A novel, specific and sensitive ultraperformance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed for the simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma. The method involves a simple, one‐step extraction procedure coupled with an Acquity UPLC? BEH C18 column (100 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.2 mL/min and lisinopril as the internal standard. Detection was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Using 250 µL plasma, the methods were validated over the concentration range 5.010–500.374 ng/mL for quinapril and 10.012–1000 ng/mL for quinaprilat, with a lower limit of quantification of 5.010 ng/mL for quinapril and 10.012 ng/mL for quinaprilat. The intra‐ and inter‐day precision and accuracy were within 10.0%. The recovery was 85.8, 62.6 and 61.3% for quinapril, quinaprilat and lisinopril, respectively. Total run time was 3.0 min only. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
A rapid, specific and sensitive ultra‐performance liquid chromatography tandem mass spectrometry method was developed for the determination of fenofibric acid in human plasma. The method involves simple, one‐step liquid–liquid extraction procedure coupled with an Acquity UPLCTM BEH C18 column (50 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.2 mL/min and mefenamic acid was used as the internal standard. The Quattro Premier XE mass spectrometry was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. Using 250 µL plasma, the methods were validated over the concentration rang 0.05–7.129 µg/mL, with a lower limit of quantification of 0.05 µg/mL. The intra‐ and inter‐day precision and accuracy were within 9.3%. The recovery was 66.7% and 52.6% for fenofibric acid, and mefenamic acid, respectively. Total run time was 1.8 min only for each sample, which makes it possible to analyze more than 350 samples per day. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid, sensitive and rugged solid‐phase extraction ultra performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method was developed for determination of paroxetine in human plasma. The procedure for sample preparation includes simple SPE extraction procedure coupled with Hypersil Gold C18 column (100 mm ? 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow‐rate of 0.350 mL/min and fluoxetine was used as the internal standard. The analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reactions monitoring mode via electrospray ionization. Using 500 μL plasma, the methods were validated over the concentration range 0.050–16.710 ng/mL for paroxetine, with a lower limit of quantification of 0.050 ng/mL. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recovery was 69.2 and 74.4% for paroxetine and fluoxetine respectively. Total run time was only 1.9 min. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Self‐poisoning with pesticides accounts for approximately one‐third of all suicides worldwide. To expedite rescue in the emergency department, it is essential to develop a point‐of‐care analytical method for rapid identification of ingested pesticides. In this study, five of the most common pesticides ingested by self‐poisoning patients in Taiwan were analyzed from oral fluid samples. Pesticide‐oral fluid mixtures were applied on a cotton swab and then transferred into methanol. A metallic probe was used to sample the methanol solution for subsequent thermal desorption‐electrospray ionization mass spectrometry analysis. Altogether, pesticide sampling, transfer, desorption, ionization, and detection took less than 1 min. The reproducibility of this method (n = 6) was shown in the observed low‐relative standard deviation (<7%) in the detection of pesticide in oral fluid. The detection limits of the pesticides in oral fluid obtained from four human subjects by thermal desorption‐electrospray ionization mass spectrometry were between 1–10 ppb with relative standard deviation 10.7%. Moreover, in this study, linear responses of five pesticides in oral fluid with concentrations between 1 ppb–1 ppm (R2 between 0.9938 and 0.9988) were observed. As the whole analytical process is extremely short, this technique allows for early non‐invasive point‐of‐care identification of pesticides in the oral fluid of self‐poisoning patients in the emergency room, providing important toxicological information for decision‐making during critical resuscitation. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
Drugs deposited in human teeth are well preserved; the spectrum of toxicological investigations may therefore be supplemented by an analysis method for drugs in teeth. A liquid chromatography–electrospray ionization tandem mass spectrometry assay for the detection and quantification of basic drugs of abuse in bovine dentin samples was developed and validated. The drugs and metabolites amphetamine, methamphetamine, methylenedioxymethylamphetamine, methylenedioxyethylamphetamine, codeine, morphine, cocaine and benzoylecgonine were extracted from 50 mg ground dentin powder by ultrasonication for 60 min in methanol 3 times. The extracts were analyzed on a triple‐quadrupole mass‐spectrometer in multiple reaction monitoring mode. The method was validated and proved to be accurate, precise, selective, specific and stable with good linearity within the calibration range and a lower limit of quantification of 10 to 20 pg/mg. To artificially load bovine dentin samples with drugs, the natural process of de‐ and remineralization in the oral cavity was mimicked by a pH‐cycling experiment. The artificially drug‐loaded dentin samples showed drug concentrations of 20 to 80 pg/mg. The method can be applied in further in vitro experiments as well as in post‐mortem cases, especially where limited sample tissue is available. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC‐MS/MS) was developed for the determination of pseudo‐ginsenoside GQ in human plasma. Liquid–liquid extraction was used to isolate the analyte from biological matrix followed by injection of the extracts onto a C8 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer (API‐4000 system) in multiple reaction monitoring mode using negative electrospray ionization. The mobile phase consisted of methanol–10 mm ammonium acetate (90:10, v/v) and the flow rate was 0.3 mL/min. The method was validated over the concentration range of 5.0–5000.0 ng/mL for plasma. Inter‐ and intra‐day precisions (relative standard deviation) were all within 15% and the accuracy (relative error) was ≤9.4%. The lower limit of quantitation was 5.0 ng/mL. The pseudo‐ginsenoside GQ was stable after 8 h at room temperature, 24 h at autosampler and three freeze–thaw cycles (from ?30 to 25 °C). The method was successfully applied to the pharmacokinetic study of pseudo‐ginsenoside GQ in healthy Chinese volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Silver-phase chromatography hyphenated with on-line electrospray mass spectrometry can be applied to characterize triacylglycerols present in vegetable oils with respect to their degree of unsaturation, the position of the most unsaturated fatty acid and the carbon number (CN). The CN information obtained with silver-phase HPLC–ESP–mass spectrometry is complementary to the unsaturation information obtained by silver-phase HPLC-flame ionization detection. Both information is essential to monitor or study modified vegetable oils on the presence of non-natural triacylglycerols. The quantitative results obtained with the method are in agreement with the results obtained in the silver-phase HPLC-flame ionization detection and with theoretical values calculated from the fatty acid distribution of the oil. Silver-phase HPLC–ESP-mass spectrometry gives direct information on fatty acid position and triacylglycerol CN, for each of the triacylglycerols in the sample. This in contrast with non-aqueous reversed-phase HPLC hyphenated with on-line atmospheric pressure chemical ionization-mass spectrometry, which requires a more extensive data processing. The results obtained with silver-phase HPLC–ESP-mass spectrometry can be presented in a three-dimensional overview (relative amount, CN, fatty acid position) serving as a fingerprint for the oil.  相似文献   

