首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shaikh  M.  Desai  S. S.  Patra  A. K. 《Pramana》2004,63(2):465-470
Pramana - A two-dimensional position sensitive neutron detector has been developed. The detector is a3He + Kr filled multiwire proportional counter with charge division position readout and has a...  相似文献   

2.
With new generation neutron sources, traditional neutron detectors cannot satisfy the demands of the applications, especially under high flux. Furthermore, facing the global crisis in ~3He gas supply, research on new types of neutron detector as an alternative to ~3He is a research hotspot in the field of particle detection. GEM(Gaseous Electron Multiplier) neutron detectors have high counting rate, good spatial and time resolution, and could be one future direction of the development of neutron detectors. In this paper, the physical process of neutron detection is simulated with Geant 4 code, studying the relations between thermal conversion efficiency, boron thickness and number of boron layers. Due to the special characteristics of neutron detection, we have developed a novel type of special ceramic n THGEM(neutron THick GEM) for neutron detection. The performance of the n THGEM working in different Ar/CO_2 mixtures is presented, including measurements of the gain and the count rate plateau using a copper target X-ray source. A detector with a single n THGEM has been tested for 2-D imaging using a ~(252)Cf neutron source. The key parameters of the performance of the n THGEM detector have been obtained, providing necessary experimental data as a reference for further research on this detector.  相似文献   

3.
The BESⅢ RPC with Gd coating as thermal neutron detector was designed and constructed. Three prototypes were built with different techniques of producing the gadolinium converter. The performance of the cosmic ray test, the signal and the radiation spectrum were discussed in this paper. Lastly, the efficiency of one prototype with the best performance for detecting the thermal neutron was tested as 8.7%.  相似文献   

4.
The BESⅢ ·RPC with Gd coating as thermal neutron detector was designed and constructed. Three prototypes were built with different techniques of producing the gadolinium converter. The performance of the cosmic ray test, the signal and the radiation spectrum were discussed in this paper. Lastly, the efficiency of one prototype with the best performance for detecting the thermal neutron was tested as 8.7%.  相似文献   

5.
A new thermal neutron detector with a domestically produced THGEM (Thick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for neutron detection. A detector prototype has been developed and the preliminary experimental tests are presented, including the performance of the Au-coated THGEM working in Ar/CO2 gas mixtures and the neutron imaging test with 252Cf source, which can provide the reference for experimental data for research in the future.  相似文献   

6.
7.
A technique to separate out the dose, and lineal energy spectra of neutrons and charged particles is described. It is based on using two proportional counters, one with a wall, and the other with similar characteristics but wall made from a non-hydrogen containing material. Results of a calibration in a neutron field are also shown.  相似文献   

8.
基于10B薄膜的二维灵敏探测器是新近发展起来的热中子探测器,其灵敏面积大,时间和位置分辨好,n/抑制能力高,抗辐射能力强,可二维读出且具有良好的耐计数能力。针对新型的涂硼灵敏热中子多丝正比(MWPC)探测器,在延迟线时间差方法的基础上,提出一种中子击中位置数字信息的读出方法,并设计NIM读出插件用以验证该方法对于二维中子探测位置信息的读出能力。测试结果表明,本方法能完成4通道探测器信号的实时测量,其时间测量精度好于50 ps。结合FPGA片上系统实时数据控制和处理技术,单插件可支持最高1.3MHz的探测计数率。  相似文献   

9.
以SiC二极管和中子转换材料6LiF为基础,研制了SiC基中子探测器,并用241Am源与临界装置分别研究了SiC基中子探测器的粒子响应、热中子响应。结果表明:SiC基中子探测器能够满足241Am源粒子的计数测量,但由于SiC二极管灵敏区薄,故不能用于5.48 MeV的粒子能谱测量;SiC基中子探测器对热中子响应良好,不同功率下,脉冲幅度谱中可清晰看到由6Li(n,)3H的反应产物粒子、3H粒子形成的双峰;脉冲幅度甄别法可将射线及电子学噪声甄别掉;在直接测量与符合测量中,SiC基中子探测器的计数率均与临界装置功率成线性关系,且直接测量的线性度比符合测量的线性度好,最好可达0.999 97。研究表明:降低肖特基接触金属的厚度、增加其外延层厚度、提高其外延层品质,可将SiC二极管用于带电粒子能谱测量。  相似文献   

10.
介绍了一种用于等离子体焦点装置(DPF装置)中子波形测量的塑料闪烁体探测器,该探测器由ST401型塑料闪烁体、XP2262B型光电倍增管构成。利用银活化中子探测器和DPF装置对该塑料闪烁体探测器进行标定,确定其中子灵敏度为0.022 5 pC每中子,,中子产额测量范围达到109~1011每脉冲,可以满足DPF装置中子参数测量的需要。  相似文献   

11.
用于DPF装置中子测量的闪烁体探测器   总被引:1,自引:1,他引:0       下载免费PDF全文
耿涛 《强激光与粒子束》2007,19(6):1008-1010
 介绍了一种用于等离子体焦点装置(DPF装置)中子波形测量的塑料闪烁体探测器,该探测器由ST401型塑料闪烁体、XP2262B型光电倍增管构成。利用银活化中子探测器和DPF装置对该塑料闪烁体探测器进行标定,确定其中子灵敏度为0.022 5 pC每中子,,中子产额测量范围达到109~1011每脉冲,可以满足DPF装置中子参数测量的需要。  相似文献   

