首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 145 毫秒
1.
22‐[N(?7‐Nitrobenz‐2‐oxa‐1,3‐diazol‐4‐yl)amino]‐23,24‐bisnor‐5‐cholen‐3β‐ol (NBD‐cholesterol), a fluorescent cholesterol analog, was an extragenous cholesterol tracer used to study cholesterol absorption and metabolism in cultured cells. In order to measure free intracellular cholesterol and its esters, a precise and sensitive method employing high‐performance liquid chromatography/fluorescence detection (HPLC‐FLD) was developed for the first time. Method validation showed a limit of detection at 30 ng/mL. The calibration curve was linear within the range of 0.0625–10.0 µg/mL (r2 = 0.999). Accuracy and precision were highlighted by good recovery and low variations. Apart from NBD‐cholesteryl oleate, two additional cellular metabolites of NBD‐cholesterol, probably an isomer and an oxidation product, were determined in the lipid extracts of Caco‐2 human colon adenocarcinoma cells according to mass spectrometry. In AC29 mouse malignant mesothelioma cells overexpressing acyl‐CoA:cholesterol acyltransferase‐1 (ACAT1) or ACAT2, only the oxidized metabolite was detected. Using the newly developed method, YIC‐C8‐434, a known ACAT inhibitor, was shown to inhibit ACAT activity in Caco‐2 cells, as well as in AC29/ACAT1 or AC29/ACAT2 cells. In conclusion, the sensitive and specific HPLC‐FLD method is a powerful tool for simultaneous quantification of intracellular NBD‐cholesterol and its oleoyl‐ester. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Acyl‐CoA:cholesterol acyltransferase (E.C.2.3.1.26, ACAT) is a microsomial enzyme that catalyses the formation of cholesteryl esters by acylation of cholesterol with long chain fatty acylCoA [1]. ACAT plays important roles in cellular homeostasis and in the early stages of atherosclerosis. Therefore, ACAT inhibitors have been identified as useful agents in the treatment of hypercholesterolemia, atherosclerosis and coronary diseases [2]. In addition, recently their application has been proposed for Alzheimer's disease [3].  相似文献   

3.
A high‐performance liquid chromatography method for temozolomide (TMZ) determination in complex biological matrices was developed and validated for application in in vitro, ex vivo and in vivo studies of new nanotechnology‐based systems for TMZ nasal delivery. The method was able to quantify TMZ in nanoemulsions, following cellular uptake, in the porcine nasal mucosa and in mouse plasma and brain. Analyses were performed on a C18 column at 35°C, under UV detection at 330 nm. The mobile phase was methanol–acetic acid 0.5% (30:70, v/v), eluted at an isocratic flow rate of 1.1 mL/min. The method was found to be specific, precise, accurate, robust and linear (0.05 to 5 μg/mL) for TMZ determination in all matrices. No interference of TMZ degradation products was found under various stress conditions such as acidic, alkaline, oxidative, light and thermal exposure, demonstrating stability. The method was applied for the quantification of TMZ in different matrices, i.e. the efficiency of nanoemulsions in vitro in increasing TMZ cellular uptake, ex vivo TMZ permeation and retention in the porcine nasal mucosa tissue, and for in vivo TMZ quantification in mouse brain following intranasal nanoemulsion administration compared with free TMZ.  相似文献   

