首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Multivariate methods, such as principal component analysis (PCA) and multivariate curve resolution (MCR), are often employed to aid the analysis of large complex data sets such as time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) images. There is, however, much confusion over the most appropriate choice of method for any given application and the effects of data preprocessing, which is exacerbated by the confusing terminologies and the use of jargon in this field. In the present study, a simple model system consisting of a ToF‐SIMS image of an immiscible polymer blend is used to evaluate PCA and MCR in the accurate identification, localisation and quantification of the phase‐separated polymer domains, using four data preprocessing methods (no scaling, normalisation, variance scaling and Poisson scaling). This highlights significant issues and challenges in the quantitative multivariate analysis of mixed organic systems, including the discrimination of chemically significant features from experimental noise, the resolution of weak chemical contributions and potential bias introduced by data preprocessing. Multivariate analysis using Poisson scaling, identified as the most suitable data preprocessing method for both PCA and MCR, demonstrates a marked improvement upon traditional (manual) analysis and provides valuable additional information that is difficult to detect using traditional analysis. Using these results, we present recommendations for the optimum use of multivariate analysis by analysts and provide guidance on selecting the most appropriate methods. Confusing terminology is also clarified. © Crown copyright 2008. Reproduced with the permission of Her Majesty's Stationery Office. Published by John Wiley & Sons, Ltd.  相似文献   

2.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) data collected in single ion counting mode suffers from dead‐time effects that lead to potentially confusing artefacts when common multivariate analysis (MVA) methods are applied to the data. These artefacts can be eliminated by applying an advanced Poisson dead‐time correction that accounts for the signal intensity in the dead‐time window preceding each time channel. Because this correction is nonlinear, it changes the noise distribution in the data. In this work, the accuracy of this dead‐time correction and the noise characteristics of the corrected data have been analysed for spectra with small numbers of primary ion pulses. A simple but accurate equation for estimating the standard deviation in the advanced dead‐time corrected data has been developed. Based on these results, a scaling procedure to enable successful MVA of advanced dead‐time corrected ToF‐SIMS data has been developed. The improvements made possible by using the advanced dead‐time correction and our recommended scaling are presented for principal components analysis of a ToF‐SIMS image of aerosol particles on polytetrafluoroethylene. Recommendations are made for using the advanced dead time correction and scaling ToF‐SIMS data in order optimize the outcomes of MVA. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) provides detailed molecular insight into the surface chemistry of a diverse range of material types. Extracting useful and specific information from the mass spectra and reducing the dimensionality of very large datasets are a challenge that has not been fully resolved. Multivariate analysis has been widely deployed to assist in the interpretation of ToF‐SIMS data. Principal component analysis is a popular approach that requires the generation of peak lists for every spectrum. Peak list sizes and the resulting data matrices are growing, complicating manual peak selection and analysis. Here we report the generation of very large ToF‐SIMS peak lists using up‐binning, the mass segmentation of spectral data in the range 0 to 300 m/z in 0.01 m/z intervals. Time‐of‐flight secondary ion mass spectrometry data acquired from a set of 4 standard polymers (polyethylene terephthalate, polytetrafluoroethylene, poly(methyl methacrylate), and low‐density polyethylene) are used to demonstrate the efficacy of this approach. The polymer types are discriminated to a moderate extent by principal component analysis but are easily skewed with saturated species or contaminants present in ToF‐SIMS data. Artificial neural networks, in the form of self‐organising maps, are introduced and provide a non‐linear approach to classifying data and focussing on similarities between samples. The classification outcome achieved is excellent for different polymer types and for spectra from a single polymer type generated by using different primary ions. This method offers great promise for the investigation of more complex systems including polymer classes and blends and mixtures of biological materials.  相似文献   

4.
