Molecularly imprinted polymer gel film on the gold substrate of a chip was prepared with minute amount of cross-linker for the fabrication of a surface plasmon resonance (SPR) sensor sensitive to 3,3′-dichlorobenzidine. The molecularly imprinted gel film was anchored on a gold chip by a surface-bound photo-radical initiator. The sensing of 3,3′-dichlorobenzidine is based on responsive shrinkage of the imprinted polymer gel film that is triggered by target binding. This change can improve the responsiveness of the imprinted SPR sensor to 3,3′-dichlorobenzidine. The molecularly imprinted polymer gel film was characterized with contact angle measurements, electrochemical impedance spectroscopy, cyclic voltammogram, swelling measurements and atomic force microscopy. The changes of SPR spectroscopy wavenumber shifts revealed that the imprinted gel sensing film can ‘memorize’ the binding of 3,3′-dichlorobenzidine compared to non-imprinted one. The imprinted gel-SPR sensor showed a linear response in the range of 9.0 × 10−12 to 5.0 × 10−10 mol L−1 (R2 = 0.9998) for the detection of 3,3′-dichlorobenzidine, and it also exhibited high selectivity to 3,3′-dichlorobenzidine compared to its structurally related analogues. We calculated the detection limits to be 0.471 ng L−1 for tap water and 0.772 ng kg−1 for soil based on a signal to noise ratio of 3. The method showed good recoveries and precision for the samples spiked with 3,3′-dichlorobenzidine. This suggest that the imprinted gel-SPR sensing method can be used as a promising alternative for the detection of 3,3′-dichlorobenzidine.  相似文献   

2.
Hu YF  Zhang ZH  Zhang HB  Luo LJ  Yao SZ 《Talanta》2011,84(2):305-313
A sensitive and selective electrochemical sensor based on a polyaniline modified carbon electrode for the determination of l-phenylalanine has been proposed by utilizing β-cyclodextrin (β-CD) incorporated multi-walled carbon nanotube (MWNT) and imprinted sol-gel film. The electrochemical behavior of the sensor towards l-phenylalanine was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometric i-t curve. The surface morphologies of layer-by-layer assembly electrodes were displayed by scanning electron microscope (SEM). The response mechanism of the imprinted sensor for l-phenylalanine was based on the inclusion interaction of β-CD and molecular recognition capacity of the imprinted film for l-phenylalanine. A linear calibration plot was obtained covering the concentration range from 5.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.0 × 10−9 mol L−1. With excellent sensitivity, selectivity, stability, reproducibility and recovery, the electrochemical imprinted sensor was used to detect l-phenylalanine in blood plasma samples successfully.  相似文献   

3.
A novel voltammetric sensor for O,O-dimethyl-(2,4-dichlorophenoxyacetoxyl)(3′-nitrophenyl)methinephosphonate (Phi-NO2) based on molecularly imprinted polymer (MIP) film electrode is constructed by using sol-gel technology. The sensor responds linearly to Phi-NO2 over the concentration range of 2.0 × 10−5 to 1.0 × 10−8 mol L−1 and the detection limit is 1.0 × 10−9 mol L−1 (S/N = 3). This sensor provides an efficient way for eliminating interferences from coexisting substances in the solution. The high sensitivity, selectivity and stability of the sensor demonstrates its practical application for a simple and rapid determination of Phi-NO2 in cabbage samples.  相似文献   

4.
By using a molecularly imprinted polymer (MIP) as a recognition element, the design and construction of a high selective voltammetric sensor for para-nitrophenol was formed. Para-nitrophenol selective MIP and a non-imprinted polymer (NIP) were synthesized, and then used for carbon paste (CP) electrode preparation. The MIP-CP electrode showed greater recognition ability in comparison to the NIP-CP. It was shown that electrode washing after para-nitrophenol extraction led to enhanced selectivity, without noticeably decreasing the sensitivity. Some parameters affecting sensor response were optimized and a calibration curve was plotted. A dynamic linear range of 8 × 10−9 to 5 × 10−6 mol L−1 was obtained. The detection limit of the sensor was calculated as 3 × 10−9 mol L−1. Thus, this sensor was used successfully for the para-nitrophenol determination in different water samples.  相似文献   

