首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
在不锈钢蒸汽消毒器中用K2S2O8将水中含氮物质中的N氧化为NO3-,用离子色谱测定,从而测定水中总氮量。实验对K2S2O8氧化液用量及反应时间等进行探讨,并对长江水中总氮量进行了测定。实验结果表明测定最佳条件是氧化时间10 min以上、氧化剂用量为理论用量的5倍;长江水(武汉段)总氮量为2.09 mg/L,测得的总氮量与文献报道的基本吻合。  相似文献   

2.
采用紫外光-臭氧氧化结合离子色谱法对氧化消解后的水样同时进行总磷和总氮的测定。配制Na2CO3/NaHCO3淋洗液,采用1 mL定量环,大体积直接进样。在优化工作条件下,总磷在0.05~5.00 mg/L,总氮在0.10~10.0 mg/L范围内线性良好,线性相关系数分别为0.9999和0.9998,总磷和总氮检出限为分别3.60和4.57μg/L;总磷和总氮的检测相对标准偏差(RSD)分别低于4.9%和4.1%,总磷加标回收率为95.0%~105.0%,总氮加标回收率为93.0%~103.0%。自然环境水样检测与真实值相对偏差小于4.2%。本方法选择性好,灵敏度高,精密度和准确度高,用于实际水样中总磷和总氮含量测定的结果与国标法(GB11894-89,GB11893-89)基本一致  相似文献   

3.
A methodology based on microwave‐assisted extraction (MAE) and LC with fluorescence detection (FLD) was investigated for the efficient determination of 15 polycyclic aromatic hydrocarbons (PAHs) regarded as priority pollutants by the US Environmental Protection Agency and dibenzo(a,l)pyrene in atmospheric particulate samples. PAHs were successfully extracted from real outdoor particulate matter (PM) samples with recoveries ranging from 81.4 ± 8.8 to 112.0 ± 1.1%, for all the compounds except for naphthalene (62.3 ± 18.0%) and anthracene (67.3 ± 5.7%), under the optimum MAE conditions (30.0 mL of ACN for 20 min at 110°C). No clean‐up steps were necessary prior to LC analysis. LOQs ranging from 0.0054 ng/m3 for benzo(a)anthracene to 0.089 ng/m3 for naphthalene were reached. The validated MAE methodology was applied to the determination of PAHs from a set of real world PM samples collected in Oporto (north of Portugal). The sum of particulate‐bound PAHs in outdoor PM ranged from 2.5 and 28 ng/m3.  相似文献   

4.
Kei Toda  Yuki Hato  Shin-Ichi Ohira 《Talanta》2007,71(4):1652-1660
Sequential injection analysis (SIA) was applied to multi-gas monitoring for atmospheric analysis. HONO, NO2 or NO was collected in an individual diffusion scrubber in which the channel array was filled with either HCl or triethanolamine solution. All analytes were collected in the form of nitrite ions in the scrubber, and were transferred via a 12-port selection valve into a 2.5-ml syringe. The reagent, 3-amino-1,5-naphthalenedisulfonic acid (C-acid) solution was subsequently introduced into the syringe, and inter-mixed with the nitrite sample, whereafter the mixed solution was transferred to a heated reactor and held for 3 min at 100 °C. After that, the sample/reagent solution was returned to the syringe and alkalinized. Then, the final solution was analyzed using a homemade fluorescence detector. Atmospheric HONO, NO2 and NO were successfully monitored 3 or 4 times/h. The limits of detection were 0.22, 0.28 and 0.35 ppbv for HONO, NO2 and NO, respectively. It was demonstrated for the first time that SIA is a good tool for multi-gas atmospheric analysis. These nitrogen-oxygen compounds are interconvertible, and the simultaneous measurement of these gases is important. Especially, HONO is a source of OH radicals which contribute greatly to atmospheric pollution, and indeed atmospheric chemistry. This method allows the three gases to be measured using one system. The NO2 and NO data obtained by SIA was compared with those obtained using chemiluminescence instrument. SIA has been successfully applied to atmospheric measurements. Interestingly, it was observed that HONO levels rose toward the end of periods of rain.  相似文献   

