首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
External ion accumulation in a two-dimensional (2D) multipole trap has been shown to increase the sensitivity, dynamic range and duty cycle of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. However, it is important that trapped ions be detected without significant bias at longer accumulation times in the external 2D multipole trap. With increasing ion accumulation time pronounced m/z discrimination was observed when trapping ions in an accumulation quadrupole. In this work we show that superimposing lower rf-amplitude dipolar excitation over the main rf-field in the accumulation quadrupole results in disruption of the m/z discrimination and can potentially be used to achieve unbiased external ion accumulation with FTICR.  相似文献   

2.
Dynamic control of bath gas pressure in a quadrupole ion trap (QIT) achieved high sensitivity and broad dynamic range infrared multiphoton dissociation (IRMPD). Conventional IRMPD is not sensitive because the bath gas pressure in the QIT needs to be kept at less than 1 mTorr for an effective dissociation, whereas the pressure should be about 20 mTorr for maximum trapping efficiency during ion accumulation. By switching the bath gas pressure between about 20 mTorr during the ion accumulation period and less than 0.6 mTorr during the IRMPD period, it was possible to achieve both maximum trapping efficiency and effective IRMPD. An optimized method for gas introduction enables the trapping efficiency to remain constant during the accumulation period, which permits a broad dynamic range measurement.  相似文献   

3.
The dynamic range of Fourier transform ion cyclotron mass spectrometry (FTICR) is typically limited by the useful charge capacity of an FTICR cell (to approximately 10(6) to 10(7) elementary charges) and the minimum number of ions required to produce a useful signal (approximately 10(2) elementary charges). We show that the expansion of the dynamic range by 2 orders of magnitude can be achieved by preselecting lower abundance species in a quadrupole interface to an electrospray ionization (ESI) source. Ion preselection is then followed by ion accumulation in external to the FTICR cell a linear (2-D) quadrupole trap and subsequent transfer to the region of high magnetic field for gated trapping in the FTICR cell. Two modes of ion preselection, using either the quadrupole filtering mode or rf-only dipolar excitation, were studied and mass resolutions of 30 to 100 were achieved for selective external ion accumulation of peptides and proteins with molecular weights ranging from 500 to 17,000 Da. The ability to selectively eject the most abundant species before trapping in the FTICR has enormous practical benefits for increasing the sensitivity and dynamic range of measurements.  相似文献   

4.
A new method of ion deceleration in a Fourier transform ion cyclotron resonance (FTICR) open cell is described that improves the performance of FTICR-MS instruments equipped with an internal source for laser desorption/ionization. Ion deceleration occurs in the front trapping cylinder of an open cylindrical cell. Decelerating voltages up to 100 V can be applied for 10-500 micros to the front cylinder during ion introduction. The deceleration field is uniformly distributed along the cylinder length giving a "smooth" deceleration, which means that the deceleration is effective over a large time interval and a large m/z range. This results in improved trapping efficiency of high-energy ions. We demonstrate efficient trapping of high (m/z 66 kDa) mass ions and the possibility to reduce the width of the kinetic energy distribution of MALDI ions with this arrangement.  相似文献   

5.
This study outlines some observations of the pressure effect for gas phase ion-molecule reactions of anthraquinone derivatives with dimethyl ether in an external source ion trap mass spectrometer. At the reagent pressure of 7.998 x 10(-2) Pa, formation of the protonated ions, [M + 13]+, [M + 15]+, and [M + 45]+ ions, of anthraquinones can be observed. However, at the pressure of 1.066 x 10(-2) Pa, formation of molecular ions and many fragment ions of the M+. or [M + H]+ ions have been observed. Since the pressure effect is notable within a small range of pressures for many compounds, it is important to draw attention to the use of the ion trap with an external source where other factors such as ion source residence time may play a role. This can also provide some information for better and more careful controls of the reagent pressure in order to obtain fair CI spectra in an external source ion trap mass spectrometer.  相似文献   

6.
A new internal matrix-assisted laser desorption-ionization (MALDI) Fourier transform ion cyclotron resonance-mass spectrometry (FTICR-MS) method is introduced. The target is directly positioned at one trapping electrode of a single cylindrical ion cyclotron resonance (ICR) cell and becomes a part of it. The ionization occurs inside the ICR cell in contrast to external or near-cell MALDI-FTICR-MS techniques. Very efficient trapping and mass resolving power better than unit resolution of singly charged peptides and proteins ions up to 2000 u is possible by using only basic FTICR-MS techniques. The sole application of a pulsed retarding potential increases the mass range to 6000 u. No collisional cooling and quadrupolar excitation was done. Sensitivities below 1 fmol, and ion storage times of more than 15 s are shown. High resolving powers of 16,000 and 56,000 are obtained on bovine insulin (5.7 ku) and gramicidin D (1.9 ku), respectively.  相似文献   

