首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The partial least squares (PLS-1) calibration model based on spectrophotometric measurement, for the simultaneous determination of CN and SCN ions is described. The method is based on the difference in the rate of the reaction between CN and SCN ions with chloramine-T in a pH 4.0 buffer solution and at 30 °C. The produced cyanogen chloride (CNCl) reacts with pyridine and the product condenses with barbituric acid and forms a final colored product. The absorption kinetic profiles of the solutions were monitored by measuring absorbance at 578 nm in the time range 20-180 s after initiation of the reaction with 2 s intervals. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 31 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 10.0-900.0 and 50.0-1200.0 ng mL−1 for CN and SCN ions, respectively. The proposed method was successfully applied to the simultaneous determination of cyanide and thiocyanate in water samples.  相似文献   

2.
将偏最小二乘法(PLS)用于紫外分光光度数据的解析,建立了同时测定甲基苯甲醛3种同分异构体的模型。在230~304 nm范围内,将测得的48个样品的吸光度值作为校正集,另18个样品的吸光度值作为预测集用于建模。所建立的邻、间、对甲基苯甲醛模型的平均回收率分别为101.2%、100.2%和98.9%;均方根误差(RMSE)分别为0.2667、0.3853和0.2118;预测浓度范围分别为4.6~16.2μg/mL、5.8~17.4μg/mL和6.5~20.6μg/mL。讨论了混合物中3种同分异构体浓度比例对测定结果的影响,并确定了最佳的浓度比例范围。对模拟样品进行加标回收率试验。并通过与顺、反丁烯二酸两种同分异构体测定结果的比较,得出了有意义的结论。  相似文献   

3.
Abbaspour A  Najafi M 《Talanta》2003,60(5):1079-1084
A method for simultaneous spectrophotometric determination of Sb(III) and Sb(V) using multivariate calibration method is proposed. This method is based on the development of the reaction between the analytes and pyrogallol red at pH 2.00. The selection of variables was studied. A series of synthetic solutions containing different concentrations of Sb(III) and Sb(V) were used to check the prediction ability of the partial least squares model. The calibration curves were linear over the range of 0.3-3.4 and 0.3-3.0 μg ml−1 for Sb(III) and Sb(V), respectively. The detection limits were 0.177 and 0.200 μg ml−1 for Sb(III) and Sb(V), respectively.  相似文献   

4.
Ren S  Gao L 《Talanta》2000,50(6):1163-1173
The mathematical bases and program algorithms of discrete wavelet transform (DWT), multiresolution and Mallat’s pyramid algorithm were described. The multiresolution analysis (MRA) based on Daubechies orthogonal wavelet basis was studied as a tool for removing noise and irrelevant information from spectrophotometric spectra. After wavelet MRA pre-treatment, eight error functions were calculated for deducing the number of factors. A partial least squares based on wavelet MRA (WPLS) method was developed to perform simultaneous spectrophotometric determination of Fe(II) and Fe(III) with overlapping peaks. Data reduction was performed using wavelet MRA and principal component analysis (PCA) algorithm. Two programs, SPWMRA and SPWPLS, were designed to perform wavelet MRA and simultaneous multicomponent determination. Experimental results showed the WPLS method to be successful even where there was severe overlap of spectra.  相似文献   

5.
痕量Fe^3 ,Mn^2 ,Cu^2 ,Zn^2 ,Co^2 ,Ni^2 与2-(5-溴-2-吡啶偶氮)-5-二乙氨基苯酚(5-Br-PADAP)和溴化十六烷基三甲基铵(CTMAB)在PH8.3时发生高灵敏显色反应,所形成的三元胶束络合的吸收光谱严重重叠,采用偏最小二乘法(PLS)辅助分光光度法测定了合成试样及饲料中上述6种痕量组分,结果表明,PLS法是化学计量学中一种可适用于基体较复杂的实际试样中痕量组分分光度同时测定的多元计算方法。  相似文献   

6.
将偏最小二乘法(PLS)用于同步荧光光谱严重重叠的多柔比星(doxorubicin, DOX)和柔红霉素(daunorubicin, DNR)两组分混合体系进行波谱解析, 建立了该混合体系含量同时测定的新方法. 在pH 3.45 B-R缓冲溶液中, 波长差Δλ=55 nm时, 用测得的25个混合标样的同步荧光原始光谱、一阶导数光谱值建立模型. DOX和DNR在质量浓度为0.05~3.0 μg/mL范围内呈现良好的线性关系, 所建立的测定二者模型的相关系数分别为0.9897和0.9909; 平均回收率分别为101.0%和101.4%; 预测均方根误差(RMSEP)分别为0.1400和0.1395; 预测相对标准误差(SEP)分别为0.1541和0.1525. 该方法可应用于尿液样品的分析测定.  相似文献   