8.
Due to the varying toxicity the species of organotins in their widespread applications, it is important for analytical methods to address their speciation. Traditional methods call for the hydrolysis and subsequent derivatization of the organotins before analysis. These methods can be time‐consuming, derivatization can be incomplete and high levels of background interference produce difficulties in identification and quantification. The use is described of a non‐derivatization and non‐hydrolysis micro‐liquid chromatography–electrospray/ion trap mass spectrometry for separation and detection of the organotins. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

9.
周卫军  谢正福  邵琳智 《色谱》2012,30(7):684-689
采用高效液相色谱-串联质谱技术,建立了口腔卫生产品(牙膏及漱口水)中5类共13种抗生素的同时检测方法。分析物包括5种四环素类、3种大环内酯类、2种喹诺酮类、1种β-内酰胺类和2种林可胺类抗生素。样品经0.1%(体积分数,下同)甲酸溶液-乙腈(95:5, v/v)提取,高速离心并过滤,稀释后采用C18色谱柱(150 mm×2.1 mm, 5 μm)分离,以0.1%甲酸溶液-乙腈为流动相梯度洗脱,采用电喷雾离子源串联质谱,在正离子扫描方式下以多反应监测(MRM)模式检测,外标法定量。13种抗生素类药物在5.0~50.0 μg/L质量浓度范围内线性关系良好(相关系数大于0.99),定量限为10.0 mg/kg。两种基质(牙膏及漱口水)样品在10、20和100 mg/kg 3个加标水平下的平均回收率为80.1%~115%,相对标准偏差为0.94%~8.69%。该方法准确可靠、方便快捷,适用于口腔卫生产品中抗生素类药物的定性定量分析。  相似文献   

