1.
张续  邱天  付慧  杨艳伟  赵峰  林少彬  胡小键 《色谱》2018,36(9):895-903
建立了人尿中9种邻苯二甲酸酯(PAE)代谢物的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)测定方法。2 mL尿液样本酶解2 h后,经强阴离子固相萃取净化处理;选用Waters ACQUITY UPLC BEH Phenyl色谱柱(100 mm×2.1 mm,1.7 μ m),以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水溶液为流动相进行梯度洗脱;在负离子电喷雾多反应监测模式(MRM)下测定9种PAE代谢物含量。8种PAE代谢物在0.39~200 μ g/L范围内、1种PAE代谢物在1.17~600 μ g/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.06~0.85 μ g/L,定量限为0.20~2.80 μ g/L。3个加标水平的加标回收率为84.1%~122%,精密度为4.5%~14.3%;日内精密度不高于9.3%,日间精密度不高于10.1%;基质效应和稳定性符合分析要求。应用该方法测定50份人尿液样本,邻苯二甲酸单环已酯(MCHP)和邻苯二甲酸单苄酯(MBZP)的检出率分别为0和44.0%,其余7种PAE代谢物的检出率为100%。该方法操作简单、定量准确、稳定性好,适用于人尿中9种PAE代谢物的定量分析。  相似文献   

2.
A novel, simple, rapid, and accurate method is reported for the determination of 4-hydroxyphenyllactic acid in human urine by high-performance anion-exchange chromatography with fluorescence detection and magnetic solid-phase extraction. The separation and pretreatment conditions for urine were optimized. The isolation of 4-hydroxyphenyllactic acid was performed with isocratic elution with 4?mmol?L?1 sodium hydroxide at 0.45?mL min?1. Fluorescence detection was performed at an excitation wavelength of 277?nm and an emission wavelength of 340?nm. Under the optimized conditions, the linear dynamic range and the limit of detection for 4-hydroxyphenyllactic acid were 0.05–10 and 0.020?mg?L?1, respectively. The recovery for the analyte was from 86.5 to 105.5%, with relative standard derivations less than 4.12%. The method was used for the determination of 4-hydroxyphenyllactic acid in human urine. Statistically significant differences in the 4-hydroxyphenyllactic acid concentration in urine were obtained between healthy control and individuals with breast cancer.  相似文献   

3.
A robust analytical method is required for the determination of low-molecular weight organic acids, which are potential causes of refinery and internal combustion engine corrosion. The ion chromatographic method developed in this study allows the determination of acetic acid and formic acid in diesel oil mixtures with a motor oil volume fraction of up to 10%. The hydrophobic matrix is automatically removed in-line through a matrix elution step with organic solvent and nonaqueous anion-exchange analyte extraction. Acetic acid and formic acid, as the smallest and most acidic aliphatic naphthenic acids, were determined. Gradient anion-exchange chromatography on high-capacity columns in combination with suppressed conductivity detection allowed their selective and sensitive determination. Typical recovery values were from 82 to 107% for each acid in the matrices evaluated with reproducibility less than 5% for acid fortified samples.  相似文献   

4.
冯蕾  鄢爱平  陈林  万益群 《色谱》2010,28(4):408-412
建立了固相萃取-高效阴离子交换色谱-积分脉冲安培法(SPE-HPAEC-IPAD)测定人体尿液中异黄蝶呤的分析方法。尿液经ENVI-18与732型阳离子交换柱串联萃取后,除去了大量干扰物质。采用IonPac AS21分析柱(250 mm×2 mm),以0.025 mol/L NaOH溶液为淋洗液,流速为0.40 mL/min,在优化的安培检测波形条件下,异黄蝶呤的质量浓度在0.005~0.200 mg/L范围内与峰面积呈良好的线性关系,相关系数为0.998 4,检出限为0.003 mg/L。健康人及癌症病人尿液在2 mg/L和5 mg/L两个添加水平的平均回收率在95.4%~96.8%之间,相对标准偏差小于5%。此方法环保、快速、准确,可用于健康人与癌症病人尿液中异黄蝶呤的测定。  相似文献   

