首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
基于分布链修正的磁流变弹性体的物理模型   总被引:7,自引:0,他引:7  
在考虑磁流变弹性体中链的方向分布的基础上,对磁流变弹性体的偶极子模型作出了修正.用局部场的方法计算了链的势能,引入了分布函数来描述链的分布,并分析了与磁场方向不一致的斜链的磁流变效应,进而通过积分叠加求得含有分布链的磁流变弹性体的磁流变效应.在磁流变弹性体的理论模型中,引入了制备磁场和基体性质等影响因素.  相似文献   

2.
We have studied the effect of electron–electron interaction in the presence of mixed disorder on the conductivity and Hall effect of a high-mobility two-dimensional electron gas in a GaAs/AlGaAs heterostructure. A parabolic, negative, temperature-dependent magnetoresistance (MR) and temperature-dependent Hall effect are observed. We show that these effects can be explained in terms of the interaction theory. In addition, a temperature independent, positive MR is observed. This classical MR is also shown to be a consequence of the mixed disorder.  相似文献   

3.
We present an extensive study of a large, room temperature magnetoresistance (MR) effect in tris-(8-hydroxyquinoline) aluminum sandwich devices. The effect is similar to that previously discovered in π-conjugated polymer devices. We characterize this effect and discuss its dependence on magnetic field direction, voltage, temperature, film thickness, and electrode materials. The MR effect reaches almost 10% at fields of 10 mT at room temperature. The effect shows only a weak temperature dependence and is independent of the sign and direction of the magnetic field. Measuring the devices' current-voltage characteristics, we find that the current depends on the voltage through a power-law. We find that the magnetic field changes the prefactor of the power-law. We also studied the effect of the magnetic field on the electroluminescence (MEL) of the devices and analyze the relationship between MR and MEL.  相似文献   

4.
The angle between the straight axial plane and the orbito-meatal line was measured in 156 consecutive magnetic resonance examinations. Inconsistent head positioning caused this angle to vary by as much as 44 degrees. Careful positioning of the patient by the technologist can minimize this variability, leading potentially to improved image interpretation. To assess the merit of a standardized orientation for MR examinations of the head, straight axial and tilted axial MR scans were compared in 34 patients. The tilted images were obtained parallel to the orbito-meatal line and were found to be superior for visualization of the cerebellum. When correlative x-ray CTs are available or when an abnormality in the posterior fossa is suspected, tilted axial MR scans should be employed.  相似文献   

5.
In this work, properties of a magnetorheological (MR) fluid, prepared by dispersing a mixture of two types of carbonyl iron powders (CIPs) of different sizes, in an ionic liquid (N,N-diethyl-N-methyl-N-(2-methoxyethyl) ammonium tetrafluoroborate) that is stable from 9 °C to ca. 300 °C, have been investigated. At first, the random packing density of the mixture was computed as function of mixing ratio of CIP, in order to find out the tendency of the variation. Next, several mixtures, all having the same weight, were prepared at various mixing ratios and dispersed in the ionic liquid, in order to experimentally find the most suitable mixing ratio of CIP. Then, the magnetic clusters of the synthesized MR fluids were observed by using a digital microscope equipped with two permanent magnets, whereas the MR properties were investigated by using a rotation viscometer equipped with a solenoid coil. The experimental results pointed out that the MR fluid with 60 wt% fraction of large particles exhibited the highest MR response.  相似文献   

6.
The purpose of this investigation was to analyze the normal anatomy and leiomyomas of the uterus with an ultra low field (0.02 T) magnetic resonance imaging (MRI) device. MR imaging was performed on 18 uteri, 11 of which were imaged both preoperatively (in vivo) and as an operative specimen (in vitro), 6 only as an operative specimen, and 1 only preoperatively. All uteri were examined histologically after imaging. The junctional zone was much better delineated in vivo than in vitro, indicating that its appearance on MR is partly due to blood flow. No structures contributing to its visibility in vitro could be demonstrated histologically. Twenty leiomyomas (size range 7–79 mm) in 12 uteri were found with MRI. They were slightly better discerned in vivo than in vitro. The leiomyomas, having no degenerative changes, had a signal intensity which was the same or lower than that of the myometrium. On images obtained in vitro the signal intensity of these leiomyomas relative to that of myometrium correlated directly with their muscular content (R = 0.74, p = .002). The authors conclude that the junctional zone is a sum of physiological and structural factors, the latter being responsible for its in vitro delineation. MR imaging of the uterus in vitro did not give more information than MR imaging in vivo. All leiomyomas larger than 10 mm could be detected, indicating that MR imaging at 0.02 T is an accurate method for the imaging of the uterine leiomyomas.  相似文献   

7.

