首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
A novel precursor monolithic capillary column referred to as “hydroxy monolith” or OHM was prepared by the in situ copolymerization of hydroxyethylmethacrylate (HEMA) with pentaerythritol triacrylate (PETA) yielding the neutral poly(HEMA‐co‐PETA) monolith. The neutral precursor OHM capillary thus obtained was subjected to postpolymerization modifications of the hydroxyl functional groups present on its surface with 1,2‐epoxyalkanes catalyzed by boron trifluoride (BF3) ultimately providing Epoxy OHM C‐m capillary column at varying alkyl chain lengths where m = 8, 12, 14, and 16 for RP‐CEC. Also, the same precursor OHM was grafted with octadecyl isocyanate yielding Isocyanato OHM C‐18 column to provide an insight into the effect of the nature of the linkage to the surface hydroxyl groups of the OHM precursor. While the epoxide reaction leaves on the surface of the OHM precursor hydroxy‐ether linkages, the isocyanato reaction leaves carbamate linkages on the same surface of the OHM precursor. This study revealed that changing the alkyl chain length resulted in changing the column phase ratio (?) and also the solute distribution constant (K). While increasing the surface alkyl chain length increased steeply the solute hydrophobic selectivity, i.e. methylene group selectivity, the nature of the ligand linkage produced different retention for the same solutes and affected the selectivity of slightly polar solutes. The various monoliths proved very useful for RP‐CEC of different small solutes at varying polarity over a wide range of mobile phase composition.  相似文献   

2.
A neutral naphthyl methacrylate‐based monolith (NMM) was introduced for RP‐CEC of various aromatic compounds via hydrophobic and π interactions. It was characterized over a wide range of elution conditions to gain insight into its RP retention mechanism toward the various solute probes under investigation. First, the NMM column exhibited cathodal EOF at various mobile phase compositions and pH suggesting that although the NMM column is void of fixed charges, it acquires a negative zeta potential. It is believed that the negative zeta potential is imparted by the adsorption of mobile phase ions to the NMM surface. The NMM column exhibited π–π interactions in addition to hydrophobic interactions due to the aromatic and nonpolar nature of its naphthyl ligands. In all cases, the retention of the various aromatic test solutes including PAHs, benzene derivatives, toluene derivatives, anilines and toluidine, tolunitrile and nitrotoluene positional isomers on the NMM column were compared to their retention on an octadecyl acrylate‐based monolithic column. Not only were the values of the retention factors of the various solutes on the NMM column higher than those obtained on the octadecyl acrylate‐based monolithic column under otherwise the same CEC conditions, but the elution orders were also different on both columns with a superior and unique selectivity exhibited by the NMM column.  相似文献   

3.
A polar polymethacrylate‐based monolithic column was introduced and evaluated as a hydrophilic interaction CEC stationary phase. The monolithic stationary phase was prepared by in situ copolymerization of a neutral monomer 2‐hydroxyethyl methacrylate and a polar cross‐linker N,N′‐methylene bisacrylamide in a binary porogenic solvent consisting of dodecyl alcohol and toluene. The hydroxyl and amino groups at the surface of the monolithic stationary phase provided polar sites which were responsible for hydrophilic interactions. The composition and proportion of the polymerization mixture was investigated in detail. The mechanical stability and reproducibility of the obtained monolithic column preformed was satisfied. The effects of pH and organic solvent content on the EOF and the separation of amines, nucleosides, and narcotics on the optimized monolithic column were investigated. A typical hydrophilic interaction CEC was observed on the neutral polar stationary phase. The optimized monolithic column can obtain high‐column efficiencies with 62 000–126 000 theoretical plates/m and the RSDs of column‐to‐column (n = 9), run‐to‐run (n = 5), and day‐to‐day (n = 3) reproducibility were less than 6.3%. The calibration curves of these five narcotics exhibited good linearity with R in the range of 0.9959–0.9970 and linear ranges of 1.0–200.0 μg/mL. The detection limits at S/N = 3 were between 0.2 and 1.2 μg/mL. The recoveries of the separation of narcotics on the column were in the range of 84.0–108.6%. The good mechanical stability, reproducibility, and quantitation capacity was suitable for pressure‐assisted CEC applications.  相似文献   

