首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this work is to develop and validate spectrophotometric method for the determination of piroxicam in commercial dosage forms. The method is based on the chelation of the drug with Fe(III) to form pink coloured metal chelate at room temperature which absorbs maximally at 504 nm. Beer's law is obeyed over the concentration range of 8–160 μg mL?1 (A = 1.07 × 10?3 + 7.75 × 10?3 C). Under the optimized experimental conditions, proposed method is validated as per the International Conference on Harmonisation guidelines. The limits of detection and quantitation for the proposed method are 0.775 and 2.348 μg mL?1, respectively. The proposed method has been successfully applied to the determination of piroxicam in commercial dosage forms. The results are compared with the reference El‐Ries et al. spectrophotometric method.  相似文献   

2.
Cloud-point extraction (CPE) with RP-HPLC/DAD detection was used to develop a screen for six model basic drugs (paracetamol, promazine, amitriptyline, nortriptyline, clomipramine and chlorpromazine) in human plasma. These drugs’ varied hydrophobicities entail different affinities for the micelle-rich phase and CPE extraction efficiencies. Extraction recovery (except paracetamol) was above 80% and reproducibility (RSD%) ranged from 2.88 to 10.26 intraday and from 3.12 to 12.33 interday. The limits of detection were: 0.125 μg mL?1 (promazine and chlorpromazine), 0.25 μg mL?1 (amitriptyline and nortriptyline) and 0.5 μg mL?1 (paracetamol and clomipramine). The method was linear over the ranges: 0.125–1.0 μg mL?1 (promazine and chlorpromazine), 0.25–1.0 μg mL?1 (amitriptyline and nortriptyline), 0.5–1.0 μg mL?1 (clomipramine) and 0.5–10 μg mL?1 (paracetamol). The procedure is a good alternative to the SPE or LLE sample preparation usually used.  相似文献   

3.
A simple, rapid, specific, sensitive HPLC method has been developed for the determination of piroxicam in the tablet dosage form and in human plasma. The method totally eliminates solvent extraction and time-consuming separation procedures. Plasma proteins were precipitated by addition of 3:1 (v/v) acetonitrile-methanol, ZnSO4, and MgSO4 and the supernatant was injected directly on to a 250 mm × 4.6 mm, 5 μm particle Spherisorb analytical column. Acetonitrile-methanol-0.04 mol L?1 KH2PO4, 40:10:50 (v/v); pH 3.8, was used as mobile phase. The drug was detected by UV detection at 330 nm. The response was linear over the range of 0.01–10 μg mL?1 and 0.025–5 μg mL?1 in mobile phase and human plasma samples, respectively. The proposed method was used without interference from the endogenous substances, for determination of piroxicam in plasma samples obtained from healthy volunteers. The results revealed that the method would be useful in monitoring plasma levels of the drug during pharmacokinetic studies. Assay of piroxicam in its dosage forms for quality-control purposes could also be performed successfully by use of this method.  相似文献   

4.
Piroxicam is a drug with analgesic and anti‐inflammatory properties. It is present in numerous pharmaceutical preparations. Injectable forms usually contain benzyl alcohol as an excipient, which is used as a blocking anesthetic (4%) and an antiseptic (4–10%). In this work, spectrophotometric methodology was used in order to determine benzyl alcohol in piroxicam injectable formulations by applying the fourth derivative method adopting the zero‐crossing technique. The results obtained show that the method has significant advantages over other reported methods and is appropriate for routine pharmaceutical analysis. The method showed excellent linearity in the range of 2–100 μg mL?1 with limit of detection (S/N = 3) 0.07 μg mL?1 (6.47 × 10?7 M). The proposed method could be applied successfully for the determination of benzyl alcohol in injectable formulations with average % recovery of 100 ± 0.61.  相似文献   

5.
A novel packed-fiber solid phase extraction procedure based on electrospun nanofibers for simultaneous determination of vitamins A (retinol) and E (α-tocopherol) in human plasma has been developed. Parameters affecting extraction efficiency were investigated in detail. The limit of detection is 0.01 μg mL?1 for retinol, and 0.3 μg mL?1 for α-tocopherol. The linear range is from 0.05 to 2.0 μg mL?1 for retinol, and from 0.5 to 30 μg mL?1 for α-tocopherol. The precision (RSD) is <6%, and the relative recovery >90%. The method was applied to analysis of retinol and α-tocopherol in human plasma with satisfactory results.  相似文献   

