首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A direct immersion solid-phase microextraction coupled with gas chromatography-electron capture detection (SPME-GC-ECD) method was optimized and validated for the quantitative determination of 18 organochlorine pesticides in ground water. Ionic strength, stirring speed, adsorption and desorption time and pH were some of the parameters investigated in order to select the optimum conditions for SPME with a 50/30 DVB/CAR/PDMS fiber coating. The SPME-GC/ECD method showed good linear response below 10 ng L−1 with R2 values in the range of 0.9950–0.9997. The repeatability of the measurements were lower than 10%. Values of relative recoveries located within the acceptable range (80–120%). Limits of quantification (LOQ) from 4.5 × 10−3 to 1.5 ng L−1 were obtained. On average 8 organochlorines were found per sample, even so all the 18 organochlorines were quantified among them. Substances such as endrin ketone, γ-BHC and β-BHC were the pesticides determined in larger concentration (0.06–305 ng L−1), while methoxychlor and aldrin in smaller amounts (0.151–1.55 ng L−1). Measured levels of organochlorine pesticides were above the limits established by Brazilian regulations.  相似文献   

2.
A solid-phase microextraction technique using steel fiber coated with 20 μm polypyrrole (Ppy) doped with polyphosphate was developed for the GC determination of a group of organochlorine pesticides (OCPs) in water. The coating was prepared using a three-electrode electrochemical system from a 10% aqueous sodium polyphosphate solution containing 0.05 M pyrrole by applying a constant potential of 1.2 V for 30 min. In order to obtain an adherent, smooth and stable film of polypyrrole, experimental parameters related to the coating process consisting of the type of dopant or counter-ion, deposition potential, concentration of the monomer, concentration of the counter-ion, and deposition time were optimized. The effects of various parameters on the efficiency of SPME process such as extraction time, extraction temperature, ionic strength, desorption time, and desorption temperature were also studied. The coating was highly stable and extremely adherent to the surface of the steel fiber. The method was linear for at least three orders of magnitude with correlation coefficients varying from 0.9818 to 0.9977. The accuracies found through spiking blank samples showed high recoveries between 82 and 110%. Intra- and inter-day precisions of the method were determined from mixed aqueous solutions containing 1.0 ng ml−1 of each OCP. The intra-day precisions varied from 4.7% for heptachlor to 11.4% for methoxychlor, while the inter-day precisions varied from 6.8% for endosulfan I to 13.0% for p,p′-DDD and o,p-DDD. Limits of detection based on S/N = 3 were in the range 0.015-0.66 pg ml−1. The proposed method was applied to monitor organochlorine pesticides in some well water samples.  相似文献   

3.
A rapid, sensitive, convenient, and highly quality-assured method is presented for the determination of 19 organochlorine pesticides (OCPs) in small samples (10 ml) of ground water. Samples are initially fortified with 2,4,5,6-tetrachloro-m-xylene (surrogate) and decachlorobiphenyl (retention time marker), then extracted with a 30-micron thickness polydimethylsiloxane solid-phase microextraction fiber. The analytes collected are thermally desorbed in a heated gas chromatographic inlet, separated using independent fused-silica capillary columns ("primary" and "confirmatory"), and detected using electron-capture detection. Two independent statistical procedures were used to evaluate the detection limits, which typically range between 10 and 40 ng l-1, for these analytes. Method performance was also evaluated using two additional protocols employing "performance evaluation" samples, in which authentic ground water samples were fortified to ca. 100 ng l-1 in each of at least six OCPs. The method satisfies additional strict criteria based on uniformity of fiber performance and minimal degradation of the thermally-sensitive analytes endrin and DDT.  相似文献   

4.
This paper describes the extraction of 20 organochlorine pesticides (OCPs) from water samples using solid-phase microextraction (SPME). Three fused-silica fibers coated or bonded with polydimethylsiloxane (PDMS) of different film thicknesses (20-, 30-, and 100-μm) were evaluated. The extraction time, the effects of stirring and addition of NaCl to the aqueous sample, the linear range and the precision of this technique, and the effect of carryover were examined for 20 analytes and are presented here. A comparison with results using conventional liquid-liquid extraction demonstrate that the SPME technique is well suited as a fast screening technique for OCPs in water samples.  相似文献   

