首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Phycotoxins.     
The 1997-1998 period brought many new developments to the phycotoxin field. There were several reviews on phycotoxins in general, on their toxicological evaluation, and on their analysis. The ecophysiology, biosynthesis, and metabolism of polyether toxins and paralytic shellfish poisoning (PSP) toxins were also reviewed. The proceedings of the Eighth International Conference on Harmful Algae (Vigo, Spain, June 25-29, 1997) have been published and provide an excellent source of information on phycotoxins and toxic plankton bloom research. In addition, the much anticipated proceedings of the IX International IUPAC Symposium on Mycotoxins and Phycotoxins (Rome, Italy, May 27-31, 1996) have been published. Further evidence was provided to support the theory that Prorocentrum lima is the source organism for diarrhetic shellfish poisoning (DSP) toxins in Nova Scotian shellfish. In another study, different Prorocentrum species and isolates were analyzed for DSP toxins. In addition to detecting some new compounds, such as a DTX1 isomer, it was found that toxins were produced by both axenic and nonaxenic batch cultures, indicating that bacteria are probably not involved in the biosynthesis. The source organism for the spirolides, a family of fast-acting toxins reported from Nova Scotia, Canada, was determined to be Alexandrium ostenfeldii, a species that is found worldwide. The biogenetic origin of yessotoxin was reported to be Protoceratium reticulatum, another widely occurring organism. A great deal of attention and research funding has been directed at the serious problems associated with Pfiesteria piscicida. Analysts are eagerly awaiting publication of toxin structures, which will then allow the development of analytical methods. An incident of the mass mortality of California sea lions was reported in the Monterey area in May 1998. Analyses of tissue and urine samples revealed the presence of domoic acid. High levels of domoic acid were also found in anchovies and sardines, a common food source of sea lions. This is reminiscent of an incident of mass bird mortality in 1992 in the same region. Toxicological studies of domoic acid continue with one investigation on the effect of pH on toxicity in the mouse assay and others examining toxic effects in rats and cynomolgus monkeys. A study on the uptake and depuration of domoic acid in the Dungeness crab was reported. On October 20, 1997, EU (European Union) directive CE97/61 established a regulatory limit of 20 ppm for domoic acid in European shellfish, the same level as in North America. A detailed study on the oral toxicity of DSP toxins in mice was reported. Recent work by several researchers has revealed the genotoxic potential of okadaic acid and other DSP toxins. Previous work had clearly demonstrated the tumor-promoting potential of DSP toxins, but this recent evidence, which shows mutations in the progeny of okadaic acid-treated cells and the formation of DNA-adducts, increases concerns over the hazards associated with DSP-contaminated shellfish. The toxicology of yessotoxin was evaluated by Ogino et al. The toxin showed weak cytotoxicity, but was not orally lethal to mice at 10 mg/kg, and did not cause intestinal fluid accumulation, inhibition of protein phosphatase 2A (PP2A), or hemolytic effects. Similarly, Tubaro et al. saw no evidence for diarrheogenicity of homoyessotoxin isolated from mussels and from the proposed planktonic producer, Lingulodinium polyedrum. All this provides further evidence that yessotoxin should not be classed as a DSP toxin. A number of new toxins have been detected and identified. Two analogues of yessotoxin, homoyessotoxin, and 45-hydroxyhomoyessotoxin were isolated from mussels of the Adriatic Sea and identified by Satake et al. A recent DSP event in Ireland associated with cultured mussels led to the identification of azaspiracid, a unique marine toxin with spiro ring assemblies. (ABSTRACT TRUNCATED)  相似文献   

