首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic method for the determination in human plasma of the recent noradrenergic and specific serotonergic antidepressant (NaSSA) mirtazapine and its two main metabolites, N-desmethylmirtazapine and 8-hydroxymirtazapine, has been developed. Fluorescence detection was used, exciting at λ = 290 nm and monitoring emission at λ = 370 nm. Separation was obtained by using a reversed-phase column (C8, 250 mm × 4.6 mm I.D., 5 μm) and a mobile phase composed of 75% aqueous phosphate buffer containing triethylamine at pH 3.0 and 25% acetonitrile. Melatonin was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with phenyl cartridges (100 mg, 1 mL). The calibration curves were linear over a working range of 5-150 ng mL−1 for mirtazapine and of 2.5-75.0 ng mL−1 for N-desmethylmirtazapine and 8-hydroxymirtazapine. The limit of quantitation (LOQ) was 2.5 ng mL−1 and the limit of detection (LOD) was 1.25 ng mL−1 for all analytes. The method was applied with success to plasma samples from depressed patients undergoing treatment with mirtazapine. Precision data, as well as accuracy results, were satisfactory and no interference from other drugs was found. Hence the method is suitable for therapeutic drug monitoring of mirtazapine and its metabolites in depressed patients’ plasma.  相似文献   

2.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

3.
An isocratic high-performance liquid chromatographic method has been developed for the measurement of serotonin, 5-hydroxyindolacetic and homovanillic acids in dried blood spots and in platelet poor and rich plasma samples. Analyses were carried out on a C18 reversed-phase column using a mobile phase composed of 13% methanol and 87% aqueous citrate buffer, containing octanesulfonic and ethylendiaminotetracetic acids. Coulometric detection was used, setting the guard cell at +0.100 V, the first analytical cell at −0.200 V and the second analytical cell at +0.400 V. For the pre-treatment of biological samples a novel solid-phase extraction procedure, based on mixed-mode reversed-phase – strong anion exchange Oasis cartridges, was implemented. Extraction yields of the analytes from all these matrices were satisfactory, being always higher than 89.0%. The calibration curve was linear over the on-column concentration range of 0.1–22.5 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and of 0.25–22.5 ng mL−1 for homovanillic acid. The sensitivity was good with a limit of detection of 0.05 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and 0.12 ng mL−1 for homovanillic acid. Results were also satisfactory in terms of precision, selectivity and accuracy. The analytical method was successfully applied to human platelet poor and rich plasma samples and to dried blood spots from volunteers and psychiatric patients.  相似文献   

4.
Fong BM  Tam S  Tsui SH  Leung KS 《Talanta》2011,83(3):1030-1036
A sensitive analytical method for the determination of tetrodotoxin (TTX) in urine and plasma matrices was developed using double solid phase extraction (C18 and hydrophilic interaction liquid chromatography) and subsequent analysis by HPLC coupled with tandem mass spectrometry. The double SPE sample cleanup efficiently reduced matrix and ion suppression effects. Together with the use of ion pair reagent in the mobile phase, isocratic elution became possible which enabled a shorter analysis time of 5.5 min per sample. The assay results were linear up to 500 ng mL−1 for urine and 20 ng mL−1 for plasma. The limit of detection and limit of quantification were 0.13 ng mL−1 and 2.5 ng mL−1, respectively, for both biological matrices. Recoveries were in the range of 75-81%. To eliminate the effect of dehydration and variations in urinary output, urinary creatinine-adjustment was made. TTX was quantified in eight urine samples and seven plasma samples from eight patients suspected of having TTX poisoning. TTX was detected in all urine samples, with concentrations ranging from 17.6 to 460.5 ng mL−1, but was not detected in any of the plasma samples. The creatinine-adjusted TTX concentration in urine (ranging from 7.4 to 41.1 ng μmol−1 creatinine) correlated well with the degree of poisoning as observed from clinical symptoms.  相似文献   

