1.
In this study, a specific and sensitive LC–MS/MS method for the simultaneous analysis of type‐B trichothecenes (deoxynivalenol, 3‐acetyldeoxynivalenol, and 15‐acetyldeoxynivalenol) and the de‐epoxy metabolite of deoxynivalenol (de‐epoxy‐deoxynivalenol) in chicken muscle, liver, kidney, and fat tissues was developed and validated. The method involved an extraction step using ethyl acetate, followed by the evaporation of the supernatant, which was further purified by an Oasis HLB SPE cartridge (Waters, Milford, MA, USA). Chromatographic separation was performed on a C18 column by detection with MS in multiple‐reaction monitoring mode and using a gradient elution program with 0.1% formic acid in water and methanol. The correlation coefficients (r) for each calibration curve were >0.99 within the experimental concentration range. The extraction recoveries ranged from 73.7 to 106.4%, with intraday and interday RSD < 11.6% at three levels of concentrations of 2, 10, and 100 μg/kg. The decision limits and the detection capabilities of the analytes in the chicken tissues ranged from 0.16 to 0.92 and 0.68 to 2.07 μg/kg, respectively. The results demonstrated the applicability of this sensitive procedure to the determination of trichothecenes in chicken tissue samples.  相似文献   

2.
Hollosi  Laszlo  Mittendorf  Klaus  Senyuva  Hamide Z. 《Chromatographia》2012,75(23):1377-1393

This paper describes an on-line sample preparation method for the simultaneous determination of 48 pesticides in grapes, baby food and wheat flour matrices. Target pesticides were selected to represent a wide variety of chemical structures and three typical matrices were selected. Turbulent flow chromatography was applied for on-line sample cleanup directly coupled to LC–MS/MS. The aim of the method was to reduce total analysis time, eliminate manual laboratory work, provide clean extracts and achieve reproducible results. Single laboratory method validation was conducted establishing limits of detection between 0.8 and 6.0 ng g−1 for baby food, and 0.8–10.3 ng g−1 for other matrices. Within-day precision values varied between 4 and 18 %, while between-day precisions were in the range 5–22 %. Method recovery ranged from 67 to 124 %, and method accuracy was demonstrated by analysis of external quality control samples. The method was also tested on 24 different survey samples from both bio and organic origin. The method was shown to be convenient, fast and fit for purpose in meeting regulatory requirements for pesticide residue monitoring.

  相似文献   

3.
A speedy and selective ultra‐HPLC‐MS/MS method for simultaneous determination of deoxynivalenol (DON), 3‐acetyldeoxynivalenol (3‐ADON), 15‐ADON, nivalenol and fusarenon X in traditional Chinese medicines (TCMs) was developed. The method was based on one‐step sample cleanup using reliable homemade cleanup cartridges. A linear gradient mobile‐phase system, consisting of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90:10, v/v) at a flow rate of 0.4 mL/min, and an Acquity UPLC HSS T3 column (100 mm×2.1 mm, 1.8 μm) were employed to obtain the best resolution of the target analytes. [13C15]–DON was used as the internal standard to accomplish as accurate as possible quantitation. The established method was further validated by determining the linearity (R2≥0.9990), sensitivity (LOQ, 0.29–0.99 μg/kg), recovery (88.5–119.5%) and precision (RSD≤15.8%). It was shown to be a suitable method for simultaneous determination of DON, 3‐ADON, 15‐ADON, nivalenol and fusarenon X in various TCM matrices. The utility and practical impact of the method was demonstrated using different TCM samples.  相似文献   

