首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
This work reports the advantages of using glassy carbon electrodes (GCEs) modified with multi-wall carbon nanotubes (CNT) dispersed in polyethylenimine (PEI) as detectors in flow injection and capillary electrophoresis. The presence of the dispersion of CNT in PEI at the electrode surface allows the highly sensitive and reproducible determination of hydrogen peroxide, different neurotransmitters (dopamine (D) and its metabolite dopac, epinephrine (E), norepinephrine (NE)), phenolic compounds (phenol (P), 3-chlorophenol (3-CP) and 2,3-dichlorophenol (2,3CP)) and herbicides (amitrol). Sensitivities enhancements of 150 and 140 folds compared to GCE were observed for hydrogen peroxide and amitrol, respectively. One of the most remarkable properties of the resulting electrode is the antifouling effect of the CNT/PEI layer. No passivation was observed either for successive additions (30) or continuous flow (for 30 min) of the compounds under investigation, even dopac or phenol. A critical comparison of the amperometric and voltammetric signal of these different analytes at bare- and PEI-modified glassy carbon electrodes and pyrolytic graphite electrodes is also included, demonstrating that the superior performance of CNT is mainly due to their unique electrochemical properties. Glassy carbon electrodes modified with CNT-PEI dispersion also show an excellent performance as amperometric detector in the electrophoretic separation of phenolic compounds and neurotransmitters making possible highly sensitive and reproducible determinations.  相似文献   

2.
We report on direct electron transfer reactions of bilirubin oxidase at multi-walled carbon nanotube (MWCNT) modified glassy carbon electrodes (GCE). The bioelectrocatalytic oxygen reduction was recorded using linear sweep voltammetry (LSV) with BOD in solution, adsorbed and covalently linked to the nanotubes. The MWCNT modification of GC electrodes strongly enhances the oxygen reduction compared to the signals at unmodified GCE. Under anaerobic conditions with a high protein concentration in solution a pair of redox peaks with a formal potential of 450 ± 15 mV vs Ag/AgCl, 1 M KCl (pH 7.4) was found with cyclic voltammetry. The redox conversion is indicated to be surface-controlled and pH-dependent (54.5 mV/pH). The quasi-reversible redox reaction might be attributed to the trinuclear T2/T3 cluster of BOD.  相似文献   

3.
Electrodes modified with carbon nanomaterials find wide ranging applications in electrochemistry such as in energy generation and storage through to applications in electroanalysis. A substantial limitation is the presence of metallic impurities which vary between batches and can produce erroneous results. Consequently we have explored the electrochemical properties of metallic impurity free carbon nanotube paste electrodes using potassium ferrocyanide and hydrogen peroxide as model compounds. In terms of the latter utilising cyclic voltammetry, a linear range from 0.75 to 3 mM with a limit of detection of 0.19 mM is possible using the electrochemical oxidation of hydrogen peroxide while using the electrochemical reduction of the target analyte, a linear range from 0.5 to 249 mM is possible with a detection limit of 0.43 mM.The ultra-small size of the carbon nanotubes and fabrication methodology result in a tightly bound carbon nanotube electrode surface which does not exhibit thin-layer behaviour resulting in highly reproducible electrodes with the %RSD found to be 5.5%. These analytical ranges, detection limits and reproducibility are technologically useful.The carbon nanotubes utilised are completely free from metallic impurities and do not require lengthy processing to remove impurities and consequently have no variation in the purity of the nanomaterial between batches as is commonly the case for other available carbon nanotube material. The impurity free nature of this nanomaterial allows for highly reproducible and intelligent sensors based on carbon nanotubes to be understood and realised for the first time.  相似文献   

