首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.  相似文献   

2.
An improved method for the simultaneous determination of cocaine, norcocaine, benzoylecgonine and benzoylnorecgonine using reversed-phase high-performance liquid chromatography with ultraviolet detection is described. Following solid-phase extraction, chromatography was performed using a column containing an octadecylsilica-coated packing, eluted with 6% acetonitrile in phosphate buffer, pH 2.1, and detected at 233 nm. Using 80-microliters samples, the detection limit is 18 ng/ml for benzoylecgonine and benzoylenorecgonine and 35 ng/ml for cocaine and norcocaine. The coefficients of variation range from 3.5% (benzoylecgonine) to 7.0% (norcocaine). The procedure has been applied to samples of guinea pig plasma, urine and amniotic fluid and human urine.  相似文献   

3.
A method is described for extraction of the cocaine metabolite benzoylecgonine, conversion to the butyl ester derivative and gas chromatographic analysis using packed or capillary columns. Using a capillary column, cocaine and benzoylecgonine may be determined simultaneously. The extraction scheme has been designed to facilitate processing of large numbers of samples generated in pharmacokinetic studies. Structural analogues, m-toluylecgonine and m-toluylecgonine methyl ester, are used as internal standards. Concentrations as low as 10 ng/ml in 1-ml samples of plasma or urine are readily determined. Between-run coefficients of variation were 1.01% for cocaine and 4.18% for benzoylecgonine for concentrations of 75 and 350 ng/ml, respectively.  相似文献   

4.
The application of reversed-phase high-performance liquid chromatography to the measurement of benzoylecgonine and cocaine in urine is described. Following a simple extraction and clean-up procedure, chromatography is performed using a column containing an octadecylsilica coated packing, elution with 17% acetonitrile in pH 2.7 phosphate buffer and ultraviolet detection at 200 or 235 nm. The detection limit is ca.0.1 microgram of drug per ml urine, and using the ethyl ester of benzoylecgonine as an internal standard, benzoylecgonine and cocaine are quantified with coefficients of variation of 7.0 and 2.8%, respectively. The procedure has been applied to urines from subjects receiving intranasal cocaine, and compared to the enzyme multiplied immunoassay technique. The chromatography procedure also permits the separation of norcocaine and benzoylnorecgonine.  相似文献   

5.
The sensitivity achieved by the described thin-layer chromatographic (TLC) method greatly exceeds that of previously published TLC methods for the determination of cocaine and its principal metabolite, benzoylecgonine, in urine. Sensitivity for cocaine and benzoylecgonine approaches 0.1 and 0.25 mug/ml, respectively, for a 5.0-ml specimen. A simple extraction with a mixed organic solvent provides the basic mechanism for isolating the drugs from biologic specimens. Cocaine and its metabolites are stable in sulfuric acid solutions but labile in aqueous media containing certain other inorganic and organic acids; therefore, an emphasis on the utilization of sulfuric acid solutions is employed throughout the procedure. An evaluation of sensitivities achieved for cocaine and benzoylecgonine by various detection reagents is presented. The technique is applicable to drug screening programs.  相似文献   

6.
A simple and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) method is described for the detection of anabolic steroids, usually found in keratin matrix at very low concentrations. Hair samples from seven athletes who spontaneously reported their abuse of anabolic steroids, and in a single case cocaine, were analyzed for methyltestosterone, nandrolone, boldenone, fluoxymesterolone, cocaine and its metabolite benzoylecgonine. Anabolic steroids were determinate by digestion of hair samples in 1 m NaOH for 15 min at 95 degrees C. After cooling, samples were purificated by solid-phase and liquid-liquid extraction, then anabolic steroids were converted to their trimethylsilyl derivative and finally analyzed by GC/MS/MS. For detection of cocaine and benzoylecgonine, hair samples were extracted with methanol in an ultrasonic bath for 2 h at 56 degrees C then overnight in a thermostatic bath at the same temperature. After the incubation, methanol was evaporated to dryness, and benzoylecgonine was converted to its trimethylsilyl derivative prior of GC/MS/MS analysis. Results obtained are in agreement with the athletes' reports, confirming that hair is a valid biological matrix to establish long-term intake of drugs.  相似文献   

