首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Magnetic nanoparticle (MNP) seeds were studied in vitro for use as an implant in implant assisted-magnetic drug targeting (IA-MDT). The magnetite seeds were captured in a porous polymer, mimicking capillary tissue, with an external magnetic field (70 mT) and then used subsequently to capture magnetic drug carrier particles (MDCPs) (0.87 μm diameter) with the same magnetic field. The effects of the MNP seed diameter (10, 50 and 100 nm), MNP seed concentration (0.25-2.0 mg/mL), and fluid velocity (0.03-0.15 cm/s) on the capture efficiency (CE) of both the MNP seeds and the MDCPs were studied. The CE of the 10 nm MNP seeds was never more than 30%, while those of the 50 and 100 nm MNP seeds was always greater than 80% and in many cases exceeded 90%. Only the MNP seed concentration affected its CE. The 10 nm MNP seeds did not increase the MDCP CE over that obtained in the absence of the MNP seeds, while the 50 and 100 nm MNP seeds increased significantly, typically by more than a factor of two. The 50 and 100 nm MNP seeds also exhibited similar abilities to capture the MDCPs, with the MDCP CE always increasing with decreasing fluid velocity and generally increasing with increasing MNP seed concentration. The MNP seed size, magnetic properties, and capacity to self-agglomerate and form clusters were key properties that make them a viable implant in IA-MDT.  相似文献   

2.
The concept of using magnetic particles (seeds) as the implant for implant assisted-magnetic drug targeting (IA-MDT) was analyzed in vitro. Since this MDT system is being explored for use in capillaries, a highly porous (ε∼70%), highly tortuous, cylindrical, polyethylene polymer was prepared to mimic capillary tissue, and the seeds (magnetite nanoparticles) were already fixed within. The well-dispersed seeds were used to enhance the capture of 0.87 μm diameter magnetic drug carrier particles (MDCPs) (polydivinylbenzene embedded with 24.8 wt% magnetite) under flow conditions typically found in capillary networks. The effects of the fluid velocity (0.015–0.15 cm/s), magnetic field strength (0.0–250 mT), porous polymer magnetite content (0–7 wt%) and MDCP concentration (C=5 and 50 mg/L) on the capture efficiency (CE) of the MDCPs were studied. In all cases, when the magnetic field was applied, compared to when it was not, large increases in CE resulted; the CE increased even further when the magnetite seeds were present. The CE increased with increases in the magnetic field strength, porous polymer magnetite content and MDCP concentration. It decreased only with increases in the fluid velocity. Large magnetic field strengths were not necessary to induce MDCP capture by the seeds. A few hundred mT was sufficient. Overall, this first in vitro study of the magnetic seeding concept for IA-MDT was very encouraging, because it proved that magnetic particle seeds could serve as an effective implant for MDT systems, especially under conditions found in capillaries.  相似文献   

3.
Implant-assisted-magnetic drug targeting (IA-MDT) was studied in vitro using a coiled ferromagnetic wire stent made from stainless steel 430 or 304, and magnetic drug carrier particle (MDCP) surrogates composed of poly(styrene/divinylbenzene) embedded with 20 wt% magnetite. The fluid velocity, particle concentration, magnetic field strength, and stent material all proved to be important for capturing the MDCP surrogates. Overall, this in vitro study further confirmed the important role of the ferromagnetic implant for attracting and retaining MDCPs at the target zone.  相似文献   

4.
Implant assisted-magnetic drug targeting (IA-MDT) was studied both in vitro and theoretically, with extensive comparisons made between model and experiment. Magnetic drug carrier particles (MDCPs) comprised of magnetite encased in a polymer were collected magnetically using a ferromagnetic, coiled, wire stent as the implant and a NdFeB permanent magnet for the applied magnetic field. A 2-D mathematical model with no adjustable parameters was developed and compared to the 3-D experimental results. The effects of the fluid velocity, stent and MDCP properties, and magnetic field strength on the performance of the system were evaluated in terms of the capture efficiency (CE) of the MDCPs. In nearly all cases, the parametric trends predicted by the model were in good agreement with the experimental results: the CE always increased with decreasing velocity, increasing magnetic field strength, increasing MDCP size or magnetite content, or increasing wire size. The only exception was when experiments showed an increase in the CE with an increase in the number of loops in the wire, while the model showed no dependence. The discrepancies between experiment and theory were attributed to phenomena not accounted for by the model, such as 3-D to 2-D geometric and magnetic field orientation differences, and interparticle interactions between the MDCPs that lead to magnetic agglomeration and shearing force effects. Overall, this work showed the effectiveness of a stent-based IA-MDT system through both in vitro experimentation and corroborated theory, with the designs of the ferromagnetic wire and the MDCPs both being paramount to the CE.  相似文献   

