首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
A fast and simple capillary zone electrophoresis method was developed and validated for the determination of lidocaine in skin using tape samples. Separation was performed in a 350 mm (265 mm to window) x 50 microm i.d. fused silica capillary using a background electrolyte of phosphoric acid-Tris pH 2.5. The extraction of lidocaine from tape samples was achieved using methanol, which was diluted to 50% with water before injection. Procaine was the internal standard. The migration times for procaine and lidocaine were 2.9 and 3.2 min, respectively. The limit of quantification for lidocaine was 50 microg, with signal to noise ratio greater than 10. The calibration curve was linear from 50 to 1000 microg with r(2) greater than 0.99. The CV for both within- and between-assay imprecision and the percentage of inaccuracy for the quality control samples including lower and upper limits of quantitation were 97%. The accuracy and selectivity of this method allowed the measurement of lidocaine in tape samples obtained from a skin tape stripping study of local anesthetics in healthy subjects.  相似文献   

2.
《Analytical letters》2012,45(8):1377-1388
Abstract

4-[(5,6,7,8-Tetrahydro-5,5,8,8-tetramethyl-2-naphthyl)-carbamoyl] benzoic acid (Am-80) is a novel retinobenzoic acid derivative possessing retinoid activity. Plasma concentration of this drug in clinical use is very low, less than 1 ng/ml, and could not be measured with direct immunoassays. A combination of high-performance liquid chromatography (HPLC) and radioimmunoassay (RIA) was developed for this drug in human plasma. Am-80 in 0.5 ml of human plasma was extracted by solid-phase extraction, and the extract was purified by reversed-phase HPLC. The immunoreactivity in the fraction of the eluate was measured by competitive RIA. The within- and between-assay variances were 4.1 to 15.5% and 4.1 to 7.0%, respectively. The limit of quantification was 0.04 ng/ml in human plasma, which was much lower than that of direct RIA, 0.6 ng/ml, previously reported. This assay system could be used to observe the pharmacokinetics of Am-80 in human even after dermal application at very low dose.  相似文献   

3.
A simple, specific and sensitive HPLC method has been developed for the determination of metoprolol in human plasma and urine. Separation of metoprolol and atenolol (internal standard) was achieved on an Ace C18 column (5 μm, 250 mm×4.6 mm id) using fluorescence detection with λex=276 nm and λem=296 nm. The mobile phase consists of methanol–water (50:50, v/v) containing 0.1% TFA. The analysis was performed in less than 10 min with a flow rate of 1 mL/min. The assay was linear over the concentration range of 3 – 200 and 5 – 300 ng/mL for plasma and urine, respectively. The LOD were 1.0 and 1.5 ng/mL for plasma and urine, respectively. The LOQ were 3.0 and 5.0 ng/mL for plasma and urine, respectively. The extraction recoveries were found to be 95.6 ± 1.53 and 96.4 ± 1.75% for plasma and urine, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

4.
A novel capillary zone electrophoresis separation coupled to electro spray ionization time‐of‐flight mass spectrometry method was developed for the simultaneous analysis of six toxic alkaloids: brucine, strychnine, atropine sulfate, anisodamine hydrobromide, scopolamine hydrobromide and anisodine hydrobromide in human plasma and urine. To obtain optimal sensitivity, a solid‐phase extraction method using Oasis MCX cartridges (1 mL, 30 mg; Waters, USA) for the pretreatment of samples was used. All compounds were separated by capillary zone electrophoresis at 25 kV within 12 min in an uncoated fused‐silica capillary of 75 μm id × 100 cm and were detected by time‐of‐flight mass spectrometry. This method was validated with regard to precision, accuracy, sensitivity, linear range, limit of detection (LOD), and limit of quantification (LOQ). In the plasma and urine samples, the linear calibration curves were obtained over the range of 0.50–100 ng/mL. The LOD and LOQ were 0.2–0.5 ng/mL and 0.5–1.0 ng/mL, respectively. The intra‐ and interday precision was better than 12% and 13%, respectively. Electrophoretic peaks could be identified by mass analysis.  相似文献   

5.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive, specific, accurate and reproducible analytical method was developed and validated to quantify perfluorooctanoic acid (PFOA) in human serum. After initial extraction with an ion-paring reagent, the procedure for quantifying PFOA is based on high-performance liquid chromatography (HPLC) interfaced to negative ion tandem mass spectrometry, operating in selected ion monitoring mode. The retention times of PFOA and its internal standard (D,L-malic acid) were 5.85 and 1.70 min, respectively. The assay was linear over the range 0-500 ng/mL, with a lower limit of quantification (LOQ) of 25 ng/mL, and with a coefficient of variation (CV) of 7.3%. The lower limit of detection (LOD) was assessed as 10 ng/mL. The overall precision and accuracy were assessed on three different days. The within- and between-day precision was < or =9.7 and 6.8%, respectively, and the accuracy was in the range 96-114%. The mean extracted recovery assessed at three different concentrations (100, 250, and 500 ng/mL) was always more than 85%. With this method no derivatization procedure was needed, thus avoiding possible thermal and chemical decomposition reactions of PFOA. The assay was applied to quantify perfluorooctanoic acid in serum from employees exposed to fluorochemicals commonly used in industrial applications for polymer production. The quantitative results for PFOA blood levels were found to vary between 100 and 982 ng/mL.  相似文献   

