首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Functional magnetic resonance imaging (fMRI) is widely used to pinpoint active brain areas. Changes in neuronal activity modulate the local blood oxygenation level, and the associated modulation of the magnetic field homogeneity can be detected with magnetic resonance imaging. Thus, the blood oxygenation level-dependent (BOLD) fMRI indirectly measures neuronal activity. Similar modulation of magnetic field homogeneity was here elicited by other means to generate a BOLD-like change in a new phantom constructed to provide reference activations during fMRI. Magnetic inhomogeneities were produced by applying current to coils located near the phantom containing 1.5 ml of Gd-doped water. The signal-to-noise ratio of the images, produced by gradient-recalled echo-planar imaging, varied between 104 and 107 at a selected voxel when the field was and was not inhomogenized, respectively. The contrast of signals between homogeneous and inhomogeneous conditions was generally stable, except in 3% of time points. During the periods of greatest deviations an observable change would have been detected in a simultaneously measured BOLD signal. Such changes could result from the imaging method or occur through glitches in hardware or alterations in the measurement environment. With identical measurement setups, the phantom could allow comparing intersession or intersubject brain activations.  相似文献   

2.
For the first time, we demonstrate here functional magnetic resonance imaging (fMRI) using intermolecular multiple-quantum coherences (iMQCs). iMQCs are normally not observed in liquid-state NMR because dipolar interactions between spins average to zero. If the magnetic isotropy of the sample is broken through the use of magnetic field gradients, dipolar couplings can reappear, and hence iMQCs can be observed. Conventional (BOLD) fMRI measures susceptibility variations averaged over each voxel. In the experiment performed here, the sensitivity of iMQCs to frequency variations over mesoscopic and well-defined distances is exploited. We show that iMQC contrast is qualitatively and quantitatively different from BOLD contrast in a visual stimulation task. While the number of activated pixels is smaller in iMQC contrast, the intensity change in some pixels exceeds that of BOLD contrast severalfold.  相似文献   

3.
Stray field imaging has been extensively utilized in the last 10 years to perform very high resolution imaging of samples in a single dimension using the massive field gradient present in the fringe of a superconducting magnet. By spinning the sample around the magic-angle, the stray field gradient is successively reoriented along three orthogonal directions in the sample reference frame, allowing the acquisition of a full three-dimensional Fourier image, thereby providing the possibility to perform multi-dimensional very high-resolution imaging with standard nuclear magnetic resonance spectroscopy equipment. Here, we show multi-dimensional images demonstrating the feasibility of this technique.  相似文献   

4.
In functional magnetic resonance imaging (fMRI) studies, an elevation in blood pressure (BP) in individuals with a poor autoregulatory response may increase cerebral blood flow, potentially enhancing the blood oxygenation level dependent response. To investigate the role of BP changes, the cerebral activation to either tonic pain or the infusion of the vasopressor norepinephrine was correlated with the accompanying BP changes in alpha-chloralose anesthetized rats. Immediately after formalin (2%) injection into the forepaw, fMRI detected an activation that was correlated with the BP increase and additional activations that were independent of blood pressure changes 5–40 minutes later. The activation detected with the administration of the vasopressor norepinephrine, which does not cross the blood-brain barrier was correlated to both the amount and rate of increase in BP. The response ranged from being sparse, localized within cortex or widespread during modest, moderate or severe elevations in BP, respectively. The cerebral circulatory effects of hypertension should be considered as contributing to changes in cerebral blood oxygenation in fMRI studies involving increases in BP.  相似文献   

