首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of microwave assisted modification of the Akabori hydrazinolysis reaction has been found to cleave cyclic oligopeptides in a selective fashion to produce mainly the hydrazide of a specific linear peptide. This ring cleavage requires a few minutes of reaction in a domestic microwave oven. The linear peptide hydrazide can be analyzed by ESI-MS/MS, FAB-MS, and FAB-MS/MS methods for the determination of the amino acid sequence.  相似文献   

2.
Liquid chromatography/mass spectrometry (LC/MS) peptide maps have become a basic tool for characterizing proteins of biological and pharmaceutical interest. The ability to generate reproducible maps with high protein sequence coverage is a central goal of methods development. We have applied a recently developed analytical approach (termed LC/MS(E)) to LC/MS peptide mapping. Using the LC/MS(E) approach, the mass detector alternates between a low-energy scanning mode (MS) for accurate mass peptide precursor identification, and an elevated-energy mode (MS(E)) for generation of accurate mass multiplex peptide fragmentation data. In this paper, we evaluate this analytical approach against a tryptic digest of yeast enolase. From the low-energy data, high peptide map coverage (98% of sequence from peptides >3 amino acids) was reproducibly obtained. The MS signal for essentially equimolar peptides varied over 2 orders of magnitude in intensity, and peptide intensities could be precisely and reproducibly measured. Using the temporal constraint that MS(E) peptide fragment ions exhibit chromatographic profiles that parallel the precursor ions that generated them, we were able to produce accurate mass time-resolved MS/MS information for all enolase peptides with sufficient abundance to produce a detectable fragment ion.  相似文献   

3.
Product ions obtained by tandem mass spectrometry (MS/MS) are quite effective for the amino acid sequencing of linear peptides. However, in the case of cyclic peptides, the fragmentation pattern is complicated because the cleavages occur randomly and product ions are generated as a(n), b(n), c(n), x(n), y(n) and z(n) series ions; therefore, the authors have never obtained sufficient sequence information. In order to overcome this problem, we applied ion trap liquid chromatography/multi-stage mass spectrometry (LC/MS(n)) and characterized the product ions obtained from anabaenopeptins and aeruginopeptins as the cyclic peptides. For the anabaenopeptins, MS(2) analysis did not provide sufficient sequence information on the cyclic structure, and MS(3) analysis was applied to sequence the constituent amino acids. Diagnostic product ions were obtained by the MS(3) analysis and were quite effective for obtaining the sequence information of the constituent amino acids. MS(2) analysis was, however, sufficient to obtain the sequence information of the aeruginopeptins. In both cases, the resulting product ions obtained from the cyclic structures were formed by the two-bond fission mechanism of the precursor ion, in which an initial fission of the cyclic structure to a linear one and subsequent fission(s) at the peptide bonds are included. The fragmentations were similar for the structurally related compounds, indicating that the cleavages occurred at definite peptide bonds. In addition, the resulting product ions are generated as b(n) series ions and the mass difference facilitates the amino acid sequencing. Thus, ion trap LC/MS(n) provides sequence information, and the resulting product ions are reproducible among the structurally related compounds and reliable for the sequencing of the constituent amino acids of the cyclic structure.  相似文献   

4.
An algorithm for interpretation of product ion spectra of peptides generated from ion trap mass spectrometry is developed for de novo amino acid sequencing of peptides for the purpose of protein identification. It is based on a multi-pass analysis of product ion data using a rigorous data extraction and sequence interpretation protocol in the initial pass. The extraction/interpretation algorithm becomes more relaxed in subsequent passes, considering more of the fragment ions, and potentially more sequence candidates. The possible peptide sequences generated by the algorithm are scored according to those sequences which best explain the fragment ion spectrum. These sequences are searched against a protein database using a BLAST search engine to find likely protein candidates. The method is also suitable for locating and determining protein modifications, and can be applied to de novo interpretation of peptide fragment ions in the tandem mass (MS/MS) spectrum produced from a mixture of two peptides having similar nominal mass, but different sequences. Using a known protein, bovine serum albumin, as an example, it is illustrated that this method is rapid and efficient for MS/MS spectral interpretation. This method combined with BLAST programs is then applied to search homologies and to generate information on post-translational modifications of an unknown protein isolated from shark cartilage that does not have a complete genome or proteome database.  相似文献   

