首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Summary The formation of complexes amongst vanadium, o-hydroxyhydroquinonephthalein (Qnph), or/and chlorpromazine hydrochloride (CP · HCl), as a phenothiazine drug, in non-ionic surfactant micellar media was fluorometrically investigated in weakly acidic media. Fluorometric methods for the determination of vanadium and CP · HCl were respectively established by measuring the difference of relative fluorescence intensities (F) between Qnph and Qnph-vanadium solutions, andF between Qnph-vanadyl and Qnph-vanadyl-CP · HCl solutions at an emission wavelength of 540 nm with excitation at 400 nm in the presence of polyvinyl alcohol (PVA) micelles. The calibration graphs were linear in the ranges of 0–0.5 vanadium and 0–220 g CP · HCl per 10 ml of aqueous solution. The relative standard deviations (5 replicates) were 2.5% for 0.2 g vanadium and 1.3% for 100 g CP · HCl per 10 ml of aqueous solution, respectively. The applications to assays of vanadium in water and CP · HCl preparations were investigated, and the results were relatively good.
Fluorescenzreaktion von o-Hydroxyhydrochinonphthalein und Vanadium in micellaren Medien und deren Anwendung

Application of xanthene derivatives in analytical chemistry. Part LXXIII. Part LXXII see ref. [1]  相似文献   

2.
A method for the simultaneous spectrophotometric determination of cobalt, nickel and iron based on the formation of their complexes with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is proposed. The absorption curves of these complexes overlap severely in the scanning range 390–510 nm. The analyte concentrations are calculated by a least squares fit of the pure spectra to the mixture spectra, which therefore makes the simultaneous determination of these metallic ions possible without tedious pretreatment. The detection limits afforded by the proposed method range from 0.05 g/ml for Fe and Ni to 0.1 g/ml for Co. Root-mean-squared errors of prediction of 0.085 g/ml for Co, 0.048 g/ml for Ni and 0.1172 g/ml for Fe were obtained using the wavelength range 400–510 nm and 0.147 g/ml for Co, 0.107 g/ml for Ni and 0.127 g/ml for Fe using the wavelength range 420–434 nm. The effect of interferences is studied and the proposed method is applied to analysis for the above elements in synthetic samples and real samples, such as biological materials and alloys.  相似文献   

3.
    
Zusammenfassung Zur Abtrennung des Vanadiums von Begleitelementen, hauptsächlich Fe, Cu, Pb, Zn, wird eine Extraktion des -Benzoinoximkomplexes in Chloroformlösung durchgeführt. Zur Bestimmung wird mit NaOH-Lösung in wäßrige Phase zurückextrahiert und die Absorption des mit PAR gebildeten Komplexes bei 545 nm gemessen. Die Eichkurve verläuft von 0,05–0,8 g V/ml linear. 50 g V konnten mit einer Abweichung von höchstens 5 g wiedergefunden werden.
Separation of vanadium by extraction and re-extraction of the benzoin -oxime complex and subsequent photometric determination with PAR
For the separation of vanadium from accompanying elements, mainly Fe, Cu, Pb, Zn, an extraction of the benzoin -oxime complex in chloroform solution is carried out. For the subsequent determination re-extraction into aqueous phase by NaOH solution is employed and the absorption of the complex formed with PAR is measured at 545 nm. The calibration curve is linear from 0.05 to 0.8 g V/ml. 50 g of V could be recovered with a maximum deviation of 5 g.
  相似文献   

4.
Summary A procedure is described suitable for determining iron and gallium down to the levels present in 99.999% pure aluminium. Copper, cobalt, manganese, and lanthanum do not interfere. A single determination takes about two hours.The precision of the method is within 0.1g iron at the 2-g iron level and within 0.4g of gallium at the 2-g gallium level per gram of metal.
Zusammenfassung Ein Verfahren zur Bestimmung von Bisen und Gallium in 99,999%igem Aluminium wird beschrieben. Kupfer, Kobalt, Mangan und Lanthan stören nicht. Eine Einzelbestimmung dauert ungefähr 2 Stunden. Die Genauigkeit des Verfahrens beträgt 0,1g Fe und 0,4g Ga bei Anwesenheit von 2g des betreffenden Elementes pro Gramm Metall.

