oxidation of AA at a lower potential.  相似文献   

3.
《Electroanalysis》2018,30(3):402-414
A sensitive electrochemical immunosensor for Hepatitis B virus surface antigen (HBsAg) detection was fabricated based on hemin/G‐quadruplex interlaced onto Fe3O4‐AuNPs or hemin ‐amino‐reduced graphene oxide nanocomposite (H‐amino‐rGO‐Au). G‐quadruplex DNAzyme, which is composed of hemin and guanine‐rich nucleic acid, is an effective signal amplified tool for its outstanding peroxidase activity and Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites with quasi‐enzyme activity provide appropriate support for the immobilization of hemin/G‐quadruplex. The target protein was sandwiched between the primary antibody immobilized on the GO and secondary antibody immobilized on the Fe3O4‐AuNPs or (H‐amino‐rGO‐Au) nanocomposites and glutaraldehyde was used as linking agent for the immobilization of primary antibody on the surface of GO. Both Fe3O4‐AuNPs and H‐amino‐rGO‐Au nanocomposite and also hemin/G‐quadruplex can cooperate the electrocatalytic reduction of H2O2 in the presence of methylene blue as mediator. The proposed immunosensor has a wide linear dynamic range of 0.1 pg/ml to 300 pg/ml with a detection limit of 60 fg/ml when Fe3O4‐AuNPs was used for immobilization of hemin/G‐quadruplex, while the dynamic range and DL were 0. 1–1000 pg/mL and 10 fg/mL, respectively in the presence of H‐amino‐rGO‐ Au nanocomposite as platform for immobilizing of hemin/G‐quadruplex. The proposed immunosensor was also used for analysis of HBsAg in spiked human serum samples with satisfactory results.  相似文献   

4.
A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold‐nanoparticles over graphene screen‐printed electrode (SPE). The antibody was covalently bound to CS via its Fc‐terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG‐immunosensor displayed linear response against the logarithm‐hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low‐cost, high sensitivity and selectivity.  相似文献   

5.
Based on the immobilization of horseradish peroxidase (HRP) in chitosan(CS) on a glassy carbon electrode (GCE) modified with the Au‐Pt alloy nanoparticles (NPs) / polyaniline nanotube (nanoPAN) nanocomposite film, a novel hydrogen peroxide biosensor was constructed. The modified processes of GCE were monitored by cyclic voltammetry and electrochemical impedance spectroscopy. Au‐PtNPs/nanoPAN/CS had a better synergistic electrochemical effect than did AuNPs/nanoPAN/CS or PtNPs/nanoPAN/CS. The amperometric response of the biosensor towards H2O2 was investigated by successively adding aliquots of H2O2 to a continuous stirring phosphate buffer solution under the optimized conditions. Because Au‐PtNPs have unique catalytic properties and good biocompatibility, and especially Au‐PtNPs and nanoPAN have synergistic augmentation for facilitating electron‐transfer, the biosensor displayed a fast response time (<2 s) and broad linear response to H2O2 in the range from 1.0 to 2200 μmol L?1 with a relatively low detection limit of 0.5 μmol L?1 at 3 times the background noise. Moreover, the biosensor can be applied in practical analysis and exhibited high sensitivity, good reproducibility, and long‐term stability.  相似文献   

6.
An amperometric immunosensor has been developed for sensitive determination of hepatitis B surface antigen as a model protein. A glassy carbon electrode was modified with an assembly of positively charged poly(allylamine)-branched ferrocene (PAA-Fc) and negatively charged gold nanoparticles (Au NPs). The formation of PAA-Fc effectively avoids the leakage of Fc, retains its electrochemical activity, and enhances the conductivity of the composite. The adsorption of Au NPs onto the PAA-Fc matrix provides sites for the immobilization of the antigen and a favorable micro-environment to maintain its activity. The morphologies and electrochemistry of the sensing film were investigated via scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. Factors influencing the performance of the immunosensor were studied in detail. The concentration of the antigen can be quantitated (by measuring the decrease of the amperometric response resulting from the specific binding between antigen and antibody) in the range between 0.1 and 150?ng?mL?C1, with a detection limit of 40?pg?mL?C1 (S/N = 3). The method is economical, efficient, and potentially attractive for clinical immunoassays.
Figure
A novel and sensitive amperometric immunosensor based on the assembly of biocompatible positively charged poly(allylamine)-branched ferrocene and negatively charged Au nanoparticles onto a glassy carbon electrode has been developed for sensitive determination of hepatitis B surface antigen as a model protein.  相似文献   