5.
Peptide retention time (RT) is independent of tandem mass spectrometry (MS/MS) parameters and can be combined with MS/MS information to enhance peptide identification. In this paper, we utilized peptide empirical RT and MS/MS for peptide identification. This new approach resulted in the construction of an Empirical Peptide Retention Time Database (EPRTD) based on peptides showing a false‐positive rate (FPR) ≤1%, detected in several liquid chromatography (LC)/MS/MS analyses. In subsequent experiments, the RT of peptides with FPR >1% was compared with empirical data derived from the EPRTD. If the experimental RT was within a specified time range of the empirical value, the corresponding MS/MS spectra were accepted as positive. Application of the EPRTD approach to simple samples (known protein mixtures) and complex samples (human urinary proteome) revealed that this method could significantly enhance peptide identification without compromising the associated confidence levels. Further analysis indicated that the EPRTD approach could improve low‐abundance peptides and with the expansion of the EPRTD the number of peptide identifications will be increased. This approach is suitable for large‐scale clinical proteomics research, in which tens of LC/MS/MS analyses are run for different samples with similar components. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

7.
An on-line coaxial continuous-flow capillary-zone electrophoresis/fast-atom bombardment mass spectrometry (CZE/FAB-MS) interface is described. This interface is shown to be capable of acquiring mass spectra in an on-line fashion from low femtomole amounts of peptides while maintaining high (hundreds of thousands of plates) electrophoretic separation efficiencies. Active electrophoretic transport of the analytes directly to the FAB probe tip obviates the need for a transfer line from the end of the CZE capillary to this point, and thereby precludes the zone broadening that would otherwise occur both within such a transfer line and in the connections between the CZE column and the transfer line. The capability of acquiring an on-line tandem mass spectrometry (MS/MS) spectrum of an electrophoretically separated analyte using this interface is also demonstrated.  相似文献   

8.
A method has been developed for rapid and sensitive identification of epitope-containing peptides, based on direct MALDI-MS/MS analysis of epitope-containing peptides affinity bound to affinity beads. This technique provides sequence information of the epitope that allows unambiguous identification of the epitope either by database searching or de novo sequencing. With MALDI-MS, affinity beads with bound peptides can be placed directly on the MALDI target and analyzed. Coupling a MALDI source to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer allows direct sequencing of the bound peptides. In contrast to ESI-MS/MS, elution of the affinity-bound peptides followed by additional concentration and purification steps is not required, thus reducing the potential for sample loss. Direct mass spectrometric sequencing of affinity-bound peptides eliminates the need for chemical or enzymatic sequencing. Other advantages of this direct MALDI-MS/MS analysis of epitope-containing peptides bound to the affinity beads include its sensitivity (femtomole levels) and speed. In addition, direct analysis of peptides on affinity beads does not adversely affect the high mass accuracy of a QqTOF, and database searching can be performed on the MS/MS spectra obtained. In proof-of-principle experiments, this method has been demonstrated on beads containing immobilized antibodies against phosphotyrosine, the c-myc epitope tag, as well as immobilized avidin. Furthermore, de novo sequencing of epitope-containing peptides is demonstrated. The first application of this method was with anti-FLAG-tag affinity beads, where direct MALDI MS/MS was used to determine an unexpected enzymatic cleavage site on a growth factor protein.  相似文献   

