首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 23 factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 μg kg−1, and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 μg kg−1. The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal.  相似文献   

2.
A simple and cost effective sample pre-treatment method, dispersive liquid–liquid microextraction (DLLME), has been developed for the extraction of six fluoroquinolones (FQs) from chicken liver samples. Clean DLLME extracts were analyzed for fluoroquinolones using liquid chromatography with diode array detection (LC-DAD). Parameters such as type and volume of disperser solvent, type and volume of extraction solvent, concentration and composition of phosphoric acid in the disperser solvent and pH were optimized. Linearity in the concentration range of 30–500 μg kg−1 was obtained with regression coefficients ranging from 0.9945 to 0.9974. Intra-day repeatability expressed as % RSD was between 4 and 7%. The recoveries determined in spiked blank chicken livers at three concentration levels (i.e. 50, 100 and 300 μg kg−1) ranged from 83 to 102%. LODs were between 5 and 19 μg kg−1 while LOQs ranged between 23 and 62 μg kg−1. All of the eight chicken liver samples obtained from the local supermarkets were found to contain at least one type of fluoroquinolone with enrofloxacin being the most commonly detected. Only one sample had four fluoroquinolone antibiotics (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin). Norfloxacin which is unlicensed for use in South Africa was also detected in three of the eight chicken liver samples analyzed. The concentration levels of all FQs antibiotics in eight samples ranged from 8.8 to 35.3 μg kg−1, values which are lower than the South African stipulated maximum residue limits (MRL).  相似文献   

3.
The application of sulfur microparticles as efficient adsorbents for the solid-phase extraction (SPE) and determination of trace amounts of 10 polycyclic aromatic hydrocarbons (PAHs) was investigated in sea water and wastewater samples using high performance liquid chromatography coupled with an ultraviolet detector (HPLC–UV). Parameters influencing the preconcentration of PAHs such as the amount of sulfur, solution flow rate and volume, elution solvent, type and concentration of organic modifier, and salt effect were examined. The results showed that at a flow rate of 10 mL min−1 for the sample solutions (100 mL), the PAHs could be adsorbed on the sulfur microparticles and then eluted by 2.0 mL of acetonitrile. For HPLC–UV analysis of extracted PAHs, the calibration curves were linear in the range of 0.05–80.0 μg L−1; the coefficients of determinations (r2) were between 0.9934 and 0.9995. The relative standard deviations (RSDs) for eight replicates at two concentration levels (0.5 and 4.0 μg L−1) of PAHs were lower than 7.3%, under optimized conditions. The limits of detection (LODs, <!-- no-mfc -->S/N<!-- /no-mfc --> = 3) of the proposed method for the studied PAHs were 0.007–0.048 μg L−1. The recoveries of spiked PAHs (0.5 and 4 μg L−1) in the wastewater and sea water samples ranged from 78% to 108%. The simplicity of experimental procedure, high extraction efficiency, short sample analysis, and using of low cost sorbent demonstrate the potential of this approach for routine trace PAH analysis in water and wastewater samples.  相似文献   

4.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0 mL of acetonitrile (as dispersive solvent) containing 30 μL 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 μg kg−1 for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 μg kg−1, respectively. The relative standard deviations (RSDs) for the extraction of 10 μg kg−1 of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method.  相似文献   

5.
This paper describes the development and validation of an analytical methodology to determine eight perfluorinated compounds (PFCs) in edible fish using pressurized liquid extraction (PLE) with water and solid-phase extraction (SPE) with an ion-exchanger as extraction and pre-concentration procedures, followed by liquid chromatography–quadrupole-linear ion trap mass spectrometry (LC–QqLIT–MS). The rapidity and effectiveness of the proposed extraction procedure were compared with those most commonly used to isolate PFCs from fish (ion-pairing and alkaline digestion). The average recoveries of the different fish samples, spiked with the eight PFCs at three levels (the LOQ, 10 and 100 μg kg−1 of each PFC), were always higher than 85% with relative standard deviation (RSD) lower than 17%. A good linearity was established for the eight PFCs in the range from 0.003–0.05 to 100 μg kg−1, with r > 0.9994. The limits of quantification (LOQs) were between 0.003 and 0.05 μg kg−1, which are well below those previously reported for this type of samples. Compared with previous methods, sample preparation time and/or LOQs are reduced. The method demonstrated its successful application for the analysis of different parts of several fish species. Most of the samples tested positive, mainly for perfluoropentanoic acid (PFPA), perfluorobutane sulfonate (PFBS) and perfluorooctanoic acid (PFOA) but other of the eight studied PFCs were also present.  相似文献   