7.
A novel method named OSC-WPT-PLS approach based on partial least squares (PLS) regression with orthogonal signal correction (OSC) and wavelet packet transform (WPT) as pre-processed tools was proposed for the simultaneous spectrophotometric determination of Al(III), Mn(II) and Co(II). This method combines the ideas of OSC and WPT with PLS regression for enhancing the ability of extracting characteristic information and the quality of regression. OSC is used to remove information in the response matrix D by subtracting the structured noise that is orthogonal to the concentration matrix C. Wavelet packet transform was applied to perform data compression, to extract relevant information, and to eliminate noise and collinearity. PLS was applied for multivariate calibration and noise reduction by eliminating the less important latent variables. In this case, using trials, the kind of wavelet function, the decomposition level, the number of OSC components and the number of PLS factors for the OSC-WPT-PLS method were selected as Daubechies 4, 3, 2 and 3, respectively. A program (POSCWPTPLS) was designed to perform the simultaneous spectrophotometric determination of Al(III), Mn(II) and Co(II). The relative standard errors of prediction (RSEP) obtained for total elements using OSC-WPT-PLS, WPT-PLS and PLS were compared. Experimental results demonstrated that the OSC-WPT-PLS method had the best performance among the three methods and was successful even when there was severe overlap of spectra.  相似文献   

8.
A partial least squares (PLS-1) calibration model based on kinetic—spectrophotometric measurement, for the simultaneous determination of Cu(II), Ni(II) and Co(II) ions is described. The method was based on the difference in the rate of the reaction between Co(II), Ni(II) and Cu(II) ions with 1-(2-pyridylazo)2-naphthol in a pH 5.8 buffer solution and in micellar media at 25°C. The absorption kinetic profiles of the solutions were monitored by measuring the absorbance at 570 nm at 2 s intervals during the time range of 0–10 min after initiation of the reaction. The experimental calibration matrix for the partial least squares (PLS-1) model was designed with 30 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.1-2 μg mL−1 for each cation. The proposed method was successfully applied to the simultaneous determination of Cu(II), Ni(II) and Co(II) ions in water and in synthetic alloy samples.   相似文献   

9.
利用紫外可见分光光度法研究了农药福美锌和代森锰与苯基荧光酮的相互作用,发现反应后的产物分别在波长为551和554 nm处最大有吸收,但光谱严重重叠.实验采集了450~700 nm波长范围吸光度数据,并对该数据进行一阶求导后用偏最小二乘法处理,据此建立了偏最小二乘-分光光度法同时测定福美锌和代森锰两种农药的新方法.福美锌和代森锰的线性范围分别为0.3~6.0和0.2~3.5 μg/mL;检出限分别为0.22和0.13 μg/mL.混合样品分析无需分离,方法简单、快速.用于水果、大米和自来水等实际样品测定.  相似文献   

10.
A simple, sensitive and selective spectrophotometric method for simultaneous determination of tretinoin and minoxidil using partial least square (PLS) calibration and H-point standard addition method (HPSAM) is described. The results of the H-point standard addition method show that minoxidil and tretinoin can be determined simultaneously with the concentration ratio of tretinoin to minoxidil varying from 2: 1 to 1: 33 in mixed samples. A partial least squares multivariate calibration method for the analysis of binary mixtures of tretinoin and minoxidil was also developed. The total relative standard error for applying the PLS method to eleven synthetic samples in the concentration range of 0–10 μg mL−1 tretinoin and 0–32 μg mL−1 minoxidil was 2.59 %. Both proposed methods (PLS and HPSAM) were also successfully applied in the determination of tretinoin and minoxidil in several synthetic pharmaceutical solutions.  相似文献   

11.
Two spectrophotometric methods for the determination of Ethinylestradiol (ETE) and Levonorgestrel (LEV) by using the multivariate calibration technique of partial least square (PLS) and principal component regression (PCR) are presented. In this study the PLS and PCR are successfully applied to quantify both hormones using the information contained in the absorption spectra of appropriate solutions. In order to do this, a calibration set of standard samples composed of different mixtures of both compounds has been designed. The results found by application of the PLS and PCR methods to the simultaneous determination of mixtures, containing 4–11 μg ml−1 of ETE and 2–23 μg ml−1 of LEV, are reported. Five different oral contraceptives were analyzed and the results were very similar to that obtained by a reference liquid Chromatographic method.  相似文献   

12.
Simultaneous determination of total iron and vanadium by H-point standard addition method (HPSAM) and partial least squares (PLS) is described. Gallic acid (GA) in a cationic micellar solution of CTAB was used for determination of iron and vanadium in different oxidation states at pH 5. The presence of a micellar system enables total iron and vanadium to be determined with improved sensitivities. The total relative standard error for applying the PLS method to 15 synthetic samples in the ranges 0.20–15.00 μg ml−1 iron and 0.20–8.00 μg ml−1 vanadium was 2.2%. The results of applying the H-point standard addition method showed that iron and vanadium can be determined simultaneously with the concentration ratios of iron to vanadium from 10:1 to 1:20 in the mixed sample. Both HPSAM and PLS methods showed suitable abilities to resolve accurately overlapped absorption spectra of the compounds. Both proposed methods were successfully applied to the determination of Fe and V in several synthetic alloy solutions.  相似文献   