7.
This paper describes a highly sensitive and label‐free electrochemical immunosensor for the detection of 1‐pyrenebutyric acid (PBA) which is based on a graphene (GS), chitosan (CS), and ionic liquid (IL) composite modified glassy carbon electrode (GS‐CS‐IL/GCE). The modification process was monitored by transmission electron microscopy (TEM) and cyclic voltammetry (CV). Due to the synergistic effects of GS, CS, and IL, the biosensor exhibits excellent selectivity to PBA. The current response of the proposed immunosensor decreases linearly at two concentration ranges from 0.01 to 5 and from 5 to 150 ng mL?1 with a detection limit of 0.01 ng mL?1.  相似文献   

8.
《Electroanalysis》2018,30(9):2160-2166
The present study focuses on designing and fabricating an electrochemical aptasensor for the label free detection of bisphenol A (BPA) using gold nanoparticles (Au NPs) immobilized on functional cupper magnetic nanoparticles (CuFe2O4‐SH) and multiwall carbon nanotubes (MWCNTs) modified with aptamer and 6‐mercapto‐1‐hexanol (MCH). A number of analysis techniques were used to characterize the nanocomposite, including Fourier transform infrared spectroscopy, field emission scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometer, elemental mapping analysis and energy dispersive x‐ray diffraction. The results of the analyses revealed that the fabricated aptasensor had an acceptable linearity index (0.05‐9 nM) with an ultralow detection limit (25.2 pM) when used to determine BPA. Electrochemical experiments were conducted using a [Fe(CN)6]3−/[Fe(CN)6]4− redox system. The results of the electrochemical tests indicated that the existence of Au NPs along with magnetic nanoparticles and MWCNTs in nanocomposite led to a synergistic augmentation on the surface of the modified electrode, thus facilitating the efficient sensing of BPA. This method is highly selective, sensitive and environmentally friendly. Moreover, proposed aptasensor has valuable potential applications in medical diagnostics and food industries where a fast and reliable detection of BPA is of paramount importance for the health of the public.  相似文献   

9.
本文研制了一种用金胶壳聚糖仿生膜来同时固定四甲基联苯胺(TMB)和酶标抗体的新型电化学免疫传感器,用于检测血清肿瘤标志物前列腺特异性抗原(PSA)的含量。固定的TMB作为电子传递媒介体,在扫速小于45 mV/s时,电极表现为一个表面控制过程,而在扫速大于45 mV/s时则表现为一个扩散控制过程。将固定有酶标抗体和TMB的免疫传感器与待测PSA抗原一起培育,在该传感器上形成的免疫复合物通过TMB-H2O2-HRP电化学体系进行了测定。在优化实验条件下,PSA的线性检测范围为5-30 ng·mL-1,检测限为1.0 ng·mL-1。该PSA免疫传感器制备方法简单,成本低廉,具有较好的稳定性和重现性。  相似文献   

10.
A uric acid (UA) electrochemical biosensor based on the Cu‐Au alloy nanoparticles (NPs) and uricase was developed. The electrodeposition technique of Cu‐Au alloy NPs was selected to be a convenient potentiostatic method at –0.8 V in a single solution containing both Au(III) and Cu2+. Cyclic voltammetry and scanning electron microscopy proved the successful deposition of Cu‐Au alloy NPs. EIS demonstrated the good conductivity of Cu‐Au alloy NPs. The enzyme was immobilized on the surface of Cu‐Au alloy NPs modified electrode by casting with chitosan solution. The ultimate biosensor showed linear amperometric response towards UA in the concentration range of 3.0 to 26.0 μM with a detection limit of 0.8 μM. The main feature of the biosensor was its short response time, which was attributed to the good conductivity of Cu‐Au alloy NPs. Furthermore, the biosensor could avoid the interference of ascorbic acid and oxygen.  相似文献   