5.
用液相色谱/大气压化学电离离子阱质谱建立了一种分析烟草中游离茄尼醇的方法。烟草样品用甲醇振荡提取30 min,在分析前无需进行其它前处理。在1.8μm快速分离C18色谱短柱上用V(甲醇)∶V(异丙醇)=85∶15等梯度洗脱实现了茄尼醇的快速分离。用不带碰撞能量的二级质谱全扫描选择监测离子m/z 613.6进行定量,检出限为0.4μg/L,RSD为1.1%,两种添加量的回收率分别为97%和99%。方法应用于不同烟草和烟草制品样品的检测分析。  相似文献   

6.
A new high-performance ion chromatography assay for organic and inorganic nitrogen analysis has been proposed and examined. In the devised protocol, inorganic sample constituents were measured after ultrasonically assisted water extraction. The amine and amide nitrogen content was assessed after modified Kjeldahl digestion and determined as NH4+, and the total nitrogen content was quantified as NO3 after microwave-facilitated digestion. Finally, the nitro, azo, azoxy nitrogen was calculated by comparison of the total nitrogen content and all measured nitrogen species. The detection limits of the measured ions were 2.0, 0.82 and 0.17 mg L−1 for nitrate, nitrite and ammonium, respectively. For samples of potatoes, the average shares of the nitrogen species found in the total nitrogen content were: 0.83% of nitrate nitrogen, <0.03% of nitrite nitrogen, 2.1% of ammonium nitrogen, 71% of nitro, azo, azoxy nitrogen, and 26% of amine, amide nitrogen. We expect the method to be applicable to different vegetable samples. The quality of the results obtained was verified by analyzing certified reference material and comparing to another analytical method.  相似文献   

7.
A microwave-assisted digestion procedure using HNO3, HF, and H2O2 has been developed for analysis of elements in ambient particulate matter (PM). The samples are collected on cellulose filters and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS is calibrated with external standards, and recovery of analytes is tested with NIST SRM 1648 Urban Dust. This method has been used to quantify the airborne concentrations of a large number of elements, including Ag, As, Ba, Be, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, K, Li, Mg, Mn, Mo, Ni, Pb, Rb, Se, Sb, Sr, Ti, Tl, V, and Zn. For the majority of these elements, recovery of the NIST SRM is within 15% of the certified values.  相似文献   

8.
A simple, sensitive and fast ion chromatographic (IC) method with suppressed conductivity detection is described for the determination of traces of nitrogen in uranium based fuel materials. Initially a method was developed to determine nitrogen as NH4+ using cation exchange column after matrix separation by Kjeldahl distillation. The method was then improved by eliminating this distillation. Matrix separation after sample dissolution was done by hydrolyzing and filtering off the polyvalent cations. This had helped in reducing both the sample size and analysis time. Optimization of dissolution conditions for various kinds of uranium based samples was done to keep acid content minimum; a prerequisite chromatographic condition. The calibration plot for nitrogen was linear in the concentration range of 0.02-1 mg L−1 with regression coefficient of 0.9999. The relative standard deviation (R.S.D.) obtained in this method (100 μL injected) was 3% and 2% in 9 replicates at nitrogen level of 28 and 55 ng g−1, respectively. Detection limit based on S/N = 3 (100 μL injected) as well as three times of variation in blank value was 4 ng g−1. The developed method was authenticated by comparison with certified uranium-alloy standard as well as with independent indophenol photometry method. The developed method was applied to uranium-alloy, uranium-metal, sintered UO2 pellets and sintered UO2 microspheres samples.  相似文献   