13.
The partial least squares (PLS) applied to the simultaneous determination of the divalent ions of copper, nickel, cobalt and zinc based on the formation of their complexes with 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (zincon). The absorption spectra were recorded from 515 through 750 nm. The effect of pH on sensitivity and the selectivity was studied in the range 3.0-10.0 and the pH 8.0 was choused according to net analyte signal (NAS) as a function of pH. The concentration range for Cu2+, Ni2+, Co2+and Zn2+ in solution calibration sets were 0-2.6, 0-4.6, 0-3.0 and 0-4.92 ppm, respectively. The root mean squares differences (RMSD) for copper, nickel, cobalt and zinc were 0.0181, 0.0488, 0.0309 and 0.0463, respectively.  相似文献   

14.
Two alternative partial least squares (PLS) methods, averaged PLS and weighted average PLS, are proposed and compared with the classical PLS in terms of root mean square error of prediction (RMSEP) for three real data sets. These methods compute the (weighted) average of PLS models with different complexity. The prediction abilities of the alternative methods are comparable to that of the classical PLS but they do not require to determine how many components should be included in the model. They are also more robust in the sense that the quality of prediction depends less on a good choice of the number of components to be included. In addition, weighted average PLS is also compared with the weighted average part of LOCAL, a published method that also applies weighted average PLS, with however an entirely different weighting scheme.  相似文献   

15.
16.
Simultaneous determination of Fe(II) and Fe(III) was studied using partial least squares regression (PLS) and principal component regression (PCR) methods. The models were based on the difference observed in the rates of the complex formation of iron in its two oxidation states with 1,2-naphthaquinone-2-thiosemicarbazone-4-sulphonic acid (NQT4S) at pH 4.0 in cetyltrimethylammoniumbromide (CTAB) as micellar media. The results showed that simultaneous determination of Fe(II) and Fe(III) could be performed in their concentration ranges of 0.10-2.10 and 0.25-2.25 μg/ml, respectively. The models used can proceed the data with low percent relative error of prediction (i.e. <5.5%). The procedure was successfully applied for the simultaneous determination of Fe(II) and Fe(III) in some environmental samples. The method would allow the transformation of the two oxidation states of iron to be monitored overtime in a water sample.  相似文献   

17.
Two spectrophotometric methods are described for the simultaneous determination of binary mixtures of Sn(II) and Sn(IV) in water samples and fruit juice samples, without prior separation steps, using the mean centering of ratio kinetic profiles and partial least squares (PLS) methods. The methods are based on the difference in the rate of the reactions of Sn(II) and Sn(IV) with pyrocatechol violet at pH 4.0. The methods allow rapid and accurate determination of Sn(II) and Sn(IV). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Sn(II) and Sn(IV) were calculated. The results showed that the methods were capable to simultaneous determination of 0.1–1.80 mg L−1 each of cations. The proposed methods were successfully applied to the simultaneous determination of Sn(II) and Sn(IV)in an orange juice sample.  相似文献   

18.
Partial least squares regression (PLS) is proposed for solving ir pollution source apportionment problems as an alternative method to the frequently used chemical mass balance technique. A discriminant PLS is used to calculate linear mixing proportions for a synthetic ambient aerosol data set where the truth is known. Without sacrificing orthogonality of the source profiles, PLS can resolve the emission sources and accurately predict the emission source contributions. Further extensions of the PLS approach to environmental receptor modelling are discussed.  相似文献   

19.
Near-infrared spectroscopy(NIR),which is generally used for online monitoring of the food analysis and production process, was applied to determine the internal quality of toothpaste samples.It is acknowledged that the spectra can be significantly influenced by non-linearities introduced by light scatter,therefore,four data preprocessing methods,including off-set correction, 1st-derivative,standard normal variate(SNV) and multiplicative scatter correction(MSC),were employed before the date analysis. The multivariate calibration model of partial least squares(PLS) was established and then was used to predict the pH values of the toothpaste samples of different brand.The results showed that the spectral date processed by MSC was the best one for predicting the pH value of the toothpaste samples.  相似文献   

20.
Ghasemi J  Niazi A 《Talanta》2005,65(5):1168-1173
The simultaneous determination of nitroaniline isomer mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removes the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 200–500 nm range for 21 different mixtures of nitroaniline isomers. Calibration matrices were containing 1–21, 1–15 and 1–18 μg ml−1 of m-nitroaniline, o-nitroaniline and p-nitroaniline, respectively. The RMSEP for m-nitroaniline, o-nitroaniline and p-nitroaniline with OSC and without OSC were 0.6567, 0.2692, and 0.3134, and 1.3818, 1.2181, and 0.3953, respectively. This procedure allows the simultaneous determination of nitroaniline isomers in real matrix samples and good reliability of the determination was proved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