5.
An original electrochemical sensor based on molecularly imprinted conducting polymer (MICP) is developed, which enables the recognition of a small pesticide target molecule, atrazine. The conjugated MICP, poly(3,4-ethylenedioxythiophene-co-thiophene-acetic acid), has been electrochemically synthesized onto a platinum electrode following two steps: (i) polymerization of comonomers in the presence of atrazine, already associated to the acetic acid substituent through hydrogen bonding, and (ii) removal of atrazine from the resulting polymer, which leaves the acetic acid substituents open for association with atrazine. The obtained sensing MICP is highly specific towards newly added atrazine and the recognition can be quantitatively analyzed by the variation of the cyclic voltammogram of MICP. The developed sensor shows remarkable properties: selectivity towards triazinic family, large range of detection (10−9 mol L−1 to 1.5 × 10−2 mol L−1 in atrazine) and low detection threshold (10−7 mol L−1).  相似文献   

6.
A novel flow injection chemiluminescence (FI-CL) sensor for determination of sulfadiazine (SDZ) using core–shell magnetic molecularly imprinted polymers (MMIPs) as recognition element is developed. Briefly, a hydrophilic MMIPs layer was produced at the surface of Fe3O4@SiO2 magnetic nanoparticles (MNPs) via combination of molecular imprinting and reversible stimuli responsive hydrogel. And it provided the MMIPs with excellent adsorption capacity and rapid adsorption rate due to the imprinted sites mostly situated on the surface of MMIPs. Then the prepared SDZ-MMIPs were packed into flow cell to establish a novel FI-CL sensor. The sensor provided a wide linear range for SDZ of 4.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.54 × 10−7 mol L−1. And the relative standard deviation (RSD) for the determination of 1.0 × 10−6 mol L−1 SDZ was 2.56% (n = 11). The proposed method was applied to determine SDZ in urine samples and satisfactory results were obtained.  相似文献   

7.
A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be2+ determination. The complex of Be2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1, the ECL intensity had a linear relationship with the Be2+ concentrations, with the limit of detection of 2.35 × 10−11 mol L−1. This method was successfully used to detect Be2+ in real water samples.  相似文献   

8.
A newly designed molecularly imprinted polymer (MIP) was synthesized and successfully utilized as a recognition element of an amperometric sensor for 2,4-dichlorophenol (2,4-DCP) detection. The MIP with a well-defined structure could imitate the dehalogenative function of the natural enzyme chloroperoxidase for 2,4-DCP. Imprinted sensor was fabricated in situ on a glassy carbon electrode surface by drop-coating the 2,4-DCP imprinted microgel suspension and chitosan/Nafion mixture. Under optimized conditions, the sensor showed a linear response in the range of 5.0–100 μmol L−1 with a detection limit of 1.6 μmol L−1. Additionally, the imprinted sensor demonstrated higher affinity to target 2,4-DCP over competitive chlorophenolic compounds than non-imprinted sensor. It also exhibited good stability and acceptable repeatability. The proposed sensor could be used for the determination of 2,4-DCP in water samples with the recoveries of 96.2–111.8%, showing a promising potential in practical application.  相似文献   

9.
A novel method to improve the sensitivity of molecularly imprinted polymer sensors was developed. Oxytetracycline (OTC), which was selected as the template molecule, was first rebound to the imprinted cavities. Gold nanoparticles were then labeled with the amino groups of OTC molecules via electrostatic adsorption and non-covalent interactions. Copper ions were catalytically reduced by the gold nanoparticles, and copper was deposited onto the electrode. The deposited copper was electrochemically dissolved, and its oxidative currents were recorded by differential pulse voltammetry (DPV). OTC could be determined indirectly within the concentration range of 3.0 × 10−10 to 1.5 × 10−7 mol L−1 with a detection limit of 6.8 × 10−11 mol L−1.  相似文献   