6.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

7.
A simple and reliable novel kinetic method for the determination of piroxicam (PX) was proposed and validated. For quantitative determination of PX, the Bray-Liebhafsky (BL) oscillatory reaction was used in a stable non-equilibrium stationary state close to the bifurcation point. Under the optimized reaction conditions (T = 55.0°C, [H2SO4]0 = 7.60×10?2 mol L?1, [KIO3]0 = 5.90×10?2 mol L?1, [H2O2]0 = 1.50×10?1 mol L?1 and j 0 = 2.95×10?2 min?1), the linear relationship between maximal potential shift ΔE m , and PX concentration was obtained in the concentration range 11.2–480.5 μg mL?1 with a detection limit of 9.9 μg mL?1. The method had a rather good sample throughput of 25 samples h?1 with a precision RSD = 4.7% as well as recoveries RCV ≤ 104.4%. Applicability of the proposed method to the direct determination of piroxicam in different pharmaceutical formulations (tablets, ampoules and gel) was demonstrated.   相似文献   

8.
A highly sensitive spectrophotometric method for palladium determination using piroxicam and tenoxicam as new chromogenic reagents has been developed. In the presence of sodium lauryl sulfate (SLS), palladium reacts with piroxicam (PX) or tenoxicam (TX) to form stable yellow orange complexes in an acetate buffer solution of pH 5.0 at 424 nm and 426 nm with molar absorptivity of 7.16 × 104 L mol−1 cm−1 and 1.20 × 105 L mol−1 cm−1, respectively. Sandell sensitivity, detection, and quantitation limits were also calculated. Optimum conditions were evaluated considering pH, reagent concentration, time, temperature, and surfactant concentration. The complex system conforms to Beer’s law over the range of 0.07–1.28 μg mL−1 palladium. The stoichiometric ratio and stability constant were also evaluated. Tolerance limits of many cations and anions were determined. Finally, the proposed method was applied successfully in the determination of palladium in jewellery, anode mud, synthetic mixtures, catalysts, and alloy samples.  相似文献   

9.
A method for the determination of iodate was developed by reversed-phase high-performance liquid chromatography with UV detection. Iodate was converted to iodine, which was separated from the matrix using a reversed-phase Ultrasphere C18 column (250 × 4.6 mm, 5 μm) with methanol-1 mmol L?1 H3PO4 (20:80, v/v) as mobile phase at 1.00 mL min?1 and UV detection at 224 nm. The calibration graph was linear from 0.05 μg mL?1 to 5.00μg mL?1 for iodine with a correlation coefficient of 0.9994 (n=7). The detection limit was 0.01 μg mL?1. The method was successfully applied to the determination of iodate in iodized salt. The recovery was from 96% to 101% and the relative standard deviation was in the range of 1.5% to 2.9%.  相似文献   

10.
A novel kinetic method for the determination of trace amounts of Co(II) has been developed. The proposed method based on the catalytic effect of Co(II) on the oxidation of xylenol orange tetra sodium salt by H2O2 in the presence of cationic surfactant (N‐dodecylpyridinium chloride). Co(II) at μg.mL?1 was determined spectrophotometrically by measuring the decrease in the absorbance of xylenol orange at 577 nm by the differential method. The method is precise, selective, and sensitive. The detection limit of the procedure was 0.058 μg.mL?1. The relative standard deviation for the replicate determination (n = 6) of 0.7 μg.mL?1 was 1.285%. The results compared satisfactorily with those of atomic absorption spectrometry. The method was successful for the analysis of Co(II) in veterinary and synthetic samples.  相似文献   

11.
《Electroanalysis》2006,18(9):931-934
A flow injection analysis (FIA) method for the determination of paracetamol in pharmaceutical drugs using a gold electrode modified with a self‐assembled monolayer (SAM) of 3‐mercaptopropionic acid is described. At optimized experimental conditions the dynamic concentration range was 0.15 to 15.0 mg L?1 with a detection limit of 0.2 μg mL?1 (S/N=3). The repeatability of current responses for injections of 10 μmol L?1 paracetamol was evaluated to be 3.2% (n=30) and the analytical frequency was 180 h?1. The lifetime of the modified electrode was found to be 15 days. The results obtained by using the proposed amperometric method for paracetamol determination in four different drug samples compared well with those found by spectrophotometry.  相似文献   

12.
《Analytical letters》2012,45(9):1919-1932
Abstract

“Zero-crossing” derivative spectrophotometry has been used for determining binary mixtures of penicillin G and procaine penicillin G.

The procedure is rapid, simple, nondestructive, and does not require resolutions of equations.

