首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mohamed AM 《Talanta》1988,35(8):621-624
A new spectrophotometric method for the determination of some benzothiadiazine drugs is presented, based on reaction with 7,7,8,8-tetracyanoquinodimethane in sodium acetate medium and measurement at 578 nm. Beer's law is obeyed in the concentration range 0.7-6.0 mug/ml for all eight drugs tested.  相似文献   

2.
3.
4.
Gowda HS  Jagadeesh KS 《Talanta》1978,25(7):416-417
Trifluoperazine dihydrochloride reacts with platinum(IV) in sodium acetate-hydrochloric acid buffer containing copper(II) catalyst to form a bluish-green 1:1 complex with absorbance maximum at 504 nm. A 50-fold ratio of reagent to metal ion is necessary for complete complexation. Beer's law is valid over the concentration range 0.5-8 ppm of platinum(IV) with optimum concentration range 1-7 ppm. The molar absorptivity is 6.50 x 10(3) l.mole(-1).cm(-1). The effects of pH, time, temperature, concentration of reagent and copper, order of addition of reagents, and the interferences from various ions are reported.  相似文献   

5.
6.
7.
Lu M  Tong P  Xiao H  Xia S  Zheng X  Liu W  Zhang L  Chen G 《Electrophoresis》2007,28(9):1461-1471
A rapid, high-resolution and effective new method for analyzing 12 diuretics by CE-ESI-MS was established in this paper. Ten diuretics (except two neutral compounds) could be fast separated by CE with a DAD at 214 nm with a 20 kV voltage within 6 min, using a 50 microm id and 48.5 cm effective length uncoated fused-silica capillary in a 40 mM ammonium formate buffer (pH 9.40). CE was coupled to the mass spectrometer applying an orthogonal electrospray interface with a triple-tube sheath liquid arrangement. The sheath liquid was composed of isopropanol-water (1:1 v/v) containing 30 mM acetic acid with a flow rate of 4 microL/min. Mass spectrum was employed in the positive mode and both full scan mode and SIM scan mode were utilized. All 12 diuretics could be detected and confirmed by MS in a single analysis. Under optimized conditions, LODs for the 12 diuretics were in the range of 0.13-2.7 micromol/L at an S/N of 3, and the correlation coefficients R(2 )were between 0.9921 and 0.9978. The RDSs (n = 5) of the method was 0.24-0.94 % for migration times and 1.6-8.8 % for peak areas. The recoveries of spiked samples of 12 diuretics were between 72.4% and 118%. The real urine samples were injected directly for analysis, with only simple filtration through a 0.22 microm membrane filter in order to remove solid particles, which may cause capillary blockage. Based on the migration times and characteristic ions, the diuretics in urine samples were detected successfully. This CE-ESI-MS method for analyzing diuretics will hopefully be applied to doping control.  相似文献   

8.
A gas-chromatographic method for the quantitative determination of camylofine dihydrochloride, a spasmolytic agent, is described. The analysis is made on a porous polymer packing material, by determining the 3-methyl-1-butanol formed on alkaline hydrolysis of the drug. The method has been applied to the quantitative determination of the drug in two galenical forms, namely tablets and suppositories, in the presence of papaverine hydrochloride, codeine phosphate, novalgin and aminopyrine.  相似文献   

9.
Two methods, capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), for analysis of cetirizine dihydrochloride in small sample volumes of human plasma were compared. The CE and HPLC assays were developed and validated by analyzing a series of plasma samples containing cetirizine dihydrochloride in different concentrations using these two methods. The extraction procedure is simple and no complicated purification steps or derivatization are required. The analysis time in the HPLC method was shorter than that in the CE method, but solvent consumption was considerably lower in the CE method. The calibration curve was linear to at least 10-1000 ng/mL both for CE and HPLC with r(2) = 0.9993 and r(2) = 0.9994, respectively. The detection limits for cetirizine dihydrochloride were 3 and 5 ng/mL with CE and HPLC (a UV detector was applied in the both cases), respectively. Both methods were selective, robust and specific, allowing reliable quantification of cetirizine dihydrochloride, and could be useful for clinical and biomedical investigations.  相似文献   

10.
11.
This paper deals with the specific identification of several thiazide, potassium-sparing and loop diuretics. The liquid chromatographic behaviour of these compounds is studied. Different organic modifiers (methanol, acetonitrile and tetrahydrofuran) are compared in terms of selectivity for the thiazide diuretics. An acetonitrile-water (40:60) eluent can be used to identify the thiazide diuretics. The loop and potassium-sparing diuretics are well chromatographed at an acidic pH in the presence of propylamine hydrochloride. This study enables us to select the right mobile phase composition for any given selectivity or resolution. The determination of the dead volume in different chromatographic systems is also discussed. A mixture of organic solvent and deuterium oxide in the same volume ratio as the eluent is used as dead volume marker. The signal is monitored with a UV detector at low wavelength.  相似文献   

12.
The doping effects on optical and electrical properties of polysilanes were investigated by in-situ measurement. When polysilanes bearing a p-N,N-dialkylaminophenyl substituent were doped with iodine vapor, drastic spectral changes were observed. The evolved visible absorption up to 700 nm was found to be strong and stable compared to that of iodine-doped polysilanes such as poly(methylphenylsilane). On the basis of the studies concerning iodine doping of the related p-N,N-dimethylaminophenyl-substituted silane and disilane, and also theoretical calculations, this new absorption can be best interpreted by the result of charge transfer consisting of the strong interaction between iodine and dialkylamino substituents in the polysilanes. © 1996 John Wiley & Sons, Inc.  相似文献   