11.
This paper reports the fabrication of Au nanoparticles (Au NPs)‐Ni‐Al layerd double hydroxide (LDH) composite film by one step electrochemical deposition on the surface of a glass carbon electrode from the mixture solution containing HAuCl4 and nitrate salts of Ni2+ and Al3+. Improved conductivity was obtained by Au NPs codeposited on LDH film. The synergic effect of LDHs and Au NPs dramatically improves the performance of L ‐cysteine electro‐oxidation, displaying low oxidation peak potential (0.16 V) and high current response. Thus the electrode was used to sense L ‐cysteine, showing good sensitivity and selectivity.  相似文献   

12.
A novel and highly sensitive electrochemical immunosensor was developed for the detection of protein biomarker tumor necrosis factor‐alpha (TNF‐α) based on immobilization of TNF‐α‐antibody (anti‐TNF‐α) onto robust nanocomposite containing gold nanoparticles (AuNP), multiwalled carbon nanotubes (MWCNTs) and ionic liquid (1‐buthyl‐3‐methylimidazolium bis (trifluoromethyl sulfonyl)imide). Functionalized MWCNT‐gold nanoparticle was produced by one‐step synthesis based on the direct redox reaction. The electrochemical properties of nanocomposite were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The anti‐TNF‐α was immobilized or entrapped in the nanocomposite and used in a sandwich type complex immunoassay with anti‐TNF‐α labeled with horseradish peroxidase as secondary antibody. Under optimum conditions, the immunosensor could detect TNF‐α in a linear range from 6.0 to 100 pg mL?1 with a low detection limit of 2.0 pg mL?1. The simple fabrication method, high sensitivity, good reproducibility, stability, as well as acceptable accuracy for TNF‐α detection in human serum samples are the main advantages of this immunosensor, which might have broad applications in protein diagnostics and bioassay.  相似文献   

13.
The ability to capture, store, and use CO2 is important for remediating greenhouse‐gas emissions and combatting global warming. Herein, Au nanoparticles (Au‐NPs) are synthesized for effective electrochemical CO2 reduction and syngas production, using polyethylenimine (PEI) as a ligand molecule. The PEI‐assisted synthesis provides uniformly sized 3‐nm Au NPs, whereas larger irregularly shaped NPs are formed in the absence of PEI in the synthesis solution. The Au‐NPs synthesized with PEI (PEI?Au/C, average PEI Mw=2000) exhibit improved CO2 reduction activities compared to Au‐NPs formed in the absence of PEI (bare Au NPs/C). PEI?Au/C displays a 34 % higher activity toward CO2 reduction than bare Au NPs/C; for example, PEI?Au/C exhibits a CO partial current density (jCO) of 28.6 mA cm?2 at ?1.13 VRHE, while the value for bare Au NPs/C is 21.7 mA cm?2; the enhanced jCO is mainly due to the larger surface area of PEI?Au/C. Furthermore, the PEI?Au/C electrode exhibits stable performance over 64 h, with an hourly current degradation rate of 0.25 %. The developed PEI?Au/C is employed in a CO2‐reduction device coupled with an IrO2 water‐oxidation catalyst and a proton‐conducting perfluorinated membrane to form a PEI?Au/C|Nafion|IrO2 membrane‐electrode assembly. The device using PEI?Au/C as the CO2‐reduction catalyst exhibits a jCO of 4.47 mA/cm2 at 2.0 Vcell. Importantly, the resulted PEI?Au/C is appropriate for efficient syngas production with a CO ratio of around 30–50 %.  相似文献   