4.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

5.
A novel open‐tubular CEC column coated with chitosan‐graft‐(β‐CD) (CDCS) was prepared using sol‐gel technique. In the sol‐gel approach, owing to the 3D network of sol‐gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. The column efficiencies of 55 000~163 000 plates/m for the isomeric xanthopterin and phenoxy acid herbicides using the sol‐gel‐derived CDCS columns were achieved. Good stabilities were demonstrated that the RSD values for the retention time of thiourea and isoxanthopterin were 1.3 and 1.4% (run to run, n = 5), 1.6 and 2.0% (day to day, n = 3), 2.9 and 3.1% (column to column, n = 3), respectively. The sol‐gel‐coated CDCS columns have shown improved separations of isomeric xanthopterin in comparison with CDCS‐bonded capillary column.  相似文献   

6.
The separation and determination of proteins in food is an important aspect in food industry. Inspired by the self‐polymerization of dopamine under alkaline conditions and the natural adhesive properties of polydopamine, in this paper, a simple and economical method was developed for the preparation of polydopamine‐coated open tubular column, in which ammonium persulfate was used as the source of oxygen to induce and facilitate the polymerization of dopamine to form polydopamine. In comparison with a naked fused‐silica capillary, the direction and magnitude of the electro‐osmotic flow of the as‐prepared polydopamine‐coated open tubular column could be manipulated by varying the pH values of background solutions due to the existence of amine and phenolic hydroxyl groups on polydopamine coating. The surface morphology of the polydopamine‐coated open tubular column was studied by scanning electron microscopy, and the thickness of polydopamine coating was 106 nm. The performance of the polydopamine‐coated open tubular column was validated by analysis of proteins. The relative standard deviations of migration times of proteins representing run‐to‐run, day‐to‐day, and column‐to‐column were less than 3.5%. In addition, the feasibility of the polydopamine‐coated open tubular column for real samples was verified by the separation of proteins in chicken egg white and pure milk.  相似文献   

7.
In this work, an open‐tubular capillary liquid‐phase column was prepared by modifying chain polymer on the inner surface of capillary and chemical bonding of metal organic frameworks, NH2‐UiO‐66, to the brushes of chain polymer (poly(glycidyl methacrylate)). Besides advantages of facial preparation and good permeability, the chain polymer effectively increases the modification amount of NH2‐UiO‐66 nanoparticles to increase the phase ratio of open‐tubular capillary column and enhance the interactions with analytes. The results of scanning electron microscope energy‐dispersive X‐ray spectra indicated that NH2‐UiO‐66 nanoparticles were successfully bonded to the chain polymer. Because of the hydrophobic interaction and hydrogen bonding interaction between the analytes and the ligand of NH2‐UiO‐66, different analytes were well separated on the NH2‐UiO‐66‐modified poly(glycidyl methacrylate) capillary (1.12 m × 25 μm id × 365 μm od) with the high absolute column efficiency reaching 121 477 plates, benefiting from an open‐tubular column and low mass transfer resistance provided by polymer brush and metal–organic framework crystal. The relative standard deviations of the retention time for run‐to‐run, day‐to‐day, and column‐to‐column (= 3) runs are below 4.28%, exhibiting good repeatability. Finally, the column was successfully applied to separation of flavonoids in licorice.  相似文献   

8.
A simple “one‐pot” approach for the preparation of a new vinyl‐functionalized organic–inorganic hybrid monolithic column is described. In this improved method, the hydrolyzed alkoxysilanes of tetramethoxysilane and triethoxyvinylsilane were used as precursors for the synthesis of a silica‐based monolith, while 1‐hexadecene and sodium ethylenesulfonate were used as vinyl functional monomers along with azobisisobutyronitrile as an initiator. The effects of reaction temperature, urea content, and composition of organic monomers on the column properties (e.g. morphology, mechanical stability, and chromatographic performance) were investigated. The monolithic column was used for the separation of neutral solutes by reversed‐phase pressurized capillary. Furthermore, the monolith can separate various aromatic amines, which indicated its excellent cation‐exchange capability and hydrophobic interactions. The baseline separation of the aromatic amines was obtained with a column efficiency of up to 78 000 plates/m.  相似文献   