Purpose

This study aimed to develop a 0.014-in., anti-solenoid loop (ASL) magnetic resonance imaging guidewire (MRIG) for intravascular 3.0-T MR imaging.

Materials and Methods

We first designed the ASL MRIG, which was made of a coaxial cable with its extended inner conductor and outer conductor connected to two micro-anti-solenoids. We then evaluated in vitro the functionality of the ASL MRIG by imaging a “vessel” in a phantom and achieving signal-to-noise ratio (SNR) and SNR contour map of the new 0.014-in. ASL MRIG. Subsequently, we validated in vivo the feasibility of using the ASL MRIG to generate intravenous 3.0-T MR images of parallel iliofemoral arteries of near-human-sized living pigs.

Results

In vitro evaluation showed that the 0.014-in. ASL MRIG functioned well as a receiver coil with the 3.0-T MR scanner, clearly displaying the vessel wall with even distribution of MR signals and SNR contours from the ASL MRIG. Of the in vivo studies, the new ASL MRIG enabled us to successfully generate intravenous 3.0-T MR imaging of the iliofemoral arteries.

Conclusion

This study confirms that it is possible to build such small-looped MRIG at 0.014 in. for intravascular 3.0-T MR imaging.  相似文献   

8.
磁流变减振系统参数辨识   总被引:2,自引:0,他引:2  
在对磁流变体的力学性能、减振系统设计和实验建模方法深入研究的基础上,提出了采用非线性顺序滤波来辨识磁流变化减振装置粘弹性模型参数的实验建模方法。研究表明,基于粘塑性假设,可用于该辨识算法获得库仑摩擦力和粘性摩擦系数。  相似文献   

9.
The magnetoresistance (MR) effect is theoretically investigated in a periodic magnetically modulated nanostructure, which can be realized experimentally by depositing periodic parallel ferromagnetic strips on the top of a heterostructure. We find that there exists a significant conductance difference for electrons through the parallel (P) and antiparallel (AP) magnetization configurations, which results in a considerable magnetoresistance effect. We also find that the magnetoresistance effect depends not only on the temperature but also on the number of the periodic magnetic barriers.  相似文献   

10.
Accurate segmentation of magnetic resonance (MR) images remains challenging mainly due to the intensity inhomogeneity, which is also commonly known as bias field. Recently active contour models with geometric information constraint have been applied, however, most of them deal with the bias field by using a necessary pre-processing step before segmentation of MR data. This paper presents a novel automatic variational method, which can segment brain MR images meanwhile correcting the bias field when segmenting images with high intensity inhomogeneities. We first define a function for clustering the image pixels in a smaller neighborhood. The cluster centers in this objective function have a multiplicative factor that estimates the bias within the neighborhood. In order to reduce the effect of the noise, the local intensity variations are described by the Gaussian distributions with different means and variances. Then, the objective functions are integrated over the entire domain. In order to obtain the global optimal and make the results independent of the initialization of the algorithm, we reconstructed the energy function to be convex and calculated it by using the Split Bregman theory. A salient advantage of our method is that its result is independent of initialization, which allows robust and fully automated application. Our method is able to estimate the bias of quite general profiles, even in 7T MR images. Moreover, our model can also distinguish regions with similar intensity distribution with different variances. The proposed method has been rigorously validated with images acquired on variety of imaging modalities with promising results.  相似文献   

11.

Background

Using magnetic resonance (MR) imaging for navigating catheters has several advantages when compared with the current “gold standard” modality of X-ray imaging. A significant drawback to interventional MR is inferior temporal and spatial resolutions, as high spatial resolution images cannot be collected and displayed at rates equal to X-ray imaging. In particular, passive MR catheter tracking experiments that use positive contrast mechanisms have poor temporal imaging rates and signal-to-noise ratio. As a result, with passive methods, it is often difficult to reconstruct motion artifact-free tracking images from areas with motion, such as the thoracic cavity.

Methods

In this study, several accelerated MR acquisition strategies, including parallel imaging and compressed sensing (CS), were evaluated to determine which method is most effective at improving the frame rate and passive detection of catheters in regions of physiological motion. Device navigation was performed both in vitro, through the aortic arch of an anthropomorphic chest phantom, and in vivo from the femoral artery, up the descending aorta into the supra-aortic branching vessels in canines.

Results and Discussion

The different parallel imaging methods produced images of low quality. CS with a two-fold acceleration was found to be the most effective method for generating tracking images, improving the image frame rate to 5.2 Hz, while maintaining a relatively high in-plane resolution. Using CS, motion artifact was decreased and the catheters were visualized with good conspicuity near the heart.

