首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 44 毫秒
1.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff.
Graphical abstract Compared with graphene, carbon nanotubes and carbon nanofibers, an electrode modified with fullerene in chitosan electrode displays superior performance for the simultaneous anodic stripping voltammetric detection of Hg(II), Cu(II), Pb(II) and Cd(II).
  相似文献   

2.
Shoupu L  Mingqiao Z  Chuanyue D 《Talanta》1994,41(2):279-282
A reversed-phase high-performance liquid chromatographic separation and determination of beryllium(II), aluminium(III) and chromium(III) with chromotrope 2C chelates on a C18-bonded stationary phase is reported. Methanol-water (45:55 v/v) containing 6 x 10(-3)M tetra-n-butylammonium bromide (TBAB) and 2 x 10(-2)M acetate buffer solution (pH 6.0) as mobile phase and with spectrophotometric detection at 530 nm was applied. The method has high sensitivity, the detection limits being 0.2 ppb for beryllium(I), 1 ppb for aluminium(III) and 2 ppb for chromium(III). Under the optimum conditions, most other metal ions did not interfere, e.g. up to 2 mg of Hg(II), Sn(II, IV), Pb(II), Bi(III), Ag(I), Zn(II), Cd(II), Cu(II), 1.5 mg of Fe(II), Co(II), Ni(II), 1.2 mg of Ca(II), Mg(II), Sr(II), Ba(II), 1 mg of Ga(III), In(III), 0.5 mg of Fe(III), 1 mg of Ga(III), In(III), 0.5 mg of Fe(III), 0.4 mg of Th(IV), Zr(IV). The method can be applied to the simultaneous determination of trace amounts of beryllium(II), aluminium(III) and chromium(III), in water, rice, flour and human hair samples.  相似文献   

3.
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.  相似文献   

4.
The authors report on a disposable sensor for the differential pulse anodic stripping voltammetric (DPASV) determination of the ions Zn(II), Pb(II) and Cu(II). Simultaneous detection is accomplished by using a screen-printed carbon electrode (SPCE) co-modified with an in-situ plated bismuth (Bi)) film and gold nanoparticles (AuNPs). The synergistic effect of the Bi film, and the large surface and good electrical conductivity of the AuNPs strongly assist in the co-deposition of the three ions. Four well-defined and fully separated anodic stripping peaks, at 540 mV for Zn(II), 50 mV for Pb(II), 140 mV for Bi(III) and 295 mV for Cu(II), all vs. Ag/AgCl, can be seen. The modified SPCE was characterized by scanning electron microscopy, X-ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the sensor has a good response to these ions. The detection limits (at an S/N ratio of 3) are 50 ng·L?1 for Zn(II), 20 ng·L?1 for Pb(II), and 30 ng·L?1 for Cu(II). The method was applied to the determination of the 3 ions in spiked lake water samples.
Graphical abstract Schematic of screen-printed carbon electrode (SPCE) co-modified with a bismuth film and gold nanoparticles for electrochemical simultaneous determination of Zn(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetric (DPASV).
  相似文献   

5.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

6.
《Analytical letters》2012,45(7):1267-1278
Abstract

In this work, a new method for the simultaneous determination of Pb(II) and Cd(II) on the multiwalled carbon nanotubes (MWNT)-Nafion-bismuth modified glassy carbon electrode (GCE) using square-wave anodic stripping voltammetry has been studied. Scanning electron microscopy was used to investigate the characteristics of the MWNT-Nafion-bismuth modified GCE. Well-defined sharp stripping peaks were observed in the determination of Pb(II) and Cd(II) simultaneously on this electrode. Under optimized conditions, the lowest detectable concentrations were 50 ng/l for Pb(II) and 80 ng/l for Cd(II) under a 10 min preconcentration. The attractive performances of MWNT-Nafion-bismuth modified GCE demonstrated its application for a simple, rapid, and harmless determination of trace heavy metals.  相似文献   

