首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple separation/pre-concentration method was developed for extraction of Pd(II) in various environmental samples, based on its adsorption of 4–phenyl–5–{[(4–phenyl–5–pyridin–4–yl–4H–1,2,4–triazole–3–yl)thio]methyl}–4H–1,2,4–triazole–3–thyol (PPTTMET) complex on Amberlite XAD–2010 resin in a mini column. The ligand has high affinity for Pd(II) among many other metals that are taken into consideration. The flame atomic absorption spectrometry is employed to determine the concentration of Pd(II). The optimum working conditions which were determined are as follows: 0.05?mol?L?1 HNO3 as working medium, 1.0?mol?L?1 HCI in acetone as elution solvent, 0.75?mg of PPTTMET amount and 750?mL of sample volume. The system was independent from the flow rates between 3.1 and 23.1?mL?min?1. The Pd(II) adsorption capacity of Amberlite XAD–2010 resin was found to be 12.8?mg?g?1 and the enrichment factor was calculated as 375. The method was successfully applied for the determination of Pd(II) in motorway dust samples, anodic sludge, gold ore, industrial electronic waste materials and various water samples.  相似文献   

2.
Polystyrene (PS) was extracted from styrofoam waste and functionalised with schiff base, N,N-bis(salicylidene)cyclohexanediamine (SCHD) through an azo spacer. The resin was characterised and used for preconcentration of Pb(II), Ni(II) and Cd(II) ions prior to their trace determinations by microsample injection system–coupled flame atomic absorption spectrometry (MIS-FAAS). The recoveries of studied metal ions were achieved ≥96.0% with relative standard deviation (RSD) ≤4.5 at optimum parameters: pH 8; resin amount 300 mg; flow rates 3.0 mL min?1 of sample solution; and 2.0 mL min?1 of eluent (2.0 mol L?1 HNO3). The limits of detection (LODs) and limits of quantification (LOQs) were found to be 0.32, 0.23 and 0.21 and 1.10, 0.78 and 0.69 μg L?1, respectively, with preconcentration factors (PFs) of 500, 800 and 1000, respectively. The linear ranges of the method were 1–40, 1–25 and 1–20 μg L?1 for Pb(II), Ni(II) and Cd(II) ions, respectively. The accuracy and validation of the method were evaluated by analysis of certified reference materials (CRMs). The method was successfully applied for preconcentration of studied metal ions in wastewater and wastewater-irrigated vegetable samples.  相似文献   

3.
A new method, termed dispersive liquid–liquid microextraction (DLLME), was developed for the extraction and pre-concentration of estrone (E1) and 17β-estradiol (E2) in water samples. The samples were extracted by 0.50 mL methanol (disperser solvent) containing 25.0 μL tetrachloroethane (extraction solvent). Important factors such as the volume and type of extraction and disperser solvent, extraction time and salt effect were studied. Under optimum conditions, the enrichment factors and the limits of detection were 347 and 0.2 ng mL?1 for E1, and 203 and 0.1 ng mL?1 for E2, respectively. The linear range was 0.5–5,000 ng mL?1. Compared to other methods, DLLME–LC–VWD has advantages for E1 and E2 analysis in water: high enrichment factor, low cost, simplicity, quick and easy operation.  相似文献   

4.
Multi-walled carbon nanotubes (MWCNTs) were chemically functionalized by glutaric dihydrazide (GDH) and characterized with FT-IR technique. This new sorbent was used for enrichment and preconcentration of Co(II), Cd(II), Pb(II), and Pd(II) ions. The adsorption was achieved quantitatively on MWCNTs at pH 4.0, and then the retained metal ions on the adsorbent were eluted with 1.5 mol L?1 HNO3. The effects of analytical parameters including pH of the solution, eluent type, sample volume, and matrix ions were investigated for optimization of the presented procedure. The adsorption capacity of the adsorbent at optimum conditions was found to be 33.6, 29.2, 22.1, and 36.0 mg g?1 for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The LOD values of the method were 0.16, 0.19, 0.17, and 0.12 ng mL?1 (3Sb, n = 10) for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The RSDs values of the method were 0.75, 0.85, 1.16, and 1.30 ng mL?1 for Co(II), Cd(II), Pb(II), and Pd(II), respectively. The method was applied for the determination of analytes in soil, well water, and wastewater samples with satisfactory results.  相似文献   