13.
Volatile hydrides of As, Se, Sb and Sn, produced by a continuous manifold hydride generator, have been swept with argon and injected into the plasma of home-made direct current wall-stabilized argon plasma arc via one of its stabilizing segments. The arc burns in argon with an arc current of 20 A and a cathode-anode voltage of 40 V. Measurements were carried out using a 1 m focal length computer-controlled monochromator (Jobin Yvon 1000R) equipped with a holographic grating having 2400 grooves mm 1. Optimal values of the experimental variables that give the highest value of intensity ratio of line-to-background were determined. These are: plasma gas flow rate 1.0 l min 1, carrier gas flow rate 0.35 l min 1 for As and Sb and 0.6 l min 1 for Se and Sn, concentration of nitric acid used for acidification of the sample 2 M for As and Sb, 0.5 M for Se and 0.1 M for Sn and sodium borohydride concentration: 1.5% for As and Se and 2% for Sb and Sn. Chemical interference of some transition elements that affect the hydride generation process and a trial to mask their interference effect were investigated. Calibration curves were linear and limits of detection calculated on the base of 3σ of the background were found to be as low as 3.9, 6.8, 9.8 and 13.2 ng ml 1 for As, Se, Sb and Sn, respectively. Finally, the analytical applicability of the arc device was tested by the determination of As in four lake sediment samples, LKSD 1, LKSD 2, LKSD 3 and LKSD 4, of the Centre for Mineral and Energy Technology, Ottawa, Ontario, Canada, which have been analyzed for As using atomic absorption spectrometry (AAS). The results were in good agreement with those obtained by AAS.  相似文献   

14.
The wavelength range and number of factors used in partial least-squares (PLS) calibration for the resolution of the dihydralazine (DHZ)-hydrochlorothiazide (HCT) binary mixture and the dihydralazine-hydrochlorothiazide-reserpine ternary mixture were optimized in terms of the relative standard error (R.S.E.) and relative mean standard error (R.M.S.E.). Under the optimum conditions thus established, synthetic mixtures of the analytes can be resolved with errors and relative standard deviations (R.S.D) less than 4.5 and 1.0%, respectively. The ensuing method, which was validated by comparison with high performance liquid chromatography (HPLC), also gives good results with real samples (pharmaceutical preparations).  相似文献   

15.
16.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

17.
18.
Three simple, accurate and sensitive spectrophotometric methods are developed for the determination of some new drugs for the treatment of osteoporosis: risedronate sodium (I), alendronate sodium (II) and etidronate disodium (III). The first method is based on the measurement of difference in absorbance (Delta A) of risedronate sodium in 0.01 mol l(-1) hydrochloric and 0.1 mol l(-1) sodium hydroxide at 262 nm. Beer's law is obeyed over a concentration range of 15-150 microg ml(-1) with mean recovery 99.75+/-1.22 and molar absorptivity (epsilon) 1.891 x 10(3). The second method is based on the reaction of the primary amino group of (II) with ninhydrin reagent in methanolic medium in the presence of 0.05 mol l(-1) sodium bicarbonate. The colored product is measured at 568 nm, and the linearity range is found to be 3.75-45 microg ml(-1) with mean recovery 99.77+/-0.73 and epsilon 9.425 x 10(3). The third method is based on oxidation of the three mentioned drugs with ceric (IV) sulphate in 0.5 mol l(-1) sulphuric acid at room temperature and subsequent measurement of the excess unreacted cerium (IV) sulphate at 320 nm. The method obeyed Beer's law over a concentration range of 2-24 microg ml(-1) for the three drugs with mean recovery 99.79+/-1.16, 99.73+/-1.38 and 99.86+/-1.13 and epsilon 14.427 x 10(3), 13.813 x 10(3) and 14.000 x 10(3) for drugs I, II, III respectively. The proposed methods were successfully applied for the determination of the studied drugs in bulk powder and in pharmaceutical formulations. The results were found to agree statistically with those obtained the reported methods. Furthermore, the methods were validated according to USP regulations and also assessed by applying the standard addition technique.  相似文献   

19.
Zheng X  Lu M  Zhang L  Chi Y  Zheng L  Chen G 《Talanta》2008,76(1):15-20
A simple and sensitive online field-amplification sample stacking (FASS) pre-enrichment method following by capillary electrophoresis with amperometric detection has been developed for the determination of diuretics, such as indapamide (IDP), hydrochlorothiazide (HCT) and bumetanide (BMTN) in urine. Under the optimum conditions, it was found that the low concentration buffer solution could be used as the diluents for simultaneous field-amplification injection of three diuretics after electrokinetically injecting a short water plug (15 kV, 3 s). Three analytes could be well separated within 10 min in an uncoated fused-silica capillary with H(3)BO(3)-Na(2)B(4)O(7) (BB) buffer solution (pH 8.98). The detection limits (S/N=3) were 9.0 ng/mL for IDP, 20 ng/mL for HCT and 1.5 ng/mL for BMTN, respectively. The detection limits of three diuretics were much lower by FASS than that by conventional sample injection, of which the detection limits were 340, 890 and 330 ng/mL for IDP, HCT and BMTN, respectively. Especially, for bumetanide the detection limit was 220-time lower by FASS. The linear ranges of three diuretics were all over three orders of magnitude. The proposed method has been successfully applied to analyze the diuretics in human urine samples without off-column sample pre-concentration.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号