4.
Costunolide and dehydrocostuslactone are well‐known sesquiterpene lactones contained in many plants used as popular herbs, such as Saussurea lappa and Laurus novocanariensis, and have been considered as potential candidates for the treatment of various types of tumor. In the present work, a sensitive UPLC‐MS/MS for the quantification of costunolide and dehydrocostuslactone in biological matrices has been developed. The method is based on protein precipitation with acetonitrile followed by isocratic ultraperformance liquid chromatographic separation using methanol–formic acid (0.1% in water; 70:30, v/v) mobile phase. Detection was performed by ESI mass spectrometry in MRM mode with the precursor‐to‐product ion transitions m/z 233–187 and m/z 231–185, respectively. The calibration curves of analytes showed good linearity within the established range 0.19–760 ng/mL for costunolide and 0.23–908 ng/mL for dehydrocostuslactone. The lower limits of quantification of costunolide and dehydrocostuslactone were found to be 0.19 and 0.23 ng/mL, respectively. The intra‐day and inter‐day presicions of this method for the entire validation were less than coefficient of variation of 7% and the accuracy was within ±8% (relative error). The mean extraction recoveries were 73.8 and 75.3%, respectively. The method was found to be precise, accurate and specific during the study, and was successfully used to analyze the pharmacokinetics of costunolide and dehydrocostuslactone. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, sensitive and reliable LC–MS/MS method was developed and validated for the quantification of anemoside B4, a potential antiviral constituent isolated from Pulsatilla chinensis in rat plasma, tissue, bile, urine and feces. All biological samples were prepared by protein precipitation method, and ginsenoside‐Rg1 was chosen as the internal standard (IS). The analyte and IS were separated using a C18 column (2.1 × 50 mm, 1.8 μm) and a mobile phase consisting of 0.1% formic acid in water (v /v) and acetonitrile running at a flow rate of 0.2 mL/min for 5 min. The multiple reaction monitoring transitions were monitored at m /z 1219.5–749.5 for anemoside B4 and 845.4–637.4 for ginsenoside‐Rg1 in electrospray ionization negative mode. The calibration curve was linear in the range of 10–2000 ng/mL for all biological matrices with a lower limit of quantification of 10 ng/mL. The validated method was successfully applied to a pharmacokinetics, tissue distribution and excretion study. These preclinical data will be beneficial for further development of anemoside B4 in future studies.  相似文献   

6.
A simple, sensitive, selective and precise high‐performance thin‐layer chromatographic method was developed for determination of lipid A (MPLA) adjuvant as a bulk and in solid fat nanoemulsions. Chromatographic separations were performed on thin‐layer chromatography aluminum plates precoated with silica gel 60 F‐254 as stationary phase and chloroform–methanol–ethyl acetate solution (10:2:4, v/v/v) as mobile phase. With this solvent system, compact spots for MPLA at Rf value 0.80 ± 0.02 were obtained. Densitometric analysis of MPLA was carried out in absorbance mode at 357 nm. Linear regression analysis for the calibration plots showed good linear relationship with r = 0.9996 in the concentration range of 20–100 ng/spot. The mean values (±SD) of slope and intercept were found to be 7.355 ± 0.006 and 109.52 ± 0.170, respectively. Limits of detection (LOD) and quantitation (LOQ) were observed at 3.096 and 9.382 ng/spot, respectively.The method was validated for precision, accuracy, robustness and recovery as per the International Conference on Harmonization guidelines. Statistical analysis proved that the developed method for quantification of MPLA as a bulk and in solid fat nanoemulsions is reproducible, selective and economical. This method could be applied for quantitative assay of MPLA in lipid‐based vaccine formulations. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
A sensitive, rapid, and simple high‐performance liquid chromatography with UV detection method was developed for the simultaneous determination of seven phthalic acid esters (dimethyl phthalate, dipropyl phthalate, di‐n‐butyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di‐(2‐ethylhexyl) phthalate, and di‐n‐octyl phthalate) in several kinds of beverage samples. Ultrasound and vortex‐assisted dispersive liquid–liquid microextraction method was used. The separation was performed using an Intersil ODS‐3 column (C18, 250 × 4.6 mm, 5.0 μm) and a gradient elution with a mobile phase consisting of MeOH/ACN (50:50) and 0.2 M KH2PO4 buffer. Analytes were detected by a UV detector at 230 nm. The developed method was validated in terms of linearity, limit of detection, limit of quantification, repeatability, accuracy, and recovery. Calibration equations and correlation coefficients (> 0.99) were calculated by least squares method with weighting factor. The limit of detection and quantification were in the range of 0.019–0.208 and 0.072–0.483 μg/L. The repeatability and intermediate precision were determined in terms of relative standard deviation to be within 0.03–3.93 and 0.02–4.74%, respectively. The accuracy was found to be in the range of –14.55 to 15.57% in terms of relative error. Seventeen different beverage samples in plastic bottles were successfully analyzed, and ten of them were found to be contaminated by different phthalic acid esters.  相似文献   