7.
Doubly-protonated bradykinin (RPPGFSPFR) and an angiotensin III analogue (RVYIFPF) were subjected to hydrogen/deuterium (H/D) exchange with CD(3)OD in a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. A bimodal distribution of deuterium incorporation was present for bradykinin after H/D exchange for 90 s at a CD(3)OD pressure of 4 x 10(-7) Torr, indicating the existence of at least two distinct populations. Bradykinin ion populations corresponding to 0-2 and 5-11 deuteriums (i.e., D(0), D(1), D(2), D(5), D(6), D(7), D(8), D(9), D(10), and D(11)) were each monoisotopically selected and fragmented via sustained off-resonance irradiation (SORI) collision-induced dissociation (CID). The D(0)-D(2) ion populations, which correspond to the slower exchanging population, consistently require lower SORI amplitude to achieve a similar precursor ion survival yield as the faster-reacting (D(5)-D(11)) populations. These results demonstrate that conformation/protonation motif has an effect on fragmentation efficiency for bradykinin. Also, the partitioning of the deuterium atoms into fragment ions suggests that the C-terminal arginine residue exchanges more rapidly than the N-terminal arginine. Total deuterium incorporation in the b(1)/y(8) and b(2)/y(7) ion pairs matches very closely the theoretical values for all ion populations studied, indicating that the ions of a complementary pair are likely formed during the same fragmentation event, or that no scrambling occurs upon SORI. Deuterium incorporation into the y(1)/a(8) pseudo-ion pair does not closely match the expected theoretical values. The other peptide, doubly-protonated RVYIFPF, has a trimodal distribution of deuterium incorporation upon H/D exchange with CD(3)OD at a pressure of 1 x 10(-7) Torr for 600 s, indicating at least three distinct ion populations. After 90 s of H/D exchange where at least two distinct populations are detected, the D(0)-D(7) ion populations were monoisotopically selected and fragmented via SORI-CID over a range of SORI amplitudes. The precursor ion survival yield as a function of SORI amplitude falls into two distinct behaviors corresponding to slower- and faster-reacting ion populations. The slower-reacting population requires larger SORI amplitudes to achieve the same precursor ion survival yield as the faster exchanging population. Total deuterium incorporation into the y(2)/b(5) ion pairs matches closely the theoretical values over all ion populations and SORI amplitudes studied. This result indicates the y(2) and b(5) ions are likely formed by the same mechanism over the SORI amplitudes studied.  相似文献   

8.
In this paper a novel workflow-based data acquisition and control system for Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is presented that facilitates a fast on-the-fly decision-making process for a wide variety of data-dependent experiments. Several new workflow implementations demonstrate the flexibility and benefit of this approach for rapid dynamic experimental design on a chromatographic timescale. The different sequence, evaluation, decision and monitoring modules are described using a selected set of examples. During a tandem liquid chromatography (LC)/FTICR-MS experiment the system is used to dynamically switch between various dissociation techniques such as electron capture dissociation (ECD) and sustained off-resonance irradiation (SORI) depending on the charge state of a tryptic peptide peak. The use of this workflow-based system for imaging FTICR-MS using a desorption electrospray ionization (DESI) source demonstrates the possibility of external control of the workflow by feedback from an imaging sample stage.  相似文献   

9.
10.
The electronic properties of the high spin mononuclear MnII complexes [Mn(tpa)(NCS)2] (1) (tpa=tris-2-picolylamine), [Mn(tBu3-terpy)2](PF6)2 (2) (tBu3-terpy=4,4',4'-tri-tert-butyl-2,2':6',2'-terpyridine) and [Mn(terpy)2](I)2 (3) (terpy=2,2':6',2'-terpyridine) with an N6 coordination sphere have been determined by multifrequency EPR spectroscopy. The X-ray structures of 1.CH3CN and 2.C4H10 O.0.5 C2H5OH.0.5 CH3OH reveal that the MnII ion lies at the center of a distorted octahedron. The D-values of 1-3 all fall in the narrow range of 0.041 to 0.105 cm(-1). The comparison of the results reported here and those found in the literature is consistent with the following observation: the D value is sensitive to the coordination number (6 or 5) of the MnII ion as long as the coordination sphere involves only nitrogen and/or oxygen based ligands. This magneto-structural correlation has been analyzed in this work though DFT model calculations. The zero-field splitting (zfs) parameters of 1-3 have been calculated and are in reasonable agreement with the experimental values. Hypothetical simplified models [Mn(NH3)x(OH2)y]2+ (x+y=5 or 6 and [Mn(NH3)5X]+ (X=OH, Cl)) have been constructed to investigate the origin of the zfs. This investigation reveals i) that D is sensitive to the coordination number (5 or 6) of the MnII ion, ii) for the five coordinate systems the major contribution to D is the spin-orbit coupling part, iii) for the six coordinate systems the major contribution to D is the spin-spin interaction and iv) the deprotonation of a water ligand leads to an increase of D, consistent with the relative ligand fields of OH(-) versus H2O.  相似文献   