6.
In this work, a rapid, simple and efficient homogeneous liquid–liquid microextraction via flotation assistance (HLLME-FA) method was developed based on applying low density organic solvents without no centrifugation. For the first time, a special extraction cell was designed to facilitate collection of the low-density solvent extraction in the determination of four polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). The effect of different variables on the extraction efficiency was studied simultaneously using experimental design. The variables of interest in the HLLME-FA were selected as extraction and homogeneous solvent volumes, ionic strength and extraction time. Response surface methodology (RSM) was applied to investigate the optimum conditions of all the variables. Using optimized variables in the extraction process, for all target PAHs, the detection limits, the precisions and the linearity of the method were found in the range of 14–41 μg L−1, 3.7–10.3% (RSD, n = 3) and 50–1000 μg L−1, respectively. The proposed method has been successfully applied to the analysis of four target PAHs in the water samples, and satisfactory results were obtained.  相似文献   

7.
This study compared four extraction methods for the simultaneous determination of tetracyclines, macrolides, quinolones, sulphonamides and anthelmintics (including benzimidazoles and avermectins) in eggs by ultra-high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Solvent extraction, solid-phase extraction (SPE), matrix solid-phase dispersion (MSPD) and modified QuEChERS procedure were compared in terms of recovery and number of veterinary drugs extracted. The solvent extraction procedure with a clean-up step provided better results than the other tested procedures. The QuEChERS procedure was simpler and faster, but extracted fewer compounds than solvent extraction. MSPD did not extract tetracyclines and quinolones, whereas macrolides and tetracyclines were not extracted when SPE was applied. The solvent extraction procedure was validated, obtaining recoveries ranging from 60% (sulfaquinoxaline) to 119% (levamisole) with repeatability values (expressed as relative standard deviations, RSDs) lower than 20% at two concentration levels (10 and 100 μg kg−1), except for erythromycin, emamectin and ivermectin that showed RSD values close to 25% at 10 μg kg−1. Limits of quantification (LOQs) were always equal or lower than 5 μg kg−1. Finally the method was applied to egg samples, and erythromycin, enrofloxacin, difloxacin, thiabendazole, emamectin and fenbendazole were detected in four samples.  相似文献   

8.
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography–mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500 μg L−1 could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12 μg L−1 for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237 μg L−1 (3,5-DCP) to 0.3623 μg L−1 (2,3,6-TCP).  相似文献   

9.
A low toxic dispersive liquid–liquid microextraction (LT-DLLME) combined with gas chromatography–mass spectrometry (GC–MS) had been developed for the extraction and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water samples. In normal DLLME assay, chlorosolvent had been widely used as extraction solvents; however, these solvents are environmental-unfriendly. In order to solve this problem, we proposed to use low toxic bromosolvent (1-bromo-3-methylbutane, LD50 6150 mg/kg) as the extraction solvent. In this study we compared the extraction efficiency of five chlorosolvents and thirteen bromo/iodo solvents. The results indicated that some of the bromo/iodo solvents showed better extraction and had much lower toxicity than chlorosolvents. We also found that propionic acid is used as the disperser solvent, as little as 50 μL is effective. Under optimum conditions, the range of enrichment factors and extraction recoveries of tap water samples are ranging 372–1308 and 87–105%, respectively. The linear range is wide (0.01–10.00 μg L−1), and the limits of detection are between 0.0003 and 0.0078 μg L−1 for most of the analytes. The relative standard deviations (RSD) for 0.01 μg L−1 of PAHs in tap water were in the range of 5.1–10.0%. The performance of the method was gauged by analyzing samples of tap water, sea water and lake water samples.  相似文献   