8.
The purpose of this paper is to introduce a novel hollow fiber stir bar sorptive extraction for collecting and determining of phthalic acid esters in environmental and biological matrices. Shell–core ZrO2/SiO2 composite microspheres and porous C18 silica microspheres were compared as the sorbents, which were loaded in the lumen of a microporous hollow fiber membrane. A thin stainless‐steel wire was also inside of the hollow fiber membrane acting as the magnetic stirrer, thus affording the procedures like stir bar sorptive extraction to perform the active trapping of the analytes. Variables affecting the extraction (salt addition and pH of samples, extraction temperature, and time) and desorption (microwave time and eluted solvents) have been optimized. Under the optimal conditions, good linearity (r > 0.9968) of all calibration curves was obtained in validation experiments. And the limits of quantification ranged from 0.01 to 1000 ng/mL. The recoveries in different matrices were in the range of 64.90–112.60% with relative standard deviations less than 8.60%. The present work demonstrated the applicability of the developed method for the determination of phthalic acid esters in environmental and biological sample, allowing the selective extraction of phthalate esters in complex samples with low consumption of organic solvents and no sample clean‐up.  相似文献   

9.
Vitex trifolia L. is an important Indian medicinal plant with diverse pharmacological properties. In a recent study, we reported the isolation and antitubercular activity evaluation of three new diterpenoids from its leaves; here we have developed a validated rapid, simple, precise, and accurate high‐performance TLC method for the simultaneous quantification of isolated diterpenoids in V. trifolia. Diterpenoids, 6α,7α‐diacetoxy‐13‐hydroxy‐8(9),14‐labdadien ( A ), 13‐hydroxy‐5(10),14‐halimadien‐6‐one ( B ), and 9‐hydroxy‐13(14)‐labden‐16,15‐olide ( C ) were separated on silica gel 60F254 high‐performance TLC plates using chloroform/acetone (98:2, v/v) as mobile phase. The quantitation of diterpenoids was carried out using densitometric reflection/absorption mode at 610 nm after postchromatographic derivatization using a vanillin/sulfuric acid reagent. A precise and accurate quantification can be performed for compounds A and B in the linear working concentration range of 333–1000 ng/band and for C in the range of 670–2000 ng/band with good correlations (r = 0.9984, 0.9991, and 0.9994, respectively). The method was validated for peak purity, precision, accuracy, robustness, LOD, and LOQ, as per the ICH guidelines. The method reported here is simple, reproducible and may be applied for the quantitative analysis of the above diterpenoids in the leaves of V. trifolia.  相似文献   

10.
A simple and rapid high‐performance thin‐layer chromatographic method was developed for the separation and determination of six flavonoids (rutin, luteolin‐7‐O‐β‐glucoside, chamaemeloside, apigenin‐7‐O‐β‐glucoside, luteolin, apigenin) and one coumarin, umbelliferone from chamomile plant samples and dietary supplements. The separation was achieved on amino silica stationary phase using dichloromethane/acetonitrile/ethyl formate/glacial acetic acid/formic acid (11:2.5:3:1.25:1.25 v/v/v/v/v) as the mobile phase. The quantitation of each compound was carried out using densitometric reflection/absorption mode at their respective absorbance maxima after postchromatographic derivatization using natural products reagent (1% w/v methanolic solution of diphenylboric acid‐β‐ethylamino ester). The method was validated for specificity, limits of detection and quantification, precision (intra‐ and interday) and accuracy. The limits of detection and quantification were found to be in the range from 6–18 and 16–55 ng/band for six flavonoids and one coumarin, respectively. The intra‐ and interday precision was found to be <5% RSD and recovery of all the compounds was >90%. The data acquired from high‐performance thin‐layer chromatography was processed by principal component analysis using XLSTAT statistical software. Application of principal component analysis and agglomerative hierarchial clustering was successfully able to differentiate two chamomiles (German and Roman) and Chrysanthemum.  相似文献   