7.
The stability of cocaine and its two main human metabolites, benzoylecgonine and ecgonine methyl ester, in chlorine-containing waters has been investigated by direct injection of different reaction time aliquots in a liquid chromatograph (LC) coupled to a quadrupole-time-of-flight mass spectrometer (QTOF-MS). Factors potentially affecting cocaine degradation (the only compound showing a significant decrease in the preliminary study) were evaluated in detail by means of a Box–Behnken experimental design. Sample pH resulted to be the most important variable, increasing both the rate of chlorination-mediated reactions and the ester hydrolysis process. From these reactions, and due to the high mass accuracy measurements obtained with the QTOF system, four by-products could be positively identified: benzoylecgonine, norcocaine, norbenzoylecgonine and N-formylnorcocaine. Finally, their formation and cocaine degradation yields were assessed under chlorination experiments with two real surface water samples. In one of them, showing a low anthropogenic impact, benzoylecgonine and norcocaine were notably generated even after only 1?h of reaction, whereas at higher contact times also norbenzoylecgonine and N-formylnorcocaine could be determined with a lower yield. On the other hand, the second sample, with a higher organic matter content, consumed rapidly the chlorine, so that only benzoylecgonine was produced. These findings point out the convenience of monitoring the described transformation products, in addition to the precursor illicit drug, during drinking water production, taking into account that cocaine traces might be present in water catchments and particularly in areas with high population densities.  相似文献   

8.
Cocaine is a well-known drug of abuse which, when ingested nasally or by smoking, undergoes a number of biotransformation and degradation reactions. In the present work, a synthetic analogue of the cocaine metabolite benzoylecgonine was prepared and used as a template molecule in the preparation of a series of molecularly imprinted polymers (MIPs). Molecularly imprinted solid-phase extraction (MISPE) conditions were established under which benzoylecgonine in aqueous samples could be selectively extracted and quantified at clinically relevant concentrations (μg/ml). Under optimised MISPE conditions, recoveries of analyte were high (>70%) and excellent discrimination between imprinted and non-imprinted materials observed.  相似文献   

9.
A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories).  相似文献   

10.
A solid‐phase extraction and liquid chromatography‐tandem mass spectrometry (SPE/LC‐MS‐MS) method was developed and validated for the simultaneous determination of nicotine, five drugs of abuse (morphine, cocaine, codeine, methadone, and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine) and four metabolites (dihydrocodeine, 6‐acetylmorphine, 11‐nor‐carboxy‐Δ9‐tetrahydrocannabinol, and benzoylecgonine) in water samples. A Fused‐Core? particle column was used as an alternative to sub‐2‐μm particles in chromatographic separations to work with low backpressures and high efficiencies in short analysis times. Drugs were extracted from waste and surface water with SPE using Oasis MCX cartridges. Electrospray (ESI) in positive and negative mode and tandem MS selected reaction monitoring mode were used for identification and quantification. Calibration by linear regression analysis with deuterated internal standards was used to compensate the matrix effects. Limits of detection were found as low as 0.5–1 ng/L (surface water) and 1–50 ng/L (wastewater). The method was applied to the analysis of different kinds of samples. Wastewater from a sewage treatment plant was collected from three sampling points (after primary, secondary, and tertiary treatments) for a week. The analysis of the samples revealed a significant presence of these drugs in samples from primary treatments, where maximum concentrations of nicotine (1105 ng/L) and benzoylecgonine (3336 ng/L) were found. Most of the compounds showed values between 相似文献   

11.
The new ionization method, called surface-activated chemical ionization (SACI), was employed for the analysis of fives drugs (morphine, codeine, 6-monoacetylmorphine (6-MAM), benzoylecgonine and cocaine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI), no-discharge-APCI and electrospray ionization (ESI) clearly showing that SACI is the most sensible one mainly due to the high ionization efficiency and the lower chemical noise. The performance of SACI in terms of sensitivity and linearity was compared with the sensitivity and linearity obtained using APCI, no-discharge-APCI and ESI, showing that the new SACI approach gives rise to the best results. Then, SACI was used to analyze morphine, codeine, 6-MAM, benzoylecgonine and cocaine in urine samples. After the optimization of the instrumental parameters for a mixture of the standard compounds, eight urine samples were analyzed. They were strongly diluted (1 : 20 and 1 : 100) in order to prevent the chromatographic column damage due to the matrix composition. Furthermore, the diluted urine samples were directly analyzed, without pretreatment, through LC-MS and LC-MS/MS, and the obtained results are reported.  相似文献   