9.
Enantioselective open tubular capillary electrochromatography with carboxymethyl‐β‐cyclodextrin conjugated gold nanoparticles as stationary phase was developed. This novel open tubular column was fabricated through layer‐by‐layer self‐assembly of gold nanoparticles on a 3‐mercaptopropyl‐trimethoxysilane‐modified fused‐silica capillary and subsequent surface functionalization of the gold nanoparticles through self‐assembly of 6‐mercapto‐β‐cyclodextrin. The 6‐mercapto‐β‐cyclodextrin was firstly synthesized and determined by extensive spectroscopic data. Scanning electron microscopy, energy dispersive X‐ray analysis spectroscopy, and electroosmotic flow experiments were carried out to characterize the prepared open tubular column. Then, the separation effectiveness of the open tubular column was verified by two pairs of ɑ‐tetralones derivatives enantiomers and two pairs of basic drug enantiomers (tramadol hydrochloride and zopiclone) as mode analytes. Factors that influence the enantioseparation were optimized, and under the optimized conditions, satisfactory separation results were obtained for the four enantiomers: compound A, compound B, tramadol hydrochloride, and zopiclone with resolutions of 3.79, 1.56, 1.03, 1.60, respectively. For the combination of gold nanoparticles and negatively charged carboxymethyl‐β‐cyclodextrin, the open tubular column exhibited wider separation range for neutral and basic drugs. Moreover, the repeatability and stability of the column were studied through the run‐to‐run and day‐to‐day investigations.  相似文献   

10.
A novel mercaptotetrazole‐silica hybrid monolithic column was prepared for capillary liquid chromatography, in which the thiol‐end mercaptotetrazole was mixed with hydrolyzed γ‐methacryloxypropyltrimethoxysilane and tetramethyloxysilane for the co‐polycondensation and thiol‐ene click reaction in a one‐pot process. The effects of the molar ratio of silanes, the amount of mercaptotetrazole, and the volume of porogen on the morphology, permeability and pore properties of the as‐prepared mercaptotetrazole‐silica hybrid monoliths were investigated in detail. A series of test compounds including alkylbenzenes, amides and anilines were employed for evaluating the retention behaviors of the mercaptotetrazole‐silica hybrid monolithic columns. The results demonstrated that the mercaptotetrazole‐silica hybrid monoliths exhibited hydrophobic, hydrophilic as well as ion‐exchange interaction. The run‐to‐run, column‐to‐column and batch‐to‐batch reproducibilities of the mercaptotetrazole‐silica hybrid monoliths were satisfactory with the relative standard deviations less than 1.4 (= 5), 3.9 (= 3) and 4.0% (= 5), respectively. In addition, the mercaptotetrazole‐silica hybrid monolith was further applied to the separation of sulfonamides, nucleobases and protein tryptic digests. These successful applications confirmed the promising potential of the mercaptotetrazole‐silica hybrid monolith in the separation of complex samples.  相似文献   

11.
The thermal stability of poly[1‐(trimethylsilyl)‐1‐propyne] is investigated by heating the capillary column with this polymer as the stationary phase with the subsequent separation of the test mixture of light hydrocarbons. It is shown that heating of the column up to 130°C does not cause a decrease in efficiency or in the retention time of solutes. A further increase in temperature results in both decrease in column efficiency and sorbate retention. However, a decrease in column retentivity goes in one way for all the tested hydrocarbons. At the same time, the efficiency of the column is changed to a lesser degree for methane and ethane up to the temperature of polymer degradation, while for propane, butane, and iso‐butane the difference is rather sharp. The most expressed decrease in efficiency was found for iso‐butane: the column efficiency for this sorbate versus temperature of heating had two stages. The diffusion coefficients for sorbates in the polymeric phase were also evaluated and the sharp decrease in their values was found after the column heating.  相似文献   

12.
Metal‐organic frameworks consisting of amino‐modified MIL‐101(M: Cr, Al, and Fe) crystals have been synthesized and subsequently incorporated to glycidyl methacrylate monoliths to develop novel stationary phases for nano‐liquid chromatography. Two incorporation approaches of these materials in monoliths were explored. The metal‐organic framework materials were firstly attached to the pore surface through reaction of epoxy groups present in the parent glycidyl methacrylate‐based monolith. Alternatively, NH2‐MIL‐101(M) were admixed in the polymerization mixture. Using short time UV‐initiated polymerization, monolithic beds with homogenously dispersed metal‐organic frameworks were obtained. The chromatographic performance of embedded UV‐initiated composites was demonstrated with separations of polycyclic aromatic hydrocarbons and non‐steroidal anti‐inflammatory drugs as test solutes. In particular, the incorporation of the NH2‐MIL‐101(Al) into the organic polymer monoliths led to an increase in the retention of all the analytes compared to the parent monolith. The hybrid monolithic columns also exhibited satisfactory run‐to‐run and column‐to‐column reproducibility.  相似文献   