11.
A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method for the simultaneous determination of spirotetramat and its four metabolite residues in citrus, peel, pulp and soil was developed and validated by liquid chromatography with tandem mass spectrometry (LC‐MS/MS). The samples were extracted with acetonitrile (1%, glacial acetic acid, v/v) and purified using primary secondary amine and octadecylsilane. The limit of detection was 0.01–0.13 mg/kg, whereas that of quantification was 0.02–0.40 mg/kg for spirotetramat and its metabolites. The average recoveries of spirotetramat, spirotetramat‐enol, spirotetramat‐mono‐hydroxy, spirotetramat‐enol‐glucoside and spirotetramat‐ketohydroxy in all matrices were 73.33–107.91%, 75.93–114.85%, 76.44–100.78%, 71.46–103.19% and 73.08–105.27%, respectively, with relative standard deviations < 12.32%. The dissipation dynamics of spirotetramat in citrus and soil followed first‐order kinetics, with half‐lives of 2.3–8.5 days in the three sampling locations. The terminal residues of spirotetramat in four matrices at the three locations were measured below the 1.0 mg/kg maximum residue limit set by China, and residues were found to be concentrated on the peel. The risk assessment of citrus was evaluated using risk quotients. The risk quotient values were found to be significantly <1, suggesting that the risk to human health was negligible when using the recommended doses of spirotetramat in citrus. These results could provide guidance for the safe and proper application of spirotetramat in citrus in China.  相似文献   

12.
Recently, in silico models have been developed to predict drug pharmacokinetics. However, before application, they must be validated and, for that, information about structurally similar reference compounds is required. A chiral liquid chromatography method with ultraviolet detection (LC‐UV) was developed and validated for the simultaneous quantification of BIA 2–024, BIA 2–059, BIA 2–265, oxcarbazepine, eslicarbazepine (S‐licarbazepine) and R‐licarbazepine in mouse plasma and brain. Compounds were extracted by a selective solid‐phase extraction procedure and their chromatographic separation was achieved on a LiChroCART 250–4 ChiraDex column using a mobile phase of water–methanol (92:8, v/v) pumped at 0.7 mL/min. The UV detector was set at 235 nm. Calibration curves were linear (r2 ≥ 0.996) over the concentration ranges of 0.2–30 µg/mL for oxcarbazepine, eslicarbazepine and R‐licarbazepine; 0.2–60 µg/mL for the remaining compounds in plasma; and 0.06–15 µg/mL for all the analytes in brain homogenate. Taking into account all analytes at these concentration ranges in both matrices, the overall precision did not exceed 9.09%, and the accuracy was within ±14.3%. This LC‐UV method is suitable for carrying out pharmacokinetic studies with these compounds in mouse in order to obtain a better picture of their metabolic pathways and biodistribution. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
A simple and fast analytical procedure for separation and purification of cholesteryl esters of human serum is described. A single lipid extract, together with spiked cholesteryl pentadecanoate, as an internal standard, was passed through a Silica Sep-Pak cartridge. 1.5% diethyl ester in light petroleum was used to elute cholesteryl esters from the column. The separation was verified with thin-layer chromatography on silica gel using light petroleum-diethyl ether-glacial acetic acid (80:20:1) as a solvent. A very clean thin-layer chromatogram of cholesteryl esters without any additional spots of other lipids was obtained. The cholesteryl esters were quantitated by analyzing their fatty acid composition as methyl esters by gas-liquid chromatography. The coefficients of variation were 0.8--4.9% for the major fatty acids (C16:0, C16:1, C18:1, C18:2, C20:4) and 6.7--30.8% for the minor fatty acids (C18:0 and C20:0). The recoveries for cholesteryl palmitate, cholesteryl oleate and cholesteryl linoleate were 90.7, 92.3 and 91.0%, respectively.  相似文献   