7.
A new chelating matrix has been prepared by immobilising sulfanilamide (SA) on silica gel (SG) surface modified with 3-chloropropyltrimethoxysilane as a sorbent for the solid-phase extraction (SPE) Cu(II), Zn(II) and Ni(II). The determination of metal ions in aqueous solutions was carried out by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective sorption of trace levels of Cu(II), Zn(II) and Ni(II) were optimised with respect to different experimental parameters using the batch and column procedures. The presence of common coexisting ions does not affect the sorption capacities. The maximum sorption capacity of the sorbent at optimum conditions was found to be 34.91, 19.07 and 23.62 mg g?1 for Cu(II), Zn(II) and Ni(II), respectively. The detection limit of the method defined by IUPAC was found to be 1.60, 0.50 and 0.61 µg L?1 for Cu(II), Zn(II) and Ni(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 4.0% (n = 8). The method was applied to the recovery of Cu(II), Zn(II) and Ni(II) from the certified reference material (GBW 08301, river sediment) and to the simultaneous determination of these cations in different water samples with satisfactory results.  相似文献   

8.
《Analytical letters》2012,45(9):1379-1398
Abstract

A FIA assembly producing a carrier with pH which can be adjusted to the desired pH value is propposed. It is based on the merging of two different solutions, one of them at constant flow-rate and the other at variable flow-rate. This manifold has been used for the simultaneous determination of Bi(III) and Pb(II) with Arsenazo III. Calibration curves are linear in the 1.0-11.0 ppm Bi (III) range at pH 0.25 and 1.0-12.1 ppm Pb (II) at pH 2.15. The effect of foreign ions is also reported.  相似文献   

9.
《Electroanalysis》2017,29(3):880-889
A new method for modifying electrodes with Ag nanoparticles (AgNPs) using electrospray deposition for sensitive, selective detection of Zn(II), Cd(II), and Pb(II) in aerosol samples when combined with Bismuth and Nafion coating and square‐wave anodic stripping voltammetry (SWASV) is reported. Carbon stencil‐printed electrodes (CSPEs) fabricated on a polyethylene transparency (PET) sheet were produced for an inexpensive, simple to fabricate, disposable sensor that can be used with the microliter sample volumes for analysis. Sensor performance was improved by modifying the electrode surface with electrospray‐deposited AgNPs. The use of electrospray deposition resulted in more uniform particle dispersion across the electrode surface when compared to drop‐casting. Using AgNP‐modified electrodes combined with Bi and Nafion, experimental detection limits (LODs) of 5.0, 0.5, and 0.1 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively, were achieved. The linear working ranges were 5.0–400.0 μg L−1, 0.5–400.0 μg L−1, and 0.1–500.0 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively. Interference studies showed Cu(II) was the only metal that interfered with this assay but inference could be eliminated with the addition of ferricyanide directly to the sample solution. This electrochemical sensor was applied for the simultaneous determination of Zn(II), Cd(II), and Pb(II) within source particulate matter (PM) samples collected on filters using an aerosol test chamber.  相似文献   

10.
Bismuth film modified and chemically activated carbon micro‐thread electrodes were investigated for the simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry. The carbon thread electrode was characterised using both surface and electrochemical techniques. Electrochemical impedance spectroscopy (EIS) studies demonstrated that the H2SO4/IPA‐treated carbon thread electrode showed a much improved resistance response (Rct=23 Ω) compared to the IPA‐untreated carbon thread (Rct=8317 Ω). Furthermore, parameters such as the effect of deposition potential, deposition time and Bi(III) concentration were explored using square wave voltammetry. Detection limits (S/N=3) for Cd(II) and Pb(II) were found to be 1.08 µg L?1 and 0.87 µg L?1, respectively and response was found to be linear over the range 5–110 µg L?1. The proposed Bi/IPA‐treated carbon thread electrode exhibited a high selectivity towards Cd(II) and Pb(II) even in the presence of a range of heavy metals and is capable of repetitive and reproducible measurements, being attributed to the high surface area, geometry and electrode treatment characteristics. The proposed metal ion sensor was employed to determine cadmium and lead in river water samples and % RSD was found to be 5.46 % and 5.93 % for Cd(II) and Pb(II) respectively (n=3). Such facile sensing components favour the development of cost effective portable devices for environmental sample analysis and electrochemical applications.  相似文献   