5.
Pulgarin JA  Molina AA  López PF 《Talanta》1996,43(3):431-438
A new method for the determination of nalidixic acid in urine is proposed for concentrations between 25 and 1000 ng ml(-1) by means of matrix isopotential synchronous fluorescence spectrometry. This new technique is useful for the determination of compounds in samples with unknown background fluorescence, such as nalidixic acid in urine, without the need for tedious preseparation. The method was performed in ethanol/water medium (80% v/v), at an apparent pH of 2.9 provided by adding sodium monochloracetate/monochloroacetic acid buffer solution. The method was successfully applied to the determination of nalidixic acid in urine. Better sensitivity and reproducibility are achieved in these matrices than with the fluorimetric methods described in the literature.  相似文献   

6.
The simultaneous determination of salicylic acid and diflunisal in human serum has been accomplished by synchronous fluorimetry, in combination with partial least-squares multivariate calibration. The total luminescence information of the analytes has been used to optimize the spectral data set for the calibration, by analysis of the three-dimensional excitation-emission matrices. The synchronous spectrum, maintaining a constant difference of Deltalambda = 128 nm between the emission and excitation wavelengths, has been selected as optimum to perform the determination. The method is based on the fluorescence of these compounds in chloroform containing 1% (v/v) acetic acid. Serum samples are treated with trichloroacetic acid to remove the proteins, and both analytes are extracted into chloroform-1% (v/v) acetic acid prior to the determination. For concentrations ranging from 60-240 mug ml(-1) of each drug, analytical recoveries range from 96% to 103% for salicylic acid and from 97% to 105% for diflunisal.  相似文献   

7.
设计了一个HPLC在线电生Mn(Ⅲ)化学发光检测器, 实现在线电化学反应, 从而产生反应活性很高的初生态氧化剂Mn(Ⅲ), 并与色谱柱后CP混合产生化学发光. 同时还能够根据需要调节电极反应和发光反应两者的介质, 满足柱后发光反应的最佳环境. 在优化流动相和化学发光检测条件的基础上, 将该检测器应用于人体血清和尿液中CP的测定.  相似文献   

8.
张续  韩林学  邱天  胡小键  朱英  杨艳伟 《色谱》2023,41(3):224-232
基于96孔固相萃取-超高效液相色谱-串联质谱法,建立了人尿中2种苯氧乙酸除草剂、2种有机磷农药代谢物和4种拟除虫菊酯农药代谢物的测定方法。通过对液相色谱条件、质谱条件和样品前处理过程的系统优化,实现了在16 min内对8种目标分析物的分析测定。具体方法:1 mL尿液经β-葡萄糖醛酸酶酶解过夜,Oasis HLB 96孔固相萃取进行目标分析物的提取净化,甲醇洗脱;以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水作为流动相,Acquity BEH C_(18)作为分析柱进行色谱分离;负离子电喷雾(ESI-)多反应监测(MRM)模式下检测目标化合物,同位素内标法定量。2,4-二氯苯氧乙酸(2,4-D)、2,4,5-三氯苯氧乙酸(2,4,5-T)2种苯氧乙酸除草剂和3-苯氧基苯甲酸(3-PBA)、4-氟-3-苯氧基苯甲酸(4F-3PBA)、反式二氯乙烯基二甲基环丙烷羧酸(trans-DCCA)3种拟除虫菊酯农药代谢物在0.1~100μg/L内、对硝基苯酚(PNP)、3,5,6-三氯-2-吡啶酚(TCPY)2种有机磷农药代谢物、顺式二氯乙烯基二甲基环丙烷羧酸(cis-DCCA)1种拟除虫菊酯代谢物在0.2~100μg/L内线性关系良好,相关系数均大于0.9993;方法检出限为0.02~0.07μg/L,方法定量限为0.08~0.2μg/L;低、中、高3个水平下的加标回收率为91.1%~110.5%,日内精密度为2.9%~7.8%,日间精密度为6.2%~10%。应用该方法测定了214份尿液样本。结果显示除2,4,5-T外,其余7种目标分析物均有检出。TCPY、PNP、3-PBA、4F-3PBA、trans-DCCA、cis-DCCA、2,4-D的检出率为2.8%~99.1%。检出浓度(中位值)由高到低分别是2.0μg/L(TCPY)、1.8μg/L(PNP)、0.99μg/L(trans-DCCA)、0.81μg/L(3-PBA)、0.44μg/L(cis-DCCA)、0.35μg/L(2,4-D)和未检出(4F-3PBA)。该方法操作简便,定量准确,灵敏度高,每批次可完成96个样品测定,适用于人尿中多种农药及农药代谢物的批量分析测定。  相似文献   