10.
11.
唐圣芸  王远兴  温平威  辛贞 《色谱》2014,32(2):184-188
建立了高效液相色谱-电喷雾串联质谱(HPLC-ESI-MS/MS)测定饲料中N-氨基甲酰-L-谷氨酸(NCG)含量的方法。饲料样品经甲醇提取、混合型强阴离子交换反相固相萃取(PXA)柱净化、HPLC分离后,采用ESI-MS/MS在正离子多反应监测(MRM)模式下进行检测,以碎片离子m/z 148.0和m/z 84.0进行定性,以碎片离子m/z 130.0进行定量。NCG的检出限(S/N >3)为24 μg/kg,定量限(S/N >10)为80 μg/kg,在20~1000 μg/L的质量浓度范围内峰面积与含量的线性关系良好,相关系数为0.9999。对饲料中NCG在80、200、500 mg/kg等3个添加水平下的回收率进行了测定,分别为104.0%、103.5%、95.3%,相对标准偏差分别为7.5%、6.3%、5.8%。结果表明,该方法操作简单,净化效果好,快速,灵敏度和准确度高,符合对饲料样品中NCG检测分析的要求。  相似文献   

12.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

13.
A sensitive and simple liquid chromatography–tandem mass spectrometric (HPLC‐MS/MS) method for the determination of corilagin in rat plasma has been developed. Samples were prepared with protein precipitation method and analyzed with a triple quadrupole tandem mass spectrometer. We employed negative electrospray ionization as the ionization source and the analytes were detected in multiple reaction monitoring mode. Separation was achieved on a C8 column eluted with mobile phase consisting of methanol–0.1% formic acid in a gradient mode at the flow rate of 0.3 mL/min. The total run time was 7.0 min.This method was proved to have good linearity in the concentration range of 2.5–1000.0 ng/mL. The lower limit of quantification of corilagin was 2.5 ng/mL. The intra‐ and inter‐day relative standard deviationa across three validation runs for four concentration levels were both <9.8%. The relative error was within ±6.0%. This assay offers advantages in terms of expediency and suitability for the analysis of corilagin in rat plasma. The practical utility of this new HPLC‐MS/MS method was confirmed in pilot plasma concentration studies in rats following oral administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
The aim of this study was to develop a rapid and sensitive method for the quantification of cefquinome in animal plasma and bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography combined with electrospray tandem mass spectrometry (LC-ESI-MS/MS). Cefadroxil is used as internal standard. For plasma, the sample preparation includes a simple deproteinization step with a Microcon filter. This allows detecting the unbound cefquinome concentration, which is correlated with the concentration in other body fluids, such as BAL fluid. To be able to detect the total plasma concentration, deproteinization with acetonitrile, followed by a back-extraction of actonitrile with dichloromethane was performed. The BAL fluid is centrifuged to precipitate floating particles. Chromatographic separation is achieved on a PLRP-S column using 0.005% formic acid and methanol as mobile phase. For plasma, good linearity was observed in the range of 5-2500 ng ml(-1) for both the unbound and total concentration. The response in BAL fluid was linear in the range of 4-1000 ng ml(-1). The limit of quantification (LOQ) was set at 5.00 ng ml(-1) for plasma and at 4.00 ng ml(-1) for BAL fluid. The limit of detection (LOD) was 3.12 ng ml(-1) and 0.41 ng ml(-1) for the unbound and total concentration in plasma, respectively, and was 1.43 ng ml(-1) for BAL fluid. The method was shown to be of use in a pharmacokinetic study in pigs, where the correlation between cefquinome concentrations in plasma and BAL fluid of pigs was studied.  相似文献   