11.
Differential pulse anodic stripping voltammetry with a hanging mercury drop electrode is used for the direct and simultaneous determination of Zn, Cd, Pb, Cu, Sb and Bi at their natural levels in sea water after adjustment to pH 1 and to a 2 M chloride concentration. The optimal instrumental parameters are described. With a plating time of 60 min, the detection limits are about 0.1 ppb for Zn and Cu, 0.01 ppb for Cd and Pb, and 0.05 ppb for Sb and Bi. Relative standard deviations are about 10—15%. Simultaneous determinations of the six metals take about 2 h.  相似文献   

12.
Silica gel was firstly functionalized with aminopropyltrimethoxysilane obtaining the aminopropylsilica gel (APSG). The APSG was reacted subsequently with curcumin yielding curcumin-bonded silica gel (curcumin-APSG). This new bonded silica gel was used for separation, pre-concentration and determination of Cu(II), Fe(III), Zn(II) in biological and natural water samples by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective adsorption of trace levels of metal ions were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the newly sorbent was 4.0. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 2.0 mL of 0.1 mol L− 1 of HCl. Common coexisting ions did not interfere with the separation and determination at pH 4.0. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 0.63, 0.46 and 0.37 mmol g− 1 for Cu(II), Fe(III) and Zn(II) respectively. The time for 95% sorption for Cu(II) Fe(III) and Zn(II) was less than 2 min. The detection limits of the method defined by IUPAC was found to be 0.12, 0.15 and 0.40 ng mL− 1 for Cu(II), Fe(III) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was lower 3.0% (n = 5). The procedure was validated by analyzing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and pre-concentration of trace Cu(II), Fe(III) and Zn(II) from the biological and natural water samples yielding 75-fold concentration factor.  相似文献   

13.
A novel method has been developed for the solvent extraction of tin(IV) from 8 M hydrochloric acid with 4% N‐n‐octylaniline. Tin(IV) from the organic phase was determined spectrophotometrically with pyrocatechol violet at 550 nm. Extraction was found to be quantitative in the range of 7–10 M hydrochloric acid. When the concentration of N‐n‐octylaniline was varied from 0.05–20% in xylene, it showed that optimum concentration was > 3%. Amongst diluents like benzene and xylene, toluene was found to be an effective diluent. Effect of shaking time, concentration of metal ion, and salting out agents was studied. Tolerance limits of various diverse ions were determined by masking interfering cations. Tin(IV) was separated from associated elements in its binary mixture with Se(IV), Sb(III), Bi(III), Pb(II), Au(III), Cu(II) and Zn(II) and from its ternary mixtures with Sb(III), Bi(III) and Cu(II), Au(III). The proposed method was applied for separation and determination of tin(IV) in tin bearing alloys and foodstuffs.  相似文献   

14.
A liquid ion-exchange electrode containing a complex of mercury(II) with N-(O,O-diisopropylthiophosphoryl)thiobenzamide in carbon tetrachloride is described. The electrode shows excellent sensitivity and good selectivity. The slope of the calibration graph is 29.0 mV/pHg2+ in the pHg2+ in the pHg2+ range 2–15.2 in mercury(II) ion buffers. The electrode can be used for determination of 5 × 10?5–10?2 M Hg(II) in the presence of 10?2 M Cu(II), Ni(II), Co(II), Zn(II), Pb(II), Cd(II), Mn(II), Fe(III), Cr(III), Bi(III) or Al(III) ions and in the presence of 10?3 M Ag(I) ions. It can bealso used for end-point detection in titrations with EDTA of 10?3–10?4 M mercury(II) at pH 2.  相似文献   

