首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The comparative determination of lead in plant samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomisation atomic absorption spectrometry (ETAAS) was applied. The results obtained were compared with those found after a wet digestion procedure by flame atomic absorption spectrometry (FAAS) or ETAAS. The accuracy of the studied methods was checked using a certified reference material (CL???1 CRM, Cabbage Leaves). The recovery of lead was 90% for slurry sampling ETAAS, and 86.6% for liquid sampling ETAAS. The advantages of the slurry sampling ETAAS method are the simplicity of sample preparation and very good sensitivity.  相似文献   

2.
Systematic errors observed when using flame atomic absorption spectrometry (FAAS) and electrothermal atomic spectrometry (ETAAS) for the analysis of biological solid materials (seafood products) were evaluated. The effect of the sample pre-treatment method (microwave-assisted acid digestion, ultrasound-assisted acid leaching and slurry sampling) as well as the number of times that a certain pre-treatment process is repeated, were two factors evaluated. They give information about the effect of the sample pre-treatment on the uncertainty in the analysis. In addition, the number of measurements (i.e., number of times that an acid digest, an acid leachate or aqueous slurry are analysed) and the calibration technique used (aqueous calibration method or standard addition technique) were other two variables taken into account. This last factor gives information about the effect of the calibration on the results, while the replicate measurements showed the repeatability. A fifth variable named as sample matrix tests the influence of the matrix sample on the systematic error through the use of different reference materials. This variable allows the study of the effect of the trace element concentrations on the uncertainty because the trace elements contents are different in each reference material. Experimental design and principal component analysis approaches were used as chemometric tools. It has been found that the use of the slurry sampling technique in ETAAS and FAAS and the determination of high element concentrations by ETAAS have led to poor precision.  相似文献   

3.
Fly ash samples of cement works were analysed using slurry nebulization inductively coupled plasma atomic emission spectrometric (ICP-AES). Because of the influence of the experimental factors on the signal intensity, the optimal conditions of the analysis circumstances were determined. Control analyses (wet digestion followed by ICP-AES, and XRF of dry powders (pressed pellets)) were also carried out to compare the results. Based on the result, it was concluded that the slurry nebulization method using slurry standard of same type reference material for calibration can be applied for rapid but less precise (RSD 5–10%) determination of the elements in fly ash.  相似文献   

4.
Silva MM  Goreti M  Vale R  Caramão EB 《Talanta》1999,50(5):1035-1043
A procedure for lead, cadmium and copper determination in coal samples based on slurry sampling using an atomic absorption spectrometer equipped with a transversely heated graphite tube atomizer is proposed. The slurries were prepared by weighing the samples directly into autosampler cups (5-30 mg) and adding a 1.5 ml aliquot of a diluent mixture of 5% v/v HNO(3), 0.05% Triton X-100 and 10% ethanol. The slurry was homogenized by manual stirring before measurement. Slurry homogenization using ultrasonic agitation was also investigated for comparison. The effect of particle size and the use of different diluent compositions on the slurry preparation were investigated. The temperature programmes were optimized on the basis of pyrolysis and atomization curves. Absorbance characteristics with and without the addition of a palladium-magnesium modifier were compared. The use of 0.05% m/v Pd and 0.03% m/v Mg was found satisfactory for stabilizing Cd and Pb. The calibration was performed with aqueous standards. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling. Better recoveries of the analytes were obtained when the particle size was reduced to <37 mum. Several certified coal reference materials (BCR Nos. 40, 180, and 181) were analyzed, and good agreement was obtained between the results from the proposed slurry sampling method and the certificate values.  相似文献   

5.
The analytical conditions of the direct determination of bismuth in some certified reference material samples (soil and sediment) by slurry sampling Zeeman electrothermal atomic absorption spectrometry (ETAAS) with the use of automated ultrasonic slurry mixing are discussed. Palladium nitrate was used as a chemical modifier. With the use of this modifier it was possible to stabilize bismuth to the pyrolysis temperature of 1300 °C. Platform atomization was performed at 2050 °C. The results of determination are calculated from a simple, aqueous standards based calibration graph. Statistical evaluation of the results indicate that the slurry sampling method is reproducible and the accuracy of the proposed method is very good. This method is rather simple and its other advantages are good sensitivity and relatively short analysis time.  相似文献   