4.
The performance of carbon nanotubes paste electrodes (CNTPE) prepared by dispersion of multi-wall carbon nanotubes (MWNT) within mineral oil is described. The resulting electrode shows an excellent electrocatalytic activity toward ascorbic acid, uric acid, dopamine, 3,4-dihydroxyphenylacetic acid (dopac) and hydrogen peroxide. These properties permit an important decrease in the overvoltage for the oxidation of ascorbic acid (230 mV), uric acid (160 mV) and hydrogen peroxide (300 mV) as well as a dramatic improvement in the reversibility of the redox behavior of dopamine and dopac, in comparison with the classical carbon (graphite) paste electrodes (CPE). The substantial decrease in the overvoltage of the hydrogen peroxide reduction (400 mV) associated with a successful incorporation of glucose oxidase (GOx) into the composite material, allow the development of a highly selective and sensitive glucose biosensor without using any metal, redox mediator or anti-interference membrane. No interference was observed at −0.100 V even for large excess of ascorbic acid, uric acid and acetaminophen. A linear response up to 30 mM (5.40 g l−1) glucose with a detection limit of 0.6 mM (0.11 g l−1) were obtained with the CNTPE modified with 10% w/w GOx. Such an excellent performance of CNTPE toward hydrogen peroxide, represents a very good alternative for developing other enzymatic biosensors.  相似文献   

5.
A highly sensitive method for electrochemical detection of daunorubicin (DNR) was proposed on the carbon nanotubes (CNT) modified electrode. The supramolecular interaction between the CNT and the anthracyclin could significantly enhance the electron transferability, which sharply increased the detection sensitivity and lowered the detection limit. Under the optimized conditions, the linear range of the DNR detection was 20–500 nM with a detection sensitivity of 5.9 nA/nM. The detection of the DNR in the serum samples was also attempted. It can be predicted that many more analogues could be monitored on such a platform with high sensitivity.  相似文献   

6.
In this work, a novel amperometric biosensor based on carbon nanoplatelets derived from ground cherry (Physalis peruviana) husks (GCHs-CNPTs) is reported for the sensitive and selective detection of ascorbic acid (AA). The structure of the nanoplatelets, the oxygen-containing groups and edge-plane-like defective sites (EPDSs) on the GCHs-CNPTs were characterized by scanning electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The presence of GCHs-CNPTs with a high density of EPDSs effectively enhances the electron transfer between AA and the glassy carbon electrode (GCE), and thus induces a substantial decrease in the overvoltage for AA oxidation compared with both a bare GCE and a GCE modified with carbon nanotubes (CNTs/GCE). In particular, an amperometric biosensor based on GCHs-CNPTs exhibited a wider linear range (0.01–3.57 mM), higher sensitivity (208.63 μA mM 1 cm 2), a lower detection limit (1.09 μM, S/N = 3) and better resistance to fouling for AA determination compared to a CNTs/GCE. The great potential of the GCHs-CNPTs/GCE for practical and reliable AA analysis was demonstrated by the successful determination of AA in samples taken from a medical injection dose and a soft drink.  相似文献   

7.
We have characterized symmetric solid-state supercapacitors in swagelok cells using film electrodes made of novel hybrid materials based on multiwalled carbon nanotubes (CNT) and phosphomolybdate polyanion (Cs-PMo12) with PVA as binder. These hybrid materials were carried out by Cs-PMo12 adhesion onto previously functionalized CNT, in order to disperse both components at a molecular level and use Cs-PMo12 as energy density enhancer in supercapacitor cells. Our results show high capacitance values (up to 285 F/g at I = 200 mA/g) due to the contribution of Cs-PMo12, which was revealed on the higher energy density values compared to pure CNT electrodes. Additionally, good stability was observed during 500 charge–discharge cycles for most hybrid electrodes. These preliminary results show a new approach to enhance energy density of double layer supercapacitor cells through the introduction of Cs-PMo12, whereas from a material science point of view these materials are innovative, and open the way to search for diverse applications aside from supercapacitors (sensors, catalysts, photovoltaic cells, etc.).  相似文献   

8.
We report the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multiwall carbon nanotubes (MWCNT) in polylysine (Plys) (GCE/MWCNT‐Plys). The resulting electrodes show an excellent electrocatalytic activity towards different bioanalytes like ascorbic acid, uric acid and hydrogen peroxide, with important decrease in their oxidation overvoltages. The dispersion of 1.0 mg/mL MWCNT in 1.0 mg/mL polylysine is highly stable, since after 2 weeks the sensitivity for hydrogen peroxide at GCE modified with this dispersion remained in a 90% of the original value. The MWCNT‐Plys layer immobilized on glassy carbon electrodes has been also used as a platform to build supramolecular architectures by self‐assembling of polyelectrolytes based on the polycationic nature of the polylysine used to disperse the nanotubes. The self‐assembling of glucose oxidase has allowed us to obtain a supramolecular multistructure for glucose biosensing. The influence of glucose oxidase concentration and adsorption time as well as the effect of using polylysine or MWCNT‐Plys as polycationic layers for further adsorption of GOx is also evaluated.  相似文献   