2.
Unambiguous identification of mycotoxin‐producing fungal species as Fusarium is of great relevance to agriculture and the food‐producing industry as well as in medicine. Protein profiles of intact fungal spores, such as Penicillium, Aspergillus and Trichoderma, derived from matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) were shown to provide a rapid and straightforward method for species identification and characterization. In this study, we applied this approach to five different Fusarium spp. strains which are known to affect the growth of different grain plants. To obtain a suitable MALDI matrix system and sample preparation method, thin‐layer, dried‐droplet and sandwich methods and several MALDI matrices, namely CHCA, DHB, FA, SA and THAP dissolved in various solvent mixtures (organic solvents such as ACN, MeOH, EtOH and iPrOH and for the aqueous phase water and 0.1% TFA), were evaluated in terms of mass spectrometric pattern and signal intensities. The most significant peptide/protein profiles were obtained with 10 mg ferulic acid (FA) in 1 mL ACN/0.1% TFA (7:3, v/v) used as matrix system. Mixing the spores with the matrix solution directly on the MALDI target (dried‐droplet technique) resulted in an evenly distributed spores/matrix crystal layer, yielding highly reproducible peptide/protein profiles from the spore surfaces. Numerous abundant ions throughout the investigated m/z range (m/z 1500–15 000) could be detected. Differences in the obtained mass spectral patterns allowed the differentiation of spores of various Fusarium species. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
In this article we investigated the compositional and structural characteristics of the principal biomolecules such as carbohydrates, proteins, lipids, nucleic acids and chlorophyll pigments present in biofilm cultures of Ostreopsis spp. and in batch cultures of Ostreopsis ovata. Our approach based on the use of infrared (FTIR) and near infrared (FTNIR) spectroscopy showed the marked differences existing between biofilm cultures and batch cultures. FTIR spectroscopy showed the higher contents of polysaccharides and chlorophyll pigments in O. ovata from batch cultures with respect to Ostreopsis spp. Second derivative FTIR spectroscopy showed different features concerning the secondary structure of proteins because in O. ovata samples the beta sheet and beta turn structures were observed whereas in Ostreopsis spp. samples the alpha helix structure was the most evident. FTNIR spectroscopy showed other structural differences observed existing between O. ovata and Ostreopsis spp. mainly related to hydrogen bond interactions determining more packed structures in the nucleus of O. ovata. In addition, the interpretation of FTIR and FTNIR spectral information was also supported by the application of two statistical methods, the independent component analysis (ICA) and the spectral cross correlation analysis (SCCA). ICA was used as spectral deconvolution technique to separate the effects of the interference bicarbonate ion from algal FTIR spectra so to verify the high similar qualitative composition of the three biofilm samples of Ostreopsis spp. At last, SCCA applied to FTIR and FTNIR spectra was useful to evidence some structural differences involving -CH and CH(2) groups of aliphatic chains in O. ovata and Ostreopsis spp. samples. Though preliminary, these results agree with some previous studies suggesting that the presence of different ecophysiological characteristics in O. ovata and Ostreopsis spp. depending on the parameters related to the condition growth.  相似文献   