5.
在pH为5.0-5.4的乙酸-乙酸钠缓冲溶液中,克林霉素(Clin)与钯(Ⅱ)形成螯合阳离子,它能进一步与二碘荧光素(DIF),赤藓红(Ery),曙红Y(EY)等卤代荧光素类染料反应形成1:1:1的三元离子缔合物,此时将引起吸收光谱变化和荧光猝灭,同时还导致共振瑞利散射(RRS)的急剧增强并产生新的RRS光谱,钯(Ⅱ)-克林霉素与DIF,Ery和EY形成产物的最大散射波长分别位于285,287,32 1nm处,另外还有些较弱的散射峰存在。散射增强(ΔI)与克林霉素浓度在一定范围内成正比,可用于克林霉素的定量测定。对于DIF,Ery和EY体系的线性范围和检出限分别为0.025-2.1μg•mL-1和7.8 ng•mL-1,0.053-2.4μg•mL-1和16.0 ng•mL-1;以及0.038-2.4μg•mL-1和11.0 ng•mL-1。本文研究了适宜的反应条件,考察了共存物质的影响,表明方法有较好的选择性,基于三元离子缔合物的RRS光谱,发展了一种高灵敏、简便快速测定克林霉素的新方法。文中还对离子缔合物的组成,结构和反应机理,以及离子缔合物对吸收,荧光和RRS光谱的影响进行了讨论。  相似文献   

6.
Immobilization of β-cyclodextrin on Dowex resin as an insoluble polymeric matrix by covalent bond presents a new solid-phase medium for preconcentration of Pb (II) at trace level in environmental samples prior to its flame atomic absorption spectrometric determination. The method is based on the sorption of lead after passing on modified Dowex sorbent in a column. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The sorption capacity of the matrix has been found to be 0.4996?mg?g?1 of adsorbent with the preconcentration factor of 250 for Pb (II). Nitric acid (3 M) as an eluent was sufficient to obtain quantitative recovery (>95%) for Pb (II). The optimum flow rate was 10?ml?min ?1. The calibration curve was linear in the range of (3–250?ng?mL?1) with a correlation coefficient of 0.9995. The limit of detection (LOD) based on three times the standard deviation of the blank was 1.37?ng?mL?1. The relative standard deviation (RSD) for determination of 10?ng?mL?1 and 100?ngmL?1 of Pb (II) was 3.00 % and 0.58 % (n?=?10), respectively. The method was successfully applied to determination of lead in some environmental samples such as tap water, river water, soil and rice.  相似文献   

7.
《Analytical letters》2012,45(5):745-756
A new method was developed using weak anion exchange resin modified with sodium diethyldithiocarbamate (DDTC) for the derivatization and preconcentration of copper(II) in water prior to spectrophotometric determination. Several conditions affecting the extraction efficiency were investigated. Under the optimum conditions, an enrichment factor of 50 was achieved. The reaction mechanism of copper(II) and DDTC on the resin and binding experiment was studied. The detection limit is 0.6 μ g L?1. The relative standard deviations of intra- and inter-day ranging from 2.1 to 3.6% and from 1.3 to 4.0% were obtained, respectively, and the recoveries were in the range of 95.3–99.6%.  相似文献   

8.
《Analytical letters》2012,45(12):1978-1990
A novel absorbent was prepared by sodium dodecyl sulfonate (SDS)-modified activated carbon (SDS-AC) and was employed as the microcolumn packing material for separation/preconcentration of trace Cd(II). The method based on Cd(II) was quantitatively retained by SDS-AC sorbent, which entailed cation exchange nature and negative charged surface, facilitating favorable retention of positively charged ions. The retained Cd(II) was effectively recovered with elution by 1 mol · L?1 HNO3, and the eluent was quantified by electrothermal atomic absorption spectrometry (ET-AAS). Under the optimized conditions, the limit of detection (LOD) for Cd(II) was 3 ng · L?1 with the consumption of 20.0 mL sample solution. The relative standard deviation (RSD) for ten replicate measurements of 50 ng · L?1 Cd(II) was 2.9%. The developed technique was demonstrated for the determination of trace Cd(II) in water samples and the recoveries for spiked samples were found to be in the range of 94.9–107.2%. For validation, two certified reference materials of water samples (GBW08607 and GBW08608) were analyzed, and the results obtained were in good agreement with the certified values.  相似文献   