Résumé On décrit un procédé permettant le dosage du fer et du gallium jusqu'aux teneurs présentes dans l'aluminium pur à 99,999%. Le cuivre, le cobalt, le manganèse et le lanthane n'interfèrent pas. Un seul dosage demande environ 2 heures.La précision de la méthode est de 0,1g de fer pour 2g de fer présent et de 0,4g de gallium pour 2g de gallium présent par gramme de métal.
  相似文献   

5.
Zusammenfassung Es wird eine photometrische Bestimmungsmethode beschrieben für Anilin (40–720 g/ml), Monoäthylanilin (90–1650 g/ml) und Diäthylanilin (100–1600 g/ml) mit Natriumchlorit in äthanolisch-wäßrigen Lösungen, sowie für Diäthylanilin (85–1140 g/ml) und Dimethylanilin (30–330 g/ml) neben den primären und sekundären Aminen in essigsaurer Lösung mit demselben Reagens. Das Verfahren liefert gute Ergebnisse.
Summary A photometric procedure is described for the determination of aniline (40–720 g/ml), monoethylaniline (90–1650 g/ml), and diethylaniline (100–1600 g/ml) with sodium chlorite in aqueous ethanolic solutions and of diethylaniline (85–1140 g/ml) and dimethylamline (30 to 330 g/ml) in presence of the primary and secondary amines in acetic acid solution using the same reagent. Good results have been obtained,
  相似文献   

6.
The absorption spectra of 4f electron transitions of the neodymium and erbium complexes with benzoyl-indan-1,3-dione and cetylpyridinium chloride have been studied by conventional and derivative spectrophotometry. The second-derivative spectrum has been used to eliminate the interference of the other lanthanides, and to increase the sensitivity by a further factor of 4–6. Beer's Law is obeyed for 6–29 g/ml Nd and 7–33 g/ml Er. The relative standard deviations evaluated from 10 independent determinations of 5.0 g/ml Nd and Er were 1.1% (Nd) and 1.6% (Er). The detection limits obtained from the sensitivity of the calibration graphs and 3s b, (standard deviation of the blank,n = 11) were 0.63 g/ml Nd and 0.61 g/ml Er. The quantification limits (10s b) were 2.1 g/ml Nd and 2.0 g/ml Er. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

7.
Summary Solochrome Black 6 BN in an acetate buffered medium containing methanol reacts with U(IV) to give a blue complex which permits photometric determination with 5g U/ml to 100g U/ml.In the presence of zinc acetate, uranyl ion also may be spectrophotometrically determined by means of the same dye. From 2g U/ml to 40g U/ml may be determined with a relative error of less than ± 0.05.
Zusammenfassung Es werden zwei Methoden zur spektrophotometrischen Bestimmung von Uran mittels Solochromschwarz 6 BN beschrieben. Dieser Farbstoff bildet mit U(IV) in acetatgepuffertem, methanolhältigem Medium einen blaugefärbten Komplex, der die Bestimmung von 5 bis 100g U/ml erlaubt.Mit demselben Farbstoff lassen sich auch 2 bis 40g U/ml in Lösungen von Uranylchlorid bestimmen.

Résumé Le noir solochrome 6 BN en milieu tampon acétique contenant du méthanol réagit avec U-IV en donnant un complexe bleu qui permet le dosage photométrique de 5 g U/ml à 100 g U/ml.En présence d'acétate de zinc, on peut aussi doser l'ion uranyle par spectrophotométrie avec le même colorant. On peut doser de 2 g U/ml à 40 g U/ml avec une erreur relative inférieure à ± 0,05.
  相似文献   

8.
    
