首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The connectivity between functionally distinct areas in the human brain is unknown because of the limitations posed by current postmortem anatomical labeling techniques. Diffusion tensor imaging (DTI) has previously been used to define large white matter tracts based on well-known anatomical landmarks in the living human brain. In the present study, we used DTI coupled with functional magnetic resonance imaging (fMRI) to assess neuronal connections between human striate and functionally defined extrastriate ventral cortical areas. Functional areas were identified with conventional fMRI mapping procedures and then used as seeding points in a DTI analysis to ascertain connectivity patterns between cortical areas, thus yielding the pattern of connections between human occipitoventral visual areas in vivo.  相似文献   

2.
The in vivo biocompatibility of pure sapphire and borosilicate glass (BSG) implanted onto the cerebral cortex was studied via magnetic resonance imaging (MRI) and histopathology. Each implant was embedded onto the cortical surface of an adult rat brain for a total of 28 days. Rats underwent surgery with and without implants, and rats with purposely damaged cortical implant sites were also studied. Each animal was imaged via MRI before surgery as well as 10 and 28 days after the surgery. Histopathological results of animals were obtained on the 28th day to determine the specific effect on neurons. Despite the fact that sapphire has been widely used in a variety of medical implants, both MRI and histopathological results indicate that pure sapphire is not biocompatible with the cerebral cortex. On the contrary, BSG implants appear to be biocompatible with the cortical surface.  相似文献   

3.
Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM, in the present study, a combined exploration with fMRI and transcranial magnetic stimulation was performed in a patient with a right rolandic AVM in order to explore the relationship between neuronal and hemodynamic activity. The combined protocol of investigation adopted in this study was able to provide significant information regarding neuronal activity of the different cortical areas that partake to post-lesional reorganization.  相似文献   

4.
In this paper, advanced methods for the modeling of human cortical activity from combined high-resolution electroencephalography (EEG), magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI) data are presented. These methods include a subject's multicompartment head model (scalp, skull, dura mater, cortex) constructed from magnetic resonance images, multidipole source model and regularized linear inverse source estimates of cortical current density. Determination of the priors in the resolution of the linear inverse problem was performed with the use of information from the hemodynamic responses of the cortical areas as revealed by block-designed (strength of activated voxels) fMRI. Examples of the application of these methods to the estimation of the time varying cortical current density activity in selected region of interest (ROI) are presented for movement-related high-resolution EEG data.  相似文献   

5.
PurposeWe present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner.MethodsA 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a nominal TE of 32 μs, was employed for high contrast morphological imaging of cortical bone in the hip of heathy volunteers. Signals from soft tissues such as muscle and marrow fat were suppressed via adiabatic inversion and signal nulling. T2 value of the cortical bone was also calculated based on 3D IR-UTE-Cones acquisitions with a series of TEs ranging from 0.032 to 0.8 ms. A total of four healthy volunteers were recruited for this study. Average T2 values and the standard deviation for four regions of interests (ROIs) at the greater trochanter, the femoral neck, the femoral head and the lesser trochanter were calculated.ResultsThe 3D IR-UTE-Cones sequence provided efficient suppression of soft tissues with excellent image contrast for cortical bone visualization in all volunteer hips. Exponential single component decay was observed for all ROIs, with averaged T2 values ranging from 0.33 to 0.45 ms, largely consistent with previously reported T2 values of cortical bone in the tibial midshaft.ConclusionsThe 3D IR-UTE-Cones sequence allows in vivo volumetric imaging and quantitative T2 measurement of cortical bone in the hip using a clinical 3T scanner.  相似文献   

6.
The effect of caffeine as a cognitive enhancer is well known; however, caffeine-induced changes in the cortical regions are still not very clear. Therefore, in this study, we conducted an investigation of the activation and deactivation with blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) and of metabolic activity change with positron emission tomography (PET) in the human brain.  相似文献   

7.
Motor imagery is an experimental paradigm implemented in cognitive neuroscience and cognitive psychology. To investigate the asymmetry of the strength of cortical functional activity due to different single-hand motor imageries, functional magnetic resonance imaging (fMRI) data from right handed normal subjects were recorded and analyzed during both left-hand and right-hand motor imagery processes. Then the average power of blood oxygenation level-dependent (BOLD) signals in temporal domain was calculated using the developed tool that combines Welch power spectrum and the integral of power spectrum approach of BOLD signal changes during motor imagery. Power change analysis results indicated that cortical activity exhibited a stronger power in the precentral gyrus and medial frontal gyrus with left-hand motor imagery tasks compared with that from right-hand motor imagery tasks. These observations suggest that right handed normal subjects mobilize more cortical nerve cells for left-hand motor imagery. Our findings also suggest that the approach based on power differences of BOLD signals is a suitable quantitative analysis tool for quantification of asymmetry of brain activity intensity during motor imagery tasks.  相似文献   