4.
A method for the simultaneous quantitative determination of deoxynivalenol (DON), T‐2 toxin (T‐2), HT‐2 toxin (HT‐2) and zearalenone (ZEN) in wheat and biscuit by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) coupled with immunoaffinity extraction is described. A clean‐up was carried out using a DZT MS‐PREP® immunoaffinity column (IAC), and the effect of the sample dilution rate and sample loading was investigated. Furthermore, the effects of ion suppression of a multifunctional column (MFC) and the IAC in the clean‐up were compared. The results with the DZT MS‐PREP® IAC showed that it is possible to make the sample dilution rate low, and indicated a higher solvent‐tolerance than usual with an IAC. Sample loading was optimized at 0.25 g. Ion suppression was lowered by purification of the toxins using the DZT MS‐PREP® IAC. Recoveries of each mycotoxin from wheat and biscuit samples spiked at two levels ranged from 78 to 109%. The limits of detection in wheat and biscuit was in the range of 0.03–0.33 ng·g?1. From these studies, it is suggested that use of an IAC is effective in the clean‐up of each mycotoxin, and, when combined with LC/ESI‐MS/MS, it is good for the determination of mycotoxins in foodstuffs due to its rapidity and high sensitivity. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A simple and reliable method of ultra high performance liquid chromatography coupled with photo‐diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid‐phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R2 ≥ 0.999), acceptable recoveries (80.0–104.4%), and repeatability (RSDs 1.3–10.7%). The limits of detection (21.7–57.4 μg/kg) and quantitation (72.3–191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries’ legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry.  相似文献   

6.
Two new methods of analysis, based on liquid chromatography–tandem mass spectrometry, for simultaneous determination of trichothecenes A, B, and D in maize flour and oil have been developed and validated in accordance with European Commission decision 2002/657/EC (recovery, CCα, CCβ, and precision). The trichothecenes were extracted from maize flour by matrix solid-phase dispersion, with recoveries ≥79%, and from maize oil by liquid–liquid extraction, with recoveries ≥78%. Limits of quantitation ranged between 0.03 and 50 μg kg?1, depending on the electrospray response to each analyte and on the matrix. Monitoring of flour and oil samples with this HPLC–MS–MS method revealed the presence of deoxynivalenol, T-2 toxin, and diacetoxyscirpenol at very low concentrations.  相似文献   

7.
A sensitive and robust liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of aflatoxins (B(1), B(2), G(1), G(2)), ochratoxin A, deoxynivalenol, zearalenone, T-2 and HT-2 toxins in cereal-based foods. Samples were extracted with a mixture of acetonitrile/water (84:16, v/v) and cleaned up through a polymeric solid-phase extraction column. Detection and quantification of the nine mycotoxins were performed by reversed-phase liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS), using fully (13)C-isotope-labelled mycotoxins as internal standards. The method was validated in-house for five different cereal processed products, namely barley, oat and durum wheat flours, rye- and wheat-based crisp bread. Recoveries and repeatability of the whole analytical procedure were evaluated at contamination levels encompassing the EU maximum permitted levels for each tested mycotoxin. Recoveries ranged from 89 to 108% for deoxynivalenol, from 73 to 114% for aflatoxins, from 85 to 114% for T-2 and HT-2 toxins, from 64 to 97% for zearalenone, from 74 to 102% for ochratoxin A. Relative standard deviations were less than 16% for all tested mycotoxins and matrices. Limits of detection (signal-to-noise ratio 3:1) ranged from 0.1 to 59.2 μg/kg. The trueness of the results obtained by the proposed method was demonstrated by analysis of reference materials for aflatoxins, deoxynivalenol, zearalenone. The use of inexpensive clean-up cartridges and the increasing availability of less expensive LC/MS/MS instrumentation strengthen the potential of the proposed method for its effective application for reliable routine analysis to assess compliance of tested cereal products with current regulation.  相似文献   