10.
Wang Y  Tang J  Luo X  Hu X  Yang C  Xu Q 《Talanta》2011,85(5):2522-2527
In this work, a kojic acid electrochemical sensor, based on a non-covalent molecularly imprinted polymer (MIP) modified electrode, had been fabricated in the lab-on-valve system. The sensitive layer was synthesized by cyclic voltammetry using o-phenylenediamine as the functional monomer and kojic acid as the template. The template molecules were then removed from the modified electrode surface by washing with NaOH solution. Differential pulse voltammetry method using ferricyanide as probe was applied as the analytical technique, after extraction of kojic acid on the electrode. Chemical and flow parameters associated with the extraction process were investigated. The response recorded with the imprinted sensor exhibited a response in a range of 0.01-0.2 μmol L−1 with a detection limit of 3 nmol L−1. The interference studies showed that the MIP modified electrode had excellent selectivity. Furthermore, the proposed MIP electrode exhibited good sensitivity and low sample/reagent consumption, and the sensor could be applied to the determination kojic acid in cosmetics samples.  相似文献   

11.
A new method in which a nano optical sensor for diagnosis of different diseases of seminal vesicle and sexual gland was prepared. The working principle of the method depends on the determination of the fructose concentration in semen of different patients by using nano optical sensor thin film Sm-doxycycline doped in sol–gel matrix. The assay is based on the quenching of the characteristic emission bands of Sm3+ present in silica doped Sm-doxycycline nanooptode thin film by different fructose concentrations in acetonitrile at λex = 400 nm. This method was optimized for parameters, such as, solvent effect, operational stability, shelf life and interference parameters. Good and reproducible linearity (1 × 10−9 – 5.0 × 10−5 mol L−1) with a detection limit of 9.0 × 10−10 mol L−1 and quantification limit of detection (LOQ) 2.7 × 10−9 mol L−1 were obtained. Seminal fructose determination in different patient samples after appropriate dilutions confirmed the reliability of this technique. The method was successfully applied for routine fructose monitoring in human semen samples of different cases such as; obstructive and non-obstructive azoospermia, inflammation of male accessory glands, atrophy of seminal vesicle, congenital vas deferens and retrograde ejaculation.  相似文献   

12.
A sensitive molecularly imprinted electrochemical sensor was developed for selective detection of streptomycin by combination of mercaptoacetic acid-modified PbS nanoparticles with Au-coated Fe3O4 magnetic nanoparticles dispersed multi-walled carbon nanotubes doped chitosan film. The imprinted sensor was fabricated onto the Au electrode via stepwise modification of nanocomposites and an electrodeposited thin film of molecularly imprinted polymers via sol–gel technology. The morphologies and electrochemical behaviors of the imprinted sensor were characterized by scanning electron microscope, cyclic voltammetry, and differential pulse voltammetry, respectively. The prepared sensor showed very high recognition ability and selectivity for streptomycin. Under optimal conditions, the imprinted sensor displayed good electrocatalytic activity to the redox of streptomycin. And the differential voltammetric anodic peak current was linear to the logarithm of streptomycin concentration in the range from 1.0 × 10−6 to 1.0 × 10−3 mol L−1, and the detection limit obtained was 1.5 × 10−9 mol L−1. This proposed imprinted sensor was used successfully for streptomycin determination in different injection solution samples.  相似文献   

