首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The co-flow laminar spray diffusion flame in an oscillating flow field is investigated. Mild slip is permitted between the droplets and their host surroundings and droplet grouping resulting from the host flow oscillations is accounted for. The spray is modelled using the sectional approach and a perturbation analysis using a small sectional Stokes number is utilised for solving the liquid phase governing equations. The effect of droplet grouping is described through a specially constructed model for the vaporisation Damkohler number. The large chemical Damkohler number assumption is adopted and a formal analytical solution is developed for Schwab-Zeldovitch parameters through which the dynamics of the spray flame front shapes and thermal fields are deduced. Computed results based on the solutions demonstrate how the phenomenon of droplet grouping can lead to the existence of multiple flame sheets as a result of the dynamic change in the type of the main homogeneous flame from under- to over-ventilated as the flow field oscillates. Concomitant fluctuating thermal fields are also shown to be present indicating a potential impact on undesirable pollutants production.  相似文献   

2.
A new mathematical analysis of a laminar Burke-Schumann type of spray diffusion flame in an oscillating flow field is presented within a framework in which mild slip is permitted between the droplets and their host surroundings. A perturbation analysis using a small Stokes number is used for solving the liquid phase governing equations. The effect of droplet grouping in the oscillatory flow field is accounted for by constructing an appropriate model for the vaporization Damkohler number. A formal analytical solution is developed for the Schwab-Zeldovitch parameter through which instantaneous flame front shapes are found. Computed results based on the solution expose the strong impact that the phenomenon of droplet grouping can have on flame characteristics such as flame height, shape and type (over- or under-ventilated). Despite the models simplicity its predictions offer an opening insight into the mechanisms prevalent in more complex spray-combustion situations in which droplet grouping may occur.  相似文献   

3.
A theory of stagnation-point flow polydisperse spray flame ignition by an isothermal hot surface is presented for the first time. The configuration investigated consists of a mixture of fuel droplets and air flowing against an isothermal hot surface (such as a hot ignition probe). The polydisperse spray of droplets is modelled using the sectional approach. A single global chemical reaction is assumed for the case when ignition occurs. The mathematical analysis makes use of a small parameter that is exploited for an asymptotic approach. An analytical criterion for ignition is derived which includes effects of the flow field, the reactants and all the fuel spray-related parameters, including the initial size distribution of the spray's droplets. Numerical calculations disclose how the actual droplet size distribution impacts on the critical stagnation point temperature necessary to promote ignition. Additionally, the analytical estimates are compared with predictions of a numerical finite difference code with very satisfactory agreement.  相似文献   

4.
Water, sprayed in the form of tiny droplets, has emerged as a potential fire suppressant after the halon compounds such as trifluorobromomethane (CF3Br, Halon 1301) were banned by the Montreal protocol. The size distribution of the water droplet plays a crucial role in the effectiveness of the water spray in fire suppression. A numerical investigation of the influence of size distribution of a polydisperse water spray on extinction of counterflow diffusion flames is presented in this paper. This study uses laminar finite rate model with reduced CHEMKIN chemistry for numerical simulations. The discrete phase, namely the water spray, is simulated using Lagrangian Discrete Phase Modelling approach. In this work, the polydispersity of water spray is taken into account in the numerical simulation by a suitable Rosin–Rammler distribution. Results obtained from numerical simulation are validated with the experimental results reported in the literature. This study demonstrates that the representation of the polydisperse spray by a monodisperse spray (with droplet diameter same as the SMD of the polydisperse spray) in numerical simulations is not always justified and it leads to deviation from the experimental results. The effects of number mean diameter and spread parameter on the efficacy of flame suppression are investigated for polydisperse sprays. A comprehensive comparison is done between the effectiveness of monodisperse and polydisperse water sprays. An optimum droplet diameter is obtained for monodisperse sprays for which the effectiveness of the spray is maximum. The effects of evaporation Damköhler number and Stokes number of water droplets on flame suppression have also been explained.  相似文献   