5.
The study on the performance of polyaniline as a fiber coating for solid-phase microextraction (SPME) purposes has been reported. Polyaniline coatings were directly electrodeposited on the surface of a stainless steel wire and applied for the extraction of some organochlorine pesticides (OCPs) from water samples. Analyses were performed using GC-electron capture detection (GC-ECD). The results obtained show that polyaniline fiber coating is suitable for the successful extraction of organochlorine compounds. This behavior is most probably due to the porous surface structure of polyaniline film, which provides large surface areas and allowed for high extraction efficiency. Experimental parameters such as adsorption and desorption conditions were studied and optimized. The optimized method has an acceptable linearity, with a concentration range of 1-5000 ng/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 12 and 17%, respectively. High environmental resistance and lower cost are among the advantages of polyaniline fibers over commercially available SPME fibers. The developed method was applied to the analysis of real water samples from Yangtse River and Tianmu Lake.  相似文献   

6.
Simultaneous determination of pyrethroid, organophosphate (OP) and organochlorine (OC) pesticides in water was achieved with headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-electron-capture detection (GC-ECD). The parameters affecting HS-SPME of pesticides from water were optimized, including extraction temperature, sample and headspace volumes, and sodium chloride amounts. The effects of desorption temperature, desorption time, and position of the fibre in the GC inlet were also investigated. Extraction temperature was the most important factor affecting the recoveries of analytes, and the optimized temperature was 96°C. The addition of salt did not increase extraction efficiencies of the pesticides from the water. The optimized desorption conditions in the GC were as follows: desorption time of 10?min; desorption temperature of 260°C; and a 2?cm position of the fibre in the inlet. The method detection limits were in the low-ng/L level with a linearity range of 50–1000?ng/L for the OCs, 50–5000?ng/L for the OP, and 50–20?000?ng/L for the pyrethroids. These data demonstrated that HS-SPME is a sensitive method for the determination of pyrethroid, OC, and OP pesticides in water.  相似文献   

7.
A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography–electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g−1, and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.   相似文献   

8.
In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography–mass spectrometry (GC–MS), the fiber exhibited wide linearity (2–500 ng L−1) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059–0.151 ng L−1) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME–GC–MS method.  相似文献   

9.
Summary A study of different extraction techniques for the determination of a selected group of organochlorine compounds in surface waters is presented. Comparison of liquid-liquid extraction (LLE) with solid-phase extraction (SPE) and solid-phase microextraction (SPME) with fibers of different polarity shows that SPME with a recently commercialised fiber of polydimethylsiloxane divinylbenzene allows these compounds to be determined in surface waters with good extraction efficiencies. Extraction time, effect of temperature, ionic strength and pH were optimised, allowing quantification in agricultural effluents in the range 1.0–60 ng·L−1.  相似文献   

10.
A coupled technique, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), was investigated for one-step in situ sample pretreatment for organochlorine pesticides (OCPs) prior to gas chromatographic determination. The OCPs, aldrin, o,p'-DDE, p,p'-DDE, o,p'-DDT, p,p'-DDT, dieldrin, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, endrin, delta-HCH, gamma-HCH, heptachlor, heptachlor epoxide, methoxychlor and trifluralin were collected by the proposed method and analyzed by gas chromatography with electron-capture detection (GC-ECD). To perform the MA-HS-SPME, six types of SPME fibers were examined and compared. The parameters affecting the efficiency in MA-HS-SPME process such as sampling time and temperature, microwave irradiation power, desorption temperature and time were studied to obtain the optimal conditions. The method was developed using spiked water samples such as field water and with 0.05% humic acid in a concentration range of 0.05-2.5 microg/l except endosulfan sulfate in 0.25-2.5 microg/l. The detection was linear over the studied concentration range with r2>0.9978. The detection limits varied from 0.002 to 0.070 microg/l based on S/N=3 and the relative standard deviations for repeatability were <15%. A certified reference sample of OCPs in aqueous solution was analyzed by the proposed method and compared with the conventional liquid-liquid extraction procedure. These results are in good agreement. The results indicate that the proposed method provides a very simple, fast, and solvent-free procedure to achieve sample pretreatment prior to the trace-level screening determination of organochloride pesticides by gas chromatography.  相似文献   