9.
Simple and efficient digestion of proteins, particularly hydrophobic membrane proteins, is of significance for comprehensive proteome analysis using the bottom-up approach. We report a microwave-assisted acid hydrolysis (MAAH) method for rapid protein degradation for peptide mass mapping and tandem mass spectrometric analysis of peptides for protein identification. It uses 25% trifluoroacetic acid (TFA) aqueous solution to dissolve or suspend proteins, followed by microwave irradiation for 10 min. This detergent-free method generates peptide mixtures that can be directly analyzed by liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) without the need of extensive sample cleanup. LC-MALDI MS/MS analysis of the hydrolysate from 5 microg of a model transmembrane protein, bacteriorhodopsin, resulted in almost complete sequence coverage by the peptides detected, including the identification of two posttranslational modification sites. Cleavage of peptide bonds inside all seven transmembrane domains took place, generating peptides of sizes amenable to MS/MS to determine possible sequence errors or modifications within these domains. Cleavage specificity, such as glycine residue cleavage, was observed. Terminal peptides were found to be present in relatively high abundance in the hydrolysate, particularly when low concentrations of proteins were used for MAAH. It was shown that these peptides could still be detected from MAAH of bacteriorhodopsin at a protein concentration of 1 ng/microl or 37 fmol/microl. To evaluate the general applicability of this method, it was applied to identify proteins from a membrane protein enriched fraction of cell lysates of human breast cancer cell line MCF7. With one-dimensional LC-MALDI MS/MS, a total of 119 proteins, including 41 membrane-associated or membrane proteins containing one to 12 transmembrane domains, were identified by MS/MS database searching based on matches of at least two peptides to a protein.  相似文献   

10.
N-Acetyl-N,O,S-permethylated derivatives of oligopeptides were analyzed by high-performance liquid chromatography-mass spectrometry (HPLC-MS) using a moving belt interface. A heated-gas nebulizer was employed for sample deposition, thus permitting the effective use of a water-methanol gradient covering the range from 5% to 95% water at mobile phase flow-rates of 0.5 ml/min. We demonstrate in this paper that it is possible to sequence the octapeptide derived from the C-chain of glucagon by HPLC-MS analysis of a permethylated enzymatic hydrolysate of this peptide using overlap information from the mass spectral patterns. Moreover, it is shown that peptides not readily amenable to analysis by gas chromatography-MS can be analyzed using this approach. Preliminary results suggest that N-acetyl-methyl ester derivatives of oligopeptides may in specific cases also be a useful alternative for HPLC-MS analysis of complex oligopeptide mixtures.  相似文献   

11.
A laser desorption Fourier transform mass spectrometric (LD/FTMS) method that uses both positive and negative ion LD/FT mass spectra obtained with collision-activated dissociation has been developed for analysis of oligopeptides. The technique is demonstrated using the model compound gramicidin D, for which the correct sequence is derived using only LD/FTMS information. Different relationships between positive and negative ion spectra are found for linear and cyclic oligopeptides.  相似文献   

12.
In a search for improved resolution of hydrogen/deuterium (H/D) exchange experiments analyzed by mass spectrometry (HXMS), we evaluated two methodologies for a detailed structural study of solvent accessibility in the case of the HET-s(218-295) prion protein. For the first approach, after incubation in the deuterated solvent, aggregated HET-s(218-295) was digested with pepsin and the generated peptides were analyzed by nanospray mass spectrometry in an ion trap, with and without collision-induced dissociation (CID). We compared deuterium incorporation in peptides as determined on peptide pseudomolecular ions and on b and y fragments produced by longer peptides under CID conditions. For both b and y fragment ions, an extensive H/D scrambling phenomenon was observed, in contrast with previous studies comparing CID-MS experiments and (1)H NMR data. Thus, the spatial resolution of HXMS experiments could not be improved by means of MS/MS data generated by an ion trap mass spectrometer. In a second approach, the incorporation of deuterium was analyzed by MS for 76 peptides of the HET-s(218-289) peptide mass fingerprint, and the use of shared boundaries among peptic peptides allowed us to determine deuteration levels of small regions ranging from one to four amino acids. This methodology led to evidence of highly protected regions along the HET-s(218-295) sequence.  相似文献   