9.
Electrophoretic separation of tryptophan enantiomers in biological samples.   总被引:1,自引:0,他引:1  
S Zhao  Y M Liu 《Electrophoresis》2001,22(13):2769-2774
A method for the determination of D- and L-tryptophan (Trp) in biological samples is described. The amino acid enantiomers were precolumn-derivatized with a fluorescence tagging reagent, naphthalene-2,3-dialdehyde (NDA). In the presence of hydroxypropyl-gamma-cyclodextrin (HP-gamma-CD) as the chiral selector, NDA-tagged Trp enantiomers were well resolved by micellar electrokinetic chromatography (MEKC). Using laser induced fluorescence (LIF) detection, a detection limit of 3.3 x 10(-8) M Trp was obtained. The method was applied to the determination of Trp enantiomers in biological samples including human urine and cerebrospinal fluid (CSF), rat brain tissue, and Aplysia ganglia. No interference from other amino acids or the endogenous compounds in the sample matrices was observed. D-Trp was found at the sub-microM level in human urine samples collected from several healthy subjects. Further, the determination of DL-Trp residues in small quantities (10 microg) of peptides after acid hydrolysis is demonstrated.  相似文献   

10.
Electromembrane extraction was used for simultaneous sample cleanup and preconcentration of lithium from untreated human body fluids. The sample of a body fluid was diluted 100 times with 0.5 mM Tris solution and lithium was extracted by electromigration through a supported liquid membrane composed of 1-octanol into 100 mM acetic acid acceptor solution. Matrix compounds, such as proteins, red blood cells, and other high-molecular-weight compounds were efficiently retained on the supported liquid membrane. The liquid membrane was anchored in pores of a short segment of a polypropylene hollow fiber, which represented a low cost, single use, disposable extraction unit and was discarded after each use. Acceptor solutions were analyzed using capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4) D) and baseline separation of lithium was achieved in a background electrolyte solution consisting of 18 mM L-histidine and 40 mM acetic acid at pH 4.6. Repeatability of the electromembrane extraction-CE-C(4) D method was evaluated for the determination of lithium in standard solutions and real samples and was better than 0.6 and 8.2% for migration times and peak areas, respectively. The concentration limit of detection of 9 nM was achieved. The developed method was applied to the determination of lithium in urine, blood serum, blood plasma, and whole blood at both endogenous and therapeutic concentration levels.  相似文献   

11.
A liquid chromatographic method for highly sensitive and selective fluorometric determination of polyamines (putrescine, cadaverine, spermidine and spermine) in human urine is described. This method is based on an intramolecular excimer-forming fluorescence derivatization with a pyrene reagent, 4-(1-pyrene)butanoyl chloride (PBC), followed by reversed-phase liquid chromatography. The method offers higher sensitivity for determination of spermidine and spermine than previously reported method utilizing 4-(1-pyrene)butyric acid N-hydroxysuccinimide ester as a derivatization reagent. Samples containing free polyamines in diluted human urine were directly derivatized with PBC and separated on an octyl column. The derivatives were detected at excitation 345 and emission 475 nm wavelengths. For determination of total polyamine content, the conjugated polyamines were first hydrolyzed in 4 M HCl. The detection limits (signal-to-noise ratio = 3) for polyamines in urine were 1.1-3.4 pmol/mL. At optimized derivatization and chromatographic conditions, interferences such as biogenic monoamines gave no peaks or the peaks did not interfere with the peaks of polyamine derivatives. In conclusion, the present derivatization method allows direct determination of polyamines in human urine samples without the need for sample clean-up procedures.  相似文献   