15.
A high sensitive method for determination of cyclamate in foods by ion-pair high-performance liquid chromatography-electrospray ionization mass spectrometry was developed and validated. The separation was achieved on a C8 column with 5 mM tris(hydroxymethyl)aminomethane aqueous solution (pH 4.5, adjusted by acetic acid) as mobile phase with an isocratic mode. The quantification of target compound was completed using a selected ion recording (SIR) at m/z 178 obtained from ESI-mode. Tiopronin was used as internal standard for the quantification of cyclamate. The correlation coefficient of the calibration curve were better than 0.996, in the range of 50-5000 ng/mL. The limit of detection is 5 ng/mL, the limit of quantification is 20 ng/mL. The inter- and intra-day accuracy, precision were investigated in detail. The method can be used to monitor effectively the content of the artificial sweetener in foods. The method has obvious merits such as high sensitivity, specificity and simply versus other methods reported.  相似文献   

16.
Toosendanin (TSN) is a major triterpenoid existing in Melia toosendan, which has been used as a digestive tract parasiticide and insecticide but with serious hepatotoxicity. An ultra‐performance liquid chromatography–electrospray ionization–mass spectrometry method was developed for determination of TSN in rat plasma. Plasma samples were separated on Acquity UPLCTM BEH C18 column with acetonitrile and water as flow phase by gradient elution and determined by quadrupole mass spectrometer in negative selective ion monitoring mode. Usolic acid was used as internal standard. The calibration curves were linear over 0.02–3.0 µg/mL for TSN with a lower limit of quantification (LLOQ) of 20 ng/mL in rat plasma. The extraction recoveries of TSN were within 74.3–80.7% with an accuracy of 94.5–108.9%. The intra‐ and inter‐day precision values of the assay at three quality control levels were 8.8–13.8% and <13.9% at LLOQ level, respectively. The method was successfully applied to a pharmacokinetic study of TSN in rats after a single intravenous and oral administration of 2 and 60 mg/kg. The shorter Tmax, higher Vd and Cl of TSN after oral administration indicated that TSN could be absorbed, distributed and eliminated quickly in rats in vivo. The absolute bioavailability of TSN after oral administration was 9.9%. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
This study presents the atmospheric pressure photoionization (APPI) of high‐chlorinated (five or more chlorine atoms) polychlorinated biphenyls (PCBs) using toluene as dopant, after liquid chromatographic separation. Mass spectra of PCB 101, 118, 138, 153, 180, 199, 206 and 209 were recorded by using liquid chromatography‐APPI‐tandem mass spectrometry (LC‐APPI‐MS/MS) in negative ion full scan mode. Intense peaks appeared at m/z that correspond to [M ? Cl + O]? ions, where M is the analyte molecule. Furthermore, a detailed strategy, which includes designs of experiments, for the development and optimization of LC‐APPI‐MS/MS methods is described. Following this strategy, a sensitive and accurate method with low instrumental limits of detection, ranging from 0.29 pg for PCB 209 to 8.3 pg for PCB 101 on column, was developed. For the separation of the analytes, a Waters XSELECT HSS T3 (100 mm × 2.1 mm, 2.5 µm) column was used with methanol/water as elution system. This method was applied for the determination of the above PCBs in water samples (surface water, tap water and treated wastewater). For the extraction of PCBs from water samples, a simple liquid–liquid extraction with dichloromethane was used. Method limits of quantification, ranged from 4.8 ng l?1, for PCB 199, to 9.4 ng l?1, for PCB 180, and the recoveries ranged from 73%, for PCB 101, to 96%, for PCB 199. The estimated analytical figures were appropriate for trace analysis of high‐chlorinated PCBs in real samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A new method for the rapid and simultaneous detection of ketamine and its major metabolite, norketamine, in rat hair has been developed by combining micropulverized extraction and ultraperformance liquid chromatography–electrospray ionization mass spectrometry. By using reversed‐phase UPLC, ketamine and norketamine were well separated within 2 min. Using ketamine‐dosed rat hair, the conditions for micropulverized extraction were optimized, and the limits of detection and quantification of the developed method were found to be 1.7 and 5.7 pg/mg hair for ketamine, respectively. The precisions achieved with this method were slightly better than that obtained with conventional acidic methanol extraction method. Using this proposed method, analysis of the washed rat hair could be completed within 16–17 min. This method is expected to be applied for the analysis of the hair samples of not only rats but also ketamine abusers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   