11.
Ultra-short columns for low-pressure ion chromatography.   总被引:3,自引:0,他引:3  
Since the development of low-pressure ion chromatography (LPIC), many inorganic cations and anions as well as organic acids could be analyzed at a low-pressure of 1.96 x 10(5)-2.94 x 10(5) Pa. And the ultra-short columns took the place of the common long chromatographic columns. Furthermore, the ultra-short columns of LPIC not only reduced the system pressure appreciably, but also achieved high sensitivity and precision. In order to assess the characteristics of the super-short columns, much analysis, i.e., the analysis of alkali metals, alkaline earth metals, transition-metals, rare-earth elements, inorganic anions and organic acids as well as the common amino acids, were conducted. Moreover, excellent results were obtained from the LPIC columns.  相似文献   

12.
Electron capture dissociation (ECD) of polypeptide cations was obtained with pencil and hollow electron beams for both sidekick and gas-assisted dynamic ion trapping (GADT) using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with an electrostatic ion transfer line. Increasing the number of trapped ions by multiple ICR trap loads using GADT improved the ECD sensitivity in comparison with sidekick ion trapping and ECD efficiency in comparison with single ion trap load by GADT. Furthermore, enhanced sensitivity made it possible to observe ECD in a wide range of electron energies (0-50 eV). The degree, rate and fragmentation characteristics of ECD FTICR-MS were investigated as functions of electron energy, electron irradiation time, electron flux and ion trapping parameters for this broad energy range. The results obtained show that the rate of ECD is higher for more energetic (>1 eV) electrons. Long electron irradiation time with energetic electrons reduces average fragment ion mass and decreases efficiency of formation of c- and z-type ions. The obtained dependencies suggest that the average fragment ion mass and the ECD efficiency are functions of the total fluence of the electron beam (electron energy multiplied by irradiation time). The measured electron energy distributions in low-energy ECD and hot ECD regimes are about 1 eV at full width half maximum in employed experimental configurations.  相似文献   

13.
In two-dimensional Fourier transform ion cyclotron resonance mass spectrometry (2D FTICR-MS), scintillation noise, caused mostly by fluctuations in the number of ions in the ICR cell, is the leading cause for errors in spectrum interpretation. In this study, we adapted an algorithm based on singular value decomposition and first introduced by Cadzow et al. (IEE Proceedings Pt. F 1987, 134, 69) to 2D FTICR-MS and we measured its performance in terms of noise reduction without losing signal information in the 2D mass spectrum.  相似文献   

14.
We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1-5% deviation in uncorrected elution times), repeatability (<20% deviation in detected abundances for more abundant peptides from the same aliquot analyzed a few weeks apart), and robustness (high-throughput operation for 5 months without significant downtime). When combined with modulated-ion-energy gated trapping, the dynamic calibration of FTICR mass spectra provided decreased mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations over a dynamic range of peptide peak intensities for each spectrum of 10(3), and >10(5) for peptide abundances in the overall separation.  相似文献   

15.
A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be used for at least 3 months without any considerable divergence in the potentials. The proposed sensor revealed very good selectivities for I3- over a variety of other anions. It was used as an indicator electrode in the potentiometric titration of triiodide ions and in an indirect potentiometric determination of clotrimazole in pharmaceutical preparations.  相似文献   

16.
A continuous preconcentration system for nitrate ions was developed using cation exchange tubing made from Nafion perfluorosulfonic acid membrane. This method is based on ion exclusion effects and reverse osmosis phenomena. The system was evaluated by connecting it to an ion chromatograph. The concentration ratios could be increased by raising the pressures between the two sides of the cation exchange tubing. Twenty-fold concentration of nitrate ion was achieved when the pump pressure was 20 x 10(5) Pa. The relative standard deviations of the preconcentration ratio at four different pump pressures, 5, 10, 15 and 20 x 10(5) Pa were 1.2-2.8% (n = 5).  相似文献   