10.
In the present study, a new and versatile liquid-phase microextraction method is described. This method requires very simple and cheap apparatus and also a small amount of organic solvent. Eight microliters of 1-undecanol was delivered to the surface of solution containing analytes and solution was stirred for a desired time. Then sample vial was cooled by inserting it into an ice bath for 5 min. The solidified 1-undecanol was transferred into a suitable vial and immediately melted; then, 2 μL of it was injected into a gas chromatograph for analysis.Some polycyclic aromatic hydrocarbons (PAHs) were used as model compounds for developing and evaluating of the method performance. Analysis was carried out by gas chromatography/flame ionization detection (GC/FID).Several factors influencing the microextraction efficiency, such as the nature and volume of organic solvent, the temperature and volume of sample solution, stirring rate and extraction time were investigated and optimized. The applicability of the technique was evaluated by determination of trace amounts of PAHs in environmental samples. Under the optimized conditions, the detection limits (LOD) of the method were in the range of 0.07-1.67 μg L−1 and relative standard deviations (R.S.D.) for 10 μg L−1 PAHs were <7%. A good linearity (r2 > 0.995) in a calibration range of 0.25-300.00 μg L−1 was obtained. After 30 min extraction duration, enrichment factors were in the range of 594-1940. Finally, the proposed method was applied to the determination of trace amounts of PAHs in several real water samples, and satisfactory results were resulted. Since very simple devices were used, this new technique is affordable, efficient, and convenient for extraction and determination of low concentrations of PAHs in water samples.  相似文献   

11.
Supramolecular solvents are here proposed firstly as extractants in solid sample microextractions. The approach was evaluated by extracting flumequine (FLU) and oxolinic acid (OXO), two widely used veterinary medicines, from fish and shellfish muscle using a supramolecular solvent made up of decanoic acid (DeA) reverse micelles. The antibiotics were extracted in a single step (∼15 min), at room temperature, using 400 μL of solvent. After centrifugation, an aliquot of the extract was directly analyzed by liquid chromatography and fluorescence, without the need of clean-up or solvent evaporation. Contrary to the previously reported methods, both OXO and FLU were quantitatively extracted from fish and shellfish, independently of sample composition. The high extraction efficiencies observed for these antibiotics were a consequence of their amphiphilic character which resulted in the formation of DeA-OXO and DeA-FLU mixed aggregates. The quality parameters of this quantitative method including sensitivity, linearity, selectivity, repeatability, trueness, ruggedness, stability, decision limit and detection capability were evaluated according to the 2002/657/EC Commission Decision. Quantitation limits in the different samples analyzed (salmon, sea trout, sea bass, gilt-head bream, megrim and prawns) ranged between 6.5 and 22 μg kg−1 for OXO and, 5 and 15 μg kg−1 for FLU. These limits were far below the current maximum residue limits (MRLs) set by the European Union (EU) (i.e. 100 and 600 μg kg−1, for OXO and FLU, respectively). The trueness of the method was determined by analyzing a Certified Reference Material (CMR, BCR®-725) consisting of a lyophilised salmon tissue material. Recoveries for fortified samples (50–100 μg kg−1 of OXO and 50–600 μg kg−1 of FLU) and their relative standard deviations were in the intervals 99–102% and 0.2–5%, respectively. The repeatability, expressed as relative standard deviation, was 3.6% for OXO and 2.3% for FLU ([OXO] = [FLU] = 200 μg kg−1 and n = 11).  相似文献   

