首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
A simple, rapid and sensitive CE-fluorescence (FL) detection method for the analysis of alendronate (ALEN), a bisphosphonate drug, has been developed. Using a buffer solution of 20 mM sodium phosphate (pH 10.0) and a voltage of 24 kV, separation of ALEN in a 55-cm length (35-cm effective length) capillary was achieved in 5 min. FL detection of ALEN was performed via pre-column derivatization with 2,3-naphthalene dicarbox-yaldehyde (NDA). Linear correlation (r=0.9981, n=6) between FL intensity and analyte concentration was obtained in the range of 7-200 ng/mL ALEN. The developed CE-FL method was applied to the analysis of ALEN in human urine and plasma samples. In order to eliminate the interfering matrix components, SPE using magnetic Fe(3) O(4) @Al(2) O(3) nanoparticles as solid sorbents was employed to clean the biological fluids before CE-FL analysis. The linear ranges of ALEN in urine and plasma were 5-100 ng/mL (r = 0.9982, n = 7) and 5-70 ng/mL (r = 0.9954, n = 7), respectively. The LOD and LOQ in both urine and plasma samples were 1.5 and 5 ng/mL ALEN, respectively. Total analysis time including sample pre-treatment and CE separation was less than 1.5 h.  相似文献   

2.
Abstract

A sensitive and selective method for the determination of quinapril and its active metabolite quinaprilate in human plasma and urine is described. The method is based on isolation using C18 Bond Elut cartridges, pre-column derivatization with 9-anthryldiazo-methane and purification of the reaction mixture on CBA columns followed by reversed-phase high performance liquid chromatography with fluorometric detection. Calibration curves were linear between 20 ng and 1000 ng/ml of plasma (100-2000 ng for urine) for both substances, the lower limit of detection being 5-10 ng/ml.

The present assay procedure has been applied to monotoring plasma and urine concentrations in several pharmacokinetic studies in humans.  相似文献   

3.
A sensitive high-performance liquid chromatographic (HPLC) assay for the determination of the cyclic heptapeptide Ac-Cs-Asn-Dtc-Amf-Gly-Asp-Cys-OH (Dtc = beta,beta-dimethylthioproline, Amf = p-aminomethylphenylalanine) in human plasma has been developed. The key steps in the assay include: solid-phase extraction of the drug from plasma, chemical derivatization of the primary amino group with naphthalene-2,3-dicarboxyaldehyde in the presence of N-acetyl-D-penicillamine as a nucleophile to form a fluorescent benzo[f]isoindole derivative, and HPLC with column switching to provide the necessary chromatographic separation of the derivative from endogenous plasma components. The assay has been validated in the concentration range 1-10 ng/ml of plasma.  相似文献   

4.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (CipralanTM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20). A 10-microns ion-exchange (sulfonate) column was used with acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard. The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10-1000 ng/ml and 50-5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

5.
A stereoselective assay for the optical isomers [(S) and (R)] of 5,6-dihydro-4-[(2-methylpropyl)amino]-4H-thieno[2,3-b]thiopyran-2- sulfonamide-7,7-dioxide in human whole blood has been developed. The assay is based on direct enantiomer separation on a chiral stationary phase column of bovine serum albumin attached to silica. The effect of pH, ionic strength, column length and organic modifier on chiral separation has been studied. The assay methodology, based on high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection (252 nm), has been fully validated in the concentration range 25-250 ng/ml of each enantiomer. Since no interconversion of the isomers was observed in vivo for the clinical studies involving the single (S)-enantiomer, a more sensitive (2.5 ng/ml), non-stereoselective assay has been developed. This method, also based on HPLC with UV detection, was fully validated in whole blood, plasma and urine in the concentration range 2.5-100 ng/ml. The details of these assays, together with some representative data from a pilot human study, are also presented.  相似文献   

6.
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented.  相似文献   

7.
Alendronate is an important representative of bisphosphonates, strongly polar compounds that lack chromophores. With rare exceptions, derivatization of the analytes is necessary for bioanalysis. In this study, a rapid liquid chromatography–tandem mass spectrometry method employing pre-column derivatization was developed and validated for the determination of alendronate concentrations in human plasma. The procedure was based on derivatization with trimethylsilyldiazomethane during solid-phase extraction on a weak anion-exchange solid-phase cartridge, which integrated sample purification and derivatization into one step. The alendronate derivative was eluted with methanol. Chromatographic separation was performed on a Capcell PAK-C18 column. The total run time was 6.5 min. The calibration curve was linear in the range 1.00–1,000 ng/mL using d6-alendronate as the internal standard. The lower limit of quantification was 1.00 ng/mL. The intra- and inter-assay precision (in RSD) calculated from quality control samples was less than 15%, and the accuracy was between 98.1% and 100.2%. The validated method was successfully applied to characterize the pharmacokinetic profiles of alendronate following the intravenous infusion of 5 or 10 mg alendronate sodium to healthy volunteers.  相似文献   