5.
6.
Functional magnetic resonance imaging (fMRI) at high magnetic field strength can suffer from serious degradation of image quality because of motion and physiological noise, as well as spatial distortions and signal losses due to susceptibility effects. Overcoming such limitations is essential for sensitive detection and reliable interpretation of fMRI data. These issues are particularly problematic in studies of awake animals. As part of our initial efforts to study functional brain activations in awake, behaving monkeys using fMRI at 4.7 T, we have developed acquisition and analysis procedures to improve image quality with encouraging results.We evaluated the influence of two main variables on image quality. First, we show how important the level of behavioral training is for obtaining good data stability and high temporal signal-to-noise ratios. In initial sessions, our typical scan session lasted 1.5 h, partitioned into short (<10 min) runs. During reward periods and breaks between runs, the monkey exhibited movements resulting in considerable image misregistrations. After a few months of extensive behavioral training, we were able to increase the length of individual runs and the total length of each session. The monkey learned to wait until the end of a block for fluid reward, resulting in longer periods of continuous acquisition. Each additional 60 training sessions extended the duration of each session by 60 min, culminating, after about 140 training sessions, in sessions that last about 4 h. As a result, the average translational movement decreased from over 500 μm to less than 80 μm, a displacement close to that observed in anesthetized monkeys scanned in a 7-T horizontal scanner.Another major source of distortion at high fields arises from susceptibility variations. To reduce such artifacts, we used segmented gradient-echo echo-planar imaging (EPI) sequences. Increasing the number of segments significantly decreased susceptibility artifacts and image distortion. Comparisons of images from functional runs using four segments with those using a single-shot EPI sequence revealed a roughly twofold improvement in functional signal-to-noise-ratio and 50% decrease in distortion. These methods enabled reliable detection of neural activation and permitted blood-oxygenation-level-dependent-based mapping of early visual areas in monkeys using a volume coil.In summary, both extensive behavioral training of monkeys and application of segmented gradient-echo EPI sequence improved signal-to-noise ratio and image quality. Understanding the effects these factors have is important for the application of high field imaging methods to the detection of submillimeter functional structures in the awake monkey brain.  相似文献   

7.
Access to Magnetic Resonance Imaging (MRI) across developing countries ranges from being prohibitive to scarcely available. For example, eleven countries in Africa have no scanners. One critical limitation is the absence of skilled manpower required for MRI usage. Some of these challenges can be mitigated using autonomous MRI (AMRI) operation. In this work, we demonstrate AMRI to simplify MRI workflow by separating the required intelligence and user interaction from the acquisition hardware. AMRI consists of three components: user node, cloud and scanner. The user node voice interacts with the user and presents the image reconstructions at the end of the AMRI exam. The cloud generates pulse sequences and performs image reconstructions while the scanner acquires the raw data. An AMRI exam is a custom brain screen protocol comprising of one T1-, T2- and T2*-weighted exams. A neural network is trained to incorporate Intelligent Slice Planning (ISP) at the start of the AMRI exam. A Look Up Table was designed to perform intelligent protocolling by optimizing for contrast value while satisfying signal to noise ratio and acquisition time constraints. Data were acquired from four healthy volunteers for three experiments with different acquisition time constraints to demonstrate standard and self-administered AMRI. The source code is available online. AMRI achieved an average SNR of 22.86 ± 0.89 dB across all experiments with similar contrast. Experiment #3 (33.66% shorter table time than experiment #1) yielded a SNR of 21.84 ± 6.36 dB compared to 23.48 ± 7.95 dB for experiment #1. AMRI can potentially enable multiple scenarios to facilitate rapid prototyping and research and streamline radiological workflow. We believe we have demonstrated the first Autonomous MRI of the brain.  相似文献   

8.
In this study new evaluation strategies for comparing different Statistical Parametric Maps computed from fMRI time-series analysis software tools are proposed. The aim of our work is to assess and quantitatively evaluate the statistical agreement of activation maps. Some pre-processing steps are necessary to compare SPMs (Statistical Parametric Maps), including segmentation and co-registration. The study of the statistical agreement is carried out following two ways. The first way considers SPMs as the result of two classification processes and extracts confusion matrix and Cohen's kappa index to assess agreement. Some considerations will be made on the statistical dependence of classes and a new formulation of kappa index will be used for overcoming this problem. The second way considers SPMs as two 3D images, and computes the similarity of SPMs images with a fuzzy formulation of the Jaccard Index. Several experiments were conducted both to assess the performance of the proposed evaluation tools and to compare activation maps computation pipelines from two widely used software tools in a clinical context.  相似文献   

9.
An electropolished magnetic needle made of Nd(2)Fe(14)B permanent magnet was used for obtaining better spatial resolution than that achieved in our previous work. We observed the magnetic field gradient |G(Z)|=80.0G/microm and the field strength B=1250G at Z approximately 8.8 microm from the top of the needle. The use of this needle for three dimensional magnetic resonance force microscopy at room temperature allowed us to achieve the voxel resolution to be 0.6 microm x 0.6 microm x 0.7 microm in the reconstructed image of DPPH phantom. The acquisition time spent for the whole data collection over 64 x 64 x 16 points, including an iterative signal average by six times per point, was about 10 days.  相似文献   