5.
A simple, rapid and sensitive high-performance liquid chromatography method was developed for the analysis of the sesquiterpene lactone 15-deoxygoyazensolide (LAC15-D) in rat plasma samples. The chromatographic separation was achieved on a LiChrospher® RP18 column using methanol:water (50:50, v/v) containing 0.6% acetic acid as mobile phase, at a flow rate of 0.7 mL min−1. UV detection was carried out at 270 nm. Phenytoin was used as internal standard. Prior to the analysis, the rat plasma samples were submitted to liquid-liquid extraction with dichloromethane. The mean absolute recoveries were 73% with R.S.D. values lower than 3.5. The method was linear over the 6.0-2000 ng mL−1 concentration range and the quantification limit was 6.0 ng mL−1. Within-day and between-day assay precision and accuracy were studied at three concentration levels (15, 300 and 480 ng mL−1) and were lower than 15%. The validated method was used to measure the plasmatic concentration of LAC15-D in rats that received a single intraperitoneal dose of 30 mg kg−1.  相似文献   

6.
Multi-element analysis of organic virgin olive oils from different Italian regions was carried out by inductively coupled plasma mass spectrometry (ICP-MS) aiming at developing a reliable method in the traceability of the origin of oils. The data were processed by means of the chemiometric approach of linear discriminant analysis (LDA) that allows classifying unknown samples after checking possible differentiation of samples of known origin.An external calibration curve was build for the quantitative analysis. The calibration curves for each element were linear in the range between 0.01 and 100 ng mL−1 and 0.2 to 2000 ng mL−1, the correlation coefficients were ranging between 0.996 and 0.999. Results from spike and recovery experiments at levels of 30 and 65 ng mL−1 were in the range of 91-119%, whereas the quantitation limits, based on 10 times standard deviation of the blank, were also in the range of 0.009-10.2 ng g−1, for almost all the elements.  相似文献   

7.
Li Y  Wei G  Hu J  Liu X  Zhao X  Wang X 《Analytica chimica acta》2008,615(1):96-103
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 μL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5 s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL−1 for BDE-28 and BDE-99, and 0.1-100 ng mL−1 for BDE-47 and BDE-209, respectively. Coefficients of correlation (r2) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL−1 for BDE-28 and BDE-99, and 100 ng mL−1 for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n = 5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL−1 (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL−1 were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.  相似文献   

8.
Sulfasalazine is an antibiotic used in the treatment of inflammatory bowel diseases. For the assessment of sulfasalazine in several biological matrices, an Enzyme-Linked Immunosorbent Assay (ELISA) method based on polyclonal antibodies was developed and characterized.The immunoassay showed a high sensitivity (IC50 = 0.51 ng mL−1) and specificity, a detection limit of 0.02 ng mL−1 and a dynamic range of 0.06-3.75 ng mL−1 (80-20% inhibition). The immunoassay performed well when it was applied to spiked plasma samples (from 0.5 to 2.0 ng mL−1) previously cleaned up by protein precipitation with methanol. Recoveries ranged from 83 to 119%, with a mean value of 99% (CV = 13%).Since sulfasalazine remaining of a treatment reaches the systemic circulation in unchanged form, the immunoassay can be applied to the determination of this pharmaceutical in human plasma in order to facilitate the control of the patients through the application of personal doses.  相似文献   

9.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   

10.
A simple, sensitive and accurate reverse phase high-performance liquid chromatographic (RP-HPLC) method with photo-diode array detector (PDA) was developed and validated for the determination of amphotericin B (AMB) in the rat plasma using a new internal standard (IS) α-naphthol. The plasma samples were subjected to protein precipitation with methanol prior to a HPLC analysis. Chromatographic separations were achieved on a Nucleosil® 100-5C18 (150 mm × 4.6 mm) column. The mobile phase consisted of acetonitrile and sodium acetate buffer (pH 4; 10 mM) in a gradient mode. Detection was carried out at a wavelength of 407 and 294 nm for AMB and IS, respectively. The retention times of AMB and IS were about 6.8 and 7.8 min, respectively. The calibration curve was linear in the range of 10-2000 ng mL−1 for AMB (r2 > 0.998). No significant matrix effect was observed on quantification of AMB or IS. At three quality control concentrations of 20, 500, and 2000 ng mL−1, the intra-day and inter-day relative standard deviation ranged from 1.13% to 4.91%. The limit of detection (LOD) was 5 ng mL−1 and the limit of quantification (LOQ) was 10 ng mL−1 for AMB in rat plasma. This method is simple, sensitive, rapid and does not require any extensive sample purification before injecting into HPLC.  相似文献   