13.
A new piezoelectric quartz crystal (PQC) sensor using molecularly imprinted polymer (MIP) as sensing material has been developed for fast and onsite determination of pirimicarb in contaminated vegetables. Three MIPs particles have been prepared by conventional bulk polymerization (MIP-B) and precipitation polymerization in either acetonitrile (MIP-P1) or chloroform (MIP-P2). MIP-P2, with uniform spherical shape and mean diameter at about 50 nm, has shown the best performance as the sensing material for PQC sensor. The sensor fabricated with MIP-P2 can achieve a steady-state response within 5 min, a very short response time as compared to MIPs-coated PQC sensor reported in the literature. The sensor developed exhibits good selectivity (low response to those pesticides with similar structures to pirimicarb, such as atrazine, carbaryl, carbofuran and aldicarb) and high sensitivity to pirimicarb with a linear working range from 5.0 × 10−6 to 4.7 × 10−3 mol L−1 (following a regression equation (r = 0.9988) of −ΔF = 0.552 + 1.79 × 106 C), a repeatability (R.S.D., n = 5) of 4.3% and a detection limit (S/N = 3, n = 5) of 5 × 10−7 mol L−1. The MIP-coated PQC sensor developed is shown to provide a sensitive and fast method for onsite determination of pirimicarb in aqueous extract from contaminated vegetables with satisfactory recoveries from 96 to 103% and repeatability (R.S.D., n = 5) from 4.6 to 7.1% at pirimicarb concentrations ranging from 8.0 × 10−6 to 2.0 × 10−4 mol L−1.  相似文献   

14.
This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 × 10−3 mg L−1. The detection limit was 3.17 × 10−5 mg L−1. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 × 10−3 mg L−1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.  相似文献   

15.
A facile and efficient molecularly imprinted polymer (MIP) recognition element of electrochemical sensor was fabricated by directly electro-polymerizing monomer o-phenylenediamine (oPD) in the presence of template quinoxaline-2-carboxylic acid (QCA), based on one-step controllable electrochemical modification of poly(pyrrole)-graphene oxide-binuclear phthalocyanine cobalt (II) sulphonate (PPY-GO-BiCoPc) functional composite on glassy carbon electrode (GCE). The MIP film coated on PPY-GO-BiCoPc functional composite decorated GCE (MIP/PPY-GO-BiCoPc/GCE) was presented for the first time. The synergistic effect and electro-catalytic activity toward QCA redox of PPY-GO-BiCoPc functional composite were discussed using various contrast tests. Also, the effect of experimental variables on the current response such as, electro-polymerization cycles, template/monomer ratio, elution condition for template removal, pH of the supporting electrolyte and accumulation time, were investigated in detail. Under the optimized conditions, the proposed MIP sensor possessed a fast rebinding dynamics and an excellent recognition capacity to QCA, while the anodic current response of square wave voltammetry (SWV) was well-proportional to the concentration of QCA in the range of 1.0 × 10−8–1.0 × 10−4 and 1.0 × 10−4–5.0 × 10−4 mol L−1 with a low detection limit of 2.1 nmol L−1. The established sensor was applied successfully to determine QCA in commercial pork and chicken muscle samples with acceptable recoveries (91.6–98.2%) and satisfactory precision (1.9–3.5% of SD), demonstrating a promising feature for applying the MIP sensor to the measurement of QCA in real samples.  相似文献   

16.
A novel dual-function material was synthesized by anchoring a molecularly imprinted polymer (MIP) layer on CdTe/ZnS quantum dots (QDs) using a sol–gel with surface imprinting. The material exhibited highly selective and sensitive determination of ractopamine (RAC) through spectrofluorometry and solid-phase extraction (SPE) coupled with high performance liquid chromatography (HPLC). A series of adsorption experiments revealed that the material showed high selectivity, good adsorption capacity and a fast mass transfer rate. Fluorescence from the MIP-coated QDs was more strongly quenched by RAC than that of the non-imprinted polymer, which indicated that the MIP-coated QDs acted as a fluorescence sensing material could recognize RAC. In addition, the MIP-coated QDs as a sorbent was also shown to be promising for SPE coupled with HPLC for the determination of trace RAC in feeding stuffs and pork samples. Under optimal conditions, the spectrofluorometry and SPE-HPLC methods using the MIP-coated QDs had linear ranges of 5.00 × 10−10–3.55 × 10−7 and 1.50 × 10−10–8.90 × 10−8 mol L−1, respectively, with limits of detection of 1.47 × 10−10 and 8.30 × 10−11 mol L−1, the relative standard deviations for six repeat experiments of RAC (2.90 × 10−9 mol L−1) were below 2.83% and 7.11%.  相似文献   