11.
Gao Z  Li W  Liu B  Liang F  He H  Yang S  Sun C 《Journal of chromatography. A》2011,1218(37):6285-6291
A novel nano-structured polyaniline-ionic liquid (i.e. 1-butyl-3-methylimidazolium hexafluorophosphate, BMIPF(6)) composite (BPAN) film coated steel wire was prepared by electrochemical deposition. Scanning electron microscopy images showed that the obtained porous BPAN coating consisted of nanofibers, whose diameter ranged from 50 to 80 nm. Furthermore, the novel nano-structured composite coating was very stable at relatively high temperatures (up to 350 °C) and it could be used for more 250 times without obvious decrease of the extraction efficiency. The novel BPAN coating was used for the headspace solid-phase microextraction (HS-SPME) of organochlorine pesticides (i.e. hexachlorocyolohexane, dichlorodiphenyldichloroethylene, dichlorodiphenyldichloroethane, dichlorodiphenyltrichloroethane), coupled with gas chromatography-electron capture detection (GC-ECD). The BPAN coating showed better analytical capability on the whole compared with common polyaniline (PANI) and polydimethylsiloxane (PDMS) coatings. The key parameters influencing extraction efficiency were investigated and optimized, including desorption time, stirring speed, extraction temperature, extraction time and ionic strength. The relative standard deviations (RSDs) for single fiber repeatability ranged from 2.3 to 8.7% (n=6) and the RSDs for fiber-to-fiber reproducibility (n=6) were 4.2-12.1%, respectively. The linear ranges exceeded three magnitudes with correlation coefficients above 0.99. The detection limits were 0.12-0.31 ng L(-1). The proposed method was successfully applied for the determination of organochlorine pesticides in lake water, waste water and sewage treatment plant effluent with good recoveries from 88.9 to 112.9%.  相似文献   

12.
烟草中有机氯类农药多残留分析前处理方法对比研究   总被引:1,自引:0,他引:1  
以烟草中有机氯类农药为研究对象,从检出限、回收率、重复性和色谱图4个方面系统比较了机械振荡萃取法、超声波溶剂萃取法、微波辅助萃取法和加速溶剂萃取法4种常用前处理方法。由于加速溶剂萃取法是在高温高压下进行萃取,在提取出残留农药的同时,也提取出更多的干扰物。机械振荡法、超声波溶剂萃取法和微波辅助萃取法各项结果差别较小,其中机械振荡萃取法回收率和重复性最好,但提取时间较长。考虑溶剂消耗和提取时间等方面的因素,微波辅助萃取是较理想的样品前处理方法。  相似文献   

13.
The feasibility of single-walled carbon nanotubes (SWCNTs) as adsorbents for solid-phase microextraction was investigated by using organochlorine pesticides (OCPs) as model compounds. SWCNTs were attached onto a stainless steel wire through organic binder. Potential factors affecting the extraction efficiency were optimized, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity. The developed method has a linear range of 2-800 ng/L for most analytes, with coefficients of correlation ranging from 0.9911 to 0.9996, LODs ranged from 0.19 to 3.77 ng/L (S/N = 3), and RSDs in the range of 3.5-13.9% (n = 5). Compared with the commercial PDMS fiber, the SWCNT fiber has better thermal stability (over 350 degrees C) and longer life span (over 150 times). The developed method was applied to determine trace OCPs in lake water and wastewater samples with external standard calibration. Results showed that OCP contamination was very low in these samples, and HCHs were detected in almost all water samples while DDT concentrations were almost under detection limits in these samples. Recoveries obtained at 20 ng/L spiking level were in the range of 88.4-111% for OCPs in lake water. For wastewater samples, however, the recoveries were satisfactory for HCHs (63.6-97.1%) but relatively low for DDTs (44.7-116%) due to the high content of organic matter in wastewater.  相似文献   

14.
A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-μm polydimethylsiloxane–divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-μm PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.  相似文献   

15.
Polyphenylmethylsiloxane (PPMS) as a novel coating for solid-phase microextraction (SPME) combined with microwave-assisted extraction (MAE) has been applied to determine the concentrations of organochlorine pesticides (OCPs) in Chinese teas. The characteristics of PPMS fiber, the extraction modes of SPME, the extraction time, temperature, and salt effects were investigated. Microwave irradiation time and power were also studied. Compared with commercial polydimethylsiloxane (PDMS) fiber and homemade sol-gel polymethylsiloxane (PMS) fiber, the novel porous sol-gel PPMS fiber exhibited high sensitivity and selectivity for OCPs compounds, higher thermal stability (to 350 degrees C) and long service life (more than 150 times). The recoveries of MAE is compared with that of ultrasonic extraction (USE), MAE-SPME-gas chromatography (GC)/electron-capture detection (ECD) methods showed better results for Chinese teas. Linear ranges of OCPs in the blank green tea was 0.1-10(3) ng/l. Detection limits of this method are below 0.081 ng/l. Recoveries of this method are between 39.05 and 94.35%. The repeatability of the technique was less than 16% relative standard deviation (R.S.D.). The tested pesticides in three Chinese teas were at the ng/g level.  相似文献   