6.
A simple procedure for the determination of manganese in different sections of human brain samples by graphite furnace atomic absorption spectrometry has been developed. Brain sections included cerebellum, hypothalamus, frontal cortex, vermix and encephalic trunk. Two sample preparation procedures were evaluated, namely, slurry sampling and microwave-assisted acid digestion. Brain slurries (2% w/v) could be prepared in distilled, de-ionized water, with good stability for up to 30 min. Brain samples were also digested in a domestic microwave oven using 5 ml of concentrated HNO3. A mixed palladium+magnesium nitrate chemical modifier was used for thermal stabilization of the analyte in the electrothermal atomizer up to pyrolysis temperatures of 1300 °C, irrespective of the matrix. Quantitation of manganese was conducted in both cases by means of aqueous standards calibration. The detection limits were 0.3 and 0.4 ng ml−1 for the slurry and the digested samples, respectively. The accuracy of the procedure was checked by comparing the results obtained in the analysis of slurries and digested brain samples, and by analysis of the NIST Bovine Liver standard reference material (SRM 1577a). The ease of slurry preparation, together with the conventional set of analytical and instrumental conditions selected for the determination of manganese make such methodology suitable for routine clinical applications.  相似文献   

7.
The development of a slurry sampling method for the determination of calcium, copper, iron, magnesium and zinc in fish tissue samples by flame atomic absorption spectrometry is described. In comparison with microwave-assisted digestion, the proposed method is simple, requires short time and eliminates total sample dissolution before analysis. Suspension medium was optimized for each analyte to obtain quantitative recoveries from fish tissue samples without matrix interferences. Nevertheless, iron recoveries higher than 46% were not found. Treatment of samples slurried in nitric acid by microwave irradiation for 15-30 s at 75-285 W permitted to achieve efficient recoveries for calcium, iron, magnesium and zinc. Further improvement in the matrix effects for iron determination was accomplished by the use of an additional step of short microwave-assisted suspension treatment. However, standard addition method was required for calcium and copper determination, being necessary hydrochloric acid as suspension medium for the last one. Although copper could not be determined in the certified reference material using microwave-assisted digestion, the accuracy of the slurry sampling method was verified for all the investigated analytes. Detection limits were 22.8 ± 8.0, 0.884 ± 0.092, 5.07 ± 0.76, 35.5 ± 0.7 and 1.17 ± 0.04 μg g−1 for calcium, copper, iron, magnesium and zinc, respectively. The standard deviations obtained using slurry sampling method and microwave-assisted digestion were not significantly different, and the mean relative standard deviation of the over-all method (n = 3) of the slurry sampling method for different concentration levels was below 12%.  相似文献   

8.
A slurry sampling ETAAS method for the determination of trace concentrations of Ca, Co, Cr, Cu, Fe, K, Mg, Na and Ni in tungsten trioxide is presented. A high background absorption appearing with large sample amounts during atomization at high temperatures was the only matrix interference observed. It could be significantly reduced by volatilization of the matrix in the pyrolysis step. Calibration curves recorded with aqueous standards could be used for calibration in all cases excluding the determination of very low analyte concentrations of Co and Fe which required the use of the standard additions method. The results obtained by this method showed an excellent agreement with those determined in digests by ETAAS. The detection limits achievable by the slurry technique were between 1 (Ca, K, Mg, Na) and 210 (Cu) ng/g. They were mostly by more than one order of magnitude better than those of the solution techniques.  相似文献   

9.
A slurry sampling ETAAS method for the determination of trace concentrations of Ca, Co, Cr, Cu, Fe, K, Mg, Na and Ni in tungsten trioxide is presented. A high background absorption appearing with large sample amounts during atomization at high temperatures was the only matrix interference observed. It could be significantly reduced by volatilization of the matrix in the pyrolysis step. Calibration curves recorded with aqueous standards could be used for calibration in all cases excluding the determination of very low analyte concentrations of Co and Fe which required the use of the standard additions method. The results obtained by this method showed an excellent agreement with those determined in digests by ETAAS. The detection limits achievable by the slurry technique were between 1 (Ca, K, Mg, Na) and 210 (Cu) ng/g. They were mostly by more than one order of magnitude better than those of the solution techniques. Received: 9 July 1997 / Revised: 6 October 1997 / Accepted: 10 October 1997  相似文献   

