首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A flow-through CL method for the determination of lead combined with controlled-reagent-release technology has been developed. Chemiluminescence (CL) reagents luminol and potassium permanganate were immobilized on anion exchange resin by electrostatic interaction. Lead ion was determined by its enhancing effect on the CL reaction between luminol and potassium permanganate. Both luminol and potassium permanganate were eluted from the anion exchange resin column by sodium phosphate solution. The linear range of the system was 10 μg mL?1, and the detection limit was 5?×?10–9 g mL?1 lead (3σ). A complete analysis could be performed in 1 min with a relative SD 3.2% (1.0?×?10–7 g mL?1, n?=?9). The column shows remarkable stability and can be reused over 350 times and 21 days. The method has been applied to determine lead in human blood samples.  相似文献   

2.
A novel flow injection chemiluminescence (FI‐CL) method for the determination of genistein was described. The method was based on the reaction between genistein and potassium ferricyanide in alkaline solution to give weak CL signal, which was dramatically enhanced by rhodamine 6G (Rh G). The CL emission allowed quantitation of genistein concentration in the range 1.0 × 10?7–4.0 × 10?5 mol/L with a detection limit (3σ) of 4.2 × 10?8 mol/L. The relative standard deviation for 11 parallel measurements of 5.0 × 10?7 mol/L, 4.0 × 10?6 mol/L and 1.0 × 10?5 mol/L genistein were 2.59%, 2.40% and 1.48%, respectively. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. The method was applied to the determination of genistein in biological fluids.  相似文献   

3.
张四纯  周国俊  鞠熀先 《中国化学》2002,20(10):1049-1054
IntroductionGallicacidexistsintheleavesandfruitsofmanytypesofplantsandiswidelyusedinmedicineforanti oxi dationandantibacterialactivity ,antiflammatoryactionandanti canceractivity .1 5Inspiteofthehealthimportanceofgallicacid ,itsmetabolismandkineticsinthehu…  相似文献   

4.
儿茶酚胺是一类非常重要的神经递质,在人体的心血管系统、神经系统、内分泌腺、肾脏、平滑肌等组织系统的生理活动中起着广泛的调节作用。肾上腺素为儿茶酚胺的一种,建立灵敏、高效的肾上腺素检测技术具有重要的临床意义。本文将银(Ⅲ)配合物与鲁米诺组成新的流动注射化学发光体系,利用碱性介质中肾上腺素对三价银配合物-鲁米诺化学发光体系有明显的增强效应来测定肾上腺素的含量,并据此建立了高效测定肾上腺素的流动注射化学发光新方法。在优化的条件下,该方法测定肾上腺素的线型范围为1.0×10-9~1.0×10-7 mol L-1,检出限为8.0×10-10 mol L-1,对1.5×10-8 mol L-1肾上腺素11次平行测定,其相对标偏差为2.9%。利用建立的分析方法测定了药物肾上腺素,并对三价银-鲁米诺化学发光新体系测定肾上腺素的反应机理进行了讨论。  相似文献   

5.
A flow-injection procedure is described for the determination of carbaryl based on its inhibition effect on luminol-cobalt(II) chemiluminescence reaction in alkaline medium in the presence of hydrogen peroxide. The calibration data over the range 5.0?×?10?7 to 20?×?10?6?M give a correlation coefficient (r 2) of 0.9972 with relative standard deviations (RSD; n?=?4) in the range of 1.0–2.1% with a limit of detection (3?×?blank noise) of 2.37?×?10?7?M for carbaryl. The sample throughput was 120?h?1. The effects of some carbamates, anions, and cations were studied on luminol CL system for carbaryl determination. The proposed method has been applied to determine carbaryl in natural waters.  相似文献   