7.
A simple, sensitive, rapid, and reproducible high-performance liquid chromatographic method is developed and validated for the determination of doxazosin in human plasma without a solvent extraction procedure. This method involves plasma protein precipitation using methanol. The structurally related compound prazosin is used as an internal standard. Doxazosin is detected with high sensitivity using spectrofluorimetry. Over the concentration range 0.5-20 ng/mL, the absolute recovery values are all greater than 98%. The method has a quantitation limit of 0.5 ng/mL. The intra- and interday coefficient of variation and inaccuracy values are all less than 8% and 7%, respectively. Therefore, the method has been applied in pharmacokinetic studies of doxazosin.  相似文献   

8.
In this study, a sensitive, specific assay for the determination of TNP-470 and its two major metabolites M-IV (also know as AGM-1883) and M-II in human plasma is reported. The assay involves liquid-liquid extraction of acidified plasma followed by reversed-phase high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry. A liquid-liquid extraction using an organic solvent mixture (methyl-tert-butyl-ether-hexane, 1:1, v/v) is used in place of solid-phase extraction because it provides consistent recoveries for all analytes, including the internal standard. Retention times for the analytes and internal standard are less than 7 min. Within- and between-day precision is < or = 6.5% and < or = 13.3% relative standard deviation, respectively, for the three analytes. The lower limits of quantitation are 0.25, 0.5, and 1.0 ng/mL for TNP-470, M-IV, and M-II, respectively.  相似文献   

9.
Solid-phase microextraction (SPME), using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber, interfaced with liquid chromatography-fluorescence detection (LC-FD) has been applied to the determination of Ochratoxin A (OTA) in wine samples. Compared to the most widely adopted extraction/clean-up procedure based on immunoaffinity columns (IAC), the solventless extraction is simpler and cost-effective, requiring the simple immersion of the fiber in diluted wine samples. Furthermore, a fast LC separation is achieved under isocratic conditions. The linear range investigated in wine was 0.25-8 ng/mL; at fortification levels of 0.5 and 2 ng/mL, within-day intra-laboratory precision (repeatability) values, expressed as RSD%, were 5.9 and 5.1, respectively, whereas between days (n = 4) precision was 8.5 and 7.1%, respectively. The limit of detection (LOD) at a signal-to-noise (S/N) ratio of 3 was 0.07 ng/mL; the limit of quantification (LOQ) calculated at S/N = 10 was 0.22 ng/mL, well below the European regulatory level of 2 ng/mL. The potential of the method has been demonstrated by the analysis of a number of different wine samples.  相似文献   

10.
The accurate determination of prilocaine HCl levels in plasma is important in both clinical and pharmacological/toxicological studies. Prilocaine HCl is quickly hydrolyzed to o-toluidine, causing methemoglobinemia. For this, the present work describes the methodology and validation of a GC-MS assay for determination of prilocaine HCl with lidocaine HCl as internal standard in plasma. The validation parameters of linearity, precision, accuracy, recovery, specificity, limit of detection and limit of quantification were studied. The range of quantification for the GC-MS was 20-250 ng/mL in plasma. Within-day and between-day precision, expressed as the relative standard deviation (RSD) were less than 6.0%, and accuracy (relative error) was better than 9.0% (n = 6). The analytical recovery of prilocaine HCl and IS from plasma has averaged 94.79 and 96.8%, respectively. LOQ and LOD values for plasma were found to be 20 and 10 ng/mL, respectively. The GC-MS method can be used for determination from plasma of prilocaine HCl in routine measurement as well as in pharmacokinetic studies for clinical use.  相似文献   

11.
A simple and sensitive method for the determination of nitrendipine in rat plasma was developed using high-performance liquid chromatography (HPLC). The procedure involves extraction of nitrendipine in dichloromethane/sodium hydroxide, followed by reversed phase HPLC using a Waters, Spherisorb ODS2 (250 x 4.6 mm, 5 microm) column and UV detection at 238 nm. The retention times of nitrendipine and internal standard (felodipine) were 5.0 min and 7.5 min, respectively. The calibration curves were linear over the range of 5 ng/mL (lower limit of quantification, LOQ) to 200 ng/mL for nitrendipine. The intra- and inter-day coefficients of variation for all criteria of validation were less than 15% over the linearity range. The sensitivity and precision of the method were within the accepted limits (< 15%) throughout the validation period. The present method was also successfully applied for the study of plasma pharmacokinetics of nitrendipine loaded solid lipid nanoparticles (SLN) in rats.  相似文献   