Zusammenfassung 2-Thiobarbitursäure wird zum Nachweis und zur Bestimmung von Fe(III) verwendet. Im Reagensglas kann noch 1 g Fe(III)/ml nachgewiesen werden. Eine größere Empfindlichkeit (0,2 g/ml) wird bei Anwendung eines mit Thiobarbitursäurelösung getränkten Papiers erreicht. Die photometrische Bestimmung ist im Konzentrationsbereich 4–40 g/ml mit einem Fehler von höchstens ±0,5 g möglich.
Summary 2-Thiobarbituric acid is recommended for the detection and determination of trivalent iron. In the test tube 1 g of Fe(III)/ml can be detected, whereas this limit can be reduced to 0.2 g of Fe(III)/ml by use of paper impregnated with the reagent. The photometric determination is possible within the range of 4–40 g of Fe(III)/ml with an error of not more than ±0.5 g.
  相似文献   

9.
Summary A new method for the separation of tetramethyllead (TML) and tetraethyllead (TEL) was developed using high-performance liquid chromatography. The electrochemical detection was examined with different electrodes. Amperometric and pulse-amperometric techniques were investigated and the optimal working potential for each electrode was determined. Linearity for the glassy carbon electrode was observed between 350 ng and 30 g; the detection limit is 310 ng (TML) resp. 340 ng (TEL). In case of the mercury gold electrode the linearity range was 300 g–3 g and the detection limit 1.5 m (TML) resp. 1.7 g (TEL).  相似文献   

10.
The microwave spectrum of 1,3dioxolane (C3H6O2) in the ground and first three excited states of hindered pseudorotation was studied. The transitions corresponding to the b, c, and a components of the dipole moment were identified. The spectrum was analyzed using numerical diagonalization of the effective rotational Hamiltonian for four interacting states of hindered pseudorotation. The rotational constants, centrifugal distortion constants, the constants of interaction between general rotation and hindered pseudorotation, and the distances between the quasidegenerate vibrational levels 01 = 64840.5, 12 = 122231.7 and 23 = 119732.7 MHz are determined. From the Stark effect of microwave transitions, the dipole moment components (in Debye units) in the hinderedpseudorotation states v = 0, 1, 2, and 3 are determined: 0|b|0 = 1|b|1 = 1.22, 2|b|2 = 1.20, 3|b|3 = 1.21, 0|c|1 = 0.77, 2|c3 = 0.66, and 1|a|2 = 0.19.  相似文献   

11.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

12.
Zusammenfassung Es wird vorgeschlagen, den unteren Anwendungsbereich quantitativer Methoden ebenso wie in der qualitativen Mikroanalyse durch die Begriffe Grenzkonzentration und Erfassungsgrenze zu kennzeichnen. Durch die Ableitung dieser Werte nach mathematisch-statistischen Regeln erhalten Grenzkonzentration und Erfassungsgrenze den Charakter objektiver Kennzahlen. Für photometrische und spektralphotometrische Methoden werden Gleichungen zur Berechnung der Grenzkonzentration ing/ml und in Prozent der Probe, sowie der Erfassungsgrenze ing Substanz angegeben. Berechnungsgrundlagen sind die Streuung der Blindwerte, der molare Extinktionskoeffizient oder der Sandellsche Empfindlichkeitsindex und andere analytische Parameter.
Summary It is suggested that the lower application region of quantitative methods, just as in the case of qualitative microanalyses, be characterized by the concepts limiting concentration and detection limit. These values acquire the character of objective coefficients when they are derived in accord with mathematical-statistical laws. Equations for calculating the limiting concentration ing/ml and in % of the sample, as well as the detection limit ing of the material, are given for photometric and spectrophotometric methods. The bases for the calculation are the dispersion of the blank values, the molar extinction coefficient, or the Sandell sensitivity index and other analytical parameters.


Herrn Professor Dr.Hans Lieb aus Anlaß seines 80. Geburtstages gewidmet.  相似文献   

13.
    