5.
The recently reported, experimentally observed, unusual behaviour of organic gellant-based fuel droplets which, under appropriate ambient thermal conditions, evaporate and burn in an oscillatory fashion is incorporated in a phenomenological manner in a model of a two-dimensional arbitrary multi-size spray diffusion flame. Non-unity Lewis numbers are permitted for the fuel vapour and oxidant. A combined analytical/numerical solution of the governing equations is presented and used to investigate how a spray's initial polydispersity and the frequency of oscillatory evaporation influence the combustion field. It is demonstrated that the initial droplet size distribution and the frequency of evaporation of the burning gel droplets can have an acute impact both on the homogeneous diffusion flame shape, height and width and on the thermal field downstream of the flame front. Hot spots of individual (or clusters of) burning droplets can be created and under certain operating conditions can lead to hotter temperatures than experienced in the main homogeneous flame. The intensity of these hotspots, their number and location are sensitive to spray related parameters. In realistic combustion chambers there is a danger inherent in the existence of hotspots in undesirable regions as they can damage the structural integrity. Other computed results demonstrate that, in relation to the spray diffusion flames obtained using an equivalent purely liquid fuel spray, the use of a gel fuel spray can lead, under certain operating conditions, to a reduction in flame height and temperature. The latter effect is critical when considering flame extinction.  相似文献   

6.
Auto-ignition of a polydisperse fuel spray   总被引:1,自引:0,他引:1  
In the present paper, the effect of fuel spray polydispersity on the auto-ignition process in a fuel cloud is considered. In many engineering applications it is common practice to relate to the actual polydisperse spray as being equivalent to a monodisperse spray with all droplets therein having some average diameter. In combustion systems, the Sauter mean diameter (SMD) is frequently used for this purpose; it is based on the ratio between the total droplet volume and the total droplet surface area of all the droplets in the polydisperse spray. The main purpose of the current work is to examine qualitatively the dynamics of ignition of a truly polydisperse spray in a combustible gas medium and compare it with the dynamics of an equivalent monodisperse spray based on the SMD. Since the system of governing equations represents a multi-scale problem the method of integral manifolds is applied in order to extract the dynamical behavior. Preliminary computed results suggest that the use of the usual SMD-based monodisperse spray leads to quite a significant over-estimate of the ignition time. An alternative modified definition of the SMD, in which the overall liquid fuel volume is also conserved in the averaging process, reduces the discrepancy between the ignition time for the polydisperse spray and that of the equivalent monodisperse spray. However, it seems that some other sort of average droplet size needs to be determined to minimize the aforementioned discrepancy. These results highlight the care that must be exercised before dispensing with the behavior of the actual polydisperse spray in favor of that of an equivalent monodisperse spray, even at the expense of complexity.  相似文献   

7.
A new mathematical analysis is presented of certain aspects of the behavior of opposed flow polydisperse spray diffusion flames within the framework of a model in which large slip is permitted between the droplets and their host surroundings. The sectional approach is used to model the polydisperse spray. Operating conditions are identified under which the inverses of sectional Stokes numbers are small spray-related parameters to be used in a perturbation analysis of the liquid phase governing equations. The steady state equations and their solutions are similar in form to the equivalent equations considered in previous work of the authors in which dynamical equilibrium of the droplets with the carrier phase was assumed. However, here there is much more mathematical complexity involved in the spray equations solution. A hybrid Eulerian–Lagrangian approach is also suggested to get an insight into the phenomenon of reversal in the motion of the droplets that has been reported in independent experimental and computational research. Computed results based on the analytical solutions up to the 1st order of approximation reveal the influence of large droplet slip on the droplets velocity field and on the spray diffusion flame’s thermal field, for which appreciable heterogeneous combustion can occur under the operating conditions considered.  相似文献   