14.
A silver nanocomposite was one‐step synthesized in chitosan solution and used to prepare an immunosensor with the aid of gold nanoparticles (Au NPs) assembly. The Ag NPs at the immunosensor exhibited sensitive electrochemical stripping signal in KCl solution. After a sandwich immunoreaction, the current response of the immunosensor decreased due to the formation of antibody‐antigen immunocomplex on its surface, which was greatly amplified by the captured silica nanoprobes and thus enabled an ultrasensitive electrochemical immunoassay method. This method showed excellent analytical performance for human IgG measurement including wide linear range, low detection limit, cheap cost, satisfactory reproducibility and stability.  相似文献   

15.
In this work, a glassy carbon electrode (GCE) was modified with multiwall carbon nanotubes/ionic liquid/graphene quantum dots (MWCNTs/IL/GQDs) nanocomposite. Then, the nanocomposite was decorated with nickel‐cobalt nanoparticles (Ni?Co NPs), and it was used as a non‐enzymatic glucose sensor. Field emission scanning electron microscopy, X‐ray diffraction spectroscopy, and energy dispersive spectroscopy were employed to prove the electrodeposition of the Ni?Co NPs on the surface of MWCNTs/IL/GQDs/GCE. Also, cyclic voltammetric and amperometric methods were utilized for the investigation of the electrochemical behaviour of the Ni?Co NPs/MWCNTs/IL/GQDs/GCE for glucose oxidation. The novel amperometric sensor displayed two linear ranges from 1.0 to 190.0 μmol L?1 and 190.0 to 4910 μmol L?1 with a low detection limit of 0.3 μmol L?1 as well as fast response time (2 s) and high stability. Also, the sensor showed good selectivity for glucose determination in the presence of ascorbic acid, citric acid, dopamine, uric acid, fructose, and sucrose, as potential interference species. Finally, the performance of the proposed sensor was investigated for the glucose determination in real samples. Ni?Co NPs/MWCNTs/IL/GQDs/GCE showed good sensitivity and excellent selectivity.  相似文献   

16.
In the present work, a newly functional nanoparticle has been prepared to immobilize the protein for the detection of α‐1‐fetoprotein (AFP). Prussian blue (PB) nanoparticle was initially synthesized under ultrasonic condition, then bovine serum albumin (BSA) was used to coat the PB nanoparticle to improve the stability of the PB nanoparticle as well as functionalize the surface of PB nanoparticle, and then gold colloids were loaded on the BSA‐coated PB nanoparticle to construct a core‐shell‐shell nanostructure via the conjunction of thiolate linkages or alkylamines of the BSA. Finally, a convenient, effective and sensitivity amperometric immunosensor for the detection of α‐1‐fetoprotein (AFP) was constructed by the employment of these functional core‐shell‐shell microspheres. The preparation of the nanoparticle (Au‐BSA‐PB NPs) was characterized by transmission electron microscopy (TEM), and the assembly of the biosensor was characterized with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The dynamic range of the resulted immunosensor for the detection of AFP is from 0.02 ng/mL to 200.0 ng/mL with a detection limit of 0.006 ng/mL (S/N=3). Moreover, this biosensor displays good selectivity, stability and reproducibility.  相似文献   

17.
In this work, the electrochemical behavior of ferrocene (Fc) was investigated by cyclic voltammetry (CV) in room temperature ionic liquids (RTILs) of 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIBF4) on glass carbon (GC), edge plane pyrolytic graphite (EPPG) and multi‐walled carbon nanotube (MWCNTs)‐modified EPPG electrodes, respectively. The results demonstrated that on GC electrode, pairs of well‐defined reversible peaks were observed, while for the electrode of EPPG, the peak potential separation (ΔEp) is obviously larger than the theoretical value of 59 mV, hinting that the electrode of EPPG is distinguished from the commonly used electrode, consistent with the previous proposition that EPPG has many “defects”. To obtain an improved electrochemical response, multi‐walled carbon nanotubes (MWCNTs) were modified on the electrode of EPPG; the increased peak current and promoted peak potential separation not only proved the existence of “defects” in MWCNTs, but also supported that “creating active points” on an electrode is the main contribution of MWCNTs. Initiating the electrochemical research of Fc on the MWCNTs‐modified EPPG electrode in RTILs and verifying the presence of “defects” on both EPPG and MWCNTs using cyclic voltammograms (CVs) of Fc obtained in RTILs of EMIBF4, is the main contribution of this preliminary work.  相似文献   