12.
A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus and pyrethroid pesticides in water by gas chromatography (GC) with flame ionization detection (GC-FID). The significant parameters that affect SDME performance, such as the selection of microextraction solvent, solvent volume, extraction time, and stirring rate, were studied and optimized using a tool screening factorial design. The limits of detection (LODs) in water for the four investigated compounds were between 0.3 and 3.0 μg L−1, with relative standard deviations ranging from 7.7 to 18.8%. Linear response data were obtained in the concentration range of 0.9-6.0 μg L−1 (λ-cyhalothrin), 3.0-60.0 μg L−1 (methyl parathion), 9.0-60.0 μg L−1 (ethion), and 9.0-30.0 μg L−1 (permethrin), with correlation coefficients ranging from 0.9337 to 0.9977. The relative recoveries for the spiked water ranged from 73.0 to 104%. Environmental water samples (n = 26) were successfully analyzed using the proposed method and methyl parathion presented concentration up to 2.74 μg L−1. The SDME method, coupled with GC-FID analysis, provided good precision, accuracy, and reproducibility over a wide linear range. Other highlights of the method include its ease of use and its requirement of only small volumes of both organic solvent and sample.  相似文献   

13.
A method was developed for simultaneous determination of residues of 17 sex hormones in egg products. Target compounds were extracted from samples with methanol in an ultrasonic bath, effectively separated from lipids in the extracts by ZnCl2 depositing filtration and purified using a C18 solid-phase extraction (SPE) and followed by NH2 SPE cartridge. The analytes were quantified by liquid chromatography using a BEH C18 column coupled to an electrospray ionization tandem mass spectrometer (LC-ESI-MS/MS) operating in negative mode for estrogens and in positive multiple reaction monitoring mode for androgens. The parameters of the mass spectrometer and the composition of mobile phase and additives were also optimized to enhance detection sensitivity. Average recoveries of the target compounds varied from 70.0% to 121.0% with relative standard deviations ranging from 2.3% to 11.2% at two fortification levels. The limits of detection (LOD) of the method were from 0.002 μg kg−1 to 0.23 μg kg−1 and the limits of quantification (LOQ) were in the range of 0.007-0.76 μg kg−1.  相似文献   

14.
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C18 cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L−1 and limits of quantification (LOQs) from 0.003 to 1.452 μg L−1. For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L−1 and LOQs ranged from 0.011 to 3.494 μg L−1. Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L−1, whereas methiocarb sulfoxide was detected at trace levels in two samples.  相似文献   

15.
A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) was investigated using gas chromatography–mass spectrometry (GC/MS). In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step. After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions, good linearity was observed in the range of 0.1–1000 μg L−1 and 0.01–100 μg L−1 with the limits of detection (LOD) of 0.03 μg L−1 and 0.002 μg L−1 for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 ± 0.16 μg L−1 and 0.037 ± 0.001 μg L−1, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88.3–106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples.  相似文献   

16.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

17.
Due to the different physico-chemical properties of phenols, the development of a methodology for the simultaneous extraction and determination of phenolic compounds belonging to several families, such as chlorophenols (CPs), alkylphenols (APs), nitrophenols (NTPs) and cresols is difficult. This study shows the development and validation of a method for the analysis of 13 phenolic compounds (including CPs, APs, NTPs and cresols) in agricultural soils. For this purpose, a quick, easy, cheap, effective, rugged and safe (QuEChERS)-based procedure was developed, validated and applied to the analysis of real samples. A derivatization step prior to the final determination by gas chromatography (GC) coupled to a triple quadrupole analyzer operating in tandem mass spectrometry (QqQ-MS/MS) was performed by using acetic acid anhydride (AAA) and pyridine (Py). The optimized procedure was validated, obtaining average extraction recoveries in the range 69–103% (10 μg kg−1), 65–98% (50 μg kg−1), 76–112% (100 μg kg−1) and 76–112% (300 μg kg−1), with precision values (expressed as relative standard deviation, RSD) ≤ 22% (except for 4-chlorophenol) involving intra-day and inter-day studies. Furthermore, 15 real soil samples were analyzed by the proposed method in order to assess its applicability. Some phenolic compounds (e.g. 2,4,6-trichlorophenol or 4-tert-octylphenol) were found in the samples at trace levels (<10 μg kg−1).  相似文献   