12.
A simple and sensitive GC-EI-MS method using solvent extraction and evaporation was developed for the determination of olanzapine concentrations in plasma samples. Because olanzapine and promazine, which was used as the internal standard (IS), are nitrogenous bases, they can adsorb to the weakly acidic silanol groups on the surfaces of glass centrifuge tubes during solvent extraction and evaporation. Silylation of the glass tubes, addition of triethylamine (TEA), and use of a sample solution with a basic pH could prevent adsorption loss. The extraction method involved mixing plasma (500 μL) in a silylated glass tube with a promazine solution (2 μg/mL, 25 μL) in methanol containing 1% TEA. After addition of aqueous sodium carbonate (0.5 mol/L, pH 11.1, 1 mL) and extraction into 3 mL of dichloromethane/n-hexane (1:1, v/v) containing 1% TEA, the organic phase was evaporated to dryness in a silylated glass tube. The residue was dissolved in ethyl acetate containing 1% TEA (50 μL). For GC-EI-MS analysis, the calibration curves of olanzapine in human plasma were linear from 0.5 to 100 ng/mL. Intra- and interday precisions in plasma were both less than 7.36% (coefficient of variation), and the accuracy was between 94.6 and 110% for solutions with concentrations greater than 0.5 ng/mL. The limit of quantification was 0.5 ng/mL in plasma. The assay was applied to therapeutic drug monitoring in samples from three schizophrenic patients.  相似文献   

13.
A novel and porous solid‐phase microextraction fiber was prepared by quick and simple galvanic displacement reaction and applied to the determination of some polycyclic aromatic hydrocarbons in sunflower oil. The parameters affecting the porosity and thickness of the fiber, and parameters affecting the extraction efficiency, including the extraction time, temperature, and ionic strength, were investigated and optimized. The morphology of prepared fiber was characterized by optical and scanning electron microscopy and thermal and chemical stabilities of the fiber were studied. Under the optimum conditions, the limits of detection ranged between 0.1 ng/mL for pyrene to 1.2 ng/mL for anthracene, and LOQ ranged between 0.3 ng/mL for pyrene to 3.6 ng/mL for anthracene. The relative standard deviations, including repeatability (within fibers) and reproducibility (between fibers), varied between 3.2–8.9 and 5.6–9.8%, respectively.  相似文献   

14.
A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and reproducible for the pharmacokinetic analysis of BMS-204532 in dog plasma.  相似文献   

15.
A simple and sensitive procedure utilizing GC-MS for the identification and quantitation of clenbuterol in biofluids and tissues is described. This improved method utilizes trimethylboroxine for the derivatization of clenbuterol, requires only 1 mL/g of biological sample, and most importantly does not require an extra cleaning step for urine specimens prior to extraction. Linear quantitative response curves have been generated for derivatized clenbuterol over a concentration range of 5-200 ng/mL. The extraction efficiency at four representative points of the standard curve exceeded 90% in both specimen types (plasma and urine). Linear regression analyses of the standard curve in both specimen types exhibited correlation coefficients ranging from 0.997 to 1.000. The Limit of detection (LOD) and Limit of quantitation (LOQ) values for plasma specimens were determined to be 0.5 and 1.5 ng/mL respectively. For urine specimens, LOD and LOQ values were 0.2 and 0.7 ng/microL respectively. Percentage recoveries ranged from 91 to 95% for urine and 89 to 101% for plasma. Precision and accuracy (within-run and between-run) studies reflected a high level of reliability and reproducibility of the method. In addition to its reliability, sensitivity and simplicity, this modified procedure is more efficient and cost effective, requiring less time, only 1 mL of sample, and minimal amounts of extraction solvents. The applicability of the method for the detection and quantitation of clenbuterol in biological tissues of rats treated with the drug was demonstrated successfully. For comparative analysis of clenbuterol in plasma and liver samples, both GC-MS and enzyme immunoassay (EIA) methods are found to be suitable. Due to potential antibody-cross reactivity with EIA, the GC-MS method is the method of choice for most samples because of its specificity. However, the EIA method is considered the method of choice for analysis of clenbuterol found in concentrations below the limits of quantitation by GC-MS due to its sensitivity.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) method for the analysis of coenzyme Q10 (CoQ10) in human seminal plasma was developed and applied to investigate its clinical significance as a reference index relating to oxidative stress and infertile status of spermatozoa. After precipitation of proteins in seminal plasma with methanol, CoQ10 and coenzyme Q9 (CoQ9; internal standard) were extracted with hexane. The supernatant after centrifugation was evaporated to dryness with nitrogen at 45 degrees C. The residue was re-dissolved in isopropanol. HPLC separation of the sample solution was performed on a Lichrospher C(18) column with a mobile phase composed of isopropanol-methanol-tetrahydrofuran in the ratio of 55:39:6 (v/v/v) at a flow rate of 1.0 mL/min. Under the chromatographic conditions described, the CoQ10 and CoQ9 had retention times of approximately 5.83 and 4.97 min, respectively. The peaks were detected at UV 275 nm. Good separation and detectability of CoQ10 in human seminal plasma were obtained. The method was linear in the range 0.01-10.00 microg/mL. The relative standard deviations within- and between-assay for CoQ10 analysis were 0.85 and 1.86%, respectively. The average recoveries were 94.1-99.0% for the human seminal plasma samples. The CoQ10 levels in seminal plasma of 195 patients and 23 control subjects were studied. CoQ10 concentrations in the two populations were: 37.1 +/- 12.2 ng/mL in the fertile group and 48.5 +/- 20.4 ng/mL in the infertile group. The large difference (p < 0.01) between the fertile and infertile populations is evident.  相似文献   