13.
《Electrophoresis》2018,39(7):924-932
In this work, an organic‐inorganic hybrid boronate affinity monolithic column was prepared via “one‐pot” process using 4‐vinylphenylboronic acid as organic monomer and divinylbenzene as cross‐linker. The effects of reaction temperature, solvents and composition of organic monomers on the column properties (e.g. morphology, permeability, and mechanical stability) were investigated. A series of test compounds including small neutral molecules, aromatic amines, and cis‐diol compounds were used to evaluate the retention behaviors of the prepared hybrid monolithic column. The results demonstrated that the prepared hybrid monolith exhibited mixed‐interactions including hydrophilicity, cation exchange, and boronate affinity interaction. The run‐to‐run, day‐to‐day and batch‐to‐batch reproducibilities of the prepared hybrid monolith for thiourea's retention time were satisfactory with the relative standard deviations (RSDs) less than 0.09, 1.45 and 4.05% (n = 3), respectively, indicating the effectiveness and practicability of the proposed method.  相似文献   

14.
《Electrophoresis》2018,39(12):1504-1511
Via the facile ring‐opening reaction of epoxy groups with quinine, a novel polymer monolith with quaternary ammonium for reversed‐phase/strong anion‐exchange mixed‐mode has been fabricated for pressurized capillary electrochromatography (pCEC). Optimization on the preparation of quinine‐modified monoliths has been investigated, and characteristics including morphology, permeability, mechanical stability, reproducibility, and column performance have been also studied. Active quaternary ammonium groups were conveniently produced to generate cationic action sites and stable anodic electroosmotic flow. Multiple interactions including reversed‐phase, strong anion‐exchange, electrostatic repulsion and π–π stacking interactions were obtained. Satisfactory separation capability of various analytes such as alkylbenzenes, polycyclic aromatic hydrocarbons, benzoic acid and its homologs, and β2‐receptor excitants has been achieved. Applied to the real sample, the good resolution of three alkaloids in Corydalis yanhusuo were achieved by pCEC with the quinine‐modified monolith. The results light a potential access to facilely fabricating quaternary ammonium‐functionalized polymer monolith with multiple interactions for efficient electrochromatography profiling of various compounds.  相似文献   

15.
A porous zwitterionic monolith was prepared by in situ covalent attachment of lysine to a γ‐glycidoxypropyltrimethosysilane‐modified silica monolith. The prepared column was used to perform neutral and ionized solutes separations by pressurized (pCEC). Due to the zwitterionic nature of the resulting stationary phase, the monolithic column provided both electrostatic attraction and repulsion sites for electrochromatographic retention for ionized solutes. Separation of several nucleotides was investigated on the monolithic column. It was shown that the nucleotides could be separated based on hydrophilic and electrostatic interactions between the stationary phase and analyte. Besides, the separation property of the zwitterionic silica monolith was compared with the use of diamine‐bonded silica monolith as stationary phase. As expected, the lysine monolith exhibited a lower retention for the five nucleotides, which was due to the dissociation of the external carboxylic acid groups, leading to electrostatic repulsion with negatively charged solutes. Under the same experimental conditions, separation of the five nucleotides on the zwitterionic column was in less than 8 min, while that on the diamine column was in approximately 60 min.  相似文献   

16.
A novel (3‐sulfopropyl methacrylate potassium)‐silica hybrid monolithic column for CEC has been prepared by a simple one‐pot approach based on efficient thiol‐ene click chemistry. In this process, the polycondensation of hydrolyzed alkoxysilanes and in situ click reaction of vinyl groups on 3‐sulfopropyl methacrylate potassium and thiol groups on the precondensed siloxanes simultaneously occurred in a pretreated capillary. Homogeneous monolithic matrix with large through‐pores tightly bonded to the inner wall of the capillary was shown by optical microscope and SEM. The minimum plate height of this hybrid monolithic column was determined as 3.9 μm for thiourea. Anilines, alkylbenzenes, and phenols were well separated on this hybrid monolithic column by CEC, which indicated typical reversed‐phase and cation‐exchange chromatographic retention mechanisms of the column.  相似文献   