9.
Platinum nanoparticles/carbon nanotubes (Ptnano/CNTs) were rapidly synthesized by microwave radiation, and applied for the oxidative determination of arsenic(III). The transmission electron microscopy (TEM) revealed the size of synthesized Pt nanoparticles with nominal diameter of 15 ± 3 nm. Ptnano/CNTs modified glassy carbon electrode (Ptnano/CNTs/GCE) exhibited better performance for arsenic(III) analysis than that of Pt nanoparticles modified GCE (Ptnano/GCE) by electrochemical deposition or Pt foil electrode. Excellent reproducibility of the Ptnano/CNTs/GCE was obtained with the relative standard deviation (RSD) of 3.5% at 20 repeated analysis of 40 μM As(III), while the RSD was 9.8% for Ptnano/GCE under the same conditions. The limit of determination (LOD) of the Ptnano/CNTs/GCE was 0.12 ppb, which was 1–2 orders of magnitude lower than that of Ptnano/GCE or Pt foil electrode.  相似文献   

10.
Conducting polymer composite films comprised of polypyrrole (PPy) and multiwalled carbon nanotubes (MWCNTs) [PPy–CNT] were synthesized by in situ polymerization of pyrrole on carbon nanotubes in 0.1 M HCl containing (NH4)S2O8 as oxidizing agent over a temperature range of 0–5 °C. Pt nanoparticles are deposited on PPy–CNT composite films by chemical reduction of H2PtCl6 using HCHO as reducing agent at pH = 11 [Pt/PPy–CNT]. The presence of MWCNTs leads to higher activity, which might be due to the increase of electrochemically accessible surface areas, electronic conductivity and easier charge-transfer at polymer/electrolyte interfaces allowing higher dispersion and utilization of the deposited Pt nanoparticles. A comparative investigation was carried out using Pt–Ru nanoparticles decorated PPy–CNT composites. Cyclic voltammetry demonstrated that the synthesized Pt–Ru/PPy–CNT catalysts exhibited higher catalytic activity for methanol oxidation than Pt/PPy–CNT catalyst. Such kinds of Pt and Pt–Ru particles deposited on PPy–CNT composite polymer films exhibit excellent catalytic activity and stability towards methanol oxidation, which indicates that the composite films is more promising support material for fuel cell applications.  相似文献   

11.
The electrochemical oxidation of β-nicotinamide adenine dinucleotide (NADH) is studied at a glassy carbon electrode (GCE) modified with bicontinuous gyroidal mesoporous carbon (BGMC). Due to the large surface area and remarkable electrocatalytic properties of BGMC, the BGMC/GCE exhibits potent electrocatalytic activity toward the electro-oxidation of NADH. A substantial decrease of 649 mV in the overpotential of NADH oxidation reaction is achieved compared with a bare GCE. The anodic peak currents increase steadily with the concentration of NADH in a broad range from 3.0 × 10?6 to 1.4 × 10?3 M with a low detection limit of 1.0 × 10?6 M under the optimal condition.  相似文献   

12.
This work reports on a comparative study of the electrochemical performance of carbon nanotubes-based electrodes in micellar media and their application for amperometric detection in micellar electrokinetic capillary chromatography (MEKC) separations. These electrodes were prepared in two different ways: immobilization of a layer of carbon nanotubes dispersed in polyethylenimine (PEI), ethanol or Nafion onto glassy carbon electrodes or preparation of paste electrodes using mineral oil as binder. Scanning electron microscopy (SEM) was employed for surface morphology characterization while cyclic voltammetry of background electrolyte was used for capacitance estimation. The amperometric responses to hydrogen peroxide, amitrol, diuron and 2,3-diclorophenol (2,3CP) in the presence and in the absence of sodium dodecylsulphate (SDS) were studied by flow injection analysis (FIA), demonstrating that the electrocatalytic activity, background current and electroanalytical performance were strongly dependent on the electrodes preparation procedure. Glassy carbon electrodes modified with carbon nanotubes dispersed in PEI (GC/(CNT/PEI)) displayed the most adequate performance in micellar media, maintaining good electrocatalytic properties combined with acceptable background currents and resistance to passivation. The advantages of using GC/(CNT/PEI) as detectors in capillary electrophoresis were illustrated for the MEKC separations of phenolic pollutants (phenol, 3-chlorophenol, 2,3-dichlorophenol and 4-nitrophenol) and herbicides (amitrol, asulam, diuron, fenuron, monuron and chlortoluron).  相似文献   