Cluster LMIGs are now regarded as the standard primary ion guns on time‐of‐flight secondary ion mass spectrometers (ToF‐SIMS). The ToF‐SIMS analyst typically selects a bombarding species (cluster size and charge) to be used for material analysis. Using standard data collection protocols where the analyst uses only a single primary bombarding species, only a fraction of the ion‐beam current generated by the LMIG is used. In this work, we demonstrate for the first time that it is possible to perform ToF‐SIMS analysis when all of the primary ion intensity (clusters) are used; we refer to this new data analysis mode as non‐mass‐selected (NMS) analysis. Since each of the bombarding species has a different mass‐to‐charge ratio, they strike the sample at different times, and as a result, each of the bombarding species generates a spectrum. The resulting NMS ToF‐SIMS spectrum contains contributions from each of the bombarding species that are shifted in time. NMS spectra are incredibly complicated and would be difficult, if not impossible, to analyze using univariate methodology. We will demonstrate that automated multivariate statistical analysis (MVSA) tools are capable of rapidly converting the complicated NMS data sets into a handful of chemical components (represented by both spectra and images) that are easier to interpret since each component spectrum represents a unique and simpler chemistry. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) is a powerful tool for determining surface information of complex systems such as polymers and biological materials. However, the interpretation of ToF‐SIMS raw data is often difficult. Multivariate analysis has become effective methods for the interpretation of ToF‐SIMS data. Some of multivariate analysis methods such as principal component analysis and multivariate curve resolution are useful for simplifying ToF‐SIMS data consisting of many components to that explained by a smaller number of components. In this study, the ToF‐SIMS data of four layers of three polymers was analyzed using these analysis methods. The information acquired by using each method was compared in terms of the spatial distribution of the polymers and identification. Moreover, in order to investigate the influence of surface contamination, the ToF‐SIMS data before and after Ar cluster ion beam sputtering was compared. As a result, materials in the sample of multiple components, including unknown contaminants, were distinguished. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Generation of time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) data involves two overarching processes: secondary ion production and secondary ion detection. The interpretation of ToF‐SIMS data is facilitated if the intensities of the as‐measured mass spectra are proportional to the abundances of the species under investigation. While secondary ion yield is normally taken to be a linear process, ion detection is not owing to detector dead‐time effects. Consequently, methods have been devised that attempt to linearize, or correct, data that are affected by the dead time. In this article, we review the statistics of ToF‐SIMS data generation and confirm a report in the literature that abundance estimates from so‐called Poisson corrections are biased. We show that these corrections are only unbiased asymptotically and that a rigorous probabilistic analysis can quantitatively account for the observed bias. Two sources of bias are identified, one having a statistical basis and one due to the form of the correction equation at high ion detection rates. Based on insights gained from this analysis, we propose a new correction equation, the empirical Poisson correction, which largely eliminates the statistical bias. The performance of the proposed correction is illustrated by reanalyzing 14 experimentally measured datasets that suffer from varying levels of dead‐time effects. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
Time‐of‐flight SIMS (ToF‐SIMS) imaging offers a modality for simultaneously visualizing the spatial distribution of different surface species. However, the utility of ToF‐SIMS datasets may be limited by their large size, degraded mass resolution and low ion counts per pixel. Through denoising and multivariate image analysis, regions of similar chemistries may be differentiated more readily in ToF‐SIMS image data. Three established denoising algorithms—down‐binning, boxcar and wavelet filtering—were applied to ToF‐SIMS images of different surface geometries and chemistries. The effect of these filters on the performance of principal component analysis (PCA) was evaluated in terms of the capture of important chemical image features in the principal component score images, the quality of the principal component score images and the ability of the principal components to explain the chemistries responsible for the image contrast. All filtering methods were found to improve the performance of PCA for all image datasets studied by improving capture of image features and producing principal component score images of higher quality than the unfiltered ion images. The loadings for filtered and unfiltered PCA models described the regions of chemical contrast by identifying peaks defining the regions of different surface chemistry. Down‐binning the images to increase pixel size and signal was the most effective technique to improve PCA performance. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