4.
Matrix‐assisted laser desorption/ionisation (MALDI) imaging mass spectrometry (IMS) allows for the simultaneous detection and imaging of several molecules in brain tissue. However, the detection of glycerolipids such as diacylglycerol (DAG) and triacylglycerol (TAG) in brain tissues is hindered in MALDI‐IMS because of the ion suppression effect from excessive ion yields of phosphatidylcholine (PC). In this study, we describe an approach that employs a homogeneously deposited metal nanoparticle layer (or film) for the detection of glycerolipids in rat brain tissue sections using IMS. Surface‐assisted laser desorption/ionisation IMS with sputter‐deposited Pt film (Pt‐SALDI‐IMS) for lipid analysis was performed as a solvent‐free and organic matrix‐free method. Pt‐SALDI produced a homogenous layer of nanoparticles over the surface of the rat brain tissue section. Highly selective detection of lipids was possible by MALDI‐IMS and Pt‐SALDI‐IMS; MALDI‐IMS detected the dominant ion peak of PC in the tissue section, and there were no ion peaks representing glycerolipids such as DAG and TAG. In contrast, Pt‐SALDI‐IMS allowed the detection of these glycerolipids, but not PC. Therefore, using a hybrid method combining MALDI and Pt‐SALDI (i.e., matrix‐enhanced [ME]‐Pt‐SALDI‐IMS), we achieved the simultaneous detection of PC, PE and DAG in rat brain tissue sections, and the sensitivity for the detection of these molecules was better than that of MALDI‐IMS or Pt‐SALDI alone. The present simple ME‐Pt‐SALDI approach for the simultaneous detection of PC and DAG using two matrices (sputter‐deposited Pt film and DHB matrix) would be useful in imaging analyses of biological tissue sections. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A method was developed for collection and analysis of bioaerosols by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry using a modified Andersen N6 bioaerosol collector. The overall goal of the study was to develop methods for obtaining mass spectra with minimal reagents and treatment steps for potential use in remote collection and analysis systems. Test bioaerosol particles were generated from a nebulized E. coli bacterial suspension and collected on MALDI targets placed in an Andersen N6 single-stage aerosol impactor. The bioaerosols were mixed with matrix either by deposition on a bare target with the matrix solution added later, or by deposition on a target pre-coated with matrix. The matrix compounds alpha-cyano-4-hydroxycinnamic acid (CHCA) and sinapic acid (SA) were tested and the SA matrix was found to give the best results in number of peaks, resolution, and signal-to-noise ratio. Deposition of bioaerosol particles onto the matrix pre-coated target did not produce signal in the m/z region above 1000, but the signal could be recovered with the addition of a 1:1 (v/v) acetonitrile/water solvent. Addition of solvent by pipette to the pre-coated targets after particle deposition recovered signal comparable to the dried-droplet sample preparations, whereas solvent sprayed into the impactor recovered fewer peaks. Deposition on pre-coated targets with post-collection solvent addition was superior to deposition on bare target followed by post-collection addition of matrix solution.  相似文献   

6.
Dinophysis spp. blooms and related shellfish toxicity events of diarrhetic shellfish poisoning (DSP) have been the most reported toxicity event through the Croatian National monitoring program. With the aim to characterize the DSP toxin profile in shellfish farmed in Croatia, for the first time a complete analysis of the toxin profile of Croatian mussels has been carried out using the LC-MS/MS technique. The obtained results showed okadaic acid (OA) as the main toxin contaminating Croatian mussels at that time. The maximum concentration of OA in shellfish tissue was recorded 12 days after the Dinophysis fortii bloom, thus suggesting that rapid growth of the toxin level in the shellfish occurred in the first week after the bloom while it was slower in the second week. Furthermore, the presence of only OA at concentrations which could endanger human health suggests D. fortii as the main organism responsible for the toxic event that occurred in Lim Bay. The presence of gymnodimine and spirolides in Croatian mussel has been detected for the first time, while the presence of yessotoxin and pectenotoxin-2 is confirmed.  相似文献   

7.
The methodology for the detection of picogram quantities of nucleotides directly from TLC plates without the use of radioactive labeling has been developed. The method couples thin-layer chromatography (TLC) separation with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) detection. The TLC/MALDI coupling protocol was studied and optimized for the separation and detection of deoxyribonucleotides. Several ammonia based solvents were examined as potential extraction solvents for the TLC/MALDI coupling protocol. It was found that in order to obtain maximum MALDI signal intensity and minimal analyte spreading, the extraction solvent should produce Rf-values for the analytes in the range of 0.3–0.4. Rf-values above this range led to extensive analyte spreading and those below this range resulted in poor extraction. Various MALDI matrices and co-matrices were investigated, the best results were obtained using 2′,4′,6′-trihydroxyacetophenone (THA) as a matrix. The extraction solvent chosen was an ammonium hydroxide/methanol (100 mM/30%, Rf = 0.28–0.38) solvent system which was found to provide the best sensitivity, minimal lateral spreading and excellent matrix transfer. Using the optimized coupling protocol, the detection limits for the deoxyribonucleotide monophosphates were established at or better than 10 picograms. Received: 27 May 1998 / Revised: 18 June 1999 / Accepted: 22 June 1999  相似文献   