8.
Gas turbines, liquid rocket motors, and oil-fired furnaces utilize the spray combustion of continuously injected liquid fuels. In most cases, the liquid spray is mixed with an oxidizer prior to combustion, and further oxidizer is supplied from the outside of the spray to complete diffusion combustion. This rich premixed spray is called “partially premixed spray.” Partially premixed sprays have not been studied systematically although they are of practical importance. In the present study, the burning behavior of partially premixed sprays was experimentally studied with a newly developed spray burner. A fuel spray and an oxidizer, diluted with nitrogen, was injected into the air. The overall equivalence ratio of the spray jet was set larger than unity to establish partially premixed spray combustion. In the present burner, the mean droplet diameter of the atomized liquid fuel could be varied without varying the overall equivalence ratio of the spray jet. Two combustion modes with and without an internal flame were observed. As the mean droplet diameter was increased or the overall equivalence ratio of the spray jet was decreased, the transition from spray combustion only with an external group flame to that with the internal premixed flame occurred. The results suggest that the internal flame was supported by flammable mixture through the vaporization of fine droplets, and the passage of droplet clusters deformed the internal flame and caused internal flame oscillation. The existence of the internal premixed flame enhanced the vaporization of droplets in the post-premixed-flame zone within the external diffusion flame.  相似文献   

9.
The quasi-steady vaporization and combustion of multiple-droplet arrays is studied numerically. Utilizing the Shvab–Zeldovich formulation, a transformation of the governing equations to a three-dimensional Laplace’s equation is performed, and the solution to Laplace’s equation is obtained numerically to find the effects of droplet interactions in symmetric, multiple-droplet arrays. Vaporization rates, flame surface shapes, and flame locations are found for different droplet array configurations and fuels. The number of droplets, the droplet arrangement within the arrays, and the droplet spacing within the arrays are varied to determine the effects of these parameters. Computations are performed for uniformly spaced three-dimensional arrays of up to 216 droplets, with center-to-center spacing ranging from 3 to 25 droplet radii. As a result of the droplet interactions, the number of droplets and relative droplet spacing significantly affect the vaporization rate of individual droplets within the array, and consequently the flame shape and location. For small droplet spacing, the individual droplet vaporization rate decreases below that obtained for an isolated droplet by several orders of magnitude. A similarity parameter which correlates vaporization rates with array size and spacing is identified. Individual droplet flames, internal group combustion, and external group combustion can be observed depending on the droplet geometry and boundary conditions.  相似文献   

10.
The paper presents Large Eddy Simulations (LESs) for the Sydney ethanol piloted turbulent dilute spray flames ETF2, ETF6, and ETF7. The Flamelet Generated Manifold (FGM) approach is employed to predict mixing and burning of the evaporating fuel droplets. A methodology to match the experimental inflow spray profiles is presented. The spray statistical time-averaged results show reasonable agreement with mean and RMS data. The Particle Size Distribution (PSD) shows a good match downstream of the nozzle exit and up to x/D = 10. At x/D = 20 and 30 the PSD is under-predicted for droplets with mean diameter D10 > 20μm and over-predicted for the smaller size droplets. The simulations reasonably predict the reported mean flame structure and length. The effect of increasing the carrier velocity (ETF2–ETF7) or decreasing the liquid fuel injection mass flow rate (ETF2–ETF6) is found to result in a leaner, shorter flame and stronger spray–flow interactions. Higher tendency to local extinction is observed for ETF7 which is closer to blow-off compared to ETF2 and has higher scalar dissipation rates, higher range of Stokes number, and faster droplet response. The possible sources of LES-FGM deviations from the measurements are discussed and highlighted. In particular, the spray time-averaged statistical error contribution is quantified and the impact of the inflow uncertainty is studied. Sensitivity analysis to the pre-vaporized nozzle fuel mass fraction show that such small inflow perturbations (by ±?2% for the ETF2 flame) have a strong impact on the flame structure, and the droplets’ dynamics. Conditional scatter plots show that the flame exhibits wide range of mixing conditions and bimodal mixing lines particularly at upstream locations (x/D?相似文献   

11.
A laminar jet polydisperse spray diffusion flame is analysed mathematically for the first time using an extension of classical similarity solutions for gaseous jet flames. The analysis enables a comparison to be drawn between conditions for flame stability or flame blow-out for purely gaseous flames and for spray flames. It is found that, in contrast to the Schmidt number criteria relevant to gas flames, droplet size and initial spray polydispersity play a critical role in determining potential flame scenarios. Some qualitative agreement for lift-off height is found when comparing predictions of the theory and sparse independent experimental evidence from the literature.  相似文献   