12.
When cocaine is smoked, a pyrolytic product, methyl ecgonidine (anhydroecgonine methyl ester), is also consumed with the cocaine. The amount of methyl ecgonidine formed depends on the pyrolytic conditions and composition of the illicit cocaine. This procedure describes detection of cocaine and 10 metabolites--cocaethylene, nor-cocaine, nor-cocaethylene, methyl ecgonine, ethyl ecgonine, benzoylecgonine, nor-benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine and ecgonine--in blood and urine. In addition, the detection of pyrolytic methyl ecgonidine and three metabolites--ecgonidine (anhydroecgonine), ethyl ecgonidine (anhydroecgonine ethyl ester) and nor-ecgonidine (nor-anhydroecgonine)--are included. The newly described metabolites, ethyl ecgonidine and nor-ecgonidine, were synthesized and characterized by gas chromatography-mass spectrometry (GC-MS). All 15 compounds were extracted from 3 mL of blood or urine by solid-phase extraction and identified by a GC-MS method. The overall recoveries were 49% for methyl ecgonine, 35% for ethyl ecgonine, 29% for ecgonine and more than 83% for all other drugs. The limits of detection were between 0.5 and 4.0 ng/mL except for ecgonine, which was 16 ng/mL. Linearity for each analyte was established and in all cases correlation coefficients were 0.9985-1.0000. The procedure was applied to examine the concentration profiles of analytes of interest in post-mortem (PM) blood and urine, and in urine collected from living individuals (LV). These specimens previously were shown to be positive for the cocaine metabolite, benzoylecgonine. Ecgonidine, the major metabolite of methyl ecgonidine, was present in 77% of PM and 88% of the LV specimens, indicating smoking as the major route of cocaine administration. The new pyrolytic metabolites, ethyl ecgonidine and nor-ecgonidine, were present in smaller amounts. The urine concentrations of nor-ecgonidine were 0-163 ng/mL in LV and 0-75 ng/mL in PM specimens. Ethyl ecgonidine was found only in PM urine at concentrations 0-39 ng/mL. Ethanol-related cocaine metabolites, ethyl ecgonine or cocaethylene, were present in 69% of PM and 53% of cocaine-positive LV specimens, implying alcohol consumption with cocaine use. The four major metabolites of cocaine--benzoylecgonine, ecgonine, nor-benzoylecgonine and methyl ecgonine--constituted approximately 88 and 97% of all metabolites in PM and LV specimens, respectively. The concentrations of nor-cocaine and nor-cocaethylene were consistently the lowest of all cocaine metabolites. At benzoylecgonine concentrations below 100 ng/mL, ecgonine was present at the highest concentrations. In 20 urine specimens, benzoylecgonine and ecgonine median concentrations (range) were 54 (0-47) and 418 ng/mL (95-684), respectively. Therefore, detection of ecgonine is advantageous when benzoylecgonine concentrations are below 100 ng/mL.  相似文献   

13.
A single, isocratic high-performance liquid chromatographic method is described for the determination of cocaine and three of its metabolites along with caffeine in serum microsamples (50 microliters). The small sample size permits the tracking of pharmacokinetic data over time in individual, small animals. The method also was used to demonstrate that cocaine, benzoylecgonine and norcocaine in rat serum samples were stable for at least a month without the presence of sodium fluoride.  相似文献   

14.
The techniques of continuous-flow fast-atom bombardment (CF-FAB) and tandem mass spectrometry (MS/MS) are combined and applied to the analysis of small molecular mass drugs (mol.wt less than 500 Da). The approach involves the interfacing of a CF-FAB inlet with a triple-stage quadrupole mass spectrometer, enabling the acquisition of collision-activated decomposition mass spectra of the drugs after FAB ionization. The relationship between a stable sample surface on the CF-FAB probe tip and the quality of the mass spectrum is discussed, as are practical methods for obtaining and maintaining surface stability. CF-FAB MS/MS spectra for several drugs are presented, including penicillin G, phentolamine, cocaine and benzoylecgonine. Minimum detection limits range from 50-500 pg injected, depending on the compound. The reproducibility of the integrated areas of peaks from repetitive injections is approximately five per cent. Data are also presented for the direct CF-FAB MS/MS analysis of cocaine and benzoylecgonine in spiked urine samples.  相似文献   