8.
An assay has been developed and validated for the routine monitoring of vecuronium in plasma. It consists of solid-phase extraction using C18 disposables as sample pre-treatment, high-performance liquid chromatography and post-column ion-pair extraction with fluorimetric detection. The fluorescent anion 9,10-dimethoxyanthracene-2-sulphonate (DAS) is used as the counter ion. The detection limit is ca. 5 ng/ml in plasma with a signal-to-noise ratio of 10. The assay is also applicable for monitoring vecuronium and its potential metabolites in other biological media, e.g., urine, bile and tissue (liver, kidney) homogenates.  相似文献   

9.
A gas chromatographic-mass spectrometric procedure has been developed for the quantitation in plasma and urine of the enantiomers of rimantadine, an antiviral drug effective against type A influenza. The assay utilizes derivatization with an optically active reagent, selective ion monitoring, methane negative-ion chemical ionization (NICI) mass spectrometry and stable isotope dilution. The method has been used to measure concentrations of each rimantadine enantiomer over a range of 2.5-250 and 12.5-1250 ng/ml in the plasma and urine, respectively, of four male volunteers administered rimantadine. In plasma and urine, no differences were observed in the disposition of the unconjugated enantiomers. In urine, one enantiomer, but not both, was released following enzymatic hydrolysis.  相似文献   

10.
A single high-performance liquid chromatographic (HPLC) assay for the quantitative determination of dilevalol, the R,R isomer of labetalol, was developed for both plasma and urine. A significantly improved limit of detection for dilevalol in plasma was accomplished by extensive modification of an HPLC assay originally developed in our laboratory for labetalol. This simplified method is readily adaptable to urine and represents the first reported HPLC assay for the quantitative determination of dilevalol in this biofluid. Drug was recovered from plasma or urine by partition into diethyl ether under mildly alkaline conditions and back-extraction into dilute acid. Reversed-phase separation of dilevalol and the internal standard was accomplished on a 150 X 4.1 mm column commercially packed with a spherical (5 micron) macroporous copolymer (PRP-1). No interferences were observed in extracts obtained from drug-free plasma or urine. Selectivity for dilevalol in the presence of other beta-blockers was established. This method demonstrated a linear detector response to concentrations of unchanged drug typically observed in urine and plasma following once-a-day treatment with dilevalol hydrochloride (100-800 mg). The lowest limit of reliable quantitation was established at 1 ng/ml in plasma. The intra-assay precision (coefficient of variation) remained less than 6% at all concentrations evaluated from 1 to 800 ng/ml. In urine, the lowest limit of quantitation was validated to 20 ng/ml where the intra-assay precision (coefficient of variation) for unchanged drug was less than 4% at all concentrations evaluated up to 400 ng/ml. This method is suitable for routine quantitation of unchanged drug in human plasma and urine following the administration of therapeutically effective doses of dilevalol hydrochloride.  相似文献   

11.
A sensitive and specific capillary gas chromatographic (GC) assay was developed for the quantitation of the quaternary ammonium steroidal neuromuscular blocking drugs pancuronium (PANC), vecuronium (VEC) and pipecuronium (PIP), as well as the metabolites 3-desacetylpancuronium (3-desPANC) and 3-desacetylvecuronium (3-des VEC) in plasma, bile and urine; the putative metabolite 3-desacetylpipecuronium (3-des PIP) was extracted and quantitated only in urine. The procedure employed a single dichloromethane extraction of the iodide ion-pairs of the monoquaternary or bisquaternary ammonium compounds (including internal and external standards) from acidified, ether-washed biological fluid followed by the formation of stable O-tert.-butyldimethylsilyl derivatives at the 3-hydroxy steroidal position of the metabolites. An automated capillary GC system fitted with a nitrogen-sensitive detector and an integrator was then used to analyze and quantitate both parent compounds and their derivatized metabolites. Optimal extraction, derivatization and GC conditions, as well as short-term stability and recoveries of these drugs and metabolites in plasma, are reported. Electron ionization mass spectrometry combined with GC was used to confirm the identities of compounds eluted from the column. The assay demonstrated a 10(3)-fold linear range up to 5000 ng/ml for PANC, VEC, 3-des VEC and PIP, and lower limits of detection with adequate precision of 2 ng/ml for PANC, VEC and PIP, and 4 ng/ml for 3-des VEC; 3-des PANC was linear from 8 to 500 ng/ml while 3-des PIP was linear from 25 to 1000 ng/ml. The precision (coefficient of variation) of the calibration curves for underivatized drugs and their derivatized metabolites over the linear ranges was 2-20% and the reproducibility of the assay over a range of clinical concentrations of these drugs found in human plasma was 5-16% for PANC, 2-4% for VEC and 6-11% for PIP. No interferences were detected in the assay of plasma samples from 106 surgical patients.  相似文献   