13.
Single-walled carbon nanohorn (SWCNH) paste electrode was used for amperometric determination of concentrated hydrogen peroxide, and was compared with other carbon electrodes. The calibration plots are linear from 0.5 to 100 mM at activated SWCNH paste electrode and edge plane graphite (EPG) electrode. In contrast, the calibration plots are linear only at concentrations lower than 45 mM at graphite paste electrode, multi-walled carbon nanotube paste electrode, and glassy carbon electrode. Our results show that SWCNH paste electrode and EPG electrode are interesting alternatives to high surface area platinum electrode for determination of concentrated hydrogen peroxide. Because of its high-purity, metal-free SWCNH is a user-friendly and attractive material for electrochemical study.  相似文献   

14.
Copper ion has been reported to be a major interference in the electrochemical detection of arsenic (III) ion in water. Therefore the development of a simple approach to alleviate this interference challenge is important. We present the use of ammonia solution as a masking agent for Cu(II) interference in the square wave anodic stripping voltammetry of As(III) on a gold nanoparticle modified glassy carbon electrode (GCE). AuNPs were electrochemically deposited by cyclic voltammetry on a GCE from a potential range of − 400 mV to 1100 mV for 10 cycles. Square wave anodic stripping voltammetry (SWASV) was used to detect As(III) in water with and without Cu(II) based on the following optimised conditions: pH = 3, deposition potential =  600 mV, and deposition time = 60 s. Ammonia solution was added to the analyte solution and the effect on mitigating copper interference was studied. The presence of ammonia complexed the Cu(II) ion thereby excluding Cu(II) from interfering with the As(III) signal.  相似文献   

15.
We report a microtubular gas diffusion electrodes made of multi-walled carbon nanotubes (MWCNT). The electrodes were prepared by inside-out cake filtration of an aqueous MWCNT suspension onto a microfiltration hollow fiber (HF) membrane, followed by washing out the surfactant, drying and removal of the all CNT microtube from the HF membrane. Length, outer diameter, and wall thickness of the tubular electrodes are: up to 44 cm, ~ 1.7 mm and 275 μm, respectively. The BET surface area is 200 m2/g with a porosity of 48–67% and an electrical conductivity of ~ 20 S/cm. Application of this microtubular Gas Diffusion Electrodes (GDE) was studied for the oxygen reduction reaction (ORR) in divided and undivided electrochemical cells. Oxygen supply into the lumen of the tubular electrodes resulted in much higher current densities for ORR than in experiments where the electrolyte was saturated by bubbling with pure oxygen. Within the 0.25–1.0 bar pressure (gauge) region, higher ORR rates were achieved at lower pressure. We also show that H2O2 production is possible using the new GDE. We propose to use such novel electrodes for the fabrication of tubular electrochemical reactors, e.g. fuel cells, H2O2 generators, CO2 reduction and other processes that involve GDE application.  相似文献   

16.
Glassy carbon electrodes (GCE) modified with carbon nanotubes (CNT) have been created for detection of phenolic compounds—one of the important group of antioxidants in life sciences. The surface of electrode has been characterized by atomic force microscopy. The presence of CNT leads to an at least 20-fold increase in the surface roughness of the electrode. The CNT layer displays closely intertwined vermicular structures with high degree of homogeneity at CNT suspension concentration of 0.2–0.5 mg L−1. Synthetic water-soluble antioxidants (hydroquinone, catechol, pyrogallol, and their derivatives) are electrochemically active on bare GCE and CNT-modified GCE in phosphate buffer solution pH 7.4. Effect of substitutes in molecular structure of phenolic antioxidants has been evaluated. In several cases, oxidation at CNT-modified GCE occurs at potentials that are less positive by 100–200 mV in comparison to bare GCE. The electrodes were studied with respect to their capability of phenols voltammetric sensing. CNT-modified GCE display an enlarged linear range in the calibration graphs and lower detection limits. Voltammetric method for determination of hydroquinone, catechol, pyrogallol, and their derivatives has been developed.  相似文献   