10.
Slurry-sampling electrothermal atomic absorption spectrometry has been applied to the determination of lead in several biological samples (fish and marine algae). The slurries were prepared both by magnetic shaking and microwave-heating and the effect of instrument operating conditions and slurry preparation conditions on the signal were examined. In addition, results from slurry sampling were compared with those obtained by microwave-assisted acid digestion of the same samples and no significant differences were found between them when the analysis of variance (ANOVA) was applied. The between-batch precision of the slurry techniques employed was similar to that for the microwave-assisted digestion procedure; values were always below 6.7%, except for the Dicentrarchus labrax sample for which the value obtained was 9.5% when using slurry magnetic shaking and 7.6% when using the slurry microwave heating. The accuracy of the slurry methodology employed was also evaluated by analysis of two biological reference materials (NIST-1577b and IAEA-V10); percentage recoveries obtained were between 95.6 and 98.5% of the values certified for lead.  相似文献   

11.
Coşkun N  Akman S 《Talanta》2004,64(2):496-500
Manganese in vitamin-minerals tablets was determined by solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS) using three different calibration methods, namely calibration against aqueous standards, standard addition with aqueous standards on solid samples and calibration against solid certified standards. Samples were only finely ground and introduced directly into the furnace by means of solid autosampler system without any dissolving process. Effects of different calibration techniques, temperatures and heating rates of atomization and pyrolysis steps on the accuracy and precision of the analyte elements were investigated. After optimization of the experimental parameters, there is good agreement (at 95% confidence level) between the results obtained by solid sampling and those obtained by acid digestion of samples.  相似文献   

12.
A solid sampling electrothermal atomic absorption spectrometry method for direct determination of trace silicon in biological materials was developed and applied to analysis of pork liver, bovine liver SRM 1577b and pure cellulose. The organic matrix was destroyed and expelled from the furnace in the pyrolysis stage involving a step-wise increasing the temperature from 160 °C to 1200 °C. The mixed Pd/Mg(NO3)2 modifier has proved to be the optimum one with respect to the achievement of maximum sensitivity, elimination of the effect of the remaining inorganic substances and the possibility of using calibration curves measured with aqueous standard solutions for quantification. For the maximum applicable sample amount of 6 mg, the limit of detection was found to be 30 ng g− 1. The results were compared with those obtained by different spectrometric methods involving sample digestion, by electrothermal atomic absorption spectrometry using slurry sampling, by wavelength dispersive X-ray fluorescence spectrometry and by radiochemical neutron activation analysis. The method seems to be a promising one for analysis of biological materials containing no significant fraction of silicon in form of not naturally occurring volatile organosilicon compounds. The still incessant serious limitations and uncertainties in the determination of trace silicon in solid biological materials are discussed.  相似文献   

13.
A direct solid sampling electrothermal atomic absorption spectrometric method for determination of Cd, Co, Cr, Cu, Fe, Li, Mn, Ni and Zn in zirconium dioxide has been developed. Using optimised experimental conditions, very effective in-situ analyte/matrix separation was achieved without any chemical modification. After the measurement, the matrix residue could easily be tipped out from the platform. In the determination of Cr, before sampling, the platform bottom was covered with carbon powder. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the matrix residue from a previous sample run. Sample amounts between 0.5 and 40 mg were applied for each analysis cycle. The accuracy was determined by comparison of the results with those obtained by radiochemical neutron activation analysis and by electrothermal atomic absorption spectrometry using liquid sampling of digests and slurry sampling. For the nine elements assayed, the limits of detection achievable by this method are between 0.06 ng g–1 (Cd) and 2.3 ng g–1 (Fe).Dedicated to the memory of Wilhelm Fresenius  相似文献   

14.
Fast-heating programmes for determining titanium and tin in soils, sediments and sludges using electrothermal atomic absorption spectrometry (ETAAS) with slurry sampling are developed. For titanium determination, suspensions are prepared by weighing 5-40 mg of sample and adding 25 ml of a solution containing 50% (v/v) concentrated hydrofluoric acid. For tin determination, suspensions are prepared by weighing up to 300 mg of sample and then adding 1 ml of a solution containing 25% (v/v) concentrated hydrofluoric acid. Palladium (30 μg) and ammonium dihydrogen phosphate (7% w/v) are used as matrix modifiers for titanium and tin, respectively. Prior mild heating in a microwave oven is recommended for titanium determination. Calibration is carried out using aqueous standards. The tin and titanium contents of a number of samples obtained by using the slurry approach agree with those obtained by means of a procedure based on the total dissolution of the samples using microwave oven digestion. The reliability of the procedures is also confirmed by analysing several certified reference materials.  相似文献   