5.
Aqueous colloidal suspension of iron oxide nanoparticles has been synthesized. Z-potential of iron oxide nanoparticles stabilized by citric acid was −35±3 mV. Iron oxide nanoparticles have been characterized by the light scattering method and transmission electron microscopy. The polyelectrolyte/iron oxide nanoparticle thin films with different numbers of iron oxide nanoparticle layers have been prepared on the surface of silicon substrates via the layer-by-layer assembly technique. The physical properties and chemical composition of nanocomposite thin films have been studied by atomic force microscopy, magnetic force microscopy, magnetization measurements, Raman spectroscopy. Using the analysis of experimental data it was established, that the magnetic properties of nanocomposite films depended on the number of iron oxide nanoparticle layers, the size of iron oxide nanoparticle aggregates, the distance between aggregates, and the chemical composition of iron oxide nanoparticles embedded into the nanocomposite films. The magnetic permeability of nanocomposite coatings has been calculated. The magnetic permeability values depend on the number of iron oxide nanoparticle layers in nanocomposite film.  相似文献   

6.
A hypothetical magnetic drug targeting system, utilizing high gradient magnetic separation (HGMS) principles, was studied theoretically using FEMLAB simulations. This new approach uses a ferromagnetic wire placed at a bifurcation point inside a blood vessel and an externally applied magnetic field, to magnetically guide magnetic drug carrier particles (MDCP) through the circulatory system and then to magnetically retain them at a target site. Wire collection (CE) and diversion (DE) efficiencies were defined and used to evaluate the system performance. CE and DE both increase as the strength of the applied magnetic field (0.3–2.0 T), the amount of ferromagnetic material (iron) in the MDCP (20–100%) and the size of the MDCP (1–10 μm radius) increase, and as the average inlet velocity (0.1–0.8 m s−1), the size of the wire (50–250 μm radius) and the ratio (4–10) of the parent vessel radius (0.25–1.25 mm radius) to wire radius decrease. The effect of the applied magnetic field direction (0° and 90°) on CE and DE was minimal. Under these plausible conditions, CEs as high as 70% were obtained, with DEs reaching only 30%; however, when the MDCPs were allowed to agglomerate (4–10 μm radius), CEs and DEs of 100% were indeed achieved. These results reveal that this new magnetic drug targeting approach for magnetically collecting MDCPs at a target site, even in arteries with very high velocities, is feasible and very promising; this new approach for magnetically guiding MDCPs through the circulatory system is also feasible but more limited. Overall, this study shows that magnetic drug targeting, based on HGMS principles, has considerable promise as an effective drug targeting tool with many potential applications.  相似文献   

7.
A 2-D mathematical model was developed and used to examine the capture of magnetic drug carrier particles (MDCPs) by a magnetizable intravascular stent (MIS). The roles of both non-stent system parameters, i.e., the blood flow rate, magnetic field strength and direction and MDCP properties, and stent design parameters, i.e., the MIS radius, its wire radius, number of MIS loops, interwire loop spacing and MIS ferromagnetic material were evaluated over a wide range of plausible conditions. The results showed that the MIS could be a very effective magnetic drug targeting tool with many possible applications.  相似文献   

8.
Self-forming core/shell nanoparticles of magnetic metal/oxide with crystalline grain size of less than 40 nm were synthesized. The nanoparticles were highly concentrated in an insulating matrix to fabricate a nanocomposite, whose magnetic properties were investigated. The crystalline grain size of the nanoparticles strongly influenced the magnetic anisotropy field, magnetic coercivity, relative permeability, and loss factor (tan δ=μ″/μ′) at high frequency. The packing ratio of the magnetic metallic phase in the nanocomposite also influenced those properties. High permeability with low tan δ of less than 1.5% at up to 1 GHz was obtained in the case of the nanoparticles with crystalline grain size of around 15 nm with large packing ratio of the nanoparticles.  相似文献   

9.
The paper presents the results of theoretical and experimental researches of the analysis of nanopowder ZnO and ZnO-based structures formation mechanisms by means of pulse laser reactive technology (λ = 1.06 μm, τ = 10−7 to 10−5 s). The developed 2D model combines non-stationary heat transfer and fluid motion along with the calculated profile of surface deformation. The characteristics of the dispersive and chemical compositions and structural parameters of the synthesized nanopowder together with the influence of the energy of laser impulse evaporation, its duration and gas pressure in the reaction chamber have been studied using X-ray diffractrometry (XRD), energy-dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM). Particle size distribution analysis of ZnO has shown that the majority of them range from 5 to 60 nm in size. The photoluminescence emission spectra of the initial ZnO nanopowder at room temperature have been identified.  相似文献   