8.
Sample pretreatment is key to obtaining good data in matrix‐assisted laser desorption/ionization mass spectrometry imaging (MALDI‐MSI). Although sublimation is one of the best methods for obtaining homogenously fine organic matrix crystals, its sensitivity can be low due to the lack of a solvent extraction effect. We investigated the effect of incorporating a thin film of metal formed by zirconium (Zr) sputtering into the sublimation process for MALDI matrix deposition for improving the detection sensitivity in mouse liver tissue sections treated with olanzapine. The matrix‐enhanced surface‐assisted laser desorption/ionization (ME‐SALDI) method, where a matrix was formed by sputtering Zr to form a thin nanoparticle layer before depositing MALDI organic matrix comprising α‐cyano‐4‐hydroxycinnamic acid (CHCA) by sublimation, resulted in a significant improvement in sensitivity, with the ion intensity of olanzapine being about 1800 times that observed using the MALDI method, comprising CHCA sublimation alone. When Zr sputtering was performed after CHCA deposition, however, no such enhancement in sensitivity was observed. The enhanced sensitivity due to Zr sputtering was also observed when the CHCA solution was applied by spraying, being about twice as high as that observed by CHCA spraying alone. In addition, the detection sensitivity of these various pretreatment methods was similar for endogenous glutathione. Given that sample preparation using the ME‐SALDI‐MSI method, which combines Zr sputtering with the sublimation method for depositing an organic matrix, does not involve a solvent, delocalization problems such as migration of analytes observed after matrix spraying and washing with aqueous solutions as sample pretreatment are not expected. Therefore, ME‐Zr‐SALDI‐MSI is a novel sample pretreatment method that can improve the sensitivity of analytes while maintaining high spatial resolution in MALDI‐MSI.  相似文献   

9.
Two typical clinical types of algae-related seafood poisoning have attracted medical and scientific attention: paralytic shellfish poisoning (PSP) and diarrhetic shellfish poisoning (DSP). Therefore, it became necessary to establish methods for the evaluation of possible hazards caused by contamination of seafood with these phycotoxins. Bioassays with mice or rats are the common methods for the determination of the toxin content of seafood. However, biological tests are not completely satisfactory because of a lack of sensitivity and pronounced variations. Additionally, there is growing opposition against animal testing. Therefore, many efforts have been undertaken to determine phycotoxins by chromatographic methods. PSP determination is mainly based on high-performance liquid chromatographic (HPLC) separation by ion-pair chromatography followed by postcolumn oxidation of the underivatized toxins in alkaline solution and fluorescence detection. HPLC methods for the determination of the DSP toxins okadaic acid (OA) and dinophysistoxin-1 (DTX-1) are characterized by precolumn derivatization with 9-anthryldiazomethane (ADAM) and/or 4-bromomethyl-7-methoxycoumarin (Br-Mmc), followed by chromatographic separation of the DSP esters formed and fluorescence detection. The chromatographic methods discussed in this review allow the rapid, sensitive and non-ambiguous determination of individual species of the two most important phycotoxins in seafood, PSP and DSP.  相似文献   

10.
The dinoflagellate Dinophysis acuta has been associated with various incidents of diarrhetic shellfish poisoning. A sample of Dinophysis acuta collected from New Zealand waters in 2002 was previously found to contain high levels of pectenotoxins, but only a very low level of the diarrhea-inducing okadaic acid (OA). After hydrolysis under basic conditions, however, the concentration of OA increased substantially, indicating the presence of conjugated forms of OA. Using various liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) techniques, a number of OA esters were detected in the original extract. The principal compound was identified as a C8 diol-ester of OA (OA-D8), which had been identified previously in another dinoflagellate, Prorocentrum lima. The retention time, as well as positive and negative ion MS, MS/MS and UV spectra of the D. acuta compound, matched exactly those of OA-D8 isolated from P. lima. In addition to OA-D8, several other novel OA esters were detected in the D. acuta but these have not yet been identified. This is the first report identifying the presence of OA esters in Dinophysis species.  相似文献   