Calibration graphs are linear between 2.0 and 50.0 μg mL?1 of the penicillin G at 226.0 nm, and between 2.0 and 100.0 μg mL?1 of procaine penicillin G at 319.0 nm, in the presence of each other. A complete and exhausive statistical analysis of the experimental data was realized to demonstrate the validity of method. The method was successfully applied to assay commercial injections of these drugs.  相似文献   

13.
A simple, sensitive, and rapid microextraction method, namely, ultrasound‐assisted surfactant‐enhanced emulsification microextraction based on the solidification of floating organic droplet method coupled with high‐performance liquid chromatography was developed for the simultaneous preconcentration and determination of nitrazepam and midazolam. The significant parameters affecting the extraction efficiency were considered using Plackett–Burman design as a screening method. To obtain the optimum conditions with consideration of the selected significant variables, a Box–Behnken design was used. The microextraction procedure was performed using 29.1 μL of 1‐undecanol, 1.36% (w/v) of NaCl, 10.0 μL of sodium dodecyl sulfate (25.0 μg mL?1), and 1.0 μL of Tween80 (25.0 μg mL?1) as an emulsifier in an extraction time of 20.0 min at pH 7.88. In order to investigate the validation of the developed method, some validation parameters including the linear dynamic range, repeatability, limit of detection, and recoveries were studied under the optimum conditions. The detection limits of the method were 0.017 and 0.086 ng mL?1 for nitrazepam and midazolam, respectively. The extraction recovery percentages for the drugs studied were above 91.0 with acceptable relative standard deviation. The proposed methodology was successfully applied for the determination of these drugs in a number of human serum samples.  相似文献   

14.
Two spectrophotometric methods, a photochemical and a non-photochemical, for the determination of ascorbic acid in soft drinks and beer using a flow-injection system are proposed. The non-photochemical method is based on the redox reaction that takes place between ascorbic acid and Fe(III), yielding dehydroascorbic acid and Fe(II). Fe(II) reacts with 1,10-phenantroline, originating the reddish orange Fe(phen)3 2+ complex (ferroin). This complex is spectrophotometrically monitored at 512 nm, and the signal is directly related to the concentration of ascorbic acid in the sample. The photochemical method has the same basis, nevertheless, uses the irradiation with visible light to enhance the redox reaction and so achieve higher sensitivities in the analysis. The non-photochemical method shows a linear range between 5 and 80 μg mL?1, with a relative standard deviation of 1.6% (n = 11), a detection limit of 2.7 μg mL?1 and a sample throughput of ¶60 samples h?1. The photochemical method shows a linear range between 1 and 80 μg mL?1, with a relative standard deviation of 1.0% (n = 11), a detection limit of 0.5 μg mL?1 and a sample throughput of 40 samples h?1.  相似文献   

15.
A method for extracting coenzyme Q10 (CoQ10) from Artemia was developed. 1 g of fresh Artemia was incubated with 75 % acetic acid at (30 ± 2)°C for 24 h, followed by three consecutive extractions with a mixture of 5 mL of hexane and 5 mL of ethanol, then analysis by a validated high-performance liquid chromatography with a diode-array detector. The calibration curve for CoQ10 was linear in a range of 1–50 μg mL?1. The limits of detection and quantification were 0.3 μg mL?1 and 1.1 μg mL?1, respectively. Mean recoveries were 94–100 % with a high precision of below 10 %. The method developed was found to be simple, efficient and the time required for releasing CoQ10 from Artemia was short. The method provides not only low energy consumption but is also practical for industrial applications.  相似文献   

16.
A very simple spectrophotometric method for simultaneous determination of aluminum(III) and iron(III) based on formation of their complexes with pyrocatechol violet (PCV) in micellar media, using the H‐point standard addition method (HPSAM), is described. In micellar media, the metal complexes of Al‐PCV and Fe‐PCV are formed very fast. Formation of both of the complexes was complete within 5 min at pH 8.5. The linear ranges for aluminum and iron were 0.05‐2.50 and 0.10‐4.00 μg mL?1, respectively. The relative standard deviation (R.S.D.) for the simultaneous determination 0.40 μg mL?1 of Al(III) and 0.20 μg mL?1 of Fe(III) were 3.24% and 4.22%, respectively. Interference effects of common anions and cations were studied. The method was applied to simultaneous determination of Al(III) and Fe(III) in standard reference material and alloy samples.  相似文献   