8.
A multi‐mycotoxin method was developed for the simultaneous determination of trichothecenes (nivalenol, deoxynivalenol, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, neosolaniol, fusarenon‐X, diacetoxyscirpenol, HT‐2 toxin, T‐2 toxin), aflatoxins (aflatoxin‐B1, aflatoxin‐B2, aflatoxin‐G1 and aflatoxin‐G2), Alternaria toxins (alternariol, alternariol methyl ether and altenuene), fumonisins (fumonisin‐B1, fumonisin‐B2 and fumonisin‐B3), ochratoxin A, zearalenone, beauvericin and sterigmatocystin in sweet pepper. Sweet pepper was extracted with ethyl acetate/formic acid (99:1, v/v). After splitting up the extract, two‐thirds of the extract was cleaned up using an aminopropyl column followed by an octadecyl column. The remaining part was cleaned up using a strong anion‐exchange column. After recombination of both cleaned parts of the sample extract, the combined solvents were evaporated and the residue was dissolved in mobile phase; 20 µL was injected into the chromatographic system, so only one run was used to separate and detect the mycotoxins in positive electrospray ionization using selected reaction monitoring. The samples were analyzed with a Micromass Quattro Micro triple quadrupole mass spectrometer (Waters, Milford, MA, USA). The mobile phase consisted of variable mixtures of water and methanol, 1% acetic acid and 5 mM ammonium acetate. The limits of detection of the multi‐mycotoxin method varied from 0.32 µg.kg?1 to 42.48 µg.kg?1. The multi‐mycotoxin liquid chromatography/tandem mass spectrometry (LC/MS/MS) method fulfilled the method performance criteria required by the Commission Regulation (EC) No 401/2006. Sweet peppers inoculated by Fusarium species were analyzed using the developed method. Beauvericin (9–484 µg.kg?1) and fumonisins (fumonisin‐B1 up to 4330 µg.kg?1, fumonisin‐B2 up to 4900 µg.kg?1, and fumonisin‐B3 up to 299 µg.kg?1) were detected. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
A surface plasmon resonance (SPR) immunoassay using a monoclonal antibody was developed to measure nivalenol (NIV) and deoxynivalenol (DON) contamination in wheat. A highly sensitive and stable DON-immobilized sensor chip was prepared, and an SPR detection procedure was developed. The competitive inhibition assay used a monoclonal antibody that cross-reacts with NIV and DON. The half maximal inhibitory concentration (IC50) values of the SPR assay were 28.8 and 14.9 ng mL−1 for NIV and DON, respectively. The combined responses of NIV and DON in wheat were obtained using a simultaneous detection assay in a one-step cleanup procedure. NIV and DON were separated using a commercial DON-specific immunoaffinity column (IAC) and their responses were obtained using an independent detection assay. Spiked tests using these toxins revealed that recoveries were in the range 91.5-107% with good relative standard deviations (RSDs) (0.40-4.1%) and that detection limits were 0.1 and 0.05 mg kg−1 for NIV and DON, respectively. The independent detection using IAC showed detection limits of 0.2 and 0.1 mg kg−1 for NIV and DON, respectively. SPR analysis results were correlated with those obtained using a conventional LC/MS/MS method for wheat co-contaminated with NIV and DON. These results suggested that the developed SPR assay is a practical method to rapidly screen the NIV and DON co-contamination of wheat and one of a very few immunoassays to detect NIV directly.  相似文献   

10.
Very often, the accuracy of quantitative analytical methods for the determination of mycotoxins by liquid chromatography (LC)-mass spectrometry (MS) and LC-MS/MS is limited by matrix effects during the ionization process in the MS source. Stable isotope labeled standards are best suited to correct for matrix effects and to improve both the trueness and the precision of analytical methods employing LC-MS and LC-MS/MS. This paper describes the successful use of fully 13C isotope labeled deoxynivalenol [(13C15)DON] as an internal standard (IS) for the accurate determination of DON in maize and wheat by LC electrospray ionization MS/MS. To show the full potential of (13C15)DON as IS, maize and wheat extracts were analyzed without further cleanup. Subsequent to calibration for the LC-MS end determination, DON was quantified in matrix reference materials (wheat and maize). Without consideration of the IS, apparent recoveries of DON were 29±6% (n=7) for wheat and 37±5% (n=7) for maize. However, the determination of DON in the reference materials yielded 95±3% (wheat) and 99±3% (maize) when (13C15)DON was used as an IS for data evaluation.  相似文献   

11.
A simple and accurate method to quantify the mycotoxin deoxynivalenol (DON) in wheat is described. The method uses immunoaffinity chromatography for DON isolation and liquid chromatography (LC) for toxin detection and quantification. Wheat samples are extracted in water, filtered twice and applied to an immunoaffinity column. Following a water wash, DON is eluted from the column with methanol and injected onto an LC system with a UV detector for quantification. Test performance was evaluated in terms of antibody specificity, limit of detection, percentage recovery, precision, column capacity, assay linearity and comparison with the GC-electron-capture detection (ECD) method of Tacke and Casper. Specificity of the immunoaffinity column cleanup procedure was confirmed with only DON (>80%) and its 15-C derivatives (40-50%) being recognized by the antibody while 3-C DON derivatives, nivalenol, T-2 and fusarenon-X did not bind. The limit of detection is at least 0.10 microg/g. Percentage recovery for the entire assay range averages 90% with an average relative standard deviation of 8.3%. Naturally contaminated samples showed comparable precision. Column capacity was determined to be 3.3 microg. The assay showed a high degree of linearity (r2=0.999) and an optimum assay range of 0.10 to 10.0 microg/g. Comparative analysis of 28 naturally or artificially contaminated wheat samples using DONtest-HPLC and the GC-ECD method of Tacke and Casper showed that DONtest-HPLC is a statistically significant predictor of the GC-ECD method (r2=0.982).  相似文献   