11.
徐小民  张京顺  蔡增轩  孟真  黄百芬  陈苘 《色谱》2020,38(11):1281-1287
建立了在线固相萃取-液相色谱-串联质谱(online SPE-LC-MS/MS)测定蘑菇中毒患者尿液中痕量α -鹅膏毒肽的分析方法。样品经甲酸酸化的乙腈-甲醇(5:1,v/v)沉淀蛋白质,反相液液微萃取去除样品提取液中的有机溶剂,毒素经ODS微柱(5 mm×2.1 mm,5 μm)在线SPE净化,XBridgeTM BEH C18 色谱柱(150 mm×3.0 mm,2.5 μm)分离,MS/MS测定。采用基于定量环的快速阀切换技术作为在线SPE和LC-MS/MS模块的接口,使得两个分离模块互相独立,无论是流动相还是压力,都不会互相干扰,保证了系统的稳定性;在线系统的精准净化,有效消除了后续质谱检测的基质效应,确保了尿液中痕量水平α -鹅膏毒肽的定性定量检测。尿液中α -鹅膏毒肽在0.1~50 μg/L范围内线性关系良好,相关系数(r 2 )为0.9983;检出限(LOD)为0.03 μg/L;α -鹅膏毒肽的加标(0.1、2.0和20 μg/L)平均回收率为84.3%~91.7%,相对标准偏差(RSD)为3.8%~7.2%。体内鹅膏毒肽代谢迅速,生物基质中痕量水平毒素的检测是其中毒实验室鉴定的主要难题,通过实际样品检测,证明该法操作简单,准确、灵敏;溶剂沉淀蛋白质和反相液液微萃取去除有机相和脂溶性基质的简单操作,可以作为水溶性毒素在线SPE-LC-MS/MS检测时快速且有效的配套前处理方法;基于在线SPE精准净化技术,可以实现尿液中α -鹅膏毒肽的高灵敏度测定(LOD为0.03 μg/L),解决了中毒时患者体内痕量水平α -鹅膏毒肽定性确证的难题,部分患者α -鹅膏毒肽中毒实验室鉴定的时间可以扩展到90 h以上;同时,痕量水平的定量检测技术,可以为中毒后迅速代谢的α -鹅膏毒肽在体内的剂量反应关系研究提供可靠的技术支撑。  相似文献   

12.
The application of mass spectrometry to the detection of m-nitrobenzoic and 3,5-dinitrobenzoic acids and their salts on the surface of construction materials used in rocketry is described. Analytes are washed with acetonitrile from the studied surface and then analyzed by HPLC?MS with electrospray ionization or the matrix assisted laser desorption/ionization (MALDI). For electrospray ionization, the limit of detection is 6 μg/L and for MALDI ionization, 2 μg/L. The MALDI technique also ensures the direct investigation of samples without washing out; in this case, mass spectra can be visualized by constructing 2D diagrams of the distribution of nitrobenzoic acids over the surface.  相似文献   