15.
Su HL  Feng LI  Jen HP  Hsieh YZ 《Electrophoresis》2008,29(20):4270-4276
We have employed a high-sensitivity on-line preconcentration method, cation-selective exhaustive injection (CSEI) and sweeping MEKC, for the analysis of cocaine, benzoylecgonine, norcocaine, and cocaethylene. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations of SDS and organic modifier, the injection length of the high-conductivity buffer, and the injection time of the sample - to optimize the separation process. The optimal BGE was 100 mM phosphoric acid (pH 1.8) containing 75 mM SDS with 10% 2-propanol and 10% tetrahydrofuran as the organic modifier. In addition, electrokinetic injection of the sample at 15 kV for 900 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancements for cocaine, norcocaine, and cocaethylene ranged from 2.06 x 10(4) to 3.96 x 10(4); for benzoylecgonine it was 1.75 x 10(3); the coefficients of determination exceeded 0.9958. The LODs, based on an S/N ratio of 3:1, of sweeping-MEKC ranged from 33.5 to 52.8 ng/mL; in contrast, when using CSEI-sweeping-MEKC the sensitivity increased to range from 29.7 to 236 pg/mL. Under the optimal conditions, we analyzed cocaine in a human urine sample prepared using off-line SPE to minimize the influence of the matrix. The recovery of the SPE efficiency was satisfactory (ca. 74.9-87.6%). Our experimental results suggest that, under the optimal conditions, the CSEI-sweeping-MEKC method can be used to determine cocaine and its metabolites with high sensitivity in human urine.  相似文献   

16.
A combined assay is described for cocaine and its major metabolites, benzoylecgonine and ecgonine methyl ester. The method uses electrochemical and ultraviolet detectors in series. A non-silica column is used with high-pH mobile phase. The three compounds are completely separated from other cocaine metabolites. The assay has been suitable for pharmacokinetic studies of cocaine disposition in animal studies.  相似文献   

17.
Nonaqueous capillary electrophoresis (NACE) was applied to the determination of illicit drugs. The complete separation of amphetamine, methamphetamine, 3,4-methylene dioxy amphetamine (MDA), 3,4-methylene dioxy methamphetamine (MDMA), mescaline, cocaine and benzoylecgonine was obtained using an acetonitrile based buffer solution containing 10 mM sodium acetate and 1 M acetic acid. Electrochemical detection using a Pt microdisk electrode set to a potential of +1.8 V was found to be selective for MDA, MDMA and mescaline. The detection limits for these compounds were in the low ng/mL range which is between 2 and 3 orders of magnitude lower compared to UV-detection.  相似文献   

18.
Nonaqueous capillary electrophoresis (NACE) was applied to the determination of illicit drugs. The complete separation of amphetamine, methamphetamine, 3,4-methylene dioxy amphetamine (MDA), 3,4-methylene dioxy methamphetamine (MDMA), mescaline, cocaine and benzoylecgonine was obtained using an acetonitrile based buffer solution containing 10 mM sodium acetate and 1 M acetic acid. Electrochemical detection using a Pt microdisk electrode set to a potential of +1.8 V was found to be selective for MDA, MDMA and mescaline. The detection limits for these compounds were in the low ng/mL range which is between 2 and 3 orders of magnitude lower compared to UV-detection.  相似文献   

19.
《Analytical letters》2012,45(16):2572-2581
Pharmaceutical preparations of heroin and cocaine more than seventy years old were analyzed using RP-HPLC. The composition of mobile phase was optimized. The components were identified by MS2 or MS3, and the APPI fragmentation mechanisms of compounds found were proposed. The sample of heroin hydrochloride injection solution consists of 96.1% morphine and 3.9% of codeine. The sample of cocaine hydrochloride injection solution consists of 26.9% cocaine, 31.5% benzoylecgonine, 17.4% ecgonine, and 24.2% ecgonine methyl ester.  相似文献   

20.
Caslavska J  Thormann W 《Electrophoresis》2004,25(10-11):1623-1631
Commercial capillary electrophoresis instrumentation with XeHg lamp-based and laser induced fluorescence (LIF) detection is employed for analysis of urinary 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and its major metabolites, urinary metabolites of acetylsalicylic acid, urinary benzoylecgonine in an immunoassay format, and albendazole sulfoxide and albendazole sulfone in plasma. For the examples studied, the data suggest that the lamp-based detector can be employed for the monitoring of pharmacological and toxicological relevant solute concentrations, and thus represents an attractive alternative to LIF detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号