8.
Surface neural activity has been widely visualized using optical intrinsic signal imaging (OISI) from various cortical sensory areas. OISI of the cortical surface with a CCD camera gives integrated information across a depth of a few hundred micrometers. We visualize depth-resolved activation patterns of cat primary visual cortex by functional optical coherence tomography (fOCT). A comparison of the depth-integrated results of fOCT maps with the optical intrinsic signal profiles shows fairly good agreement. Our results reveal layer-specific activation patterns and indicate that the activation was not homogeneous.  相似文献   

9.
There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was generated with acquisitions using dual echo 3D UTE with echo subtraction, dual echo 3D UTE with rescaled subtraction, long T2 saturation 3D UTE, long T2 saturation dual echo 3D UTE with echo subtraction, single adiabatic inversion recovery 3D UTE, single adiabatic inversion recovery dual echo 3D UTE with echo subtraction and dual adiabatic inversion recovery 3D UTE. The feasibility of using these approaches was demonstrated in in vitro and in vivo imaging of calcified cartilage, aponeuroses, menisci, tendons, ligaments and cortical bone with a 3-T clinical MR scanner. Signal-to-noise ratios and contrast-to-noise ratios were used to compare the techniques.  相似文献   

10.
Optical imaging of an exposed cortex for brain function measurement is an attractive method for both clinical and physiological investigations. Spectral imaging of the exposed cortical tissue enables measurement of the activity-dependent changes in oxy- and deoxy-haemoglobin independently. Since the diffusely reflected light from the exposed cortex is highly scattered in the cortical tissue, the wavelength dependence of the optical properties of the tissue is likely to affect the images of oxy- and deoxy-haemoglobin changes obtained from the spectral images. In this study, the spectral images of the model of exposed cortical tissue are calculated by Monte Carlo simulation to investigate the influence of blurring by tissue scattering on the brain function measurement by the imaging. The images of the change in oxy- and deoxy-haemoglobin obtained from the spectral images at near infrared wavelengths are broadened and blurred due to the scattering in the cortical tissue. The influence of cross talk is more significant in the image calculated from the spectral images at the visible wavelengths. Inappropriate choice of the spectral range of images might increase cross talk and error in the images of oxy- and deoxy-haemoglobin changes.  相似文献   

11.
We test a hypothesis that proton T(1) is accurately measured independent of the physics inherent to the method. We used two well-validated but quite different imaging methods to measure T(1) in phantoms and in humans; an echo-planar imaging T-one measurement (EPITOME) method, and a segmented k-space acquisition precise and accurate inversion recovery (TurboPAIR) method. Agreement between the methods was generally excellent; the square of the correlation coefficient (r(2)) in phantoms was 0.9996. The r(2) in brain tissue of volunteers was 0.79 overall, and 0.85 if cortical gray matter and corpus callosum were excluded. Nevertheless, small but significant differences were observed between methods in vivo and T(1) measurements were sensitive to tissue type, although measurements could be made comparable. The major difference between the methods is that EPITOME takes 97 s to image 15 slices at low resolution, while TurboPAIR takes 240 s to image one slice at high resolution.  相似文献   

12.
The blood oxygenation level-dependent (BOLD) effect is the most commonly used contrast mechanism in functional magnetic resonance imaging (fMRI), due to its relatively high spatial resolution and sensitivity. However, the ability of BOLD fMRI to accurately localize neuronal activation in space and time is limited by the inherent hemodynamic modulation. There is hence a need to develop alternative MRI methods that can directly image neuroelectric activity, thereby achieving both a high temporal resolution and spatial specificity as compared to conventional BOLD fMRI. In this paper, we extend the Lorentz effect imaging technique, which can detect spatially incoherent yet temporally synchronized minute electrical activity in a strong magnetic field, and demonstrate its feasibility for imaging randomly oriented electrical currents on the order of microamperes with a temporal resolution on the order of milliseconds in gel phantoms. This constitutes a promising step towards its application to direct imaging of neuroelectric activity in vivo, which has the same order of current density and temporal synchrony.  相似文献   

