首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

2.
Flupentixol and an internal standard, loperamide were extracted from human plasma by liquid–liquid extraction and analyzed on a Thermo Hypersil HyPURITY C18 column, with 10 mM ammonium acetate–acetonitrile–methanol (26:62:12, v/v/v) as mobile phase, coupled with electrospray ionization mass spectrometry (ESI–MS). The protonated analyte was quantified by selected-ion monitoring (SIM) with a quadrupole mass spectrometer in a positive-ion mode. The calibration curve was linear (r = 0.9990) over the concentration range: 0.039–2.5 ng mL?1. Intra-day and inter-day precision (RSD%) were less than 13.05%. The established method was successfully applied for the determination of pharmacokinetics of flupentixol in human plasma.  相似文献   

3.
An on-line HPLC–ESI–MS–MS method has been developed for determination of glutathione and phytochelatins (PC) in plant tissues. For sample pretreatment, dithiothreitol (DTT) must be added at the very beginning, as an anti-oxidant. Optimization of instrumental conditions i.e. composition of HPLC mobile phase, ionization efficiency of the electrospray interface, and MS–MS detection in the multiple ion-monitoring mode, are the central aspects of this work. A polystyrene-packed column was found to be superior to a standard silica-packed reversed-phase column. A concave quadratic gradient of ammonium formate buffer and acetonitrile was found to be optimum. The limits of quantitation were 0.2 mol kg–1 plant tissue for glutathione and PC. The method has been applied to analysis of tissue samples from Vicia faba grown in Cd-containing nutrient solutions.Dedicated to the memory of Wilhelm Fresenius  相似文献   

4.
Rosmarinus eriocalyx (rosemary or Elyazir) is an endemic species growing in arid steppe and rocky mountain in the South-West Algeria. This plant is well known in Algeria and Morocco due to its medicinal properties. However, little is known about its phytochemical composition. For this purpose, natural antioxidant compounds from R. eriocalyx were recovered by solid-liquid extraction and characterized by reversed-phase high-performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry using negative and positive ionization modes. This analytical methodology enabled the characterization of 101 compounds, which were distributed in five major categories namely hydroxycinnamic acid derivatives, hydroxybenzoic acid derivatives, flavonoids, phenolic diterpenes and phenolic triterpenes. Moreover, the studied extract generally showed free radical-scavenging and reductive abilities in the range of butylated hydroxyanisole, butylated hydroxytoluene, α-tocopherol, and ascorbic acid. Therefore, the result suggests that the aqueous-methanolic extract of R. eriocalyx could serve as a potential source of antioxidants.  相似文献   

5.
The aim of this work was to develop a new technique using flow injection analysis combined with LC–ESI–MS which allows identification of dyes in ballpoint pen inks. A sample preparation procedure for the extraction of dyes from ballpoint pen strokes has been developed. The characteristic group of ions for each sample of 21 studied ballpoint pen inks corresponding to the present dyes has been determined using flow injection method. LC separation conditions for identified dyes have been optimized on reversed-phase sorbent based on silica gel. The best composition of the mobile phase for the dyes mixture LC separation was 0.1% aqueous formic acid and acetonitrile. Detection of dyes was carried out using mass spectrometry with electrospray ionization in positive and negative modes after reversed-phase liquid chromatography separation. Dye composition of ink was additionally confirmed comparing the data obtained from the literature. Flow injection analysis allows obtaining intensive ions of unknown strokes. It is difficult to get this information using only chromatographic methods, because dyes peak intensity can be low and noise of basic line high. Flow injection method allows distinguishing the analyzed 21 ballpoint pens by determining a characteristic set of dyes. The developed flow injection technique is very simple and quick. As a result, a novel approach for the identification of dyes in the ballpoint pen inks by flow injection analysis with LC–ESI–MS and UV detection without using standard dye samples has been established. It can be an effective alternative to the existing LC–DAD–MS and IR spectroscopy methods.  相似文献   