Conclusions

The improvement in the imaging frame rate by image acceleration was sufficient to overcome motion artifacts and to better visualize catheters in the thoracic cavity with passive tracking. CS preformed best at tracking. Navigation with passive MR catheter tracking was demonstrated from the femoral artery to the carotid artery in canines.  相似文献   

12.
Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (~-21 dB) and transmission coefficient S12 (~-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm(3) isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.  相似文献   

13.
We study the magnetoresistance (MR) of two domains with an induced pinning center. At large pinning, we find that the MR can be described as the one corresponding to tunneling between two single uniformly magnetized domains. We model the MR in manganite bicrystals and obtain a remarkable agreement with various experiments. This study solves an apparent contradiction between experiments. We predict new behaviors depending on field orientation and the angle between crystals.  相似文献   

14.
High-resolution MR venography of cerebral arteriovenous malformations   总被引:20,自引:0,他引:20  
The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel sized vessel diameters of several hundred microns. The method is based on the paramagnetic property of deoxyhemoglobin, and the resulting developing phase difference between veins and brain parenchyma at long echo times which leads to signal cancellation. The reconstructed venograms were compared with time-of-flight (TOF)-MR angiography using qualitative and quantitative criteria with the conventional digital subtraction angiography serving as the reference gold standard. In 17 patients with angiographically proven cerebral AVMs, the method indicates its potential in clinical applications. Venography was able to detect all AVMs whereas TOF-MRA failed in three patients. In the delineation of venous drainage patterns MR venography was superior to TOF-MRA, however, the method failed in the detection of about half of the main feeding arteries, as expected. Due to susceptibility artifacts at air/tissue boundaries and interference with paramagnetic hemosiderin, venography was limited with respect to the delineation of the exact nidus sizes and shapes in ten patients with AVMs located close to the skull base or having suffered from previous bleeding. Although the visualization of draining veins represents an important prerequisite in the surgical and radiosurgical treatment planning of cerebral AVMs, application of high resolution MR venography may be limited in the diagnostic work-up in some of these patients. On the other hand, it may be of special importance in the early detection and assessment of small AVMs that are difficult to diagnose with other MR methods.  相似文献   

15.
PURPOSE: The purpose of this study was to evaluate differences in the degrees of contrast enhancement effects of small hepatocellular carcinomas (HCCs) in patients with cirrhosis between helical computed tomography (CT) and magnetic resonance (MR) imaging during multiphasic contrast-enhanced dynamic imaging and to determine the diagnostic value of MR imaging especially in assessing hypovascular HCCs detected as hypoattenuating nodules on late-phase CT. SUBJECTS AND METHODS: This study included 64 small HCCs (<3 cm in diameter) in 40 patients with chronic hepatitis or cirrhosis who underwent multiphasic (arterial, portal and late phases) contrast-enhanced dynamic helical CT and MR imaging. The contrast enhancement patterns of each lesion in the arterial and late phases were evaluated by two radiologists experienced in liver MR imaging and categorized as one of five grades (1=hypoattenuated/hypointense; 2=slightly hypoattenuated/hypointense; 3=isoattenuated/isointense; 4=slightly hyperattenuated/hyperintense; 5=hyperattenuated/hyperintense), compared with the surrounding liver parenchyma. RESULT: Forty-three (67%) of 64 lesions showed Grade 4 (n=24) or Grade 5 (n=19) enhancement on arterial-phase CT, while 51 (80%) of 64 lesions showed Grade 4 (n=20) or Grade 5 (n=31) enhancement on arterial-phase MR imaging, indicating hypervascular HCCs. The grading score of hypervascular HCCs on arterial-phase MR imaging (mean: 4.61) was significantly (P<.01) higher than that for hypervascular HCCs on arterial-phase CT (mean: 4.20), showing better detection of the hypervascularity (arterial enhancement) of the lesion on arterial-phase MR imaging. Regarding hypovascular HCCs, all (100%) of 21 hypovascular HCCs on CT showed Grade 1 (n=10) or Grade 2 (n=11) enhancement on late-phase CT, seen as hypoattenuation. In contrast, 8 (62%) of 13 hypovascular HCCs on MR imaging showed Grade 1 (n=1) or Grade 2 (n=7) enhancement on late-phase MR imaging, seen as hypointensity. Grading scores of hypovascular HCCs on late-phase images were significantly (P<.001) lower on CT than on MR imaging (mean score: 1.52 vs. 2.31), indicating better washout effects for hypovascular HCCs on late-phase CT. CONCLUSION: The washout effects for small HCCs on late-phase MR imaging were inferior to those for small HCCs on late-phase CT. Especially, hypovascular HCCs demonstrated as hypoattenuating nodules on late-phase CT were often not seen on late-phase MR imaging, requiring careful evaluation of other sequences, including unenhanced T(1)-weighted and T(2)-weighted MR images.  相似文献   