6.
β‐Agonists are a group of illegal feed additives. In this paper, it was found that the light emission produced by the oxidation of luminol by potassium ferricyanide was enhanced by the β‐agonists (ractopamine, salbutamol, and terbutaline). Based on chemiluminescence phenomenon, a novel, rapid, and sensitive microflow injection analysis system on a microfluidic glass chip was established for determination of the β‐agonists. The chip was fabricated from two glass plates (64 mm × 32 mm) with microchannels of 200 μm width and 100 μm depth. The detection limits were achieved at 2.0 × 10?8 mol/L of ractopamine, 1.0 × 10?8 mol/L of terbutaline and 5.0 × 10?7 mol/L of salbutamol. In this report, our method was applied for determination of the β‐agonists in swine hair from three different sources with satisfactory results.  相似文献   

7.
A new post-chemiluminescence (PCL) phenomenon was observed when phenothiazine medications were injected into the reaction mixture after the chemiluminescence (CL) reaction of luminol and potassium ferricyanide had finished. A possible reaction mechanism was proposed based on studies of the kinetic characteristics of the CL, CL spectra, fluorescence spectra, and on other experiments. The feasibility of determining various phenothiazine medications by utilizing these PCL reactions was examined. A molecular imprinting–post-chemiluminescence (MI-PCL) method was established for the determination of chlorpromazine hydrochloride using a chlorpromazine hydrochloride-imprinted polymer (MIP) as the recognition material. The method displayed high selectivity and high sensitivity. The linear range of the method was 1.0×10−8∼1.0×10−6, with a linear correlation coefficient of 0.9985. The detection limit was 3×10−9 g/ml chlorpromazine hydrochloride, and the relative standard deviation for a 1.0×10−7 g/ml chlorpromazine hydrochloride solution was 4.0% (n=11). The method has been applied to the determination of chlorpromazine hydrochloride in urine and animal drinking water with satisfactory results.   相似文献   

8.
A novel chemiluminescence (CL) method for the determination of hydrogen peroxide is described. Method is based on the transition metals in highest oxidation state complex, which include diperiodatoargentate (DPA) and diperiodatonickelate (DPN) and show excellent sensitisation on the luminol-H2O2 CL reaction with low luminol concentration in alkaline medium. In particular, the sensitiser which was previously reported (such as Co2+, Cu2+, Ni2+, Mn2+, Fe3+, Cr3+, KIO4, K3Fe(CN)6 etc.) to be unobserved CL due to poor sensitisation with such low concentration of luminol which makes the method hold high selectivity. Based on this observation, the detection limits were 6.5?×?10?9?mol?L?1 and 1.1?×?10?8?mol?L?1 hydrogen peroxide for the DPN- and DPA-luminol CL systems, respectively. The relative CL intensity was linear with the hydrogen peroxide concentration in the range of 2.0?×?10?8–6.0?×?10?6?mol?L?1 and 4.0?×?10?8–4.0?×?10?6?mol?L?1 for the DPN- and DPA-luminol CL systems, respectively. The proposed method had good reproducibility with a relative standard deviation of 3.4% (8.0?×?10?7?mol?L?1, n?=?7) and 1.0% (2.0?×?10?6?mol?L?1, n?=?7) for the DPN- and DPA-luminol CL systems, respectively. A satisfactory result has been gained for the determination of H2O2 in rainwater and artificial lake water by use of the proposed method.  相似文献   

9.
Iron(II) (1.0 × 10?9–1.0 × 10?6 M) is determined by the production of chemiluminescence in a luminol system in the absence of added oxidant. Iron(III) (2.0 × 10.8?8–2.0 × 10?6 M) is determined after reduction to iron(II) in a silver reductor mini-column in the flow system. Cobalt, chromium, copper and manganese interfere.  相似文献   

10.
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol‐AgNO3‐Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. The UV‐vis absorption spectrum and CL emission spectrum were applied to confirm the mechanism. The method is simple, rapid and sensitive with a detection limit of 5×10?10 g·mL?1 and a linear range of 8.0×10?10–1.0×10?7 g·mL?1. The relative standard deviation (RSD) is 1.3% for eleven measurements of 5×10?8 g·mL?1 gallic acid. The method has been successfully applied to the determination of gallic acid in Chinese proprietary medicine–Jianmin Yanhou tablets and synthesized samples.  相似文献   