12.
CE with capacitively coupled contactless conductivity detection (C(4)D) was used to determine waste products of the nitrogen metabolism (ammonia and creatinine) and of biogenic inorganic cations in samples of human urine. The CE separation was performed in two BGEs, consisting of 2 M acetic acid + 1.5 mM crown ether 18-crown-6 (BGE I) and 2 M acetic acid + 2% w/v PEG (BGE II). Only BGE II permitted complete separation of all the analytes in a model sample and in real urine samples. The LOD values for the optimized procedure ranged from 0.8 microM for Ca(2+) and Mg(2+) to 2.9 microM for NH(4)(+) (in terms of mass concentration units, from 7 microg/L for Li(+) to 102 microg/L for creatinine). These values are adequate for determination of NH(4)(+), creatinine, Na(+), K(+), Ca(2+) and Mg(2+) in real urine samples.  相似文献   

13.
A novel chemiluminescence (CL) flow sensor for the determination of uric acid in human urine and serum has been developed by using controlled-reagent-release technology. The reagents involved in the chemiluminescence (CL) reaction, luminol and periodate, are immobilized on anion-exchange resin packed in a column. After injection of water, chemiluminescence generated by released luminol and periodate in alkaline media is inhibited in presence of uric acid. By measuring the decreased chemiluminescence (CL) intensity the uric acid is sensed. The decreased response is linear in the 5.0-500.0 ng mL(-1) range, with a detection limit of 1.8 ng mL(-1). The flow sensor showed remarkable operational stability and could be easily reused for over 80 h with sampling frequency of 100 h(-1). The proposed sensor was applied to the determination of uric acid in human urine and serum, and monitoring metabolic uric acid in human urine with RSD less than 3.0%.  相似文献   

14.
A simple and highly sensitive method for the determination of free and total (free + conjugated) catecholamines (norepinephrine, epinephrine and dopamine) in human urine is described which employs HPLC with fluorescence detection. Conjugated catecholamines (sulfate form) are hydrolyzed by a sulfatase-mediated reaction to the corresponding free amines. After cation exchange chromatography on a Toyopak IC-SP S cartridge, catecholamines and isoproterenol (internal standard) in urine samples were converted into the corresponding fluorescent compounds by reaction with 1,2-diphenylethylenediamine. These compounds were separated within 8 min on a reversed phase column with isocratic elution using a mixture of water, methanol and acetonitrile containing a Tris-hydrochloric acid buffer (pH 7.0). The detection limit for each catecholamine is ca 2 fmol per 100 microL injection volume.  相似文献   

15.
An automated method based on the on-line coupling of anion-exchange solid-phase extraction (SPE) and cation-exchange liquid chromatography followed by post-column derivatization and fluorescence detection has been developed for the trace level determination of glyphosate and its primary conversion product aminomethyl phosphonic acid (AMPA) in water. PRP-X100 poly(styrene-divinylbenzene)-trimethylammonium anion-exchange cartridges (20 x 2 mm, 10 microm) were selected for the SPE of glyphosate and AMPA. The ionic compounds present in the samples strongly influenced the extraction of both analytes; however, when an on-line ion-exchange clean-up step was introduced before sample SPE, the problem was largely solved. By processing 100-ml samples detection limits better than 0.02 microg/l for glyphosate and 0.1 microg/l for AMPA were achieved in river water. Both analytes were unstable in solution and the approach of storing samples on the PRP-X100 SPE cartridges was evaluated for a period of 1 month under three different storage conditions (deep freeze, refrigeration and 20 degrees C).  相似文献   