13.
Phycotoxins produced by various species of toxigenic microalgae occurring in the plankton are a global threat to the security of seafood resources and the health of humans and coastal marine ecosystems. This has necessitated the development and application of advanced methods in liquid chromatography coupled to mass spectrometry (LC-MS) for monitoring of these compounds, particularly in plankton and shellfish. Most such chemical analyses are conducted in land-based laboratories on stored samples, and thus much information on the near real-time biogeographical distribution and dynamics of phycotoxins in the plankton is unavailable. To resolve this problem, we conducted ship-board analysis of a broad spectrum of phycotoxins collected directly from the water column on an oceanographic cruise along the North Sea coast of Scotland, Norway, and Denmark. We equipped the ship with a triple-quadrupole linear ion-trap hybrid LC-MS-MS system for detection and quantitative analysis of toxins, such as domoic acid, gymnodimine, spirolides, dinophysistoxins, okadaic acid, pectenotoxins, yessotoxins, and azaspiracids (AZAs). We focused particular attention on the detection of AZAs, a group of potent nitrogenous polyether toxins, because the culprit species associated with the occurrence of these toxins in shellfish has been controversial. Marine toxins were analyzed directly from size-fractionated plankton net tows (20 μm mesh size) and Niskin bottle samples from discrete depths, after rapid methanolic extraction but without any further clean-up. Almost all expected phycotoxins were detected in North Sea plankton samples, with domoic acid and 20-methylspirolide G being most abundant. Although AZA was the least abundant of these toxins, the high sensitivity of the LC-MS-MS enabled detailed quantification, indicating that the highest amounts of AZA-1 were present in the southern Skagerrak in the 3–20 μm size-fraction. The direct on-board toxin measurements enabled isolation of plankton from stations with high AZA-1 levels and from the most suspicious size-fraction, i.e. most likely to contain the AZA-producer. A large number (>100) of crude cultures were established by serial dilution and later screened for the presence of AZAs after several weeks growth. From one crude culture containing AZA, a small dinoflagellate was subsequently isolated and brought into pure culture. We have thus proved that even sophisticated mass spectrometers can be operated in ship laboratories without any limitation caused by vibrations of the ship’s engine or by wave movement during heavy seas at wind forces up to nine Beaufort. On-board LC–MS–MS is a valuable method for near real-time analysis of phycotoxins in plankton for studies on bloom dynamics and the fate of toxins in the food web, and for characterization and isolation of putatively toxigenic organisms.  相似文献   

14.
Solvent effect is one of the important factors in sample preparation which may affect matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra of synthetic polymers. MALDI imaging, a useful imaging tool for discovering biomarkers in tissues, is applied here for better comprehension of solvent effect in polymer analysis by MALDI-TOF mass spectrometry. Nylon-6 was chosen as a model polymer for the study of solvent effect. Its MALDI mass spectra in different solvents were performed. MALDI imaging analysis was performed for studying the incorporation of analytes into matrix crystals in different solvent combinations. Specifically, the colocalization of matrix and analyte was obtained through Pearson’s correlation (PC) coefficient analysis of their MALDI images. The results demonstrated that satisfactory spectra were obtained in higher PC value conditions. PC decreased along with an increase in the ratio of poor solvent, which suggested that we should minimize the poor solvent ratio to obtain better MALDI spectra.  相似文献   

15.
The peak intensities obtained when 2,5-dihydroxybenzoic acid (DHB) was used as a 'classic' matrix were measured using substance P (SP) and betacyclodextrin (BCD) as analytes. Enhancements in peak intensities were observed going from 1:1 MeOH/H2O to dimethylforamide (DMF) as matrix solvents. Also non-covalent interactions between SP and solvent and DHB were observed suggesting close interactions between matrix, solvent and analyte in the gas-phase. Peak enhancements were previously reported with 'superDHB' (DHB and 2-hydroxy-5-methoxybenzoic acid at 10% v/v). Co-addition of structural analogues and their respective absorption coefficients were determined. It was found that other analogues used as co-matrices could give analyte peak enhancement similar to reported for sDHB with the additional benefit that some analogues could act as matrices with DHB addition. No direct correlation was observed between absorption coefficient and the ability of the molecule to act as a 'good' UV MALDI matrix.  相似文献   

16.
The presence of marine toxins in seafood poses a health risk to human consumers which has prompted the regulation of the maximum content of marine toxins in seafood in the legislations of many countries. Most marine toxin groups are detected by animal bioassays worldwide. Although this method has well known ethical and technical drawbacks, it is the official detection method for all regulated phycotoxins except domoic acid. Much effort by the scientific and regulatory communities has been focused on the development of alternative techniques that enable the substitution or reduction of bioassays; some of these have recently been included in the official detection method list. During the last two decades several biological methods including use of biosensors have been adapted for detection of marine toxins. The main advances in marine toxin detection using this kind of technique are reviewed. Biological methods offer interesting possibilities for reduction of the number of biosassays and a very promising future of new developments.  相似文献   