Summary 0.05 to 25 g/g of vanadium in iron was determined by inductively coupled plasma atomic emission spectrometry after solvent extraction using N-benzoyl-N-phenylhydroxylamine-chloroform solution. Vanadium extracted in the chloroform phase was finally transferred into perchloric acid solution and sprayed into the ICP. The analytical line and the correction line for variation in spectral intensity were V II 309.311 nm and Y II 371.030 nm, respectively. Standard deviation and detection limit were 0.03 g and 0.1 g.  相似文献   

14.
Summary For the trace determination of sodium alkylbenzenesulphonate (ABS) by HPLC the following conditions were employed: Shimadzu ZORBAX SIL Column (5 m, 4.6 mm i.d. x 150 mm) as stationary phase, 0.2% ammoniaethanol (v/v) as mobile phase, UV detector at 225 nm, injection volume 12 l. The chromatograms of ABS were simple and sharp (detection limit of ABS 0.02 g in 12 l of ethanol). The calibration curves of ABS were linear in a concentration range of 0.03 0.3 g in 12 l of ethanol. In the case of linear sodium dodecylbenzenesulphonate positive errors of 1 4% were caused by non-ionic surfactants or laurylsulphate (6 times excess), 10 50% positive errors were caused by 2 6 times excess of household detergents.Standard water samples containing ABS were treated with a weak base anion-exchange resin, the adsorbed ABS were eluted, and then determined either by HPLC or by the methylene blue spectrophotometric method. Recoveries of ABS in water were about 92 107% by HPLC.
Bestimmung von Spuren Natriumalkylbenzolsulfonat mit Hilfe der HPLC. Anwendung auf Wasser
Zusammenfassung Für die Spurenbestimmung von Natriumalkylbenzolsulfonat (ABS) durch HPLC werden die folgenden Bedingungen empfohlen:Shimadzu ZORBAX SIL (5 m, 4,6 mm x 150 mm) als stationäre Phase, 0,2% Ammoniak/Ethanol als mobile Phase, UV-Detektor bei 225 nm, Injektionsvolumen 12 l. Die erhaltenen Chromatogramme sind einfach und scharf (Nachweisgrenze 0,02 g in 12 ml Ethanol). Die Eichkurven sind im Konzentrationsbereich von 0,03–0,3 g in 12 l Ethanol linear. Im Falle des linearen Natriumdodecylbenzolsulfonats werden bei Anwesenheit von nicht-ionischen oberflächenaktiven Substanzen oder von Laurylsulfat in 6fachem Überschuß positiver Fehler von 1–4% erhalten; bei 2–6fachem Überschuß von Haushaltswaschmitteln ergeben sich positive Fehler von 10–50%.Standard-Wasserproben werden zunächst einer Behandlung mit einem Anionenaustauscher unterzogen, die adsorbierten ABS eluiert und durch HPLC oder nach der Methylenblaumethode analysiert. Wiederfindungsraten liegen bei 92–107%.
  相似文献   

15.
    
Zusammenfassung Die Arbeit beschreibt die photometrische Bestimmung von Vanadium(V) mit-Naphthylamin. Die Bestimmung gelingt in reinen Lösungen zwischen 6 und 640 g V/ml, in Gegenwart gewisser Fremdmetalle (von denen nur Eisen und Molybdän stören) von 30–640 g V/ml. Die verwendeten Reagentien sind billig.
Summary A procedure for the photometric determination of vanadium(V) using -naphthylamine is presented. It can be employed within a concentration range of 6 to 640 g V/ml for pure solutions and of 30 to 640 g V/ml for solutions containing certain foreign ions. Iron and molybdenum interfere and must not be present. All reagents used are quite inexpensive.
  相似文献   