12.
Desai  S. S.  Shaikh  A. M.  Radhakrishna  V.  Rajanna  K. 《Pramana》2004,63(2):471-475
A gas-filled microstrip detector for thermal neutrons has been built and successfully tested in our laboratory. The detector has an active area of 20 mm × 15 mm and consists of alternate anodes and cathodes of widths 12 μm and 300 μm respectively. The anode to cathode gap is 150 μm and the pitch is 612 μm. A high resistance, meandering type horizontal strip connects the anodes at one end and aids in position sensing by charge division method. The detector is tested with gas mixtures3He+Kr (1: 2) and3He+CF4 (2:1) at pressure of 3 atmospheres and using a Pu-Be neutron source. The pulse height spectrum shows energy resolution of ∼8% (FWHM) for the 764 keV peak at anode voltage of 525 V for3He+Kr and ∼15% at anode voltage of 800 V for3He+CF4. Gas gains up to 6.3 × 103 and 3.6 × 103 are obtained respectively with these gas mixtures. The overall efficiency of the detector along the sensitive length is tested by exposing the active area to neutrons and recording the position spectrum. The detector shows fairly uniform efficiency (∼45%) over the active length.  相似文献   

13.
介绍了基于厚型气体电子倍增探测器(THGEM)的位置灵敏热中子探测器中,采用专用集成电路的阵列电荷灵敏前置放大和可编程器件的读出电子学设计。专用集成电路采用VA64TA2,64通道输入电荷灵敏放大成型,触发输出。控制电路使用了现场可编程器件。两者结合,显著减少了读出电路在探测器内所占据的空间。介绍了VA64TA2裸片的封装,给出了电路的原理和时序,进行了线性和电子学噪声试验,结果表明电路具有16 fC的线性动态范围,电子学噪声仅为75个电子电荷。  相似文献   

14.
Kalyani  Tyagi  Mohit  Rawat  Sheetal  Kumar  G Anil 《Pramana》2021,95(4):1-19
Pramana - This work concerns the modelling of the dynamics of polarisation of a centrosymmetric material subjected to an amplitude-modulated excitation (AME). The dynamic equation obtained for the...  相似文献   

15.
The gas-discharge detector is designed for the neutron lifetime spectrometer. The detector is intended for ultracold neutron flux monitoring in measurement cycles at the specrtometer (ILL, Grenoble, France). The detector has been successively tested with a Pu–Be neutron source under laboratory conditions and as a part of the spectrometer.  相似文献   

16.
A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed 241AmBe neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port.  相似文献   

17.
在利用超强激光驱动中子源的研究和应用研究中,中子源的产额及其角分布至关重要.我们在星光Ⅲ号激光装置上采用气泡探测器对强激光驱动的中子源的产额及其角分布进行了测量.利用超强皮秒激光与碳氘薄膜靶相互作用产生高能氘离子束撞击次级碳氘靶,通过氘-氘核反应产生准单能快中子.实验发现中子束的发射具有一定的方向性,在入射氘离子的传输方向上中子束具有更高的强度,测量得到的中子束最大强度为5.13×107 n/sr.利用实验测量的氘离子能谱和角分布对中子束角分布进行了理论计算,结果与实验测量基本一致.  相似文献   

18.
提出了一种在多片Si-PIN探测器中间用2mm厚的聚乙烯作为灵敏度增强介质,采用加法电路模式进行信号输出的组合式新型DT聚变中子(14MeV)探测技术原理. 这种组合的主要特点有: 1)大幅度提高了Si-PIN探测器的中子灵敏度和测量统计性; 2)提高了探测器的n/γ分辨本领; 3)在实现多个探测器信号相加的同时,组合探测器相对于单片探测器时间响应没有明显改变. 从实验及理论上对组合探测器的14MeV中子及1.25MeV γ灵敏度、n/γ分辨,时间特性和测量统计性进行了研究.  相似文献   

19.
双极晶体管经中子辐照后会引起直流增益退化,在109~1016 cm-2的注量范围内,其直流增益倒数变化与辐照中子注量呈线性关系。对直流增益退化的双极晶体管进行高温退火,能使受到辐射损伤的双极晶体管性能恢复。鉴于此,将双极晶体管进行逆向工程应用,制作成中子注量探测器,经标定后,可实现对中子注量的监测。对探测器的装配结构进行设计后,依托中国工程物理研究院快中子脉冲堆(CFBR-Ⅱ),在1012~1013 cm-2的注量范围对3DK2222A型探测器和在1013 cm-2的注量范围对3DG121C型探测器进行标定。在得到探测器损伤常数K的分散性存在较小和较大的两种情况下,确定了分散性较小时的有效取值和应用方法,以及在分散性较大时,采取标定的损伤常数K只能应用在同只探测器上的方案,并通过高温退火实验证实了该方案的可行性。  相似文献   

20.
The investigation of a novel thermal neutron detector is developed to fulfill the requirements of the high intensity power diffractometer (HIPD) at the Chinese Spallation Neutron Source (CSNS). It consists of two layers of 6LiF/ZnS(Ag) scintillators, two layers of crossed WLSF arrays, several multi-anode photo multiplier tubes (MA-PMT), and the matching readout electronics. The neutron detection efficiency of the scintilltors, the light transportation ability of the WLSF, and the spatial linearity of the readout electronics are measured and discussed in this paper. It shows that the sandwich structure and the compact readout electronics could fulfill the needs of the HIPD. A prototype with a 10 cm×10 cm sensitive area has been constructed to further study the characteristics of the neutron scintillator detector.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号