12.
An experimental study was performed on the combustion of lean-premixed spays in a counterflow. n-Decane was used as a liquid fuel with low volatility. The flame structure and stabilization were discussed based on the flame-spread mechanism of a droplet array with a low-volatility fuel. The spray flame consisted of a blue region and a yellow luminous region. The flame spread among droplets and group-flame formation through the droplet interaction were observed on the premixed spray side, while envelope flames were also observed on the opposing airflow side. The blue-flame region consisted of premixed flames propagating in the mixture layer around each droplet, the envelope diffusion flames around each droplet, the lower parts of the group diffusion flame surrounding each droplet cluster, and the envelope flame around droplets passing through the group flame. The flame was stabilized within a specific range of the mean droplet diameter via a balance between the droplet velocity and the flame-spread rate of the premixed spray.  相似文献   

13.
Experimental evidence seems to indicate that the life of a laminar spherical flame front propagating through a fresh mixture of air and liquid fuel droplets can be roughly split into three stages: (1) ignition, (2) radial propagation with a smooth flame front and (3) propagation with flame front cellularization and/or pulsation. In this work, the second stage is analysed using the slowly varying flame approach, for a fuel rich flame. The droplets are presumed to vaporize in a sharp front ahead of the reaction front. Evolution equations for the flame and evaporation fronts are derived. For the former the combined effect of heat loss due to droplet vaporization and radiation plays a dominant explicit role. In addition, the structure of the evaporation front is deduced using asymptotics based on a large parameter associated with spray vaporization. Numerical calculations based on the analysis point to the way in which the spray modifies conditions for flame front extinction. Within the framework of the present simplified model the main relevant parameters turn out to be the initial liquid fuel load in the fresh mixture and/or the latent heat of vaporization of the fuel.  相似文献   

14.
为考察溶液注入热等离子体喷涂过程中喷雾参数对涂层质量的影响,本文建立了溶液液滴在热等离子体中运动蒸发的数学模型。模拟了液滴在不同参数下的运动和蒸发的过程,考虑了液滴、热等离子气流及液滴表面气体混合物随温度及组分的物性变化以及斯蒂芬流的影响,得到液滴的运动轨迹,蒸发速率以及半径和表面温度的变化。结果表明在一定范围内增大液...  相似文献   

15.
A partially prevaporized spray burner was developed to investigate the interaction between fuel droplets and a flame. Monodispersed partially prevaporized ethanol sprays with narrow diameter distribution were generated by the condensation method using rapid pressure reduction of a saturated ethanol vapor–air mixture. A tilted flat flame was stabilized at the nozzle exit using a hot wire. Particle tracking velocimetry (PTV) was applied to measurements of the droplet velocity; the laminar burning velocity was obtained from gas velocity derived from the droplet velocity. Observations were made of flames in partially prevaporized spray streams with mean droplet diameters of 7 μm and the liquid equivalence ratios of 0.2; the total equivalence ratio was varied. In all cases, a sharp vaporization plane was observed in front of the blue flame. Flame oscillation was observed on the fuel-rich side. At strain rates under 50 s−1, the change in the burning velocity with the strain rate is small in fuel-lean spray streams. In spray streams of 0.7 and 0.8 in the total equivalence ratio, burning velocity increases with strain rates of greater than 50 s−1. However, in spray streams with 0.9 and 1.0 in the total equivalence ratio, burning velocity decreases as the strain rate increases. At strain rates greater than 80 s−1, burning velocity decreases with an increased gas equivalence ratio. The effect of mean droplet diameter, and the entry length of droplets into a flame on the laminar burning velocity, were also investigated to interpret the effect of the strain rate on the laminar burning velocity of partially prevaporized sprays.  相似文献   

16.
喷雾蒸发燃烧的研究对指导发动机燃烧系统设计具有重要意义。本文搭建了高速数字全息系统,在线测量乙醇喷雾火焰中液滴的粒径、三维位置、速度及蒸发率。对喷雾火焰中的液滴进行了统计分析,得到液滴粒径及三维空间分布。燃烧喷雾场液滴的平均粒径为68μm;非燃烧火焰测试区液滴数量多且较密集,燃烧火焰测试区液滴数量少且稀疏.追踪单液滴并处理得到湍流火焰中液滴的运动轨迹及速度。通过研究粒径的平方D2随停留时间ts的变化,测得液滴平均蒸发率为-3.343×10-7 m2/s.  相似文献   

17.