15.
A simple and rapid slurry sampling electrothermal atomic absorption spectrometric (ETAAS) method was developed for the determination of traces of sodium and iron in single crystals of rubidium titanyl phosphate (RTP). The finely ground crystal material was dispersed in 5mL of 2% (v/v) HNO3, containing 0.005% (v/v) Triton-X-100. The fast furnace ETAAS analysis was performed using a pyrolytic platform coated with titanium carbide. No matrix interference was registered for either of the analytes in slurries containing 4 to 10mgmL–1 of RTP, which permitted simple calibration against aqueous solutions. The precision was about 2% RSD. The results for sodium and iron content in RTP were in good agreement with those obtained by flame AAS after sample digestion.  相似文献   

16.
Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method was elaborated to the determination of Hg in sewage sludge samples with the use of KMnO4+Pd modifier. The minimum sample amount required for slurry preparation with respect to sample homogeneity was evaluated by weighting masses between 3 and 30 mg directly into the autosampler cups. Validation of the proposed method was performed with the use of Certified Reference Materials of sewage sludge, CRM 007-040 and CRM 144R. Two sewage sludge samples from Poznañ (Poland) city were analysed using the present direct method and a method with sample digestion, resulting in no difference within statistical error.  相似文献   

17.
An ultrasonic slurry sampling electrothermal atomic absorption spectrometric method with a molybdenum tube atomizer has been developed for the determination of copper in herbal medicine samples. Glycerol solution (10%) was used as the slurry medium. The optimum pyrolysis temperature was 760 °C. The detection limit was 72 fg (3×S/N ratio). Matrix element interference was investigated and it was found that glycerol as a chemical modifier eliminated the interference. The amounts of copper in herbal medicines determined by the method proposed are in good accordance with those measured in dissolved acid-digested samples. The method enables rapid calibration, and simple and rapid analysis of copper in herbal medicine samples at low cost.  相似文献   

18.
A simple method for determining lead in fine particulates (PM2.5) by using electrothermal atomic absorption spectrometry (ETAAS) has been developed. Particulates collected on Nuclepore filter by using a dichotomous sampler were suspended in diluted nitric acid after ultrasonic agitation. The dislodging efficiency is nearly 100% after agitation for 5 min. In order to study the suspension behavior of PM2.5 in solvents, a Brookhaven ZetaPlus Particle Size Analyzer was used to determine the particle size distribution and suspension behavior of air particulates in the solvent. The pre-digestion and modification effect of nitric acid would be discussed. Palladium was added as a chemical modifier and the temperature program of ETAAS was changed in order to improve the recovery. The slurry was introduced directly into a graphite tube for atomization. The metal content in the sample was determined by the standard addition method. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling method. It offers a quick and efficient alternative method for heavy metal characterization in fine particulates.  相似文献   

19.
 Combined analytical procedures consisting of wet digestion step followed by instrumental determination – differential pulse cathodic stripping voltammetry (DPCSV) or electrothermal atomic absorption spectrometry (ETAAS) – as well as a direct analysis method – slurry sampling ETAAS – for the determination of Cd, Co, Cr, Cu, Fe, Ni and Pb in milk, cheese and chocolate are described and compared. Wet digestion using a mixture of HNO3-HClO4-H2O2 is proposed for complete matrix decomposition prior to trace analyte determinati on by DPCSV or ETAAS. A mixture of HNO3-H2O2 is used for slurry preparation. Optimal instrumental parameters for trace analyte measurements are presented. The reliability of the procedures has been verified by analyzing standard reference materials. Results obtained are in good agreement with the certified values and the relative standard deviations (for these results) are in the range 5–10% for wet digestion DPCSV or ETAAS and 3–9% for slurry sampling ETAAS in the range of 2 μgċg−1 (Cd) to 12 μgċg−1 (Fe). Received August 24, 1999. Revision January 20, 2000.  相似文献   

20.
Direct solid sampling Zeeman atomic absorption spectrometric methods were developed and applied to the determination of mercury, cadmium, manganese, lead and tin in seafood. All elements but mercury were measured by a third generation Zeeman atomic absorption spectrometry combined with an automatic solid sampler. In 3-field- and dynamic mode the calibrations concentration range was substantially extended and high amounts of analyte were detectable without laborious dilution of solid samples. The measurements were based on calibrations using certified reference materials of organic matrices. In case solid certified reference materials were not available calibration by aqueous standard solutions was proved to be an alternative. No matrix effects were observed under the optimized conditions. Results obtained were in good agreement with the certified values. Solid sampling Zeeman atomic absorption spectrometry proved to be a reliable, rapid and low-cost method for the control of trace elements in seafood.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号