12.
The development of a liquid chromatography/tandem mass spectrometric assay for the quantitative analysis of the novel tubulin inhibitor D-24851 in human plasma and urine is described. D-24851 and the deuterated internal standard were extracted from 250 microL of plasma or urine using hexane/ether (1:1, v/v). Subsequently, 10-microL aliquots of reconstituted extracts were injected onto an Inertsil ODS analytical column (50 x 2.0 mm i.d., 5 microm particle size). An eluent consisting of methanol/5 mM ammonium acetate, 0.004% formic acid in water (80:20, v/v) was pumped at a flow rate of 0.2 mL/min. An API 365 triple quadrupole mass spectrometer was used in the multiple reaction monitoring mode for sensitive detection. For human plasma a dynamic range of 1-1000 ng/mL was validated, and for human urine a range of 0.25-50 ng/mL. Validation was performed according to the most recent FDA guidelines and all results were within requirements. The assay has been successfully applied to support a phase I clinical trial with orally administered D-24851.  相似文献   

13.
《Analytical letters》2012,45(8):917-926
Abstract

An analytical method has been developed to measure Pt(II) in urine via derivatization and UV or HPLC analysis. A measured quantity of urine is heated briefly with diethyl ammonium diethyl-dithiocarbamate, and the resulting Pt(Et2NCS2)2 is extracted into a measured volume of chloroform. Concentrations of Pt(II) are determined by UV absorption at 346 nm or by reverse phase HPLC analysis. The detection limit for Pt(II) as its dithiocarbamate is ~ 1 ng by HPLC; the concentration limit for HPLC analysis by direct extraction was ~ 25 ng/ml. Chromatographic response was linearly related to Pt(II) concentration over the range 100-4, 000 ng/ml; dilution of more concentrated samples has extended this range to at least 30, 000 ng/ml. This method has been applied to the analysis of Pt(II) in the urine of patients who have received cis-dichlorodiamniineplatinum(II) (CDDP) chemotherapy.  相似文献   

14.
Despite the high potential offered by electrospray ionization on highly polar compounds like biphosphonates, few applications have been developed. High-performance liquid chromatography (HPLC) separation methods suitable for such molecules cannot be used in tandem with mass spectrometry (MS) due to high non-volatile salt content; at the same time the sample preparation, in biological fluids, is also a challenging problem. In the past ion-pair chromatography was mainly used in the case of HPLC-MS of biphosphonates, but no application to quantitative pharmacokinetic (PK) studies has been presented. In this study, after preliminary tests with ion-pair chromatography showing a poor sensitivity, a combined derivatization of the amino group and the biphosphonate has been developed and tested in a PK study. Using this analytical approach we were able to fully validate the quantitation of alendronate in the range of 6.667-4860.0 ng/ml in urine (sample volume 2.0 ml); each analytical run was 5.0 min long. The sensitivity achieved permitted a correct evaluation of the alendronate urinary excretion over the full period of urine collection. Sample preparation despite its complexity permitted to process and analyze up to 200 samples in a working day.  相似文献   

15.
A reversed-phase column liquid chromatographic (LC) method with electrochemical detection (ED) is described for the quantification of 2,3-dihydro-6-[3-(2-hydroxymethyl)phenyl-2-propenyl]-5-benzofuranol (compound 1), a new locally active dual inhibitor of leukotriene and prostaglandin synthesis, in plasma. After a single liquid-liquid extraction of the biological specimen, the extract was analyzed using a liquid chromatograph with an amperometric detector set at an oxidation potential of +0.55 V. The resulting chromatograms are free from endogenous interference and the limit of detection is 0.2 ng/ml. Several other analogous dihydrobenzofuranols were shown to be electrochemically active, permitting their determination using LC with ED. The described analytical method has been fully validated in the concentration range 0.5-20 ng/ml of plasma and utilized in the analysis of plasma samples from human clinical studies. The analytical methodology has also been adapted for analysis of compound 1 in human skin blister fluid after topical administration of 1.  相似文献   