13.
质谱技术在蛋白质、多肽化学中的应用   总被引:1,自引:0,他引:1  
李一莉  金善炜 《有机化学》1996,16(3):209-217
文中介绍了几种新的质谱技术: 快原子轰击质谱(fast atom bombardment-MS, 简称FAB-MS)、串联质谱(tandem mass spectrometry, 简称MS/MS)、电喷雾电离质谱(electrospray ionization-MS, 简称ESI-MS)和基质辅助的激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time offlight MS, 简称MALDI-TOF-MS), 这几种技术的相互补充使得质谱比较有效地用于蛋白质结构测定。文中例举了几个实例说明了它们在蛋白质的分子量测定,蛋白质和多肽的纯度鉴定, 糖肽的结构测定及特殊的N-端封闭的或一般的蛋白质和多肽的顺序测定中的应用。  相似文献   

14.
The structural characterization of a new oligosaccharide antibiotic, Everninomicin-6 (EV-6), is described. Detailed fast-atom bombardment mass spectrometry (FAB-MS) studies along with NMR and chemical degradation methods were conducted to elucidate the structure of EV-6. The effects of the use of various matrices, including salt addition, on the quality of the FAB-MS were explored. The use of 3-nitro benzyl alcohol, dimethyl sulfoxide (DMSO), and NaCl produced the best results: an intense sodiated molecular ion plus structurely informative fragmentation. FAB-MS yields information providing the complete sugar sequence information for everninomicins, which is quite valuable to the elucidation of the structure of this complex oligosaccharide antibiotic. In addition, the results of accurate mass work with the molecular ion are consistent with the assigned structure. The use of electrospray ionization mass spectrometry (ESI-MS) and ESI-MS/MS for the study of EV-6 was investigated and was found to produce an abundant molecular ion with limited structural information. These results revealed that EV-6 resembled EV-D quite closely except for the absence of the nitrosugar and the replacement on ring g of the -CH2OCH3 group with a -CH2OH group.  相似文献   

15.
Previous studies of the fractionated venom of the Brazilian armed spider Phoneutria nigriventer, obtained by gel filtration, have demonstrated the presence of a fraction PhM, a pool of small peptides (up to 2000 Da) that provoke contractions in smooth muscle of guinea pig ileum. Initial attempts to sequence these peptides were largely unsuccessful because of the low purification yield and the fact that the majority seemed to be blocked at their N-termini. In the present work, analysis of this venom fraction by mass spectrometry has revealed the existence of a highly complex mixture of peptides with molecular weights corresponding to those observed for the muscle-active peptides previously described (800-1800 Da). These peptides appear to be a family of isoforms with some particular features. The amino acid sequences of 15 isoforms have been determined by tandem mass spectrometry (MS/MS) using both electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-Q/ToFMS) and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-ToF/ToFMS). These molecules contain post-translational modifications such as proteolysis and C-terminal amidation, which combine to generate additional isoforms. All the isoforms sequenced in this study possess an N-terminal pyroglutamic acid residue. A search for sequence similarities with other peptides in databanks revealed that these peptides are structurally related to the tachykinins, a family of neuro-hormone peptides. The data obtained in this study will be essential for the subsequent steps of this research, the synthesis of these peptides and pharmacological characterization of their biological activity.  相似文献   

16.
Electrospray ionization linked to quadrupole/orthogonal-acceleration time-of-flight (Q/oaTOF) and ion trap equipment was used to study the fragmentation behavior of the linear side-chain cyclized peptides of the polymyxin B and E antibiotics. This study exemplifies both the benefits and the drawbacks of mass spectrometric techniques for the determination of the sequence of such complex linear side-chain cyclized peptides. Q/oaTOF accurate mass measurements did not help sufficiently to assign the product ions observed in the product ion spectra. An ion trap mass spectrometer providing MS(n) capability was used to eliminate ambiguities encountered with a single MS/MS approach. The complex fragmentation behavior of these compounds of well-established structure is described which could be useful for structural characterization of unknown substances related to polymyxin B and E in the future.  相似文献   