17.
The design and construction of a highly selective voltammetric sensor for metronidazole by using a molecularly imprinted polymer (MIP) as recognition element were introduced. A metronidazole selective MIP and a nonimprinted polymer (NIP) were synthesized and then incorporated in the carbon paste electrodes (CPEs). The sensor was applied for metronidazole determination using cathodic stripping voltammetric method. The MIP-CP electrode showed very high recognition ability in comparison to NIP-CPE. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. Two dynamic linear ranges of 5.64 × 10−5 to 2.63 × 10−3 mg L−1 and 2.63 × 10−3 to 7.69 × 10−2 mg L−1 were obtained. The detection limit of the sensor was calculated as 3.59 × 10−5 mg L−1. This sensor was used successfully for metronidazole determination in biological fluids.  相似文献   

18.
The carbazole derivative, 9-ethyl-3-carbazylidene carbazole hydrazone (ECCH) with two conjugated carbazole rings have been applied as a fluorescence carrier for preparation of an iodine sensitive optical chemical sensor. The response of the sensor is based on quenching of the fluorescence of ECCH by iodine. The conjugated carbazole dimer based sensor shows a linear response toward iodine in the concentration range 1.0 × 10−6 to 1.0 × 10−4 mol L−1, with a detection limit of 8.0 × 10−7 mol L−1 at pH of 7.0. The effect of composition of the sensor membrane was studied, and the experimental conditions were optimized. Most commonly coexisting ions do not interfer with the iodine assay. The sensor shows sufficient repeatability, selectivity, operational lifetime of two months and a fast response of less then 50 s. The sensor has been used for determination of iodine in water samples.  相似文献   

19.
A novel optical sensor based on a redox reaction for the determination of iodide has been developed. The optode membrane is constructed by immobilization of methyltrioctylammonium chloride on triacetylcellulose polymer. The exchange of chloride as counter ion with iodate in the membrane changes the color to yellow, when it is placed in acidic solution of iodide. The sensor can readily be regenerated by 0.1 mol L−1 NaOH in less than 15 s. The optode has a linear range of 3.94 × 10−6 to 5.51 × 10−5 mol L−1 of iodide ions with a limit of detection 7.44 × 10−7 mol L−1. The relative standard deviation for eight replicate measurements of 3.94 × 10−6 and 1.57 × 10−5 mol L−1 of iodide was 2.83 and 1.38%, respectively. The sensor was successfully applied to the determination of iodide in tablet, powdered milk and urine samples.  相似文献   

20.
A ratiometric fluorescence sensor for Be2+ has been fabricated via alternate assembly of 2-(3,6-disulfo-8-hydroxynaphthylazo)-1,8-dihydroxynaphthalene-3,6-disulfonate (Beryllon II) and MgAl-LDH nanosheets on quartz substrates using the layer-by-layer (LBL) deposition technique. UV–vis absorption and the fluorescence emission spectroscopy indicate a stepwise and regular growth of the Beryllon II/LDH UTFs upon increasing deposition cycle. The film of Beryllon II/LDH possesses a periodic layered structure perpendicular to the substrate revealed by X-ray diffraction and scanning electron microscopy. Atomic force microscopy images show that the film surface is continuous and uniform. The Beryllon II/LDH UTFs display ratiometric fluorescence response for Be2+ with a linear response range in 1.0 × 10−7–1.9 × 10−6 mol L−1 and a detection limit of 4.2 × 10−9 mol L−1. Furthermore, the ratiometric sensor exhibits good repeatability, high stability (thermal, storage and mechanical) as well as excellent selectivity toward Be2+. XPS and Raman measurements demonstrate that the specific response of the sensor is attributed to the coordination between Be2+ and Beryllon II in the UTF. The Beryllon II/LDH UTFs in this work can be potentially used as a chemosensor for the detection of Be2+ in the environmental and biomedical field.  相似文献   