6.
A rapid and sensitive liquid chromatography–electrospray ionization mass spectrometry method was developed for the determination of aesculin in rat plasma. The analyses were chromatographed on a Zorbax Extend-C18 analytical column (150 × 2.1 mm I.D., 5 µm) with 30:70 (v/v) methanol–0.1% formic acid as mobile phase. Detection was performed by triple-quadrupole tandem mass spectrometry in multi-reaction-monitoring mode with an electrospray ionization source. The method was validated for accuracy and precision, and linearity in the two matrices was good. The assay was linear in the range 12.5–1,800 ng mL?1. The lower limit of quantification of aesculin (LLOQ) was 12.5 ng mL?1. The recovery of aesculin and tinidazole (IS) were well above 85%. The within- and between-batch accuracy was 100–104% and 97–109%, respectively. There were no stability-related problems in the procedure for the analysis of aesculin. The method was successfully used in a preclinical study of the pharmacokinetics of aesculin in rats.  相似文献   

7.
High-throughput quantification with label-free methods has received considerable attention in electrospray ionization(ESI)-mass spectrometry(MS),but the manner by which MS signals respond to peptide concentration remains unclear in proteomics.We developed a new mathematical formula to describe the intrinsic log-log relationship between the MS intensity response and peptide concentration in an analytical ESI process.Experimental results showed that the calibration curve is fairly fit to the log-log formula with a linear dynamic range of approximate four to five orders of magnitude.However,we found that the ionization of analytical peptides can be severely suppressed by coexisting matrix peptides,such that the calibration curve can be poorly leveled off on both ends.Our study suggests that the interferences from coexisting matrix peptides should be reduced in the ESI process to use the log-log calibration curve successfully for the high-throughput quantification.  相似文献   

8.
A rapid, selective and convenient liquid chromatography–mass spectrometric method for the simultaneous determination of paracetamol and caffeine in human plasma was developed and validated. Analytes and theophylline [internal standard (I.S.)] were extracted from plasma samples with diethyl ether-dichloromethane (3:2, v/v) and separated on a C18 column (150 × 4.6 mm ID, 5 μm particle size, 100 Å pore size). The mobile phase consisted of 0.2% formic acid–methanol (60:40, v/v). The assay was linear in the concentration range between 0.05 and 25 μg mL?1 for paracetamol and 10–5,000 ng mL?1 for caffeine, with the lower limit of quantification of 0.05 μg mL?1 and 10 ng mL?1, respectively. The intra- and inter-day precision for both drugs was less than 8.1%, and the accuracy was within ±6.5%. The single chromatographic analysis of plasma samples was achieved within 4.5 min. This validated method was successfully applied to study the pharmacokinetics of paracetamol and caffeine in human plasma.  相似文献   

9.

Brinzolamide (BZA) is a topical ophthalmic drug which is generally used to lower the intraocular pressure during glaucoma. It was subjected to forced degradation studies under hydrolytic (acidic, basic), oxidative, photolytic and thermal stress conditions; the drug degraded significantly in hydrolytic and oxidative conditions, leading to the formation of seven degradation products in total. It was stable on exposure to light and dry heat in the solid state. An ultra-performance liquid chromatography (UPLC) method was developed on a Waters CSH phenyl hexyl column (100 × 2.1 mm, 1.7 µm), using gradient elution of 0.1 % formic acid and methanol as mobile phase. The method was extended to quadrupole time-of-flight mass spectrometry (Q-TOF–MS) for the structural characterisation. All degradation products were comprehensively characterised by UHPLC–ESI/MS/MS experiments. The most probable mechanisms for the formation of degradation products were also proposed. In silico toxicity of the drug and its degradation products was determined using TOPKAT toxicity prediction software.

  相似文献   

10.
LC–DAD coupled with electrospray tandem mass spectrometry (LC–ESI–MS–MS) has been used to evaluate the quality of the traditional Chinese medicine Huang-Lian-Jie-Du-Tang (HLJDT). Twenty-five chromatographic peaks were obtained from a C18 analytical column by gradient elution with acetonitrile and formate buffer (containing 0.5% formic acid) at a flow rate of 1.0 mL min?1. The linearity, precision, and accuracy of the data obtained were acceptable. Thirteen components were identified by ESI–MS, and seven of these were quantitatively analyzed by LC–DAD. The method was used to analyze ten batches of HLJDT, and both chromatographic fingerprints and quantitative data were used to evaluate the quality of the HLJDT. It was concluded that this LC–DAD–ESI–MS method enables more fully validated and complete evaluation and monitoring of the quality of HLJDT.  相似文献   