10.
Low density and thin thickness are essential for electromagnetic (EM) wave absorbers. In this study, we fabricated a novel micro-tubular iron nanocomposite (MTIC) that composed of carbon microtubes and monodisperse iron nanoparticles (NPs). The bulk density of MTIC is only 0.35±0.04 g cm−3 due to its micro-tubular structure. The presence of iron NPs increased the magnetic loss significantly and therefore enhanced the reflection loss (RL) of MTIC/paraffin composite. The optimum thickness for the composite is 1.5-1.8 mm, with maximum bandwidth of 7.6 GHz for RL<−5 dB and 3.6 GHz for RL<−10 dB. The corresponding frequency at this thickness is 10-18 GHz. Because of low density and broad bandwidth at thin thickness, MTIC is a promising light-weight absorber for EM wave absorption or microwave shielding. This study will also provide new ideas for fabricating microwave absorbers with low density and thin thickness.  相似文献   

11.
A novel method for fabricating magnetic iron oxide nanoparticles was achieved by using transparent vermicelli template as a new stabilizing material. The morphology of the as-prepared magnetic iron oxide deposited on the surface of vermicelli was observed as nanoclusters. The magnetization of the magnetic iron oxide nanoparticles at room temperature was decreased after carbonization at 200 °C. Therefore the thermal decomposition of iron oxide nanoparticles stabilized by starch vermicelli template yielded iron oxide/carbon nanocomposites with the soft magnetic behavior which are useful for biomedical applications.  相似文献   

12.
The microwave absorption properties of zinc oxide/carbonyl iron composite nanoparticles fabricated by high energy ball milling were studied at 0-20 GHz. Experiments showed that ZnO as a kind of dielectric material coating carbonyl iron particles made the bandwidth of reflection loss (RL)<−5 dB expanding to the low frequency, and enhanced absorption effect obviously. For a 3 mm thickness absorber of ZnO/carbonyl iron after 30 h milling, the values of RL<−5 dB and RL<−8 dB were obtained in the frequency range from 7.0 GHz to 17.8 GHz and from 9.8 dB to 14.9 dB, respectively, and its strongest RL peak was −29.34 dB at 13.59 GHz. The magnetic loss of carbonyl iron particles and the dielectric loss of ZnO particles were the main mechanisms of microwave absorption for the composites.  相似文献   

13.
Rhenium sulfide nanoparticles are associated with magnetic iron oxide through coprecipitation of iron salts with tetramethylammonium hydroxide. Sizes of the formed magnetic rhenium sulfide composite particles are in the range 5.5-12.5 nm. X-ray diffraction and energy-dispersive analysis of X-rays spectra demonstrate the coexistence of Fe3O4 and ReS2 in the composite particle, which confirm the formation of the magnetic rhenium sulfide composite nanoparticles. The association of rhenium sulfide with iron oxide not only keeps electronic state and composition of the rhenium sulfide nanoparticles, but also introduces magnetism with the level of 24.1 emu g-1 at 14 kOe. Surface modification with monocarboxyl-terminated poly(ethylene glycol) (MPEG-COOH) has the role of deaggregating the composite nanoparticles to be with average hydrodynamic size of 27.3 nm and improving the dispersion and the stability of the composite nanoparticles in water.  相似文献   

14.
We report on the frequency and field dependent complex magnetic susceptibility measurements of a kerosene-based magnetic fluid with iron oxide nanoparticles, stabilized with oleic acid, in the frequency range 0.1-6 GHz and over the polarising field range of 0-168.4 kA/m.By increasing polarising field, H, a subsidiary loss-peak clearly occurs in the vicinity of the ferromagnetic resonance peak, from which it remains distinct even in strong polarising fields of 168.4 kA/m. This is in contrast to other reported cases in which the intra-well relaxation process is manifested only as a shoulder of the resonance peak, which vanishes in polarising fields larger than that of 100 kA/m.The results of the XRD analysis connected to the anisotropy field results confirm that the investigated sample contains particles of magnetite and of the tetragonal phase of maghemite.Taking into account the characteristics of our sample, the theoretical analysis revealed that the intra-well relaxation process of the small particles of the tetragonal phase of maghemite may be responsible for the subsidiary loss peak of the investigated magnetic fluid.  相似文献   

15.
We are reporting the core-shell structured iron/graphite nanoparticles formed during annealing of a nanopowder prepared by laser pyrolysis of gas phase reactants. The originally synthesized Fe-C-N nanocomposite powder has been characterized by TEM, XRD and magnetic measurements. Nanopowder was heated up to 800 °C at ~ 1 Pa vacuum. Presence of iron nanoparticles with mean diameter 40 nm in the annealed state of nanopowder was proved by XRD and TEM analyses. Mössbauer spectroscopy was used for characterization of synthesized/annealed nanopowder to confirm the qualitative change in phase composition.  相似文献   