16.
Qian Zhang 《中国物理 B》2022,31(6):65203-065203
Relativistic magnetic reconnection (MR) driven by two ultra-intense lasers with different spot separation distances is simulated by a three-dimensional (3D) kinetic relativistic particle-in-cell (PIC) code. We find that changing the separation distance between two laser spots can lead to different magnetization parameters of the laser plasma environment. As the separation distance becomes larger, the magnetization parameter σ becomes smaller. The electrons are accelerated in these MR processes and their energy spectra can be fitted with double power-law spectra whose index will increase with increasing separation distance. Moreover, the collisionless shocks' contribution to energetic electrons is close to the magnetic reconnection contribution with σ decreasing, which results in a steeper electron energy spectrum. Basing on the 3D outflow momentum configuration, the energetic electron spectra are recounted and their spectrum index is close to 1 in these three cases because the magnetization parameter σ is very high in the 3D outflow area.  相似文献   

17.
孙志刚  庞雨雨  胡靖华  何雄  李月仇 《物理学报》2016,65(9):97301-097301
采用溶胶凝胶法以及静电纺丝法, 利用热处理工艺, 成功制备出了多晶锐钛矿型TiO2纳米线, 通过两线法在室温下测试单根TiO2纳米线的V-I曲线来研究其电输运性能及磁阻效应. 结果表明: 在无光照环境下其V-I曲线为不过零点的直线, 零场电阻较大, 在磁场作用下电阻下降, 表现出负磁阻效应; 紫外光辐照环境下TiO2纳米线载流子浓度增加使得电阻变小, 然而在磁场作用下电阻增大, 表现为正磁阻效应. 紫外光辐照导致的载流子浓度变化, 使得负磁阻转变为正磁阻, 我们将磁阻变化归结为d电子局域导致的负磁阻与能带劈裂导致的正磁阻两种机理相互竞争的结果.  相似文献   

18.
Peripheral MR angiography requires high resolution and arterial contrast. Neither can be obtained simultaneously due to the short arterial phase of the contrast agent. To improve temporal resolution, keyhole imaging was developed, which combines high resolution and arterial k-spaces at the time of image acquisition. Here, a related approach is introduced for image post-processing in the Fourier domain. It is demonstrated that simple substitution of the central k-space with low-resolution data leads to severe distortion. Hence, a dedicated calculation scheme is necessary for composite k-space post-processing. A solution is presented for high-resolution arterial peripheral MR angiography that uses subtraction of venous intensities from the central high-resolution k-space. The calculations in the Fourier domain do not require interpolations between the different resolutions. High-resolution steady-state MR angiography, which exhibits contrast-enhanced arteries and veins at an isotropic resolution of 0.65 mm, and standard resolution arterial first-pass MR angiography were combined to obtain images with the resolution of the steady-state images and arterial contrast. Numerical simulations on software phantoms are presented. The operation of the method is demonstrated in five patients.  相似文献   

19.
The MR findings in a 32-year-old man with pancreatic VIPoma and liver metastases are described. A 2-cm mass was present in the region of the tail of the pancreas that was best shown on T1-weighted fat-suppressed images as a low-signal intensity mass. Multiple liver metastases were present that showed intense peripheral ring enhancement on immediate post gadolinium spoiled gradient echo images.  相似文献   

20.
Compressed sensing (CS) and partially parallel imaging (PPI) enable fast magnetic resonance (MR) imaging by reducing the amount of k-space data required for reconstruction. Past attempts to combine these two have been limited by the incoherent sampling requirement of CS since PPI routines typically sample on a regular (coherent) grid. Here, we developed a new method, “CS+GRAPPA,” to overcome this limitation. We decomposed sets of equidistant samples into multiple random subsets. Then, we reconstructed each subset using CS and averaged the results to get a final CS k-space reconstruction. We used both a standard CS and an edge- and joint-sparsity-guided CS reconstruction. We tested these intermediate results on both synthetic and real MR phantom data and performed a human observer experiment to determine the effectiveness of decomposition and to optimize the number of subsets. We then used these CS reconstructions to calibrate the generalized autocalibrating partially parallel acquisitions (GRAPPA) complex coil weights. In vivo parallel MR brain and heart data sets were used. An objective image quality evaluation metric, Case-PDM, was used to quantify image quality. Coherent aliasing and noise artifacts were significantly reduced using two decompositions. More decompositions further reduced coherent aliasing and noise artifacts but introduced blurring. However, the blurring was effectively minimized using our new edge- and joint-sparsity-guided CS using two decompositions. Numerical results on parallel data demonstrated that the combined method greatly improved image quality as compared to standard GRAPPA, on average halving Case-PDM scores across a range of sampling rates. The proposed technique allowed the same Case-PDM scores as standard GRAPPA using about half the number of samples. We conclude that the new method augments GRAPPA by combining it with CS, allowing CS to work even when the k-space sampling pattern is equidistant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号