11.
Liu R  Xing Z  Lv Y  Zhang S  Zhang X 《Talanta》2010,83(1):48-54
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions (197Au+) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3σ) of 0.1 ng mL−1 was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL−1 and a RSD of 8.1% (2.0 ng mL−1). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay.  相似文献   

12.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

13.
A new procedure was described with multiwalled carbon nanotubes as solid phase extraction packing material for the trace analysis of nicosulfuron, thifensulfuron and metsulfuron-methyl in water samples. The possible parameters influencing the enrichment were optimized and the optimal conditions were as followed: eluent, sample pH, flow rate and sample volume were acetonitrile containing 1% acetic acid, pH 3, 8 mL min−1 and 500 mL, respectively. Under the optimal chromatographic separation and SPE conditions, the linear range, detection limit (S/N = 3) and precision (R.S.D., n = 6) were 0.04-40 ng mL−1, 6.8 ng L−1 and 2.5% for nicosulfuron, 0.04-40 ng mL−1, 11.2 ng L−1 and 5.4% for thifensulfuron, 0.02-20 ng mL−1, 5.9 ng L−1, 2.1% for metsulfuron-methyl, respectively. The established method was well employed to determine nicosulfuron, thifensulfuron and metsulfuron-methyl in tap water, seawater, reservoir water and well water samples, and satisfactory results were obtained, the spiked recoveries in the range of 87.2-100.7%, 96.5-105.6% and 83.7-111.1% for them each, respectively.  相似文献   

14.
A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L−1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L−1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min−1. Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL−1 concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL−1. Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL−1) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer.  相似文献   

15.
In this work, a simple, rapid and sensitive sample pretreatment technique, dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD), has been developed to determine carbamate (carbaryl) and organophosphorus (triazophos) pesticide residues in water and fruit juice samples. Parameters, affecting the DLLME performance such as the kind and volume of extraction and dispersive solvents, extraction time and salt concentration, were studied and optimized. Under the optimum extraction conditions (extraction solvent: tetrachloroethane, 15.0 μL; dispersive solvent: acetonitrile, 1.0 mL; no addition of salt and extraction time below 5 s), the performance of the proposed method was evaluated. The enrichment factors for the carbaryl and triazophos were 87.3 and 275.6, respectively. The linearity was obtained in the concentration range of 0.1-1000 ng mL−1 with correlation coefficients from 0.9991 to 0.9999. The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.3 to 16.0 pg mL−1. The relative standard deviations (RSDs, for 10 ng mL−1 of carbaryl and 20 ng mL−1 of triazophos) varied from 1.38% to 2.74% (n = 6). The environmental water (at the fortified level of 1.0 ng mL−1) and fruit juice samples (at the fortified level of 1.0 and 5.0 ng mL−1) were successfully analyzed by the proposed method, and the relative recoveries of them were in the range of 80.4-114.2%, 89.8-117.9% and 86.3-105.3%, respectively.  相似文献   

16.
Ceren Yard?mc?  Alper Gürlek 《Talanta》2007,72(4):1416-1422
A novel, fast and simple liquid chromatographic method was developed and validated for the simultaneous determination of rosiglitazone and metformin in human plasma. The analysis was performed on a phenyl column (250 mm × 4.6 mm i.d., 5 μm) using a gradient method starting with mobile phase composed of acetonitrile:5 mM acetate buffer pH 5.5 (75:25, v/v). The flow rate was 1 mL min−1. UV detection was performed at 245 nm and verapamil was used as internal standard. The total run time was less than 10 min. Sample preparation included a simple protein precipitation step with acetonitrile. Validation experiments were performed to demonstrate stability, specificity, sensitivity, linearity, accuracy, precision and robustness. The limit of quantification was 100 ng mL−1 for rosiglitazone and 250 ng mL−1 for metformin. The extraction recoveries were 100.02-105.0% for rosiglitazone and 105.64-103.88% for metformin. The method was applied with success to plasma samples obtained from diabetic patients undergoing treatment with rosiglitazone and metformin.  相似文献   