14.
Afatinib (AFT) is a new tyrosine kinase inhibitor approved for the treatment of nonsmall cell lung cancer. In the present study, a simple, specific, rapid and sensitive liquid chromatography tandem mass‐spectrometric method for the quantification of AFT in human plasma, was developed and validated. Chromatographic separation of the analytes was accomplished on a reversed‐phase Luna®‐PFP 100 Å column (50 × 2.0 mm; 3.0 μm) maintained at ambient temperature. Isocratic elution was carried out using acetonitrile–water (40:60, v/v) containing 10 mm ammonium formate buffer (pH 4.5) adjusted with formic acid at a flow rate of 0.4 mL min?1. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring mode. The method yields a linear calibration plot (r2 = 0.9997) from a quantification range of 0.5–500 ng mL?1 with the lower limit of quantification and lower limit of detection of 1.29 and 0.42 ng mL?1, respectively. The intra‐ and inter‐day precision and accuracy were estimated and found to be in the ranges of 1.53–4.11% for precision and ?2.80–0.38% for accuracy. Finally, quantification of afatinib in a metabolic stability study in rat liver microsomes was achieved through the proposed method. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
A number of fatty acid ethyl esters (FAEEs) have recently been detected in meconium samples. Several of these FAEEs have been evaluated as possible biomarkers for in utero ethanol exposure. In the present study, a method was optimized and validated for the simultaneous determination of eight FAEEs (ethyl laurate, ethyl myristate, ethyl palmitate, ethyl palmitoleate, ethyl stearate, ethyl oleate, ethyl linoleate and ethyl arachidonate) in meconium samples. FAEEs were extracted by headspace solid‐phase microextraction. Analyte detection and quantification were carried out using GC‐MS operated in chemical ionization mode. The corresponding D5‐ethyl esters were synthesized and used as internal standards. The LOQ and LOD for each analyte were <150 and <100 ng/g, respectively. The method showed good linearity (r2>0.98) in the concentration range studied (LOQ – 2000 ng/g). The intra‐ and interday imprecision, given by the RSD of the method, was lower than 15% for all FAEEs studied. The validated method was applied to 63 authentic specimens. FAEEs could be detected in alcohol‐exposed newborns (>600 ng/g cumulative concentration). Interestingly, FAEEs could also be detected in some non‐exposed newborns, although the concentrations were much lower than those measured in exposed cases.  相似文献   

16.
Lithium salts of organic aromatic acids (lithium benzoate, lithium salicylate, lithium vanillate, lithium 2,5‐dimethoxybenzoate, lithium 2,5‐dihydroxyterephthalate, lithium α‐cyano‐4‐hydroxycinnamate and lithium sinapate) were synthesized and tested as potential matrices for the matrix‐assisted laser desorption/ionization (MALDI)‐mass spectrometry analysis of hydrocarbons and wax esters. The analytes were desorbed using nitrogen laser (337.1 nm) and ionized via the attachment of a lithium cation, yielding [M + Li]+ adducts. The sample preparation and the experimental conditions were optimized for each matrix using stearyl behenate and n‐triacontane standards. The performance of the new matrices in terms of signal intensity and reproducibility, the mass range occupied by matrix ions and the laser power threshold were studied and compared with a previously recommended lithium 2,5‐dihydroxybenzoate matrix (LiDHB) (Cva?ka and Svato?, Rapid Commun. Mass Spectrom. 2003, 17, 2203). Several of the new matrices performed better than LiDHB. Lithium vanillate offered a 2–3 times and 7–9 times higher signal for wax esters and hydrocarbons, respectively. Also, the signal reproducibility improved substantially, making this matrix a suitable candidate for imaging applications. In addition, the diffuse reflectance spectra and solubility of the synthesized compounds were investigated and discussed with respect to the compound's ability to serve as MALDI matrices. The applicability of selected matrices was tested on natural samples of wax esters and hydrocarbons. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
An efficient enantioselective method for the determination of etoxazole in orange pulp, peel, and whole orange was developed using liquid chromatography with tandem mass spectrometry. The enantioseparation was performed on a Chiralpak AD‐3R column at 30ºC using acetonitrile with 0.1% formic acid solution (80:20, v/v) as the mobile phase in less than 5 min. Quantification was achieved using matrix‐matched standard calibration curves. The overall mean recoveries for two enantiomers from orange pulp and whole orange were 91.0–99.6% and the orange peel was 92.6–103.1%, with relative standard deviations of 0.8–5.4% intraday and 2.0–4.8% interday at 1, 10, and 100 μg/kg levels, and 1.3–5.2% intraday and 3.5–4.3% interday at 5, 50, and 500 μg/kg levels, respectively. The limits of quantification for all enantiomers in three matrices did not exceed 5 μg/kg. Moreover, the absolute configuration of etoxazole enantiomers had been determined by the combination of experimental and predicted electronic circular dichroism spectra, and the first eluted enantiomer was confirmed as (S)‐etoxazole on a Chiralpak AD‐3R column while (R)‐etoxazole was first on three cellulose chiral columns. The application of the proposed method to real sample analysis suggests its potential use in enantioselective determination of etoxazole enantiomers in citrus.  相似文献   