16.
A practical biosensor system has been developed for the determination of urinary glucose using a flow-injection analysis (FIA) amperometric detector and ion-exchange chromatography. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immobilized enzyme column. On the basis of its negative charge at pH 5.5, endogenous urate in urine samples was effectively retained by an upstream anion-exchange resin column. The biosensor system possessed a sensitivity of 160 ±2.4 RU μM-1 (RU or relative unit is defined as 2.86 μV at the detection output) for glucose with a minimum detection level of 10 μM. When applied for the determination of urinary glucose, the result obtained compared very well with that of the widely accepted hexokinase assay. The immobilized glucose oxidase could be reused for more than 1000 repeated analyses without losing its original activity. The reuse of the acetate anion-exchange column before replacement would be about 25–30 analyses. Acetaminophen and ascorbic acid were also effectively adsorbed by the acetate anion exchanger. The introduction of this type of anion exchanger thus greatly improved the selectivity of the FIA biosensor system and fostered its applicability for the determination of glucose in urine samples.  相似文献   

17.
A simple and reliable method was established for simultaneous determination of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid in human urine by high‐performance liquid chromatography with fluorescence detection. Solid‐phase extraction was used to eliminate the interferences in urine. The separation of three analytes was achieved using a C18 column and a mobile phase formed by a 95:5 v/v mixture of 50 mmol/L ammonium acetate buffer at pH 6.8 that contained 5 mmol/L tetrabutyl ammonium bromide and acetonitrile. Under the optimized conditions, the detection limits of 4‐hydroxyphenyl acetic acid, 4‐hydroxyphenyl lactic acid, and 3,4‐hydroxyphenyl propionic acid were 4.8 × 10−3, 8.80 × 10−3, and 9.00 × 10−3 mg/L, respectively, and the recoveries were in the range of 85.0–120.0% with relative standard deviations of 1.5–3.1%. This method was used to analyze urine samples from breast cancer patients, healthy people and post‐surgery breast cancer patients. Significant differences in urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid could be found between the breast cancer patients group and other two groups. No effect of age and sex was observed on the urinary levels of 4‐hydroxyphenyl acetic acid and 4‐hydroxyphenyl lactic acid. This method might be helpful for cancer biomarkers discovery in urine.  相似文献   

18.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

19.
We investigated the potential of CE coupled to electrospray MS (CE-ESI-MS) in metabolite profiling of human urine without any sample prefractionation step. A heterogeneous mixture of biologically relevant compounds covering a broad range of physicochemical properties was used to optimize separation conditions in fused-silica capillaries. A running electrolyte containing 50 mM of acetic acid and 50 mM of formic acid at pH 2.5 was used for the CE separations. A sheath-flow electrospray interface was employed for CE-ESI-MS analysis. Sheath liquids containing 80:20 v/v methanol/water with 0.1% v/v of acetic acid or 60:40 v/v isopropanol/water with 0.5% v/v of ammonia were selected for optimum detection in positive and negative ESI modes, respectively. Reproducibility and sensitivity were studied, and strategies for identification of the separated urinary compounds are suggested. We report major advantages and disadvantages of CE-ESI-MS for metabolite profiling of human body fluids. This work may be regarded as a first step in the use of CE-ESI-MS for reliable differential analysis of body fluids from healthy and diseased individuals.  相似文献   

20.
A new micellar electrokinetic chromatographic method has been developed to analyse human urine samples containing a combination of a drug used for the treatment of breast cancer (letrozole), an antidepressant (citalopram) and their main metabolites. Best results were obtained by using 15 mM borate buffer (pH 9.2) containing 20 mM sodium dodecyl sulphate and 12% (v/v) 2-propanol as the background electrolyte. The separation was performed through a fused silica capillary at 40 degrees C with the application of 6s (3.45 kPa) of hydrodynamic injection and 30 kV of separation voltage. Detection wavelength was 240 nm. Under these conditions, the migration times for all the studied compounds were ranged between 3.0 and 8.0 min. Linearity ranges were determined as 0.4-5.0 microg/mL for all the compounds. Detection limits between 12.5 and 25 ng/mL were determined in urine samples. According to the validation study, the developed method has been proven to be accurate, precise, sensitive, specific, rugged and robust. This method has been used to determine letrozole, citalopram and their metabolites in human urine at clinical levels. Prior to determination, the samples are purified and enriched by means of an extraction-preconcentration step with a preconditioned C(18) cartridge and by eluting the compounds with methanol. The developed method was applied to the determination of these analytes in three urine samples from patients undergoing treatment with letrozole or citalopram.  相似文献   