12.
A simple and rapid method for determining six ergot alkaloids and four of their respective epimers was developed for rye and wheat. The analytes were extracted from the sample matrix with ACN/ammonium carbonate solution. The extract was purified with a commercial push‐through SPE column (Mycosep® 150 Ergot). After concentration and filtration steps, the final separation of the analytes was achieved with ultra‐performance LC‐MS/MS. The chromatographic separation of the ergot alkaloids was achieved in 4.5 min. The method performance proved satisfactory in the preliminary validation. The calculated LOQs were low ranging from 0.01 to 1.0 μg/kg for wheat and from 0.01 to 10.0 μg/kg for rye. At the concentration levels of 10, 50 and 200 μg/kg, the recoveries were between 80 and 120% in most cases and the within‐day repeatability (expressed as RSD) ranged between 1.3 and 13.9%. Despite the cleanup of the samples, some matrix effect was observed in the MS, highlighting the necessity of using matrix‐assisted standards. This is the first article to describe the application of the push‐through columns and ultra‐performance LC in the analysis of ergot alkaloids.  相似文献   

13.
A liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) method based on time-of-flight MS (TOFMS) with a real-time reference mass correction technique was developed for the simultaneous determination of Fusarium mycotoxins (nivalenol, deoxynivalenol, fusarenon X, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol, HT-2 toxin, T-2 toxin, diacetoxyscirpenol, zearalenone) and Aspergillus mycotoxins (aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2) in corn, wheat, cornflakes and biscuits. Samples were cleaned up with a MultiSep #226 column. Detection of the mycotoxins was carried out in exact mass chromatograms with a mass window of 0.03 Th. Calibration curves were linear from 2 to 200 ng x mL(-1) for trichothecenes and zearalenone, and 0.2 to 20 ng x mL(-1) for aflatoxins, by 20 microL injection. The limits of detection ranged from 0.1 to 6.1 ng x g(-1) in foodstuffs analyzed in this study. The LC/TOFMS method was found to be suitable for the screening of multiple mycotoxins in foodstuffs rapidly and with high sensitivity, and its performance was demonstrated for the confirmation for target mycotoxins.  相似文献   

14.
The purpose of this study was to develop a simple and accurate analytical method for determination of norepinephrine, epinephrine, and dopamine in urine. The method involves liquid–liquid extraction then liquid chromatography–mass spectrometry (LC–MS). Alkyl chloroformate derivatives were prepared, as the N(O,S)-alkoxycarbonyl alkyl esters of the analytes, in the aqueous samples. The optimum derivatizing reagent for preparation of the N(O,S)-alkoxycarbonyl alkyl esters was chosen by comparing the efficiency of LC of the derivatized analytes after liquid–liquid extraction. The optimum conditions for liquid–liquid extraction from the aqueous matrix were pH 3.0, no salt, and diethyl ether as extraction solvent. Limits of detection (LOD) were 0.5 ng mL?1 for dopamine and epinephrine and 0.1 ng mL?1 for norepinephrine. Limits of quantification (LOQ) for urine samples were 1.0 ng mL?1 for all three compounds. The precision of intra- and inter-day assays was 1.65–581 and 7.17–9.73% (relative standard deviation, RSD), respectively. The range of inaccuracy for intra- and inter-day assays was ?6.47 to 11.9% and ?7.5 to 7.76% (bias) at concentrations of 5 and 50 ng mL?1, respectively.  相似文献   

15.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

16.
A LC/MS method for the simultaneous determination of both type A and type B trichothecenes by using an electrospray ionization (ESI) interface in the positive ionization mode with a single quadrupole analyzer is described. In order to enhance the ionization of both groups of trichothecenes, the sodium ion was used as cationization agent by adding sodium chloride to the eluent. All LC/MS parameters were optimized. The newly developed LC/ESI-MS method was applied to the analysis of a wheat reference material and cereal-based foods and feeds.  相似文献   