A simple model of a flame front propagating through a fuel-rich droplet–vapour–air mixture is presented in which the fuel droplets are assumed to evaporate in a sharp front ahead of the reaction front. By performing a linear stability analysis neutral stability boundaries are determined. It is shown that the presence of the spray of droplets in the fresh mixture can have a profound effect by causing cellularization of the flame front. Specifically, we demonstrate that under certain circumstances a spray flame can be cellular when its equivalent non-spray flame is completely stable. Furthermore, it is shown that even when the non-spray flame is itself cellular the equivalent spray flame will have a finer cellular structure. These theoretical predictions verify qualitatively for the first time independent experimental observations from the literature. It is thus shown that the primary effect of the spray on the stability of these flames is due to heat loss from the absorption of heat by the droplets for vaporization. The influence of the initial liquid fuel loading and the latent heat of vaporization on the critical wavenumber associated with cellularity provide further evidence of the responsibility of the heat loss mechanism for these spray-related phenomena. Finally, the cellularity of the spray flames with their attendant increase in flame front area suggest a plausible rationale for the experimentally observed burning velocity enhancement induced by the use of a spray of fuel droplets.  相似文献   

18.
A model is presented for a one-dimensional laminar premixed flame, propagating into a rich, off-stoichiometric, fresh homogenous mixture of water-in-fuel emulsion spray, air and inert gas. Due to its relatively large latent heat of vaporisation, the water vapour acts to cool the flame that is sustained by the prior release of fuel vapour. To simplify the inherent complexity that characterises the analytic solution of multi-phase combustion processes, the analysis is restricted to fuel-rich laminar premixed water-in-fuel flames, and assumes a single-step global chemical reaction mechanism. The main purpose is to investigate the steady-state burning velocity and burnt temperature as functions of parameters such as initial water content in the emulsified droplet and total liquid droplet loading. In particular, the influence of micro-explosion of the spray’s droplets on the flame’s characteristics is highlighted for the first time. Steady-state analytical solutions are obtained and the sensitivity of the flame temperature and the flame propagating velocity to the initial water content of the micro-exploding emulsion droplets is established. A linear stability analysis is also performed and reveals the manner in which the micro-explosions influence the neutral stability boundaries of both cellular and pulsating instabilities.  相似文献   

19.
喷雾湍流燃烧过程中,液滴、湍流和化学反应之间强烈耦合,物理化学机理非常复杂。本文将速度-标量-频率联合概率密度函数JPDF输运方程方法应用于两相喷雾湍流反应流问题,利用火焰面模型解耦流动和化学反应动力学的耦合关系,建立起相应的数值计算模型。采用Monte-Carlo数值计算方法,针对澳大利亚悉尼大学Masri等人以甲醇为燃料所进行的湍流喷雾燃烧值班火焰这一试验进行了数值模拟,通过与Fluent下的计算结果及试验结果的对比分析,验证了本文所建模型的准确性。  相似文献   

20.
The combination of the optical diagnostics and image processing technique has produced various methods of practical measurement in engineering. The measurement of size and velocity of droplets in fuel spray is one typical example. In general, the spray is a complicated and three-dimensional two-phase flow; therefore multi-dimensional field measurement of the spray field is indispensable. In the present paper, a technique of simultaneous measurement of droplet size and three-components of velocity is proposed and applied to spray issuing from the swirl nozzle as a practical application. The focused image of glare points is captured by a stereoscopic arrangement, and droplet size and the three-components of velocity are evaluated from the doublet image. Fundamental optical arrangements to capture the image of the glare points with a stereo view are established, and the feasibility and the accuracy of the technique are confirmed. © 2004 The Optical Society of Japan  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号