17.
An LC–MS/MS method with internal standard tolfenamic acid for determining diclofenac sodium (DCF) in dairy cow plasma was developed and validated. Samples were processed with protein precipitation by cold formic acid–acetonitrile. Determination of DCF was performed using LC–ESI+–MS/MS with the matrix‐matched calibration curve. The results showed that the method was sensitive (LOD 2 ng mL?1, LOQ 5 ng mL?1), accurate (97.60 ± 5.64%), precise (<10%) and linear in the range of 5–10,000 ng mL?1. A single intravenous (i.v.) or intramuscular (i.m.) administration of 5% diclofenac sodium injection at a dose of 2.2 mg kg?1 was performed in six healthy dairy cows according to a two‐period crossover design. The main pharmacokinetic (PK) parameters after a single i.v. administration were as follows: t1/2β, 4.52 ± 1.71 h; AUC, 77.79 ± 16.76 h μg mL?1; mean residence time, 5.16 ± 1.11 h. The main PK parameters after a single i.m. administration were as follows: Tmax, 2.38 ± 1.19 h; Cmax, 7.46 ± 1.85 μg mL?1; t1/2β, 9.46 ± 2.86 h; AUC 67.57 ± 13.07 h μg mL?1. The absolute bioavailability was 87.37 ± 5.96%. The results showed that the diclofenac sodium injection had PK characteristics of rapid absorption and slow elimination, and high peak concentration and bioavailability in dairy cows, and that the recommended clinical dosage of diclofenac sodium injection is 2.2 mg kg?1.  相似文献   

18.
A liquid chromatographic method for the simultaneous determination of three flavonoids, scutellarin (SCU), isoscutellarein-8-O-glucuronide (ISO) and luteolin (LUT) in rat plasma was developed and validated. Following a single-step liquid–liquid extraction with ethyl acetate, the analytes and internal standard (IS) (rutin) were successfully separated on a Diamonsil C18 column using a mobile phase composed of acetonitrile (A)–0.2% phosphoric acid aqueous solution (B) (0–5 min, 20% A–29% A; 5–25 min, 29% A, v/v) at a flow rate of 1.0 mL min?1. The linear range was 0.044–2.20 μg mL?1 for SCU, 0.042–2.08 μg mL?1 for ISO, and 0.056–2.80 μg mL?1 for LUT, with the correlation coefficients of 0.9995, 0.9989 and 0.9963, respectively. The limit of quantification of SCU, ISO and LUT were 44, 41.6 and 56 ng mL?1, respectively. The accuracy of assay was between 88.4 and 103.0%. The inter-day and intra-day precisions (RSD) were less than 10.5%. The developed method was simple, rapid and applied successfully to study the pharmacokinetics of SCU, ISO and LUT after oral administration of the total flavonoids of Scutellaria barbata.  相似文献   

19.
《Analytical letters》2012,45(4):797-807
Abstract

A fast and simple flow injection chemiluminescence method for the determination of trace amounts of tetracyclines is proposed based on the chemiluminescence of the KMnO4 - TCs redox reaction in acidic medium in the presence of a sensitizer, OP. The response to the concentration of tetracyclines is linear in the range of 1.00 to 1000 μg mL?1 with a relative standard deviation < 2.3 % for determination of 50.0 μg mL?1 of each antibiotic (n = 11). The detection limits for tetracycline, oxytetracycline and chlortetracycline are 0.40, 0.52 and 0.60 μg mL?1, respectively. The recommended method is suitable for automatic and continuous analysis and has been successfully tested for determination of tetracyclines in commercial formulations. The chemiluminescence intensity was found to be remarkably enhanced when in the presence of OP micellar system; possible reasons for this observed micellar induced enhanced chemiluminescence is given.  相似文献   

20.
A simple, sensitive and accurate spectrophotometric method has been described for the determination of ampicillin(I), amoxicillin trihydrate(II) and cefazolin sodium(III). The procedure is based on the formation of Prussian Blue (PB) complex. The reaction between the acidic hydrolysis products of antibiotics (T = 60 °C) with mixture of Fe3+ and hexacyanoferrate(III) ions was evaluated for the spectrophotometric determination of the mentioned drugs. The maximum absorbance of the colored complex occurs at λ = 700 nm and the molar absorptivity is 3.0 × 104 1 mol?1cm?1. The effect of various parameters such as concentration of K3Fe(CN)6 and Fe3+, nature and amount of acids used, temperature and time of heating were investigated. Under optimum conditions the linear range of calibration graph was 2.0–12.0, 5.0–13.5 and 3.0–12.0 μg mL?1 for ampicillin, amoxicillin and cefazolin, respectively. The relative standard deviation for the determination of 10 μg mL?1 of antibiotics was about 0.5–1.5%. The proposed method was successfully applied to the determination of selected antibiotics from pharmaceutical preparations. The validity of the method was tested by the official methods and by the recovery studies of standard addition to pharmaceuticals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号