16.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

17.
Zusammenfassung Staub- und Aerosolproben werden im Stickstoffstrom im Temperaturbereich 25–420° C einer temperaturprogrammierten thermischen Desorption unterworfen. Die flüchtigen organischen Komponenten werden mittels FID summarisch als volatile organic carbon (VOC) bestimmt. Die Eichung des Analysators erfolgt durch ein Aliphaten-Standardgemisch. Bei Probemengen von 50–100g Aerosol ist eine Bestimmung des VOC-Gehaltes mit einer Reproduzierbarkeit vons=3,5–7 rel.% möglich. Die Nachweisgrenze der Methode liegt für Aerosolproben bei 0,3g VOC.
Determination of volatile organic components in atmospheric aerosol samples by thermal desorption and FID-detection
Summary Atmospheric dust and aerosol samples are treated in a nitrogen carrier gas stream at the temperature range 25–420° C by temperature programmed desorption. The volatile organic components are detected by FID. Calibration of the analyzer is carried out with a standard mixture of aliphatic hydrocarbons. The result is expressed as volatile organic carbon (VOC). The reproducibility of the method for aerosol samples (sample weight 50–100g) is in the range of 3,5–7% r. s. d. The detection limit of the method is 0,3g VOC.
  相似文献   

18.
Zusammenfassung Ein schnelles und einfaches Mikroverfahren zum Nachweis einiger Heteroatome organischer Verbindungen wurde entwickelt. Nach Aufschluß mit metallischem Kalium werden die entstehenden Ionen mit der Ringofenmethode getrennt und mit empfindlichen Reaktionen nachgewiesen. Nachweisgrenze: 0,5 bis 1g Stickstoff, 1 bis 2g Schwefel, 2 bis 3g Jod, 4 bis 5g Brom, 5 bis 10g Chlor in 0,5 bis 1 mg Einwaage.
Summary A rapid and simple micromethod was developed for the detection of several hetero-elements in organic compounds. After breaking down the sample with metallic potassium, the resulting ions are separated by the ring oven method and detected by means of sensitive reagents. Detection limits: 0.5 to 1g nitrogen, 1 to 2g sulfur, 2 to 3g iodine, 4 to 5g bromine, 5 to 10g chlorine in samples weighing 0.5 to 1 mg.

Résumé On a découvert un procédé à l'échelle micro, simple et rapide, pour rechercher certains hétéroéléments dans les composés organiques. Après mise en solution par le potassium métallique, on sépare les ions formés suivant la méthode du four annulaire et l'on effectue la recherche au moyen de réactions sensibles. Limite de dilution: 0,5 à 1g d'azote, 1 àg de soufre, 2 àg d'iode, 5 à 10g de chlore sur 0,5 à 1 mg de prise d'essai.
  相似文献   

19.
A gas-chromatographic separation procedure with mass-spectrometric detection was developed for the detection of opiates in whole blood and the quantitative determination of morphine and codeine as their propionic esters. The detection limit for morphine and codeine in blood was 0.02 g/mL. The analytical range was 0.05–2.0 g/mL. The maximum intraseries relative errors were 15.6 and 11.2% for concentrations of 0.05 and 1.0 g/mL, respectively. The interseries relative errors were no higher than 8 and 3% for concentrations of 0.05 and 1.0 g/mL, respectively. The procedure is intended for forensic chemical analysis in cases of opiate poisoning.  相似文献   

20.
Two new 1:2 polymeric complexes of copper(II) azide with ethyl isonicotinate (1) and methyl isonicotinate (2) have been synthesized and characterized by spectroscopic and crystallographic methods. The polymeric structure of complex (1) features six coordinated copper centers, a pair of trans-coordinated ligand molecules, and asymmetric 2-1,1 and 2-1,3-azido bridges resulting in a 1D chain structure. In complex (2), each copper atom which is located at an inversion center, is coordinated to a pair of trans ligand molecules, to the nitrogen atom of two -1,1-azido ligand and to an oxygen atom of a bridging (-O,O) nitrogen group. The i.r., electronic and e.s.r. spectra of the complexes are reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号