11.
Melphalan is a bifunctional alkylating agent that covalently binds to the nucleophilic sites present in DNA. In this study we investigated oligonucleotides prepared enzymatically from DNA modified with melphalan. Calf thymus DNA was incubated in-vitro with melphalan and the resulting modifications were enzymatically cleaved by means of benzonase and nuclease S1. Efficient sample preconcentration was achieved by solid-phase extraction, in which phenyl phase cartridges resulted in better recovery of the modified species than C18. The applied enzymatic digestion time resulted in production of trinucleotide adducts which were efficiently separated and detected by use of reversed-phase HPLC coupled to an ion-trap mass spectrometer with electrospray ionization. It was assumed that melphalan could act as both a monofunctional and bifunctional alkylating agent. Mono-alkylated adducts were much more abundant, however, and the alkylation site was located on the nucleobases. On the other hand, we unequivocally identified cross-link formation in DNA, even though at low abundance and only a few adduct types were detected. Figure Different Alkylation reactions of Melphalan with DNA  相似文献   

12.
Summary A sensitive and selective liquid chromatographic method coupled with electrospray ionization tandem mass spectrometry (LC–ESI–MS–MS) has been developed for quantification of felodipine in human and dog plasma. Compounds were separated on a 2.0 mm × 150 mm, 5.0 m particle, C8 column with 1 m m ammonium acetate–acetonitrile, 20:80, pH 6.0, as mobile phase at a flow rate of 200 L min–1. Nifedipine was used as internal standard. Plasma samples were extracted with diethyl ether, the centrifuged upper layer was evaporated, the residue was reconstituted with mobile phase, and the reconstituted samples were injected. The analytical column lasted for at least 1000 injections. By use of multiple reaction monitoring (MRM) mode in MS–MS felodipine and nifedipine were detected without severe interference from the human or dog plasma matrix. Felodipine produced a protonated precursor ion ([M + H]+) at m/z 384 and a corresponding product ion at m/z 338. And internal standard (nifedipine) produced a protonated precursor ion ([M + H]+) at m/z 347 and a corresponding product ion at m/z 315. Detection of felodipine in human and dog plasma was accurate and precise, with a limit of quantification of 0.05 ng mL–1. The method has been successfully applied to preliminary pharmacokinetic study of felodipine in human and dog plasma.  相似文献   

13.
The purpose of this article was to develop a rapid and robust LC–MS–MS method for quantifying shikonin and deoxyshikonin simultaneously in rat plasma using emodin as internal standard. The LC system consisted of an Agilent ZORBAX SB-C18 (1.8 μm, 250 × 4.6 mm, 20 °C) column. Elution with an isocratic mobile phase consisted of methanol/10 mM ammonium acetate in water/acetonitrile containing 0.05% formic acid (45:10:45, v/v/v) at a flow rate of 0.8 mL min?1 yielded sharp, high-resolved peaks within 12 min. The lower limits of quantitation were 0.5 ng mL?1 for shikonin, and 8 ng mL?1 for deoxyshikonin. Correlation coefficient (r) values for the linear range of two analytes were greater than 0.99. Assay precision was <13% and accuracy was 87–99%. This newly developed method was used to the pharmacokinetic studies of the shikonin analogues in rats after intravenous administration (n = 4).  相似文献   

14.
A liquid chromatography coupled with photodiode array detection and electrospray ionization tandem mass spectrometry method was first developed for a chemical fingerprint analysis of Euonymus alatus (Thuhb) siebold (EAS) and rapid identification of major compounds in the fingerprints. Fingerprint profiles were found to be consistent for the herbs acquired from different locations, but the relative abundance of peaks was varied. Twelve peaks were chosen as the common peaks. Quercetin and rutin were detected by comparing the retention times, MS and UV spectra with the standards. The relative retention time and relative peak area of the 12 peaks in the fingerprint were calculated by setting the quercetin as the reference peak. The experimental data were used for similarity calculation and hierarchical clustering analysis. By comparing the UV and MS spectra data with those of the authentic standards and literature, five main peaks in the fingerprints were identified. Finally, five medicinal portions of the herb (leaf, fruit, stem, pterygium and root) were also analyzed by this method. It was found that there were similar chemical components in different parts of this herb but the contents were very different. The developed fingerprint assay was specific and could be readily utilized for comprehensive evaluation of EAS, as well as to distinguish different medicinal portions.  相似文献   