17.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

18.
Zhuo SJ  Zheng H  Chen JL  Li DH  Wu YQ  Zhu CQ 《Talanta》2004,64(2):528-533
A new method was developed for determination of micro amounts of nucleic acids based on near-infrared (near-IR) fluorescence recovery, employing a two-reagent system which is composed of an anionic tetracarboxy aluminum phthalocyanine (AlC4Pc) and a cationic tetra-N-hexadecylpyridiniumyl porphyrin (TC16PyP). The fluorescence of the AlC4Pc, with the maximum emission wavelength at 701 nm, could be quenched by TC16PyP at its proper concentration, but recovered by adding nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. The calibration graphs are linear over the range of 1-200 ng mL−1 for fish sperm DNA (FS DNA) and 2-400 ng mL−1 for calf thymus DNA (CT DNA). The corresponding detection limits are 0.59 ng mL−1 for FS DNA and 0.82 ng mL−1 for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

19.
The increasing global adoption of genetically modified (GM) plant derivatives in animal feed has provoked a strong demand for an appropriate detection method to evaluate the existence of transgenic protein in animal tissues and animal by-products derived from GM plant fed animals. A highly specific and sensitive sandwich enzyme immunoassay for the surveillance of transgenic Cry1Ab protein from Bt-maize in the blood plasma of cows fed on Bt-maize was developed and validated according to the criteria of EU-Decision 2002/657/EC. The sandwich assay is based on immuno-affinity purified polyclonal antibody raised against Cry1Ab protein in rabbits. Native and biotinylated forms of this antibody served as capture antibody and detection antibody for the ELISA, respectively. Streptavidin-horseradish peroxidase conjugate and TMB substrate provided the means for enzymatic colour development.The immunoassay allowed Cry1Ab protein determination in bovine blood plasma in an analytical range of 0.4-100 ng mL−1 with a decision limit (CCα) of 1.5 ng mL−1 and detection capability (CCβ) of 2.3 ng mL−1. Recoveries ranged from 89 to 106% (mean value of 98%) in spiked plasma.In total, 20 plasma samples from cows (n = 7) fed non-transgenic maize and 24 samples from cows (n = 8) fed transgenic maize (collected before and, after 1 and 2 months of feeding) were investigated for the presence of the Cry1Ab protein. There was no difference amongst both groups (all the samples were below 1.5 ng mL−1; CCα). No plasma sample was positive for the presence of the Cry1Ab protein at CCα and CCβ of the assay.  相似文献   

20.
Akarm Karimi 《Talanta》2009,79(2):479-68
A rapid, simple, and sensitive headspace solid phase microextraction coupled to ion mobility spectrometry (HS-SPME-IMS) method is presented for analysis of the highly specific angiotensin-converting enzyme (ACE) inhibitor, captopril (CAP). Positive ion mobility spectra of CAP were acquired with an ion mobility spectrometer equipped with a corona discharge ionization source. Mass-to-mobility correlation equation was used to identify product ions. A dodecylsulfate-doped polypyrrole (PPy-DS) coating was used as a fiber for SPME. The results showed that PPy-DS based SPME fiber was suitable for successfully extracting CAP from human blood plasma and pharmaceutical samples. The HS-SPME-IMS method provided good repeatability (R.S.D.s < 4%) for aqueous and spiked plasma samples. The calibration graphs were linear in the range of 10-300 ng mL−1 (R2 > 0.99) and detection limits were 7.5 ng mL−1 for aqueous and 6.3 ng mL−1 for plasma blank samples. Finally, a standard addition calibration method was applied to HS-SPME-IMS technique for the analysis of blood plasma samples and tablets. Purpose method seemed to be suitable for the analysis of CAP in plasma samples as it is not time consuming (state total time from sample preparation to analysis), it required only small quantities of the sample, and no derivatization was required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