The maximum autocorrelation factors technique (MAF) is becoming increasingly popular for the multivariate analysis of spectral images acquired with time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) instruments. In this article, we review the conditions under which the underlying chemical information can be separated from the large‐scale, non‐uniform noise characteristic of ToF‐SIMS data. Central to this pursuit is the ability to assess the covariance structure of the noise. Given a set of replicate images, the noise covariance matrix can be estimated in a straightforward way using standard statistical tools. Acquiring replicate images, however, is not always possible, and MAF solves a subtly different problem, namely, how to approximate the noise covariance matrix from a single image when replicates are not available. This distinction is important; the MAF approximation is not an unbiased statistical estimate of the noise covariance matrix, and it differs in a highly significant way from a true estimate for ToF‐SIMS data. Here, we draw attention to the fact that replicate measurements are made during the normal course of acquiring a ToF‐SIMS spectral image, rendering the MAF procedure unnecessary. Furthermore, in the common case that detector dead‐time effects permit no more than one ion of any specific species to be detected on a single primary ion shot, the noise covariance matrix can be estimated in a particularly simple way, which will be reported. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
Image fusion allows for the combination of an image containing chemical information but low spatial resolution with a high‐spatial resolution image having little to no chemical information. The resulting hybrid image retains all the information from the chemically relevant original image, with improved spatial resolution allowing for visual inspection of the spatial correlations. In this research, images were obtained from two sample test grids: one of a copper electron microscope grid with a letter ‘A’ in the center (referred to below as the ‘A‐grid’), and the other a Tantalum and Silicon test grid from Cameca that had an inscribed letter ‘C’ (referred to below as the ‘Cameca grid’). These were obtained using scanning electron microscopy (SEM) and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). Image fusion was implemented with the Munechika algorithm. The edge resolution of the resulting hybrid image was calculated compared with the edge resolution obtained for both the individual ToF‐SIMS and SEM images. The challenges of combining complimentary datasets from different instrumental analytical methods are discussed as well as the advantages of having a hybrid image. The distance across the edge for hybrid images of the A‐Grid and the Cameca grid were determined to be 21 µm and 8 µm, respectively. When these values were compared to the original ToF‐SIMS, SEM and optical microscopy measurements, the fused image had a spatial resolution nearly equal to that obtained in the SEM image for both samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
In this paper, an improved approach to interpret results of principal component analysis (PCA) of time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) spectra is presented. Signals are typically observed in different intensity ranges in a single ToF‐SIMS spectrum due to different sensitivity factors and surface concentrations. This can complicate the PCA interpretation, because loadings are reported to be strongly affected by these intensity changes. In contrast, it is shown here that correlation loadings are unaffected by these differences. In particular, correlation loadings were successfully used to identify signals with relatively low intensity but high significance. These signals may be overlooked when only loadings are used. This is particularly true in failure analysis, where ToF‐SIMS is used to screen for initially unknown signals that may be relevant for the characteristics/failure of a product. As a model study, the concept was applied to investigate ageing of Li‐ion batteries by ToF‐SIMS. In this data set, the significance of impurities that affect the quality of Li‐ion batteries was identified only by correlation loadings, whereas the loadings were found to overestimate the influence of other matrix signals. In addition, correlation loadings aid in the chemical identification and helped to successfully assign unknown peaks.  相似文献   

11.