15.
A rapid and sensitive method was developed and validated for the determination of MCYST (microcystin)-RR, -LR, and [Dha7] MCYST-LR in rat plasma by liquid chromatography-tandem mass spectrometry. The analytes were extracted from rat plasma by protein precipitation, followed by solid-phase extraction. Liquid chromatography with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MCYST-RR, -LR, and [Dha7] MCYST-LR in rat plasma. The recoveries for each analyte in rat plasma ranged from 70.8 to 88.7%. The calibration curve was linear within the range from 0.005 to 1.25 μg mL?1. The limit of detection were 1.4, 1.0, 0.6 ng mL?1 for MCYST-RR, -LR, and [Dha7] MCYST-LR. The overall precision was determined on three different days. The values for within- and between-day precision in rat plasma were within 15%. This method was applied to the identification and quantification of microcystins in rat plasma with acute exposure of microcystins via intravenous injection.  相似文献   

16.
Extracts from wool dyed with sawwort (Serratula tinctoria L.) obtained with methanol/formic acid and methanol/hydrochloric acid solutions were examined by high-performance liquid chromatography with UV detection coupled with electrospray ionization tandem mass spectrometry. Chromatograms and mass spectra were registered in the negative ion mode under various orifice voltages and collision energies, which enabled us to observe signals corresponding to [M???H]? ions and also Y? and/or Y?? ions, which were further subjected to fragmentation. The results obtained allowed us to define previously unknown constituents of sawwort, which are proposed as specific markers for its identification: chlorogenic acid and its isomers, luteolin-O-glucuronides, eriodictyol-O-glucuronides, and diosmetin-O-glucuronides. Moreover, it was found that during extraction, flavonoid O-glucuronides react with methanol in the presence of hydrochloric acid, forming stable O-methylated derivatives.  相似文献   

17.
18.
A high-performance liquid chromatography-electrospray ionization-mass spectromentry (LC–ESI–MS) method has been developed for the determination of picroside II in dog plasma. Plasma samples were deproteinated with acetonitrile and a Hypersil ODS2 column was used with a mobile phase consisted of methanol-water. The determination was validated in the concentration range of 0.10–50 μg mL?1 using 50 μL of plasma. The method was successfully applied to a pharmacokinetic study of picroside II.  相似文献   

19.
Zhang  Chunhua  Wu  Huiqin  Huang  Xiaolan  Zhu  Zhixin  Luo  Huitai  Huang  Fang  Lin  Xiaoshan 《Chromatographia》2012,75(9-10):499-511

A sensitive and selective method for simultaneous determination of 29 toxic alkaloids in human blood and 31 in urine using high-performance liquid chromatography–electrospray ionization-tandem mass spectrometry was developed and validated. The samples were diluted with 0.1 mol L−1 HCl, and the target alkaloids were purified by solid phase extraction. The separation of 31 alkaloids was carried out on a C18 column using a gradient mobile phase with 10 mmol L−1 ammonium formate in water with 0.1% formic acid and methanol at the rate of 0.25 mL min−1. The triple-quadrupole mass spectrometer equipped with an electrospray source in the positive mode was set up in the dynamic multiple reactions monitoring mode (dynamic MRM) to detect the ion transitions of 31 alkaloids. The calibration curves were linear over a range of 0.5–400, 1–400, or 4–400 μg L−1 for target alkaloids in human blood and urine, and the correlation coefficients (r 2) was higher than 0.9943. The limit of determination and limit of quantification were 0.2–1 and 0.5–4 μg L−1 for blood and urine, respectively. The only exceptions were sanguinarine and chelerythrine in human blood. All the target alkaloids were stable under the test condition. In addition, the solvent effect and reconstituted solution were investigated. The method was validated and proved to be accurate and precise over the studied concentrations and suitable for poisoning diagnosis and forensic toxicology.

  相似文献   

20.
A liquid chromatography separation with electrospray ionisation and tandem mass spectrometry detection method was developed for the simultaneous quantification of ten commonly handled cytotoxic drugs in a hospital pharmacy. These cytotoxic drugs are cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. The chromatographic separation was carried out by RPLC in less than 21 min, applying a gradient elution of water and acetonitrile in the presence of 0.1% formic acid. MS/MS was performed on a triple quadrupole in selected reaction monitoring mode. The analytical method was validated to determine the limit of quantification (LOQ) and quantitative performance: lowest LOQs were between 0.25 and 2 ng mL(-1) for the ten investigated cytotoxic drugs; trueness values (i.e. recovery) were between 85% and 110%, and relative standard deviations for both repeatability and intermediate precision were always inferior to 15%. The multi-compound method was successfully applied for the quality control of pharmaceutical formulations and for analyses of spiked samples on potentially contaminated surfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号