15.
Goswami A  Singh AK 《Talanta》2002,58(4):669-678
A new chelating matrix has been prepared by immobilizing 1,8-dihydroxyanthraquinone (DHAQ) on silica gel modified with (3-aminopropyl)triethoxysilane. After characterizing the matrix with thermogravimetric analysis (TGA), cross polarization magic angle spinning (CPMAS) NMR and diffuse reflectance infrared fourier transformation (DRIFT) spectroscopy, it has been used to preconcentrate Pb(II), Cd(II) and Zn(II) prior to their determination by flame atomic absorption spectrometry. The optimum pH ranges for quantitative sorption are 6.0-7.5, 7.0-8.0 and 6.0-8.0 for Pb, Zn, and Cd, respectively. All the metal ions can be desorbed with 2 mol l(-1) HCl/HNO(3). The sorption capacity of the matrix has been found to be 76.0, 180.0 and 70.2 mumol g(-1) for Pb, Zn and Cd, respectively, with the preconcentration factor of approximately 200. The limits upto which electrolytes NaNO(3), NaCl, NaBr, Na(2)SO(4), Na(3)PO(4) sodium citrate, EDTA, glycine and humic acid and cations Ca(II), Mg(II), Cu(II), Co(II), Ni(II), Mn(II) Al(III), Cr(III) and Fe(III) can co-exist with the metal ions during their sorption without any adverse effect are reported. The lowest concentration of metal ions for quantitative recovery is 5.0 ng ml(-1) The simultaneous enrichment and determination of all the metals is possible if total load of metal ions is less than sorption capacity. The flame AAS was used to determine these metal ions in underground, tap and river water samples (relative standard deviation (R.S.D.)相似文献   

16.
Dalvi AA  Satpati AK  Palrecha MM 《Talanta》2008,75(5):1382-1387
Characteristics of the adsorption/electro-reduction of Pt/Rh hexamethylene tetramine (HMTA) complex on static mercury drop electrode surface were studied. Cyclic voltammetry was carried out to get the insight about the mechanistic behaviour of the catalytic current obtained in the voltammetric scan of Pt/Rh HMTA complex in acidic solution. Adsorptive stripping voltammetry using HMTA as the complexing agent was found to be highly sensitive method for the determination of Pt/Rh. Voltammetric measurements were carried out using hanging mercury drop electrode (HMDE) as the working electrode, a glassy carbon rod as the counter and an Ag/AgCl/KClsaturated as the reference electrode. Various electrochemical parameters like deposition potential, deposition time, concentration of the ligand, supporting electrolyte etc. were optimized. The detection limit of Pt and Rh was found to be 4.38 pML−1 and 2.80 pML−1, respectively for the deposition time of 30 s. Simultaneous determination of Pt(II) and Rh(III) in water samples was possible. The method was found to be free from the commonly occurring interfering ions such as Cu(II), Cd(II), Zn(II), Pb(II), Cr(III), Cr(VI), Fe(III), Fe(II), Ni(II) and Co(II). Spike recovery tests for both Pt and Rh in tap water and sea water samples were also carried out. The method has been verified by analyzing certified reference material (WMG-1).  相似文献   

17.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

18.
Li D  Jia J  Wang J 《Talanta》2010,83(2):332-336
A bismuth-film modified graphite nanofibers-Nafion glassy carbon electrode (BiF/GNFs-NA/GCE) was constructed for the simultaneous determination of trace Cd(II) and Pb(II). The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as deposition potential, deposition time, and bismuth ion concentration were optimized for the purpose of determination of trace metal ions in 0.10 M acetate buffer solution (pH 4.5). Under optimal conditions, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L−1 for Cd(II) and 0.02 μg L−1 for Pb(II) with a 10 min preconcentration. In addition, the BiF/GNFs-NA/GCE displayed good reproducibility and selectivity, making it suitable for the simultaneous determination of Cd(II) and Pb(II) in real sample such as river water and human blood samples.  相似文献   

19.
Khan MR  Khoo SB 《The Analyst》2001,126(12):2172-2177
An epoxy-graphite tube composite electrode bulk modified with 2-mercaptobenzothiazole was investigated for the simultaneous, batch determinations of Bi(III), Hg(II) and Cu(II) by differential-pulse anodic stripping voltammetry after open circuit preconcentration of the three metal ions. Systematic optimization was studied with respect to resolution and sensitivities of the differential-pulse peaks. The resolution between peaks was quantified and employed in a window diagram approach to choose the best conditions. The developed method gave detection limits of 4.2 x 10(-9), 3.6 x 10(-9) and 9.5 x 10(-8) M for Hg(II), Bi(III) and Cu(II), respectively (S/N = 3; 3 min preconcentration). The conditions whereby simultaneous determinations could be performed in the absence of cross-interferences of the analytes were also examined. Additional selected substances in the sample background were also studied for possible interferences. The developed method was applied to the simultaneous, batch determinations of Bi(III), Hg(II) and Cu(II) in a standard sample and a human hair sample.  相似文献   

20.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号