共查询到19条相似文献,搜索用时 62 毫秒
1.
2.
3.
4.
5.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
Pressure oscillations in a sound wave are accompanied by temperature oscillations. In the presence of a solid boundary, the heat transfer from the oscillating gas to the solid boundary causes dissipation of the acoustic energy. This results in the attenuation of the sound wave. This thermal-relaxation dissipation process has a negative effect on the performance of thermoacoustic heat pumps and engines. A simple analytical model describing the interaction between an acoustic wave and a solid boundary is presented. The effect of the solid material and gas type on thermal-relaxation dissipation is analysed. The main result of this model is that the choice of a solid material with the smallest possible heat capacity per unit area in combination with a gas with the largest possible heat capacity per unit area minimises the thermal-relaxation dissipation. From the different combinations solid-gas used in the calculations, the combination cork-helium leads to the lowest thermal attenuation of the sound wave. In this case, the heat transfer from the gas to the wall less damps the temperature oscillations. However, because of the porosity of cork that may cause some problems, it is suggested that the combination polyester-helium can be used in practice to minimise the thermal-relaxation losses. 相似文献
18.
分析了直冷电冰箱单路、双路、多路循环及双机、双级制冷循环,进行了系统匹配性、市场占有率、成本及其COP值比较。针对双路循环存在的频繁开停机现象,提出了完善控制方式及采用双稳态电磁阀的变温技术。变温室蒸发器与冷冻室蒸发器串联,其前串联双稳态电磁阀2,并在变温室蒸发器上并联双稳态电磁阀1,据变温室温度设定改变双稳态电磁阀通断实现两个循环支路交替制冷。冷藏室温度控制压缩机启停,变温室温度仅控制双稳态电磁阀通断,实现切换制冷剂流向目的。应用该循环方式及相关措施研制的BCD-188CH直冷电冰箱最大负荷日耗电0.38度,变温情况下耗电在0.35度以下,最低达0.31度。 相似文献
19.
Thermoacoustic refrigeration is an emerging cooling technology which does not rely for in its operation on the use of any moving parts or harmful refrigerants. This technology uses acoustic waves to pump heat across a temperature gradient. The temperature gradient forms across the ends of a porous body, called the stack, enclosed in a resonator. The vast majority of thermoacoustic refrigerators to date have used electromagnetic loudspeakers to generate the acoustic input. In this paper, the design, construction, operation, and modeling of a piezo-driven thermoacoustic refrigerator are detailed. The performance of the refrigerator is significantly enhanced by coupling the acoustic driver with an elastic structure, referred to as a dynamic magnifier. Proper selection of the magnifier parameters can increase the magnitude of the pressure oscillations across the stack, and consequently the temperature difference. The magnified refrigerator demonstrates the effectiveness of piezoelectric actuation in moving 0.3 W of heat across a 10 °C temperature difference with an input power of 7 W. All the theoretical predictions are validated against data from experimental prototypes. The developed theoretical and experimental tools can serve as invaluable means for the design and testing of piezo-driven thermoacoustic refrigerator configurations. 相似文献