18.
This study proposes the dual electromembrane extraction followed by high performance liquid chromatography for selective separation-preconcentration of Cr(VI) and Cr(III) in different environmental samples. The method was based on the electrokinetic migration of chromium species toward the electrodes with opposite charge into the two different hollow fibers. The extractant was then complexed with ammonium pyrrolidinedithiocarbamate for HPLC analysis. The effects of analytical parameters including pH, type of organic solvent, sample volume, stirring rate, time of extraction and applied voltage were investigated. The results showed that Cr(III) and Cr(VI) could be simultaneously extracted into the two different hollow fibers. Under optimized conditions, the analytes were quantified by HPLC instrument, with acceptable linearity ranging from 20 to 500 μg L−1 (R2 values ≥ 0.9979), and repeatability (RSD) ranging between 9.8% and 13.7% (n = 5). Also, preconcentration factors of 21.8–33 that corresponded to recoveries ranging from 31.1% to 47.2% were achieved for Cr(III) and Cr(VI), respectively. The estimated detection limits (S/N ratio of 3:1) were less than 5.4 μg L−1. Finally, the proposed method was successfully applied to determine Cr(III) and Cr(VI) species in some real water samples.  相似文献   

19.
A multi-residue method for the determination of organochlorine pesticides in fish feed samples was developed and optimized. The method is based on a cleanup step of the extracted fat, carried out by liquid–liquid extraction on diatomaceous earth cartridge with n-hexane/acetonitrile (80/20, v/v) followed by solid phase extraction (SPE) with silica gel–SCX cartridge, before the identification and quantification of the residues by gas chromatography–triple quadrupole tandem spectrometry (GC–MS/MS). Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), for each pesticide were determined. Instrumental LODs ranged from 0.01 to 0.11 μg L−1, LOQs were in the range of 0.02–0.35 μg L−1, and calibration curves were linear (r2 > 0.999) in the whole range of explored concentrations (5–100 μg L−1). Repeatability values were in the range of 3–15%, evaluated from the relative standard deviation of six samples spiked at 100 μg kg−1 of fat, and in compliance with that derived by the Horwitz's equation. No matrix effects or interfering substances were observed in fish feed analyses. The proposed method allowed high recoveries (92–116%) of spiked extracted fat samples at 100 μg kg−1, and very low LODs (between 0.02 and 0.63 μg kg−1) and LOQs (between 0.05 and 2.09 μg kg−1) determined in fish feed samples.  相似文献   

20.
A low temperature microwave-assisted extraction method (MAE) is reported for the analysis of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter (PM). The main parameters affecting the extraction efficiency (choice of extractants, microwave power, and extraction time) were investigated and optimized. The optimized procedure requires a 20 ml mixture of acetone:n-hexane (1:1) for extraction of PAHs in PM at 150 W of microwave energy (20 min extraction time). Clean-up of MAE extracts was not found to be necessary. The optimized method was validated using two different SRM (1648-urban particulate matter and 1649a, urban dust). The results obtained are in good agreement with certified values. PAHs recoveries for both reference materials were between 79 and 122% with relative standard deviation ranging from 3 to 21%. Detection limits were determined based on blank determination using two kinds of quartz filter substrates (n = 10), which ranged from 0.001 (0.03) ng m−3 (pg/μg) for B(k)Ft to 1.119 (37.3) for Naph in ng m−3 (pg/μg), respectively. The repeatability and day-to-day reproducibility obtained in this study were in the range of 4-16 and 3-25% for spiked standards and SRM 1649, respectively. The optimized and validated MAE technique was applied to the extraction of PAHs from a set of real world PM samples collected in Singapore. The sum of particulate-bound PAHs in outdoor PM ranged from 1.05 to 3.45 ng m−3 while that in indoor PM (cooking emissions) ranged from 27.6 to 75.7 ng m−3, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号