17.
The electrochemiluminescent (ECL) behavior of lucigenin on a multi-wall carbon nanotube/nano-Au modified glassy carbon electrode (MWNT/nano-Au/GCE) was studied in this paper. Compared with the bare GCE, the ECL intensity of lucigenin can be greatly enhanced at MWNT/nano-Au/GCE. Based on the fact that superoxide dimutase (SOD) could obviously inhibit the ECL of lucigenin at MWNT/nano-Au/GCE, a sensitive ECL biosensor for determination of SOD was developed with a wide linear range of 5.0 × 10−8–5.0 × 10−6 mol/L with detection limit of 2.5 × 10−8 mol/L.  相似文献   

18.
The direct electron transfer reaction of fructose dehydrogenase (FDH) from Gluconobacter sp. on alkanethiol-modified gold nanoparticles (AuNPs) was examined. AuNP-modified electrodes were simply fabricated by depositing citrate-reduced gold nanoparticles onto a gold electrode and carbon fiber paper and then covering the surface with a self-assembled monolayer of alkanethiols. The immobilization of AuNPs provided a large effective surface area for the adsorption of FDH. Catalytic oxidation currents based on the direct electron transfer reaction of FDH were observed from a potential about ?100 mV (vs. Ag/AgCl, 3 M NaCl) in the presence of d-fructose without a mediator. The current density reached as high as 14.3 ± 0.93 mA/cm2 (at +500 mV), which was achieved in the presence of 200 mM d-fructose by immobilization of FDH on 2-mercaptoethanol-modified AuNP/carbon fiber paper electrodes.  相似文献   

19.
Tungsten-containing formate dehydrogenase from Methylobacterium extorquens AM1 (FoDH1) catalyzes formate oxidation with NAD+. FoDH1 shows little direct communication with carbon electrodes, including mesoporous Ketjen Black-modified glassy carbon electrode (KB/GCE); however, it shows well-defined direct electron transfer (DET)-type bioelectrocatalysis of carbon dioxide reduction, formate oxidation, NAD+ reduction, and NADH oxidation on gold nanoparticle (AuNP)-embedded KB/GCE treated with 4-mercaptopyridine. Microscopic measurements reveal that the AuNPs (d = 5 nm) embedded on the KB surface are uniformly dispersed. Electrochemical data indicate that the pyridine moiety on the AuNPs plays important roles in facilitating the interfacial electron transfer kinetics and increasing the probability of productive orientation of FoDH1. The formal potential of the electrochemical communication site, which is most probably an ion‑sulfur cluster, is evaluated as − 0.591 ± 0.005 V vs. Ag | AgCl | sat. KCl from Nernst analysis of the steady-state catalytic waves.  相似文献   

20.
Amperometric biosensing of glutamate using nanobiocomposite derived from multiwall carbon nanotube (CNT), biopolymer chitosan (CHIT), redox mediator meldola’s blue (MDB) and glutamate dehydrogenase (GlDH) is described. The CNT composite electrode shows a reversible voltammetric response for the redox reaction of MDB at −0.15 V; the composite electrode efficiently mediates the oxidation of NADH at −0.07 V, which is 630 mV less positive than that on an unmodified glassy carbon (GC) electrode. The CNTs in the composite electrode facilitates the mediated electron transfer for the oxidation of NADH. The CNT composite electrode is highly sensitive (5.9 ± 1.52 nA/μM) towards NADH and it could detect as low as 0.5 μM of NADH in neutral pH. The CNT composite electrode is highly stable and does not undergo deactivation by the oxidation products. The electrode does not suffer from the interference due to other anionic electroactive compounds such as ascorbate (AA) and urate (UA). Separate voltammetric peaks have been observed for NADH, AA and UA, allowing the individual or simultaneous determination of these bioanalytes. The glutamate biosensor was developed by combining the electrocatalytic activity of the composite film and GlDH. The enzymatically generated NADH was electrocatalytically detected using the biocomposite electrode. Glutamate has been successfully detected at −0.1 V without any interference. The biosensor is highly sensitive, stable and shows linear response. The sensitivity and the limit of detection of the biosensor was 0.71 ± 0.08 nA/μM and 2 μM, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号