13.
The noninvasive imaging of the monkey auditory system with functional magnetic resonance imaging (fMRI) can bridge the gap between electrophysiological studies in monkeys and imaging studies in humans. Some of the recent imaging of monkey auditory cortical and subcortical structures relies on a technique of “sparse imaging,” which was developed in human studies to sidestep the negative influence of scanner noise by adding periods of silence in between volume acquisition. Among the various aspects that have gone into the ongoing optimization of fMRI of the monkey auditory cortex, replacing the more common continuous-imaging paradigm with sparse imaging seemed to us to make the most obvious difference in the amount of activity that we could reliably obtain from awake or anesthetized animals. Here, we directly compare the sparse- and continuous-imaging paradigms in anesthetized animals. We document a strikingly greater auditory response with sparse imaging, both quantitatively and qualitatively, which includes a more expansive and robust tonotopic organization. There were instances where continuous imaging could better reveal organizational properties that sparse imaging missed, such as aspects of the hierarchical organization of auditory cortex. We consider the choice of imaging paradigm as a key component in optimizing the fMRI of the monkey auditory cortex.  相似文献   

14.
In vivo optical imaging has become a popular tool in animal laboratories. Currently, many in vivo optical imaging systems are available on the market, which often makes it difficult for research groups to decide which system fits their needs best. In this work we compared different commercially available systems, which can measure both bioluminescent and fluorescent light. The systems were tested for their bioluminescent and fluorescent sensitivity both in vitro and in vivo. The IVIS Lumina II was found to be most sensitive for bioluminescence imaging, with the Photon Imager a close second. Contrary, the Kodak system was, in vitro, the most sensitive system for fluorescence imaging. In vivo, the fluorescence sensitivity of the systems was similar. Finally, we examined the added value of spectral unmixing algorithms for in vivo optical imaging and demonstrated that spectral unmixing resulted in at least a doubling of the in vivo sensitivity. Additionally, spectral unmixing also enabled separate imaging of dyes with overlapping spectra which were, without spectral unmixing, not distinguishable.  相似文献   

15.
Functional MRI (fMRI) was used to investigate the effects of psychotropic compound activity in the rat brain in vivo. The effects of dizocilpine (MK-801) an N-methyl-D-aspartate receptor antagonist and m-chlorophenylpiperazine (mCPP), a 5-HT(2b/2c)-receptor agonist on rat brain activity were investigated over a time interval of about 1 h and the results were compared to published glucose utilisation and cerebral blood flow data. Signal magnitude increases were observed predominantly in limbic regions following MK-801 administration (0.5 mg/kg i.v) whereas signal decreases were restricted to neocortical areas; a characteristic, time dependent pattern of regional changes evolved from the thalamic nuclei to cortical regions. In contrast, mCPP (25 mg/kg i.p) produced gradual signal intensity increases in limbic and motor regions with signal decreases restricted to the visual, parietal and motor cortices. The results from both compounds show remarkable similarity with autoradiographic measurements of cerebral blood flow and glucose uptake. These experiments suggest that the spatio-temporal capabilities of fMRI may be applied to the in vivo investigation of psychoactive compound activity with potential for clinical applications.  相似文献   

16.
Different brain imaging devices are presently available to provide images of the human functional cortical activity, based on hemodynamic, metabolic or electromagnetic measurements. However, static images of brain regions activated during particular tasks do not convey the information of how these regions are interconnected. The concept of brain connectivity plays a central role in the neuroscience, and different definitions of connectivity, functional and effective, have been adopted in literature. While the functional connectivity is defined as the temporal coherence among the activities of different brain areas, the effective connectivity is defined as the simplest brain circuit that would produce the same temporal relationship as observed experimentally among cortical sites. The structural equation modeling (SEM) is the most used method to estimate effective connectivity in neuroscience, and its typical application is on data related to brain hemodynamic behavior tested by functional magnetic resonance imaging (fMRI), whereas the directed transfer function (DTF) method is a frequency-domain approach based on both a multivariate autoregressive (MVAR) modeling of time series and on the concept of Granger causality.

This study presents advanced methods for the estimation of cortical connectivity by applying SEM and DTF on the cortical signals estimated from high-resolution electroencephalography (EEG) recordings, since these signals exhibit a higher spatial resolution than conventional cerebral electromagnetic measures. To estimate correctly the cortical signals, we used a subject's multicompartment head model (scalp, skull, dura mater, cortex) constructed from individual MRI, a distributed source model and a regularized linear inverse source estimates of cortical current density. Before the application of SEM and DTF methodology to the cortical waveforms estimated from high-resolution EEG data, we performed a simulation study, in which different main factors (signal-to-noise ratio, SNR, and simulated cortical activity duration, LENGTH) were systematically manipulated in the generation of test signals, and the errors in the estimated connectivity were evaluated by the analysis of variance (ANOVA). The statistical analysis returned that during simulations, both SEM and DTF estimators were able to correctly estimate the imposed connectivity patterns under reasonable operative conditions, that is, when data exhibit an SNR of at least 3 and a LENGTH of at least 75 s of nonconsecutive EEG recordings at 64 Hz of sampling rate.