17.
For the first time we report a rapid and sensitive LC–MS–MS method for quantification of rotenone, deguelin, and rotenolone in human serum. The analytical procedure involves extraction with ethyl acetate without further clean-up. The active ingredients were separated on a C8 reversed-phase column by isocratic elution. Eleven simultaneous transitions of precursor ions were monitored. Excellent selectivity and sensitivity enables quantification and identification of low levels of rotenoids (LOD 2 ng mL?1, LOQ 5 ng mL?1) in human serum.  相似文献   

18.
This paper presents a selective and efficient sample preparation procedure for NLLGLIEAK, signature peptide for the small cell lung cancer (SCLC) biomarker ProGRP, in human serum. The procedure is based on immuno‐capture of ProGRP in 96‐wells microtiter plates coated with the mAb E146. After immuno‐capture and thorough rinse, trypsin was added for in‐well digestion. Subsequently the signature peptide was enriched by SPE and determined by LC‐MS/MS. Various steps in the procedure were optimized to achieve a low LOD such as dilution of sample, tryptic digestion, and SPE cleanup and peptide enrichment conditions. A single quadropole MS was used during optimization of the method. A triple quadropole MS was used in the method evaluation in order to improve sensitivity. The evaluation showed good repeatability (RSD, 11.9–17.5%), accuracy (3.0–6.6%), and linearity (r2 = 0.995) in the tested range (0.5–50 ng/mL). LOD and LOQ were in the pg/mL area (0.20 and 0.33 ng/mL, respectively), enabling the determination of clinically relevant concentrations. The method was applied to two patient samples and showed good agreement with an established immunological reference method. The final method was compared to a previous published LC‐MS method for the determination of ProGRP in serum based on protein precipitation and online sample cleanup. Both showed acceptable method performance, however, the immuno‐capture LC‐MS method was superior with respect to sensitivity. This illustrates the large potential of immuno‐capture sample preparation prior to LC‐MS in protein biomarker quantification.  相似文献   

19.
This study describes a comparison between LC‐UV and LC–MS method for the simultaneous analyses of a few disease‐modifying agents of multiple sclerosis. Quantitative determination of fampridine (FAM), teriflunomide (TFM) and dimethyl fumarate (DMF) was performed in human plasma with the recovery values in the range of 85–115%. A reversed‐phase high‐performance liquid chromatography (HPLC) with UV as well as MS detection is used. The method utilizes an XBridge C18 silica column and a gradient elution with mobile phase consisting of ammonium formate and acetonitrile at a flow rate of 0.5 mL min?1. The method adequately resolves FAM, TFM and DMF within a run time of 15 min. Owing to low molecular weights, the estimation of DMF and FAM is more versatile in UV than MS detection. With LC‐UV, the detection limits of FAM, TFM and DMF were 0.1, 0.05, 0.05 μg and the quantification limit for all the analytes was 1 μg. With LC–MS, the detection and quantification limits for all of the analytes were 1 and 5 ng, respectively. The two techniques were completely validated and shown to be reproducible and sensitive. They were applied to a pharmacokinetic study in rats by a single oral dose. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid and sensitive LC–MS–MS method has been developed and validated for simultaneous analysis of abacavir (ABA) and lamivudine (LAM) in human plasma. The analytes were extracted from human plasma by SPE. Nelfinavir (NEL) and emtricitabine (EMT) were used as the internal standards for ABA and LAM, respectively. An RP18 column enabled chromatographic separation of the analytes. The method involves simple isocratic chromatography and MS detection in positive-ionization mode. Validation of the method showed response was a linear function of concentration in the ranges 100.0–7000.0 ng mL?1 for ABA and 80.0–5000.0 ng mL?1 for LAM. At the LOQ levels, inter-run and intra-run precision were within 5.80 and 3.51%, respectively, for ABA and within 4.68 and 3.16%, respectively, for LAM. Overall recovery for ABA and LAM was 59.32 and 105.18%, respectively. Total elution time was 2 min only, which enabled quantification of more than 200 plasma samples per day. This validated method was used successfully for analysis of plasma samples from a bioequivalence study.  相似文献   