16.
A highly sensitive and convenient gas chromatographic-mass spectrometric (GC-MS) method is described for the determination of 5-fluorouracil in the presence of 2'-deoxy-5-fluorouridine (which breaks down into 5-fluorouracil during ordinary GC derivatization) in biological samples such as plasma and urine. After extraction with ethyl acetate, 5-fluorouracil and 5-chlorouracil, the latter being used as an internal standard, were converted into their tert.-butyldimethylsilyl derivatives by allowing the mixture to stand for 30 min at room temperature and were assayed by electron-impact ionization GC-MS. Under these conditions, 2'-deoxy-5-fluorouridine did not decompose or interfere with the determination of 5-fluorouracil. The assay method, including the extraction and tert.-butyldimethylsilyl derivatization of 5-fluorouracil, showed good linearity in the range 0-100 ng/ml for 5-fluorouracil in plasma (detection limit 0.5 ng/ml) and urine (detection limit 1 ng/ml). The usefulness of this method was demonstrated by determining plasma concentrations of 5-fluorouracil in rats treated intravenously with 5-fluorouracil and 2'-deoxy-5-fluorouridine.  相似文献   

17.
A high-performance liquid chromatographic method has been developed which enables sensitive determination of captopril and its mixed disulphides in plasma and urine after oral administration of a new antihypertensive agent, 1-(D-3-acetylthio-2-methylpropanoyl)-L-prolyl-L-phenylalanine (DU-1219, I). Captopril is derivatized with a new reagent, N-(4-benzoylphenyl)maleimide and the derivative is extracted with chloroform and assayed using a liquid chromatograph equipped with an ultraviolet detector at 254 nm. Mixed disulphides of captopril with thiol compounds such as cysteine, glutathione and plasma proteins are reduced with tributylphosphine to form captopril, followed by derivatization with N-(4-benzoylphenyl)maleimide. Accurate determinations are possible over a concentration range of 10-500 ng/ml captopril in plasma, and 100-2500 ng/ml captopril in urine. The coefficients of variation of captopril in plasma (200 ng/ml) and urine (500 ng/ml) are 3.7% and 2.6%, respectively, and those of mixed disulphides of captopril are similar to those of captopril. Plasma levels and urinary excretion of captopril and its mixed disulphides in healthy volunteers following single oral administration of I (50 mg) have also been determined.  相似文献   

18.
A reversed-phase high-performance liquid chromatographic method for the determination of the skeletal muscle relaxant baclofen in human plasma and urine is described. Cation-exchange extraction, precolumn derivatization with o-phthaldialdehyde, and on-column concentration precede fluorimetric detection (excitation at 340 nm, emission at 460 nm). The precision of the assay was always better than 6%. Recoveries of standards added to plasma and urine were 92% and 93%, respectively. With a sample size of 0.5 ml, a detection limit of a few nanograms, and the possibility of analysing up to four samples per hour, this method is suitable for pharmacokinetic studies. An example is presented.  相似文献   

19.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10 micrometer muBondapak phenyl column with an eluting solvent of water--methanol--1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(D-(-)-alpha-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 +/- 6.3% (S.D.) in the concentration ranges of 0.1-20 microgram per 0.2 ml of plasma with a limit of detection equivalent to 0.5 microgram/ml plasma. The urine assay was validated over a concentration range of 0.025-5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 microgram/ml) using a 0.1-ml urine specimen per assay. The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

20.
A sensitive method using enantiospecific liquid chromatography/tandem mass spectrometry detection for the quantitation of S- and R-mephenytoin as well as its metabolites S- and R-nirvanol and S- and R-4'-hydroxymephenytoin in plasma and urine has been developed and validated. Plasma samples were prepared by protein precipitation with acetonitrile, while urine samples were diluted twice with the mobile phase before injection. The analytes were then separated on a chiral alpha(1)-acid glycoprotein (AGP) column and thereafter detected, using electrospray ionization tandem mass spectrometry. In plasma, the lower limit of quantification (LLOQ) was 1 ng/mL for S- and R-4'-hydroxymephenytoin and S-nirvanol and 3 ng/mL for R-nirvanol and S- and R-mephenytoin. In urine, the LLOQ was 3 ng/mL for all compounds. Resulting plasma and urine intra-day precision values (CV) were <12.4% and <6.4%, respectively, while plasma and urine accuracy values were 87.2-108.3% and 98.9-104.8% of the nominal values, respectively. The method was validated for plasma in the concentration ranges 1-500 ng/mL for S- and R-4'-hydroxymephenytoin, 1-1000 ng/mL for S-nirvanol, and 3-1500 ng/mL for R-nirvanol and S- and R-mephenytoin. The validated concentration range in urine was 3-5000 ng/mL for all compounds. By using this method, the metabolic activities of two human drug-metabolizing enzymes, cytochrome P450 (CYP) 2C19 and CYP2B6, were simultaneously characterized.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号