17.
A high-performance liquid chromatographic method for the determination of atazanavir (ATV) in human plasma is developed and validated. The method involves a rapid and simple solid-phase extraction (SPE) of ATV using Bond-elut C18 3 mL cartridge. The separation of ATV from internal standard and endogenous components is achieved using an isocratic elution on an octyl column and an UV detector set at 260 nm. The method is linear from 20 to 10,000 ng/mL (mean r2 = 0.9991, n = 10). The observed intra- and inter-day assay precision ranged from 2.2% to 14.7%[at the lower limit of quantitation (LOQ)], whereas accuracy varies between 1.0% and 14% (at LOQ). Mean drug recovery is 80.5% for ATV and 78.4% for IS. The method is found to be precise and accurate, practical enough for therapeutic drug monitoring in routine clinical practice and is applied for the assessment of 24-h ATV plasma concentration-time profiles in HIV-infected pregnant women.  相似文献   

18.
19.
A simple, sensitive and rapid method for the determination of diisopropylfluorophosphate (DFP) in rat plasma and brain tissue using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. A 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was selected for sampling. The main parameters affecting the SPME process such as extraction and desorption temperature, extraction and desorption time, salt addition, and fiber preheating time were optimized in each matrix to enhance the extraction efficiency of the method. The lower limits of quantitation for DFP in plasma and brain tissue were 1 ng/mL and 3 ng/g, respectively. The method showed good linearity over the range from 1-100 ng/mL in plasma and 3-300 ng/g in brain tissue with correlation coefficient (R(2)) values higher than 0.995. The precision and accuracy for intra-day and inter-day were less than 10%. The relative recoveries in plasma and brain for DFP were greater than 50%. Stability tests including autosampler and freeze and thaw were also investigated. This validated method was successfully applied to study the neurobehavioral effects of low-level organophosphate exposures. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

20.
建立了超高效液相色谱-三重四极杆质谱高灵敏测定尿液和血浆中α-鹅膏毒肽、β-鹅膏毒肽和γ-鹅膏毒肽的方法。经过免疫亲和柱净化,尿液样品浓缩20倍、血浆样品浓缩10倍,以Kinetex Biphenyl色谱柱(100 mm×2.1 mm, 1.7 μm)作为分析柱,甲醇-0.005%(v/v)甲酸水溶液作为流动相进行梯度洗脱分离,电喷雾电离、负离子、多反应监测模式下检测,外标法定量。3种鹅膏毒肽的线性范围为0.1~200 ng/mL,相关系数(r)>0.999。尿液和血浆中3种鹅膏毒肽的基质效应和提取回收率分别为92%~108%和90%~103%,变异系数均小于13%。尿液中3种鹅膏毒肽的准确度为-9.4%~8.0%,重复性和中间精度分别为3.0%~14%和3.5%~18%,当取样量为2.00 mL时,方法的检出限均为0.002 ng/mL;血浆中3种鹅膏毒肽的准确度为-13%~8.0%,重复性和中间精度分别为3.9%~9.7%和5.5%~12%,当取样量为1.00 mL时,方法的检出限均为0.004 ng/mL。该法操作简单、灵敏、准确,已在中毒患者摄入野生蘑菇后138 h的尿液中检出0.0067 ng/mL α-鹅膏毒肽和0.0059 ng/mL β-鹅膏毒肽。该法已成功解决中毒患者尿液和血浆中超痕量鹅膏毒肽的检测难题,对于疑似中毒病人的早诊断、早治疗、降低死亡率都具有非常重要意义,也为今后开展此类毒素毒理作用及机体代谢规律的研究提供了可靠的技术支撑。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号