16.
Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been applied to determine six phthalate esters and one adipate ester in water. The SPME parameters were optimized for several commercially available fibers. A 65-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) was the fiber selected and was applied to analysis of water from the Ebro river and the industrial port of Tarragona. The studied compounds were found at concentrations ranging from 0.4 microg l(-1) for di-n-butyl phthalate ester (DnBP) to 3.2 microg l(-1) for bis(2-ethylhexyl) phthalate ester (DEHP). The linear range for real samples was from 0.1 to 10 microg l(-1) for most phthalates, and the limits of detection of the method were between 3 and 30 ng l(-1). Repeatability and reproducibility between days (n = 5) for 1 microg l(-1) samples were below 13 and 18%, respectively.  相似文献   

17.
A novel extraction procedure coupled with gas chromatography-mass spectrometric detection for quantification of organochlorine pesticides (OCPs) in water is described. Amphiphilic polyhydroxylated polyparaphenylene (PH-PPP) was synthesized and coated on the surfaces of a porous polypropylene hollow fiber membrane (HFM). Due to the high porosity of the HFM, maximum active surface area to achieve high extraction efficiency is expected. The polymer-coated HFM was used for the extraction of 15 OCPs from water. The extraction efficiency was compared with emerging and established methods such as liquid-phase microextraction (LPME), solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) techniques. We term the current procedure as polymer-coated hollow fiber microextraction (PC-HFME). PC-HFME showed good selectivity and sensitivity. Detection limits for OCPs were in the range of 0.001-0.008 microg l(-1). The sensitivity and selectivity of the coated HFM could be adjusted by changing the characteristics of the coated PH-PPP film.  相似文献   

18.
Abstract

A sequential injection analysis method for the simultaneous spectrophotometric determination of phosphate and silicate has been developed. The method is based on the different reaction rates of the heteropolymolybdate formation reactions. Concentrations within the range 0.026—0.485 mmol P l?1 and 0.125—2.848 mmol Si l?1 have been determined at a frequency of 30 samples per hour. An R.S.D. of 2.1% was obtained for 0.162 mmol P l?1 and of 1.1% for 1.424 mmol Si l?1. The method was found to be suitable for the determination of phosphate and silicate in wastewater.  相似文献   

19.
We developed a simple and efficient headspace liquid-phase microextraction (LPME) technique named dynamic hook-type liquid-phase microextraction (DHT-LPME) and used it in combination with gas chromatography-mass spectrometry (GC-MS) and an electron capture detector (ECD). Aqueous specimens of organochlorine pesticides (OCPs) were used as model compounds to demonstrate the effectiveness of the technique. In the present study, the calibration curves were linear over at least 2 orders of magnitude with R2 values of 0.997. The method detection limits (MDLs) varied from 2 to 44.0 ng L−1. The precision of DHT-LPME ranged from 6.5 to 14.4%. The relative recoveries of OCPs in rainwater were more than 84.2%. Enrichment factors (EF) in the range 275-1127 were obtained using DHT-LPME.  相似文献   

20.
An analytical procedure was developed using headspace solid-phase microextraction (HS-SPME) for the determination of organochlorine pesticides (OCPs) and their metabolites in sandy soil samples. The developed procedures involving fiber selection, temperature effect, absorption time, soil matrix and the addition of solvents of different polarity were optimized. Also, the results were compared to those achieved using Soxhlet extraction standard method. The 100-microm polydimethylsiloxane (PDMS) and 65-microm PDMS-divinylbenzene showed good extraction efficiency for 18 organochlorine pesticides. An increase in the extraction efficiency of organochlorine pesticides and the metabolites was observed when the temperature increased, and an optimum temperature of 70 degrees C for extracting OCPs was obtained. The application of other hydrophilic solvents had different effects on the extraction of organochlorine pesticides and the metabolites. Higher responses of OCPs were obtained when 5 ml of water was added to the soil. Good linearity of OCPs between 0.2 and 4 ng/g soil was observed. The relative standard deviation was found to be lower than 25%. Also the limits of detection were between 0.06 and 0.65 ng/g, which were lower than those obtained using Soxhlet extraction. Moreover, the optimized HS-SPME procedure was applied to the analysis of OCPs in certified reference material (CRM) 804-050 soil and compared with Soxhlet extraction procedure. Results obtained in this study were in good agreement with those obtained using Soxhlet extraction. The mean values obtained using HS-SPME technique were in the range of 16.5 to 1459.6 mg/kg, which corresponds to the recoveries of 68% to 127% of the certified values of CRM soil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号