18.
Three‐dimensional nanostructured metallic substrates for enhanced vibrational spectroscopy are fabricated by self‐assembly. Nanostructures consisting of one to 20 depositions of 13 nm‐diameter Au nanoparticles (NPs) on Au films are prepared and characterized by means of AFM and UV/Vis reflection–absorption spectroscopy. Surface‐enhanced polarization modulation infrared reflection–absorption spectroscopy (PM‐IRRAS) is observed from Au NPs modified by the probe molecule 4‐hydroxythiophenol. The limitation of this kind of substrate for surface‐enhanced PM‐IRRAS is discussed. The surface‐enhanced Raman scattering (SERS) from the same probe molecule is also observed and the effect of the number of Au‐NP depositions on the SERS efficiency is studied. The SERS signal from the probe molecule maximizes after 11 Au‐NP depositions, and the absolute SERS intensities from different batches are reproducible within 20 %. In situ electrochemical SERS measurements show that these substrates are stable within the potential window between ?800 and +200 mV (vs. Ag/AgCl/sat. Cl?).  相似文献   

19.
《Electroanalysis》2018,30(2):353-360
A label‐free electrochemical immunosensor based on the liquid crystal (E)‐1‐decyl‐4‐[(4‐decyloxyphenyl)diazenyl]pyridinium bromide (Br−Py), together with heparin‐stabilized gold nanoparticles (AuNP‐Hep) and Nafion is proposed for the determination of prostate‐specific antigen (PSA). The Br−Py liquid crystal presented redox properties and good film‐forming abilities on the electrode surface, and thus it is a suitable alternative as a redox probe for a label‐free electrochemical immunosensor, which could simplify the analysis methodology. The stepwise construction of the immunosensor and the incubation process (immunocomplex formation) were characterized by voltammetry and electrochemical impedance spectroscopy. The proposed immunosensor could directly detect PSA concentrations in the incubation samples, based on the suppression of the Br−Py redox peak (‘base peak’) current. After optimization, the immunosensor exhibited a linear response to PSA concentrations in the range of 0.1 to 50 ng mL−1, with a calculated detection limit of 0.08 ng mL−1. The reproducibility (coefficient of variance less than 3.0 %), selectivity and accuracy of the methodology were adequate. The immunosensor was satisfactorily applied in the quantification of PSA in human blood plasma samples.  相似文献   

20.
A signal‐enhanced label‐free electrochemical immunosensor was constructed by the employment of Prussian blue doped silica dioxide (PB‐SiO2) nanocomposite. At first, PB‐SiO2 nanocomposite which was produced by using a microemulsion method was used to obtain a nanostructural monolayer on a glassy carbon electrode (GCE) surface. Next amino‐functionalized interface were prepared by self‐assembling 3‐aminopropyltriethoxy silane (APTES) on the PB‐SiO2 nanoparticle surface. Then chitosan stabled gold nanoparticle (CS‐nanoAu) was subsequently attached, while the entire surface was finally loaded with neuron‐specific enolase antibody (anti‐NSE) via the adsorption of gold nanoparticle. The sensitivity of the proposed immunosensor has greatly improved as the PB‐SiO2 nanostructural sensing film provides plenty of active sites which might catalyze the reduction of H2O2. The immunosensor exhibited good linear behavior in the concentration range from 0.25–5.0 and 5.0–75 ng/mL for the quantitative analysis of neuron‐specific enolase (NSE), a putative serum marker of small‐cell lung carcinoma (SCLC), with a limit of detection of 0.08 ng/mL. The resulting NSE immunosensor showed high sensitivity and long‐term lifetime which can be attributed to the extremely high catalytic activity and biocompatibility of CS‐nanoAu/APTES/PB‐SiO2 nanostructural multilayers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号