9.
Amberlite XAD-2 has been functionalized by coupling it to quinalizarin [1,2,5,8-tetrahydroxyanthraquinone] by means of an -N = N- spacer. Elemental analysis, thermogravimetric analysis, and infrared spectra were used to characterize the resulting new polymer matrix. The matrix has been used to preconcentrate Cu(II), Cd(II), Co(II), Pb(II), Zn(II), and Mn(II) before their determination by flame atomic absorption spectrometry (FAAS). UO2(II) has been preconcentrated for fluorimetric determination. The optimum pH values for maximum adsorption of the metals are between 5.0 and 7.0. All these metal ions are desorbed (recovery 91–99%) with 4 mol L–1 HNO3. The adsorptive capacity of the resin was found to be in the range 0.94–5.28 mg metal g–1 resin and loading half-life (t1/2) between 5.3 and 15.0 min. The effects of NaF, NaCl, NaNO3, Na2SO4, Na3PO4, Ca(II), and Mg(II) on the adsorption of these metal ions (0.2 μg mL–1) are reported. The lower limits of detection for these metal ions are between 1 and 15.0 μg L–1. After enrichment on this matrix flame AAS has been used to determine these metal ions (except the uranyl ion) in river water samples (RSD ≤ 6.5%); fluorimetry was used to determine uranyl ion in well water samples (RSD ≤ 6.3%). Cobalt from pharmaceutical vitamin tablets was preconcentrated by use of this chelating resin and estimated by FAAS (RSD ~ 4%).  相似文献   

10.
Mononuclear cobalt(II), nickel(II), and copper(II) complexes of cetirizine·2HCl (CTZ = 2-[2-[4-[(4-chlorophenyl)phenyl methyl]piperazine-1-yl]-ethoxy]acetic acid) in the presence of alanine (Ala) as a representative example of amino acids were synthesized and elucidated by different physical techniques. All complexes have been characterized with the help of elemental analyses, molecular weights, molar conductance values, magnetic moments, and spectroscopic data. The measured molar conductance values in DMSO indicate that the complexes are nonelectrolytes. Quantum chemical calculations were performed with semi-empirical method to find the optimum geometry of complexes. The metal–oxygen bond length in the synthesized complexes obeys the order M–OH2 > M–OCTZ > M–OAla. Formation equilibria of the ternary complexes have been investigated. Ternary complexes are formed by a simultaneous mechanism. Stoichiometry and stability constants for the complexes formed are reported. The concentration distributions of various species formed in solution were also evaluated as a function of pH. CTZ and its metal chelates have been screened for their antimicrobial activities against some selected types of gram-positive (G+) and gram-negative (G?) bacteria. They were more active against (G+) than (G?) bacteria.  相似文献   

11.
《Analytical letters》2012,45(16):2570-2582
A simple and accurate solid phase extraction method was developed for the determination of Cu(II), Ni(II), and Zn(II) at trace levels by microsample injection system coupled flame atomic absorption spectrometry. The proposed method is based on the retention of complexes of metal ions with 4-(2-pyridylazo) resorcinol on Amberlite XAD-7 resin and elution with acetone. The possible parameters influencing the preconcentration were optimized. The interferences of coexisting ions were studied. Under the optimal conditions, the detection limits of Cu(II), Ni(II), and Zn(II) were 0.058, 0.013, and 0.027 µg L?1, respectively. The applicability and the accuracy of the proposed method were validated by analysis of BCR 715 wastewater as a certified reference material and spiked real samples. Recoveries in the range of 94–105% were obtained with relative errors less than 7.5% and relative standard deviations less than 3.2%.  相似文献   