11.
聂菲  吕九如 《化学学报》2007,65(20):2299-2302
发现钙黄绿素可以吸收铁氰化钾氧化酮替芬反应的化学能而产生化学发光, 以钙黄绿素为化学发光试剂, 构建了铁氰化钾-酮替芬-钙黄绿素化学发光体系, 利用此体系建立了测定酮替芬的化学发光分析新方法, 方法的线性范围为2.0×10-8~6.0×10-6 g•mL-1, 检出限为8×10-9 g•mL-1, 对浓度为5.0×10-7 g•mL-1酮替芬溶液进行11次平行测定的相对标准偏差(RSD)为2.1%. 此法已用于药品中酮替芬含量的测定, 结果与药典测定结果一致. 对化学发光反应的机理也进行了初步的探讨.  相似文献   

12.
This work presents a new chemiluminescent (CL) probe array assay. The new type CL probe array is based on enzyme mimics of Co3O4–SiO2 mesoporous nanocomposite material, which not only have an excellent catalytic effect on the luminol–H2O2 CL reaction in an alkaline medium but also can be used for the immobilization of enzymes. The linear range of the lactose concentration is 3.0?×?10?7 to 1.0?×?10?5 g mL?1 and the detection limit is 6.9?×?10?8 g mL?1. β-Galactosidase and glucose oxidase were selected as a model for enzyme assays to demonstrate the applicability of Co3O4–SiO2 mesoporous nanocomposite material in multienzyme immobilization. The novel bifunctional CL probe array has been successfully applied to the determination of lactose in milk.  相似文献   

13.
A new voltammetric procedure for the simultaneous determination of dopamine (DA) and paracetamol (PA) using boron doped diamond electrode modified with Nafion and lead films (PbF/Nafion/BDDE) was investigated. The use of this electrode resolved the overlapped voltammetric waves of DA and PA into well‐defined peaks with peak to peak separation of about 320 mV. Under the optimized experimental conditions in differential pulse voltammetric technique, DA and PA gave a linear response over the ranges 2.0×10?7–1.0×10?4 mol L?1*(R2=0.9996) and 5.0×10?7–1.0×10?3 mol L?1 (R2=0.9979), respectively. The detection limits were found to be 5.4×10?8 mol L?1 for DA and 1.4×10?7 mol L?1 for PA. They are lower, comparable or in some cases a little bit higher than those obtained using other electrochemical sensors. However, the proposed procedure of the sensor preparation is much simpler than procedures described in the literature with a lower detection limit. The proposed procedure was successfully applied to the determination of PA in some commercial pharmaceuticals as well as to the simultaneous determination of DA and PA in human urine, whole blood and serum samples directly without any separation steps.  相似文献   

14.
A novel core-shell luminol-based SiO2 nanoparticle While these nanoparticles were used as electrogenerated was synthesized by two step micro-emulsion method. chemiluminescence (ECL) reagent, the electrochemical (EC) reaction as well as the subsequent chemiluminescence (CL) reaction not only could be separated spatially, but also presented high efficiency for analytical purpose. In this case, the core-shell luminol-based SiO2 nanoparticles offered more potential to avoid the contradiction between the EC and the CL reaction conditions. A new ECL method based on the nanoparticle was developed, and isoniazid was selected as a model analyte to illustrate the characteristics of this new ECL method. Under the selected conditions, the proposed ECL response to isoniazid concentration was linear in the range of 1.0 ×10^-10 to 1.0 × 10^-6 g/mL with 2 × 10^-11g/mL detection limit.  相似文献   

15.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

16.
The electrochemical polymerization of glycine on carbon ionic liquid electrode (CILE) was described. The presence of ionic liquid on the surface of CILE facilitated the electropolymerization of glycine. The polyglycine modified CILE provided a valid and simple approach to selectively detect dopamine in the presence of AA in physiological environment. The proposed sensor not only decreased the voltammetric responses of AA but also dramatically enhanced the oxidation peak current of DA compared to bare CILE. Using square wave voltammetry, the modified CILE showed good electrochemical behavior to DA, a linear range of 1.0×10?7–3.0×10?4 M in the presence of 1 mM ascorbic acid (AA) and a detection limit of 5.0×10?9 M was estimated (S/N=3).  相似文献   