9.
离子色谱法测定卷烟主流烟气中的氮氧化物   总被引:5,自引:0,他引:5  
采用一种全新的离子色谱法测定卷烟主流烟气中氮氧化物,即采用装有5%三乙醇胺溶液的多孔玻板吸收瓶吸收卷烟主流烟气中NO2(NO先用CrO3氧化管氧化为NO2),使之转化为NO2-和NO3-,然后用离子色谱同时检测。由于采用合适的梯度淋洗条件,不需任何样品预处理即可直接检测,方法简便快速。结果表明,本法在0.5-10 mg/L具有良好的线性关系;相对标准偏差小于2%;NO2-和NO3-的检出限分别为0.04mg/L、0.05 mg/L;回收率为97%-101%。  相似文献   

10.
The total Kjeldahl nitrogen (TKN) method was simplified by using a manifold connected to a purge-and-trap system immersed into an ultrasonic (US) bath for simultaneous ammonia (NH3) extraction from many previously digested samples. Then, ammonia was collected in an acidic solution, converted to ammonium (NH4+), and finally determined by ion chromatography method. Some variables were optimized, such as ultrasonic irradiation power and frequency, ultrasound-assisted NH3 extraction time, NH4+ mass and sulfuric acid concentration added to the NH3 collector flask. Recovery tests revealed no changes in the pH values and no conversion of NH4+ into other nitrogen species during the irradiation of NH4Cl solutions with 25 or 40 kHz ultrasonic waves for up to 20 min. Sediment and oil free sandstone samples and soil certified reference materials (NCS DC 73319, NCS DC 73321 and NCS DC 73326) with different total nitrogen concentrations were analysed. The proposed method is faster, simpler and more sensitive than the classical Kjeldahl steam distillation method. The time for NH3 extraction by the US-assisted purge-and-trap system (20 min) was half of that by the Kjeldahl steam distillation (40 min) for 10 previously digested samples. The detection limit was 9 μg g−1 N, while for the Kjeldahl classical/indophenol method was 58 μg g−1 N. Precision was always better than 13%. In the proposed method, carcinogenic reagents are not used, contrarily to the indophenol method. Furthermore, the proposed method can be adapted for fixed-NH4+ determination.  相似文献   

11.
Oms MT  Cerdà A  Cerdà V 《Talanta》2003,59(2):319-326
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 g l−1 of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h−1. The LOD is 0.6 mg l−1 N and the reproducibility is 1.8% (28 mg l−1 N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter.The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.  相似文献   

12.
利用甲基丙烯酸甘油酯制备了强阳离子交换毛细管离子色谱有机聚合整体柱(内径0.32mm,长10cm)。利用该阳离子交换柱测定了自来水中钙和镁的质量浓度,以考察水质的硬度,相对标准偏差在0.4%~1,0%范围内,加标回收率在98.2%-103%之间。该色谱柱具有节省溶剂消耗,制备简单,造价低廉等优点。  相似文献   

13.
We present the development of a method for the simultaneous determination of inorganic nitrogen species in oxidized (NO2, NO3) and reduced (NH4+) forms using ion chromatography with diode‐array detection (205, 208, and 425 nm, respectively). The oxidized forms were determined directly after the separation in the anion exchanger, while the reduced form was determined in the column hold‐up time after derivatization with the Nessler reagent. The use of an appropriate modifier (Seignette reagent) and mobile phase (NaCl) enabled the determination of inorganic nitrogen species in highly salinated environmental samples (water, sediments). Moreover, low detection limits were obtained of 0.04 mg/L for NH4+ and 0.006 and 0.005 mg/L for NO2 and NO3, respectively. The analysis of environmental samples indicated NH4+ contents of up to 1161 ± 47 mg/kg and NO3 of up to 148 ± 6 mg/kg for sediment samples, as well as the NH4+ concentrations of up to 0.98 ± 0.10 mg/L, NO2 of up to 24 ± 1 mg/L and NO3 of up to 20 ± 1 mg/L for water samples.  相似文献   