12.
Baytak S  Türker AR 《Talanta》2005,65(4):938-945
A microorganism Agrobacterium tumefacients as an immobilized cell on a solid support was presented as a new biosorbent for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to flame atomic absorption spectrometric analysis. Amberlite XAD-4 was used as a support material for column preconcentration. Various parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of sample solution, volume of sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of above mentioned metal ions were about 6, 8, 8 and 6, respectively. The loading capacity of adsorbent for Co(II) and Mn(II) were found to be 29 and 22 μmol g−1, respectively. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III), under the optimum conditions were found to be 99 ± 3, 99 ± 2, 98 ± 3 and 98 ± 3%, respectively, at the 95% confidence level. The limit of detection was 3.6, 3.0, 2.8 and 3.6 ng ml−1 for Fe(III), Co(II), Mn(II) and Cr (III), respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied for metal ion determination from water samples, alloy samples, infant foods and certified samples such as whey powder (IAEA-155) and aluminum alloy (NBS SRM 85b). The analytes were determined with a relative error lower than 10% in all samples.  相似文献   

13.
14.
The ligand, 8-hydroxyquinoline-5-sulfonic acid, forms anionic complexes with cobalt(II), zinc(II), cadmium(II), and lead(II), each resulting complex showing a high affinity for anion-exchange resins. The effect of pH, ligand/metal ratio, volume, and concentration on percent retention of the anionic complexes by an anion-exchange resin are reported. At optimum conditions, all four metals are quantitatively retained by the column. Zinc, cadmium and lead(II) ions are completely eluted with 11 ml or less of 2 M HN03; cobalt(II) is totally removed by 12 M HCl and 2 M HNO3. Concentration enhancements of 100-fold are easily achieved. All four anionic complexes can be left on the column for 7 days and still be quantitatively (99%) recovered. A ligand-loaded resin column can also remove all four metals quantitatively. Distribution coefficients for the metal complexes and their ligand/metal ratios were determined by using batch methods that may also serve as the isolation procedure.  相似文献   

15.
A novel dual-syringe flow injection (DSFI) on-line column preconcentration system coupled to flame atomic absorption spectrometry (FAAS) has been developed for automatic trace metal determination in natural waters and biological samples. The proposed method was based on the on-line retention of Cd(II), Pb(II), Cu(II), Co(II) and Ni(II) ions onto the surface of a strong cation exchanger resin named HyperSepSCX, in a readily exchangeable micro-cartridge format and subsequent elution with HCl (2?mol?L?1) prior to flame atomization. The sorbent and the micro-cartridge exhibited high long term chemical and mechanical stability with fast kinetics for all analytes. All main chemical and hydrodynamic factors affecting the performance of the proposed method were studied thoroughly. For 15.0?mL sample volume, the enhancement factors were calculated as 92, 97, 93, 99 and 77 for Cd(II), Pb(II), Cu(II), Co(II) and Ni(II) respectively and the detection limits (3?s) were in the range between 0.14 and 2.1?µg?L?1. The precision (RSD) obtained was lower than 3.3% for all five metal ions with a sample throughput of 12?h?1. The developed method was evaluated by analyzing certified reference materials and spiked environmental natural water samples.  相似文献   

16.
Lead(II) 4,4,4-trifluoro-1-phenyl-1,3-butandionate (TFPB?) complexes with 1,10-phenanthroline (phen) and 2,2′-bipyridine (2,2′-bipy), [Pb(L)(TFPB)2], have been synthesized and characterized by elemental analysis, IR-, 1H NMR spectroscopy and studied by X-ray crystallography. The self-assembly of [Pb(L)(TFPB)2] complexes, (L?=?phen or 2,2′-bipy) is caused by CH?···?F–C, C–H?···?O–C and π–π stacking interactions. The thermal stabilities of compounds were studied by thermal gravimetric (TG) and differential thermal analyses (DTA).  相似文献   