16.
Properties of FeCo nanocrystalline intermetallic powders prepared by salt-matrix hydrogen reduction of a milled Fe2O3-Co3O4 mixture were investigated. The product of 72 ks ball-milling at 350 rpm was CoFe2O4 nanopowder. Reduction of this powder for 3.6 ks by hydrogen at 750 °C resulted in the formation of Fe0.67Co0.33 stoichiometric compound. Scanning electron microscopy, electron dispersive spectrometry, X-ray diffraction and vibrating sample magnetometry were used to characterize the nanopowder. Using a salt-matrix (NaCl as a dispersion medium) resulted in the decrease of the reduction temperature and improvement of the morphology and magnetic properties of the nanopowder. Dispersion of the ball-milled product in Hexan resulted in further improvements of the magnetic properties.  相似文献   

17.
We present the results of the interaction of iron oxide nanoparticles with some biologically active surfactants, namely, oleic acid and cytotoxic alkanolamine derivatives. Physico-chemical properties, as magnetization, magnetite concentration and particle diameter, of the prepared magnetic samples were studied. The nanoparticle size of 11 nm for toluene magnetic fluid determined by TEM is in good agreement with the data obtained by the method of magnetogranulometry. In vitro cytotoxic effect of water-soluble nanoparticles with different iron oxide:oleic acid molar ratio were revealed against human fibrosarcoma and mouse hepatoma cells. In vivo results using a sarcoma mouse model showed observable antitumor action.  相似文献   

18.
Magnetic labeling of living cells creates opportunities for numerous biomedical applications. Here we describe an instantly cell magnetic labeling method based on ultrasound. We present a detailed study on the ultrasound performance of a simple and efficient labeling protocol for H-22 cells in vitro. High frequency focus ultrasound was investigated as an alternative method to achieve instant cell labeling with the magnetic particles without the need for adjunct agents or initiating cell cultures. Mean diameter of 168 nm dextran-T40 coated superparamagnetic iron oxide (SPIO) nanoparticles were prepared by means of classical coprecipitation in solution in our laboratory. H-22 tumor cells suspended in phosphate-buffered saline (PBS, pH=7.2) were exposed to ultrasound at 1.37 MHz for up to 120 s in the presence of SPIOs. The cellular uptake of iron oxide nanoparticles was detected by prussion blue staining. The viability of cells was determined by a trypan blue exclusion test. At 2 W power and 60 s ultrasound exposure in presence of 410 μg/ml SPIOs, H-22 cell labeling efficiency reached 69.4±6.3% and the labeled cells exhibited an iron content of 10.38±2.43 pg per cell. Furthermore, 95.2±3.2% cells remained viable. The results indicated that the ultrasound protocol could be potentially applied to label cells with large-sized magnetic particles. We also calculated the shear stress at the 2 W power and 1.37 MHz used in experiments. The results showed that the shear stress threshold for ultrasonically induced H-22 cell reparable sonoporation was 697 Pa. These findings provide a quantitative guidance in designing ultrasound protocols for cell labeling.  相似文献   

19.
Magnetic properties of glass ceramics derived from glasses with composition 41CaO·(52−x)SiO2·4P2O5·xFe2O3·3Na2O (2?x?10 mol% iron oxide (Fe2O3)) are reported. Structural investigation revealed the presence of nanocrystalline magnetite phase in the heat-treated samples containing x?2 mol% Fe2O3. Magnetic hysteresis cycles of the glass-ceramic samples were obtained with a maximum applied field of ±20 kOe as well as a low field of ±500 Oe, in order to evaluate the potential of these glass ceramics for hyperthermia treatment of cancer. Samples with x>2 mol% of iron oxide exhibited magnetic behavior similar to soft magnetic materials with low coercivity. The evolution of magnetic properties in these samples as a function of iron oxide molar concentration is correlated with the amount and crystallite size of magnetite phase present in them.  相似文献   

20.
We describe an one-step 11-min magnetic permeability based two-site immunoassay for C-reactive protein (CRP) utilizing polyclonal anti-canine CRP antibody conjugated dextran iron oxide nanoparticles (79 nm) as superparamagnetic labels and polyclonal anti-canine CRP conjugated silica microparticles (15 to 40 μm) as carriers. An inductance based magnetic permeability reader was used to detect the target analyte, CRP, in 10 μL whole blood samples, by measuring the magnetic permeability increase of the silica microparticle sediment due to immuno complex superparamagnetic nanoparticles. Measurements on standards showed a linear response between 0 and 17.5 mg/L CRP. Measurements performed on 16 whole blood samples from mixed breeds showed good correlation with a commercially available ELISA assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号