14.
A gas chromatography with ion trap mass spectrometry method has been developed and validated for the analysis of 27 polar organic compounds in atmospheric aerosols. The target analytes were low‐molecular‐weight carboxylic acids and methoxyphenols, as relevant markers of source emissions and photochemical processes of organic aerosols. The operative parameters were optimized in order to achieve the best sensitivity and selectivity for the analysis. In comparison with the previous gas chromatography with mass spectrometry procedure based on single ion monitoring detection, the tandem mass spectrometry technique increased the analytical sensitivity by reducing detection limits for standard solutions from 1–2.6 to 0.1–0.4 ng/μL ranges (concentrations in the injected solution). In addition, it enhanced selectivity by reducing matrix interferences and chemical noise in the chromatogram. The applicability of the developed method in air quality monitoring campaigns was effectively checked by analyzing environmental samples collected in the Po Valley (Northern Italy) in different seasons. The obtained results indicate that the ion trap mass spectrometer may be an ideal alternative to high‐resolution mass spectrometers for the user‐friendly and cost‐effective determination of a wide range of molecular tracers in airborne particulate matter.  相似文献   

15.
为精准防控大气降尘污染,提供其重金属检测方法。重点考察了样品前处理中混合酸体系选择和最佳酸用量比对实验。在最优条件下建立了混合酸(硝酸、氢氟酸、盐酸和高氯酸)湿法消解大气降尘样品和电感耦合等离子体质谱仪进行7种重金属(铊、铅、镉、铬、铜、锌和镍)含量测试的实验方法。实验结果显示7种重金属在一定的浓度范围内线性关系好,线性系数均大于0.999,7种重金属方法检出限为0.02 mg/kg~2.0 mg/kg,实际样品6次测定相对标准偏差为1.1 %~5.7 %,加标回收回收率为87.7 %~108.9 %。该方法经济环保、准确快捷,可作为大气沉降重金属检测参考方法。  相似文献   

16.
The measurements of dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) in seawater are key in global change and coastal eutrophication studies. Nowadays, the high-temperature combustion (HTC) technique is a widely used method for DOC and TDN analysis. However, uncertainties exist about the operation of the catalyst in the conversion process of DOC and TDN in the HTC method. In this study, five different ‘catalyst’ materials were tested for their blanks, calibration slopes, and conversion efficiency of DOC and TDN using the Shimadzu TOC 5000A total organic carbon analyser coupled to a Sievers NCD 255 nitrogen chemiluminescence detector. The materials included four metallic catalysts (Shimadzu and Johnson 0.5% Pt–alumina, 13% Cu(II)O–alumina, 0.5% Pd–alumina) and quartz beads. The results indicated that DOC blank signals for the HTC approach using metallic catalysts with an alumina support are higher compared with quartz beads, as a result of the amphoteric nature of the alumina. However, the slopes of the standard calibration graphs were lowest for DOC and TDN determinations on the quartz beads. The DOC recoveries for the metallic catalysts were close to 100% for all compounds tested, with the exception of ammonium pyrrolidine dithiocarbamate. Using quartz beads, poor recoveries were obtained for a range of organic compounds, including the commonly used calibration compounds potassium hydrogen phthalate and glycine. The TDN recoveries for all compounds were typically >90%, with the exception of NaNO2. Furthermore, analysis using the CuO–alumina and Pd–alumina catalysts and quartz beads showed low recoveries for NH4Cl. This study showed that catalyst performance should be verified on a regular basis using model compounds and blank checks made during every run, and that the Shimadzu 0.5% Pt–alumina material was an efficient catalyst for DOC and TDN analyses using the coupled total organic carbon–nitrogen chemiluminescence detector (TOC-NCD) analyser.  相似文献   