17.
Electrospray ionization ion trap mass spectrometry (ESI-ITMS) coupled to a two-dimensional liquid chromatographic separation was applied to the identification of peptides in antimicrobial fractions of the aqueous extracts of nine Italian cheese varieties. In particular, the chromatographic fractions collected during a preliminary fast protein liquid chromatography (FPLC) separation on the cheese extracts were assayed for antimicrobial activity towards Lactobacillus sakei A15. Active fractions were subsequently analyzed by reversed-phase high-performance liquid chromatography electrospray ionization sequential mass spectrometry (HPLC/ESI)-ITMSn, with n up to 3. Peptide identification was then performed starting from a conventional proteomics approach based on tandem mass spectrometric (MS/MS) analysis followed by database searching. In many cases this strategy had to be integrated by a careful correlation between spectral information and predicted peptide fragmentation, in order to reach unambiguous identifications. When even this integrated approach failed, MS3 measurements provided decisive information on the amino acid sequence of some peptides, through fragmentation of pendant groups along the peptide chain. As a result, 45 peptides, all arising from hydrolysis of milk caseins, were identified in nine antimicrobial FPLC fractions of aqueous extracts obtained from five of the nine cheese varieties considered. Many of them corresponded to peptides already known to exhibit biological activity.  相似文献   

18.
Bioactive peptides and tryptic digests of various proteins were separated under acidic and alkaline conditions by ion-pair-reversed-phase high-performance liquid chromatography (RP-HPIPC) in 200 microm I.D. monolithic, poly(styrene-divinylbenzene)-based capillary columns using gradients of acetonitrile in 0.050% aqueous trifluoroacetic acid, pH 2.1, or 1.0% triethylamine-acetic acid, pH 10.6. Chromatographic performances with mobile phases of low and high-pH were practically equivalent and facilitated the separation of more than 50 tryptic peptides of bovine serum albumin within 15-20 min with peak widths at half height between 4 and 10 s. Neither a significant change in retentivity nor efficiency of the monolithic column was observed during 17-day operation at pH 10.6 and 50 degrees C. Upon separation by RP-HPIPC at high-pH, peptide detectabilities in full-scan negative-ion electrospray ionization mass spectrometry (negESI-MS) were about two to three times lower as compared to RP-HPIPC at low-pH with posESI-MS detection. Tandem mass spectra obtained by fragmentation of deprotonated peptide ions in negative ion mode yielded interpretable sequence information only in a few cases of relatively short peptides. However, in order to obtain sequence information for peptides separated with alkaline mobile phases, tandem mass spectrometry (MS/MS) could be performed in positive ion mode. The chromatographic selectivities were significantly different in separations performed with acidic and alkaline eluents, which facilitated the fractionation of a complex peptide mixture obtained by the tryptic digestion of 10 proteins utilizing off-line, two-dimensional RP-HPIPC at high pH x RP-HPIPC at low pH and subsequent on-line identification by posESI-MS/MS.  相似文献   

19.
A photoaffinity labeling (PAL)‐based method for the rapid identification of target proteins is presented in which a high‐performance chemical tag, an isotope‐coded fluorescent tag (IsoFT), can be attached to the interacting site by irradiation. Labeled peptides can be easily distinguished among numerous proteolytic digests by sequential detection with highly sensitive fluorescence spectroscopy and mass spectrometry. Subsequent MS/MS analysis provides amino acid sequence information with a higher depth of coverage. The combination of PAL and heterogeneous target‐selecting techniques significantly reduces the amount of time and protein required for identification. An additional photocleavable moiety successfully accelerated proteomic analysis using cell lysate. This method is a widely applicable approach for the rapid and accurate identification of interacting proteins.  相似文献   

20.
《Analytical letters》2012,45(17-18):1793-1807
Abstract

Separation by reversed-phase high performance liquid chromatography (RP-HPLC) of peptide mixtures obtained from tryptic digestion of abnormal human hemoglobins and subsequent analysis by fast atom bombardment mass spectrometry (FAB-MS) of selected peptides allow unambiguous, rapid identification of the hemoglobin variants. By this method two varied hemoglobins, Hb D Punjab and Hb J Sardegna, have been determined. The methodology described, which is simple and reliable, could be used for the detection and structural identification of known and unknown Hb variants, without amino acid (a.a.) or sequence analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号