17.
A simple, rapid and efficient method termed dispersive liquid–liquid microextraction combined with liquid chromatography-fluorescence detection, has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in water and fruit juice samples. Parameters such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were optimized. Under optimum conditions, the enrichment factors ranged from 296 to 462. The linear range was 0.01–100 μg L?1 and limits of detection were 0.001–0.01 μg L?1. The relative standard deviations (RSDs, for 5 μg L?1 of PAHs) varied from 1.0 to 11.5% (n = 3). The relative recoveries of PAHs from tap, river, well and sea water samples at spiking level of 5 μg L?1 were 82.6–117.1, 74.9–113.9, 77.0–122.4 and 86.1–119.3%, respectively. The relative recoveries of PAHs from grape and apple juice samples at spiking levels of 2.5 and 5 μg L?1 were 80.8–114.7 and 88.9–123.0%, respectively. It is concluded that the proposed method can be successfully applied for determination of PAHs in water and fruit juice samples.  相似文献   

18.
A novel UV-VIS spectrophotometric method was developed in this study by using solid phase extraction procedure for the simultaneous preconcentration, separation and determination of trace levels of Pb (II), Cd (II) and Zn (II) ions in various water samples by using Amberlite N,N-bis(salicylidene)cyclohexanediamine (SCHD) resin. This study presents the results of experimental procedures carried out like the adsorption of analytes to the resin, influences of some analytical parameters that effect the recovery such as pH, sample volume, sample flow rate, eluent type and concentration, eluent volume, eluent flow rate and the effects of alkaline metals, earth alkaline metals and some other transition metals. The analytes in the samples with the adjusted pH range of 4–7 were adsorbed on XAD-4-SCHD resin and eluted by using 1.0 mol L?1 nitric acid. The amounts of ions were determined by using UV-VIS spectrometer. The limits of detection were 0.03, 0.07 and 0.05 µg mL?1 for Pb (II), Cd (II) and Zn (II), respectively. The accuracy of the method was assured by the analysis of the certified standard water sample NW-TMDA-70.2 and the observed recoveries were above 93%. Different environmental water samples that contain trace amounts of Pb (II), Cd (II) and Zn (II) were analysed by using the method developed in this study. Same samples were also analysed by ICP-MS for comparison and almost the similar results were observed. The method developed in this study was successfully applied to the various environmental water samples to determine the trace levels of Pb (II), Cd (II) and Zn (II) ions.  相似文献   

19.
The possibility of using Thio-Michler's Ketone (TMK), 4,4′-bis(dimethylamino) thiobenzophenone, for palladium(II) concentrated by micellar extraction at the cloud-point temperature, and later spectrophotometric determination, was investigated. Under the optimum conditions, preconcentration of 50?mL of water samples in the presence of 0.1% (w/v) octylphenoxy polyethoxy ethanol (Triton X-114), 2?×?10?6?mol?L?1?TMK and 1?×?10–3?mol?L?1 buffer solution (pH?=?3.0) gave the limit of detection of 0.47?ng?mL?1, and the calibration graph was linear in the range of 2–50?ng?mL–1. The recovery under optimum working conditions was higher than 97%. The proposed method has been applied to the spectrophotometric determination of palladium(II) in natural water samples after cloud-point extraction with satisfactory results.  相似文献   

20.
A method was developed for the on-line determination of palladium in complex matrices with flame atomic absorption spectrometry (FAAS) using Amberlite XAD-16 resin functionalized with 2-[2-(5-thiol-1,3,4-thiadiazolyl)]-azonaphthol (TTAN) reagent. Optimum experimental conditions such as pH of sample, type of eluent, amount of resin, volumes of sample and eluent solution, flow rates of sample and eluent, and effect of interfering ions were established. A 0.1?mol?L?1 thiourea solution in 0.5?mol?L?1 HCl was used as the eluent and subsequently transportation the analyte ions into the nebulizer–burner system for atomization. The synthesized chelating resin material showed excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates without significant losses of retention efficiency. The detection limit of the method was 1.5?µg?L?1 while the relative standard deviation (RSD%) was 2.4% at 0.1?mg?L?1 Pd(II) level. The developed method was successfully applied to the determination of palladium in the catalytic converter and water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号