18.
Thirteen polycyclic aromatic hydrocarbons have been determined in soy‐based nutraceutical products. First, an optimization of extraction procedure was performed, and a solid–liquid extraction assisted by sonication and a dilute and shoot procedure were compared, selecting the dilute and shoot approach for the extraction of target compounds, utilizing a mixture of acetone/n‐hexane (1:1 v/v) as extractant solvent. After this, a clean‐up step was needed bearing in mind the complexity of these matrices. Dispersive solid‐phase extraction, using a mixture of C18 and Zr‐Sep+ (25 mg/mL each) was used. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. For quantification purposes, matrix‐matched calibration was used. The validation was applied at three concentration levels (20, 100 and 250 μg/kg), obtaining recoveries between 70 and 120% and precision values equal to or lower than 23%. Limits of detection and quantification were below 8 and 20 μg/kg, respectively. The method was applied in 11 samples, detecting five polycyclic aromatic hydrocarbons at concentrations ranging from 4.1 to 18.5 μg/kg.  相似文献   

19.
The radical-dependent oxidation of unsaturated fatty acids is a fundamental reaction in lipid chemistry, biochemistry, and technology. We report herein the first successful application of 1H–13C HMBC NMR experiment for the identification and quantification of complex and minor (3.9% to 0.85%) components of cis and trans primary hydroperoxide isomers of oxidized oleate and linoleate methyl esters in solution, without the need of laborious isolation of the individual components.  相似文献   

20.
A chiral liquid chromatographic method was developed and validated for the quantification of R‐enantiomer impurity (RE) in WCK 3023 (S‐enantiomer), a new drug substance. The separation was achieved on Chiralpak IA (amylose‐based immobilized chiral stationary phase), using a mobile phase consisting of n‐hexane–ethanol–trifluoroacetic acid (70:30:0.2, v/v/v) at a flow rate of 1.0 mL/min. The method was extensively validated for the quantification of RE in WCK 3023 and proved to be robust. For RE the detector response was linear over the concentration range of 0.11–5 μg/mL. The limit of quantitation and limit of detection for RE were 0.11 and 0.04 μg/mL respectively. Average recovery of the RE was in the range of 98.11–99.55%. The developed method was specific, sensitive, precise and accurate for quantitative determination of RE in WCK 3023. The impact of thermodynamic parameters on the chiral separation was evaluated. The method was employed for controlling the enantiomeric impurity in the lots of WCK 3023 used for pre‐clinical studies. The method was successfully applied to evaluate the possible conversion of WCK 3023 to RE in rat serum samples during pre‐clinical pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号