17.
A method for the determination of polymer additives like antioxidants, UV absorbers and processing stabilizers using liquid chromatography (LC) coupled with atmospheric pressure photoionization mass spectrometry (APPI-MS) is presented. Ion source parameters were optimized regarding temperatures, gas flow rates, and voltages applied. Detection limits were determined using APPI with or without dopant and were compared with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Differences between APPI, ESI and APCI are pointed out and the effect of the dopant toluene and acetone is discussed. The optimized method yielded detection limits between 0.001 mg L−1 and 0.022 mg L−1 for 15 different analytes. Linear calibration plots could be obtained for all solutes over a wide concentration range showing satisfying repeatability with standard deviations of peak areas between 3.4% and 7.6%. The results indicate that the developed method can be regarded as suitable for the quantitative determination of polymer additives even at low concentration levels.  相似文献   

18.
The use of ion chromatography (IC) in conjunction with ultrasonic extraction is described for the routine analysis of water-soluble major inorganic ions and organic acids in atmospheric fine particles (PM2.5). Both the extraction method and the IC analysis were validated using NIST SRM 1648 (urban particulate matter). In addition, the reliability of the IC method was established by intercomparison of results obtained with those from suitable alternative analytical techniques (atomic absorption spectrometry (AAS), proton-induced X-ray emission (PIXE) spectrometry, and UV-Visible spectrophotometry). The validated IC method was successfully applied for field monitoring of PM2.5 particles collected in Singapore over an extended period of time. The IC analysis revealed that the concentrations of individual ions were in the order, SO42− > NH4+ > NO3 > Na+ > K+ > Cl, respectively. Among the major ionic components, SO42− contributed 50% to the measured water-soluble aerosol mass followed by NH4+ (16.5%) and NO3 (9.0%). The cations Na+, K+, Mg2+, and Ca2+ accounted for 24% of the total water-soluble mass. The IC analysis was performed to quantify the organic acids, which typically account for a small fraction of water-soluble organic compounds in PM2.5. Oxalate was found to be the dominant species among the organic acids measured in this work.  相似文献   

19.
Liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization was used for the determination of polycyclic aromatic hydrocarbon derivatives, the oxygenated polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons, formed in asphalt fractions. Two different methods have been developed for the determination of five oxygenated and seven nitrated polycyclic aromatic hydrocarbons that are characterized by having two or more condensed aromatic rings and present mutagenic and carcinogenic properties. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all compounds. The detection limits of the methods ranged from 0.1 to 57.3 μg/L for nitrated and from 0.1 to 6.6 μg/L for oxygenated derivatives. The limits of quantification were in the range of 4.6–191 μg/L for nitrated and 0.3–8.9 μg/L for oxygenated derivatives. The methods were validated against a diesel particulate extract standard reference material (National Institute of Standards and Technology SRM 1975), and the obtained concentrations (two nitrated derivatives) agreed with the certified values. The methods were applied in the analysis of asphalt samples after their fractionation into asphaltenes and maltenes, according to American Society for Testing and Material D4124, where the maltenic fraction was further separated into its basic, acidic, and neutral parts following the method of Green. Only two nitrated derivatives were found in the asphalt sample, quinoline and 2‐nitrofluorene, with concentrations of 9.26 and 2146 mg/kg, respectively, whereas no oxygenated derivatives were detected.  相似文献   

20.
Abstract

As part of a project investigating the air-water exchange of nutrients and inorganic micropollutants to the North Sea, the atmospheric deposition of nutrients and trace metals in their different compositions and via various pathways was investigated. Intensive sampling campaigns were organised on the research vessel Belgica (ns 21/98 campaign from September 28 to October 1, 1998 and ns 10/99 campaign from April 19 to 23, 1999), at a sampling station near the Belgian coast (Knokke-Heist) and at the University campus of Antwerp. Simulation work and remobilisation experiments were carried out to obtain a general view of the kinetics of solubilisation of the constituents under investigation. Sample treatment requires a leaching system with a quantitative recovery of the species of interest in the leaching solution within a reasonably short period of time (30 min).

For this reason, a re-circulation leaching system was developed, tested, optimised and compared with a more accepted ultrasound leaching method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号