17.
A series of π‐conjugated polymers linked by benzocarborane (1,2‐(buta‐1′,3′‐diene‐1′,4′‐diyl)‐1,2‐dicarbadodecaborane) were synthesized via Sonogashira–Hagihara polycondensation reaction. The opened molecular structure of diiodo monomer containing benzocarborane resulted in fast polymerization and high molecular weights. The obtained polymers were fully characterized by 1H, 13C, and 11B NMR spectroscopies. UV‐vis absorption and photoluminescence studies revealed the acceptor‐profile of benzocarborane. Unlike the polymers linked by o‐carborane, these polymers exhibited strong luminescence in the solution state, presumably because the inductive effect of carborane is dominant, rather than cage‐π interactions.

  相似文献   


18.
In this work, we developed a capillary column modified with zeolitic imidazolate framework‐8 as a novel stationary phase for open‐tubular capillary electrochromatography. To immobilize zeolitic imidazolate framework‐8 onto the inner surface of silica capillary, a bio‐inspired polydopamine functionalization was used to functionalize the capillary surface with polydopamine. First, a polydopamine layer was assembled inside the capillary. Second, due to noncovalent adsorption and covalent reaction ability, polydopamine could attract and anchor zeolitic imidazolate framework‐8 onto the inner surface of capillary. It has been demonstrated that zeolitic imidazolate framework‐8 was successfully grafted on the inner wall of the capillary by scanning electron microscopy, and Fourier transform infrared spectroscopy. The electro‐osmotic flow characteristics of capillaries were also investigated by varying the pH value and acetonitrile content of mobile phase. The zeolitic imidazolate framework‐8 coating not only increased the phase ratio of open‐tubular column, but also improved the interactions between tested analytes and the stationary phase. Three groups of isomers including acidic, basic, and neutral compounds were well separated on the zeolitic imidazolate framework‐8 bonded column, with theoretic plate numbers up to 1.9 × 105 N for catechol. The repeatability of the prepared columns was also studied, and the relative standard deviations for intra‐ and interday runs were less than 5%.  相似文献   

19.
The paper concerns the analysis of volatile hydrocarbons on newly designed and produced capillary columns. According to the type of coating used, the columns are of the PLOT type, and according to the adsorbate‐adsorbent type interactions they belong to the category of complexation GC. The adsorbent used was silica, whose surface was modified with bonded 2‐(3‐triethoxysilylpropylimino)‐3‐(benzyl)‐pentanone‐4 to change the adsorption characteristics. The presence of the ketoimine group of strongly electron‐accepting properties permitted the binding of transition metals. The metal ions are capable of interacting selectively with nucleophilic compounds including olefins. The transition metal ions used for sorbent modification were copper(II) chlorides and nickel(II) chlorides. The supported adsorbent was immobilised by bonding the modified silica to the column walls by a film of poly(dimethylsiloxane). Due to this strategy, the coating was very stable, no sorbent loss from the column was observed and the column could be washed with solvent. Besides exemplary separations, the paper quotes retention parameters of the group of compounds analysed and presents a discussion of the specific interactions between the adsorbate and adsorbent.  相似文献   

20.
A novel amphiphilic silica‐based monolithic column having surface‐bound octanoyl‐aminopropyl moieties was successfully prepared by a one‐step in situ derivatization process. As expected, the amphiphilic monolithic column exhibited RP chromatographic behavior toward non‐polar solutes (e.g., alkyl benzenes) with high column performance. As the pH of the buffer inside the column increases, the EOF changed from −2.65×10−8m2 V−1s−1 at pH 3.0 to 1.20×10−8 m2 V−1s−1 at pH 8.0 with the reversion of EOF at about pH 6.4. Using acidic mobile phase, five aromatic acids can be efficiently separated in less than 6 min under co‐EOF conditions. For basic compounds, symmetrical peaks were obtained due to the existence of hydrophilic acyl amide group, which can effectively minimize the adsorption of the positively charged basic analyte to the silica‐based surface of the capillary column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号