Hence, effective and functional connectivity patterns of cortical activity can be effectively estimated under general conditions met in any practical EEG recordings, by combining high-resolution EEG techniques and linear inverse estimation with SEM or DTF methods. We conclude that the estimation of cortical connectivity can be performed not only with hemodynamic measurements, but also with EEG signals treated with advanced computational techniques.  相似文献   


17.
Brain asymmetry is a phenomenon well known for handedness and has been studied in motor cortices. However, few quantitative studies on asymmetrical cortical activity in motor areas have been conducted. In this study, we systematically investigated asymmetrical cortical activity in motor areas during sequential finger movement by quantitatively analyzing functional magnetic resonance imaging (fMRI) blood oxygenation level-dependent (BOLD) responses. The norm of BOLD signal percentage of change was introduced to quantitatively measure the BOLD signal intensity change difference between the left and right motor areas. The results of the data collected from six subjects show that the norm of BOLD signal percentage of change in the right motor area is higher than that in the left motor area for two-hand movement (P=.0059) and single-hand movement (P=.0279) with right-handedness. These results from fMRI show the asymmetry of motor areas and may suggest that the left hemisphere motor area comes into being as an adaptation system that needs few neuron cells only to finish any movement task for right-handedness. The activation intensity in the left motor area is reduced with normal right finger movement. The activation intensity in the right motor area is obviously higher than that in the left motor area.  相似文献   

18.
Ultrashort TE (UTE) sequences allow direct visualization of tissues with very short T2 relaxation times, such as tendons, ligaments, menisci, and cortical bone. In this work, theoretical calculations, simulations, and phantom studies, as well as in vivo imaging were performed to maximize signal-to-noise ratio (SNR) for slice selective RF excitation for 2D UTE sequences. The theoretical calculations and simulations were based on the Bloch equations, which lead to analytic expressions for the optimal RF pulse duration and amplitude to maximize magnetic resonance signal in the presence of rapid transverse relaxation. In steady state, it was found that the maximum signal amplitude was not obtained at the classical Ernst angle, but at an either lower or higher flip angle, depending on whether the RF pulse duration or amplitude was varied, respectively.  相似文献   

19.
《Radiation measurements》2009,44(2):206-210
There has been an increased interest in beta therapeutic nuclear medicine, which emits relatively high-energy (>1 MeV) β-rays and the production in vivo of Bremsstrahlung sufficient for external imaging, the produced Bremsstrahlung radiation hazard warrants evaluation. The Bremsstrahlung dose from patient administered β-ray emitted radionuclide has been calculated by extending the national council on Radiation Protection and measurement model of a point source in air to account for biologic elimination of activity. We have estimated the probability of bremsstrahlung production, specific Bremsstrahlung constant (defined by Zanzonico et al.) and activity (Arelease) in bone cortical, bone compact, different regions of tooth enamel (enamel dentin junction (EDJ), enamel middle surface, enamel inner surface), different regions of dentin (outer surface, middle surface, enamel dentin junction (EDJ)), soft tissue, lungs and skeleton for different therapeutic beta-emitting radionuclide. In the present calculations we have used modified atomic number (Zmod) defined for bremsstrahlung process.Proper localization and quantification of incorporated beta emitters in bone and tooth are possible, because Bremsstrahlung production is greater in bone and tooth than soft tissue due to their high modified atomic number (Zmod). Radionuclide therapy with pure β-ray emitters emitted in bone, tooth, soft tissue, lungs and skeleton does not require medical confinement of patients for radiation protection.  相似文献   

20.
Magnetic resonance imaging of cortical lesions due to multiple sclerosis (MS) has been hampered by the lesions' small size and low contrast to adjacent, normal-appearing tissue. Knowing cortical lesion T1 and proton density (PD) would be highly beneficial for the process of developing and optimizing dedicated magnetic resonance (MR) sequences through computer modeling of MR tissue responses. Eight patients and seven healthy control subjects were scanned at 7 T using a series of inversion recovery turbo field echo scans with varying inversion times. Regions of interest were drawn in white matter, gray matter, cortical lesions, white matter lesions and cerebrospinal fluid. White matter and gray matter T1s were significantly higher in MS patients than in controls. Cortical and white matter lesion T1 and PD are also presented for the first time. The advantages of ultrahigh field MR imaging will be important for future investigations in MS research and sequence optimization for the detection of cortical lesions.  相似文献   