17.
The trapping and detection parameters employed with a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer that is interfaced to a high magnetic field electrospray ionization (ES11 source are presented. ES1 occurs at atmospheric pressure in a 1.5-T field, and FTICR detection occurs 25 cm away at 3.0 T in either one of two cells separated by a conductance limit and maintained at pressure differentials of 5 × 105 and 2 × 107 torr, respectively. The continuous electrospray ion current traversing the high- and low-pressure cells is 350 and 100 pA, respectively. Retarding grid studies at the high-pressure cell indicate electrospray ion kinetic energies are controllable from less than an electronvolt to more than 10 eV. These kinetic energies are a function of desolvating capillary-skimmer assembly distance and the skimmer potential. Efficient accumulation of injected ions is accomplished only when the trap-plate potential matches the ion kinetic energy. If this condition is satisfied, the trapped ion cell fills to the ion space charge limit within a few hundred milliseconds. It is concluded that even at the high pressures used, the primary trapping mechanism cannot be solely collision dependent because the rate of ion accumulation is independent of background pressure. However, optimized FTICR excitation conditions for peptides and proteins in the mass range from 103 to more than 106 kDa are found to vary strongly with pressure; this is attributed to large mass- and charge-dependent differences in ion-molecule collision frequency.  相似文献   

18.
Technological advancements including an open-cylindrical Penning trap with capacitively coupled ICR cell, selective ion accumulation with a resolving quadrupole, and a voltage gradient used during ion extraction from an octopole ion trap, have individually improved dynamic range and sensitivity in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS). Documented here is a new instrument utilizing these technologies toward the robust detection and fragmentation of biomolecules >10 kDa. Up to 55-fold enhancement in ion population by selective ion accumulation combined with 10- to 20- fold signal-to-noise improvement by application of a DC voltage gradient to an accumulation octopole during the ion transfer event offers improved signal-to-noise (or speed) of MS/MS experiments, for proteins from Methanococcus jannaschii and Saccharomyces cerevisiae whole cell lysates. After external quadrupole filtering with a 40 m/z window, three proteins were fragmented (and identified) in parallel from the database of Methanococcus jannaschii. Electron capture dissociation (ECD) of an intact yeast protein provides extensive sequence information resulting in a high degree of localization for an N-terminal acetylation. Hybrid fragmentation, infrared multiphoton dissociation (IRMPD) followed by low energy electrons (ECD), with the electron source located laterally off the z-axis and external to the magnet bore, presents a strategy for identification of proteins by means of the sequence tag approach. Automated implementation of diverse MS(n) approaches in a Q-FTMS instrument promises to help realize "top-down" proteomics in the future.  相似文献   

19.
To improve the analytical usefulness of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), an extensive survey of various methods for quantitation of peak magnitudes has been undertaken using a series of simulated transient response signals with varying signal-to-noise ratio. Both peak height (five methods) and peak area (four methods) were explored for a range of conditions to determine the optimum methodology for quantitation. Variables included dataset size, apodization function, damping constant, and zero filling. Based on the results obtained, recommended procedures for optimal quantitation include: apodization using a function appropriate for the peak height ratios observed in the spectrum (i.e., Hanning for ratios of about 1:10, three-term Blackman-Harris for ratios of ~1:100, or Kaiser-Bessel for ratios of ~1:1000); zero filling until the peaks of interest are represented by 10–15 points (generally obtained with one order of zero filling); and use of the polynomial y=(ax 2+bx+c) n and the three data points of highest intensity of the peak to locate the peak maximum, Y max=(?b 2/4a+c) n . In this peak fitting procedure, which we have termed the “Comisarow method,” n is 5.5, 9.5, and 12.5 for the Hanning, three-term Blackman-Harris, and Kaiser-Bessel apodization functions, respectively. Accuracy of quantitation using an optimal peak height determination is about equal to that for peak area measurements. These recommendations were found to be valid when tested with real FTICR-MS spectra of xenon isotopes.  相似文献   

20.
Undesired fragmentation of electrospray generated ions in an rf multipole traps can be problematic in many applications. Of special interest here is ion dissociation in a 2-D quadrupole ion trap external to a Fourier transform ion cyclotron resonance mass spectrometer (FTICR MS) used in proteomic studies. In this work, we identified the experimental parameters that determine the efficiency of ion fragmentation. We have found that under the pressure conditions used in this study there is a specific combination of the radial and axial potential well depths that determines the fragmentation threshold. This combination of rf and dc fields appears to be universal for ions of different mass-to-charge ratios, molecular weights, and charge states. Such universality allows the fragmentation efficiency of the trapped ions in the course of capillary liquid chromatography (LC) separation studied to be controlled and can increase the useful duty cycle and dynamic range of a FTICR mass spectrometer equipped with an external rf only 2-D quadrupole ion trap.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号