17.
The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3-methylthiazolidine-4-carboxylic acid).  相似文献   

18.
Zhu HD  Lü WJ  Li HH  Ma YH  Hu SQ  Chen HL  Chen XG 《Journal of chromatography. A》2011,1218(34):5867-5871
This paper for the first time describes the development of micelle to solvent stacking (MSS) to nonaqueous capillary electrophoresis (NACE). In this proposed MSS-NACE, sodium dodecyl sulfate (SDS) micelles transport, release, and focus analytes from the sample solution to the running buffer using methanol as their solvent. After the focusing step, the focused analytes were separated via NACE. The focusing mechanism and influencing factors were discussed using berberine (BBR) and jatrorrhizine (JTZ) as model compounds. And the optimum condition was obtained as following: 50 mM ammonium acetate, 6% (v/v) acetic acid and 10 mM SDS in redistilled water as sample matrix, 50 mM ammonium acetate and 6% (v/v) acetic acid in pure methanol as the running buffer, -20 kV focusing voltage with 30 min focusing time. Under these conditions, this method afforded limits of detection (S/N=3) of 0.002 μg/mL and 0.003 μg/mL for BBR and JTZ, respectively. In contrast to conventional NACE, the concentration sensitivity was improved 128-153-fold.  相似文献   

19.
Artifact-free, high-resolution matrix-assisted laser desorption ionization (MALDI) time-of-flight mass spectra have been obtained for the labile, single-isomer, tert.-butyldimethylsilyl ether derivatives of alpha-, beta- and gamma-cyclodextrins by optimizing the MALDI sample preparation method. 2,5-Dihydroxybenzoic acid, a 3:1 mixture of 2,5-dihydroxybenzoic acid and 1-hydroxyisoquinoline, and 2,4,6-trihydroxyacetophenone were investigated as MALDI matrices with methanol and acetonitrile as matrix solvents. Partial-to-complete loss of the tert.-butyldimethylsilyl groups was observed when the commonly used 2,5-dihydroxybenzoic acid was the MALDI matrix and/or methanol was the solvent, both with and without trifluoroacetic acid as additive. Loss of the labile tert.-butyldimethylsilyl groups was avoided with 2,4,6-trihydroxyacetophenone as MALDI matrix and acetonitrile as matrix solvent. Good ion intensities were achieved for the (M+Na)+ and (M+K)+ quasimolecular ions in the positive-ion mode. Minor byproducts were observed in some of the samples and the information was used to aid the optimization of the synthetic work.  相似文献   

20.
An extended study of different sampling introduction approaches using inductively coupled plasma mass spectrometry (ICP-MS) is presented for the determination of boron in steel samples. The following systems for sample introduction were applied: direct sample solution nebulization by continuous nebulization (CN) using a cross-flow nebulizer and with flow injection (FI), applied to 0.1% (m/v) and 0.5% (m/v) sample solutions, respectively; FI after iron matrix extraction, using acetylacetone–chloroform, and isotopic dilution (ID) analysis as the calibration method; FI with on-line electrolytic matrix separation; and spark ablation (SA) and laser ablation (LA) as solid sampling techniques. External calibration with matrix-matching samples was used with CN, SA, and LA, and only acid solutions (without matrix matching) with FI methods. When FI was directly applied to a sample solution, the detection limit was of 0.15 μg g−1, improving by a factor of 4 that was obtained from the CN measurements. Isotopic dilution analysis, after matrix removal by solvent extraction, made it possible to analyse boron with a detection limit of 0.02 μg g−1 and, with the on-line electrolytic process, the detection limit was of 0.05 μg g−1. The precision for concentrations above 10 times the detection limit was better than 2% for CN, as well as for FI methods. Spark and laser ablation sampling systems, avoiding digestion and sample preparation procedures, provided detection limits at the μg g−1 levels, with RSD values better than 6% in both cases. Certified Reference Materials with B contents in the range 0.5–118 μg g−1 were used for validation, finding a good agreement between certified and calculated values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号