10.
11.
磁共振成象新进展   总被引:2,自引:0,他引:2  
叶朝辉 《物理》2004,33(1):12-17
磁共振成象(MRI)已经成为生命科学研究和医疗诊断的有力手段,因此荣获2003年诺贝尔生理学或医学奖.文章概述了磁共振成象的新近进展,包括医疗成象、脑功能成象、显微成象、活体磁共振波谱等方面.  相似文献   

12.
13.
《Comptes Rendus Physique》2010,11(2):136-148
Magnetic resonance imaging (MRI) and fast field-cycling (FFC) NMR are both well-developed methods. The combination of these techniques, namely fast field-cycling magnetic resonance imaging (FFC-MRI) is much less well-known. Nevertheless, FFC-MRI has a number of significant applications and advantages over conventional techniques, and is being pursued in a number of laboratories. This article reviews the progress in FFC-MRI over the last two decades, particularly in the areas of Earth's field and pre-polarised MRI, as well as free radical imaging using field-cycling Overhauser MRI. Different approaches to magnet design for FFC-MRI are also described. The paper then goes on to discuss recent techniques and applications of FFC-MRI, including protein measurement via quadrupolar cross-relaxation, contrast agent studies, localised relaxometry and FFC-MRI with magnetisation-transfer contrast.  相似文献   

14.
Electric current-induced phase alternations have been imaged by fast magnetic resonance image (MRI) technology. We measured the magnetic resonance phase images induced by pulsed current stimulation from a phantom and detected its sensitivity. The pulsed current-induced phase image demonstrated the feasibility to detect phase changes of the proton magnetic resonance signal that could mimic neuronal firing. At the present experimental setting, a magnetic field strength change of 1.7 +/- 0.3 nT can be detected. We also calculated the averaged value of the magnetic flux density BT parallel to B0 produced by electric current I inside the voxel as a function of the wire position. The results of the calculation were consistent with our observation that for the same experimental setting the current-induced phase change could vary with location of the wire inside the voxel. We discuss our findings in terms of possible direct MRI detection of neuronal activity.  相似文献   

15.
We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nm slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nm. This was achieved by force detection of the magnetic resonance, magnetic resonance force microscopy (MRFM), in combination with optical pumping to increase the nuclear spin polarization. Optical pumping of the GaAs created spin polarization up to 12 times larger than the thermal nuclear spin polarization at 5K and 4T. The experiment was sensitive to sample volumes of 50 microm(3) containing approximately 4 x 10(11)71 Ga/Hz. These results demonstrate the ability of force-detected magnetic resonance to apply magnetic resonance imaging to semiconductor devices and other nanostructures.  相似文献   

16.
Effects of sound level on auditory cortical activation are seen in neuroimaging data. However, factors such as the cortical response to the intense ambient scanner noise and to the bandwidth of the acoustic stimuli will both confound precise quantification and interpretation of such sound-level effects. The present study used temporally "sparse" imaging to reduce effects of scanner noise. To achieve control for stimulus bandwidth, three schemes were compared for sound-level matching across bandwidth: component level, root-mean-square power and loudness. The calculation of the loudness match was based on the model reported by Moore and Glasberg [Acta Acust. 82, 335-345 (1996)]. Ten normally hearing volunteers were scanned using functional magnetic resonance imaging (tMRI) while listening to a 300-Hz tone presented at six different sound levels between 66 and 91 dB SPL and a harmonic-complex tone (F0= 186 Hz) presented at 65 and 85 dB SPL. This range of sound levels encompassed all three bases of sound-level matching. Activation in the superior temporal gyrus, induced by each of the eight tone conditions relative to a quiet baseline condition, was quantified as to extent and magnitude. Sound level had a small, but significant, effect on the extent of activation for the pure tone, but not for the harmonic-complex tone, while it had a significant effect on the response magnitude for both types of stimulus. Response magnitude increased linearly as a function of sound level for the full range of levels for the pure tone. The harmonic-complex tone produced greater activation than the pure tone, irrespective of the matching scheme for sound level, indicating that bandwidth had a greater effect on the pattern of auditory activation than sound level. Nevertheless, when the data were collapsed across stimulus class, extent and magnitude were significantly correlated with the loudness scale (measured in phons), but not with the intensity scale (measured in SPL). We therefore recommend the loudness formula as the most appropriate basis of matching sound level to control for loudness effects when cortical responses to other stimulus attributes, such as stimulus class, are the principal concern.  相似文献   

17.
18.
19.
20.
An extended image analysis and classification system is presented to discuss the principal composition of the components as well as the methods of its realization in the field of reference based NMR diagnostics and tissue characterization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号