17.
Electrochemically polymerized luminol film on a glassy carbon electrode (GCE) surface has been used as a sensor for selective detection of uric acid (UA) in the presence of ascorbic acid (AA) and dopamine (DA). Cyclic voltammetry was used to evaluate the electrochemical properties of the poly(luminol) film modified electrode. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) have been used for surface characterizations. The bare GCE failed to distinguish the oxidation peaks of AA, DA and UA in phosphate buffer solution (pH 7.0), while the poly(luminol) modified electrode could separate them efficiently. In differential pulse voltammetric (DPV) measurements, the modified GCE could separate AA and DA signals from UA, allowing the selective determination of UA. Using DPV, the linear range (3.0×10?5 to 1.0×10?3 M) and the detection limit (2.0×10?6 M) were estimated for measurement of UA in physiological condition. The applicability of the prepared electrode was demonstrated by measuring UA in human urine samples.  相似文献   

18.
In this study, the fluorescent carbon dots (CDs) of good biocompatibility and low toxicity was prepared by a carbonation route, and a strong enhancement effect of CDs on the luminol-K3Fe(CN)6 chemiluminescence (CL) system was observed. 5?±?1?nm CDs were used as catalysts to enhance the reaction sensitivity. In the presence of 2-methoxyestradiol (2-ME), the CL intensity of CDs-luminol-K3Fe(CN)6 was significantly inhibited. The relative CL intensity was linearly related to the 2-ME concentration in the range of 1.0?×?10?9 –1.0?×?10?7?g?mL-1 with a lower detection limit of 4.1?×?10?10?g?mL?1. As a preliminary application, the highly sensitive method was successfully applied to the determination of 2-ME in both pharmaceutical preparation and serum samples with satisfactory results. The possible mechanism of CL reaction catalyzed by CDs was investigated and the CDs played a role of catalyst in the reaction which could promote the generation of oxygen radicals.

It could be concluded that the enhancement effect on CL by CDs was attributed to the formation of oxygen radicals. The oxidation reaction of luminol was accelerated by oxygen radicals, which led to the enhanced CL emission.  相似文献   

19.
The electrochemiluminescence (ECL) of luminol in aqueous alkaline solution was studied.Trace amounts of chloride showed significant effect on the efficiency of light emission of luminol as a posi-tive trigonometrical wave pulse was exerted on the solution. The detection limit for the chloride is5.0 ×10~(-6) mol/L and the linear calibration range extends up to 1.0 ×10~(-2) mol/L; the relative standarddeviation for 1.0 ×10~(-5) mol / L chloride is 5%. The influencing factors for chloride determination arealso discussed. The possible mechanism for the electrochemiluminescence reaction may be due to theoxidation of chloride ion in the solution to ClO~-, and the latter acts on luminol and then gives outluminescence. The method has been applied to determine the total chloride in tap water with satisfactoryresults.  相似文献   

20.
A rapid, sensitive and reproducible method is described for the analysis of levodopa and its metabolite dopamine (DA) in human blood. The influence of carbidopa as the inhibitor againist the decarboxylase activity on the metabolism has been also studied. After derivatization in a dark pulsator for 12 h at room temperature, the fluorescein isothiocyanate (FITC) derivative of levodopa and other components were separated by capillary zone electrophoresis (CZE) within 13 min and detected with laser-induced fluorescence (LIF). Under the optimum analysis conditions, the linear range is 3.0×10-8—4.0×10-6 mol/L and 1.0×10-8—2.0×10-6 mol/L for levodopa and DA, respectively. The detection limits of levodopa and DA were 7.8×10-9 mol/L (39.0 amol) and 3.1×10-9 mol/L (15.5 amol), respectively. The method was successfully applied to monitoring the levodopa and DA in human blood after one took tablets orally.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号