ToF‐SIMS spectra are formed by bombarding a surface with a pulse of primary ions and detecting the resultant ionized surface species using a time‐of‐flight mass spectrometer. Typically, the detector is a time‐to‐digital converter. Once an ion is detected using such detectors, the detector becomes insensitive to the arrival of additional ions for a period termed as the (detector) dead‐time. Under commonly used ToF‐SIMS data acquisition conditions, the time interval over which ions arising from a single chemical species reach the detector is on the order of the detector dead‐time. Thus, only the first ion reaching the detector at any given mass is counted. The event registered by the data acquisition system, then, is the arrival of one or more ions at the detector. This behavior causes ToF‐SIMS data to violate, in the general case, the assumption of linear additivity that underlies many multivariate statistical analysis techniques. In this article, we show that high‐mass‐resolution ToF‐SIMS spectral‐image data follow a generalized linear model, and we propose a data transformation and scaling procedure that enables such data sets to be successfully analyzed using standard methods of multivariate image analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
The supervised principal components (SPC) method was proposed by Bair and Tibshirani for statistics regression problems where the number of variables greatly exceeds the number of samples. This case is extremely common in multivariate spectral analysis. The objective of this research is to apply SPC to near‐infrared and Raman spectral calibration. SPC is similar to traditional principal components analysis except that it selects the most significant part of wavelength from the high‐dimensional spectral data, which can reduce the risk of overfitting and the effect of collinearity in modeling according to a semi‐supervised strategy. In this study, four conventional regression methods, including principal component regression, partial least squares regression, ridge regression, and support vector regression, were compared with SPC. Three evaluation criteria, coefficient of determination (R2), external correlation coefficient (Q2), and root mean square error of prediction, were calculated to evaluate the performance of each algorithm on both near‐infrared and Raman datasets. The comparison results illustrated that the SPC model had a desirable ability of regression and prediction. We believe that this method might be an alternative method for multivariate spectral analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The issue of automated peak selection in time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) spectra is examined in relation to the hierarchical nature of the experimental design and the related existence of observations which are not statistically independent. To avoid unreliable results, the presence of pseudoreplication should be taken into account correctly. A combination of the recommended univariate peak selection approach with some multivariate techniques, namely principal component analysis and heat map data representation, is proposed to highlight and analyze obtained results for a set of ToF‐SIMS spectra from copper phthalocyanine thin films grown on TiO2 substrates by a supersonic beam deposition apparatus. New insight is obtained on the effectiveness of the deposition for different working parameters of the process. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
As for the detection of drug body packing, skin is a typical interference factor. In this paper, multivariate data analysis was proposed to analyze the impact of fat and muscle on heroin identification based on the profile of spectra of energy dispersive X‐ray diffraction. In the space of principal components, the results showed that different pure samples (heroin, muscle, fat) clustered in different areas, whereas the location of mixture samples moved between locations of pure samples. The impact of fat and muscle lies in moving the feature points between pure materials in the space of principal components. Furthermore, the model of heroin covered by fat and muscle of different thicknesses was set up, and a linear relationship was proven to be suitable. Our findings indicate that multivariate data analysis would be a promising method in the detection of drug body packing. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
In this work a new class of ionomeric block perfluropolyether (PFPE) polyurethanes are presented; these polymers are obtained in the form of aqueous dispersions due to the presence of hydrophilic sites (ionomeric groups such as acetates or trialkylammonium salts) along the macromolecular chain, offering the chance to combine PFPEs in a variety of possible structures for coating or surface treatments with an environmentally friendly use. X‐ray photoelectron spectroscopy analysis at two different sampling depths, as well as time‐of‐flight secondary ion mass spectrometry analysis modelled by the use of principal component analysis (PCA), were used to investigate the first nanometres of the surface samples. It resulted in a clear surface enrichment in fluorine, and the different extent of the fluorine stratification will be discussed in relation to the ionic character, film‐forming from water and cross‐linking. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
Surface analysis plays a key role in understanding the function of materials, particularly in biological environments. Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) provides highly surface sensitive chemical information that can readily be acquired over large areas and has, thus, become an important surface analysis tool. However, the information‐rich nature of ToF‐SIMS complicates the interpretation and comparison of spectra, particularly in cases where multicomponent samples are being assessed. In this study, a method is presented to assess the chemical variance across 16 poly(meth)acrylates. Materials are selected to contain C6 pendant groups, and ten replicates of each are printed as a polymer microarray. SIMS spectra are acquired for each material with the most intense and unique ions assessed for each material to identify the predominant and distinctive fragmentation pathways within the materials studied. Differentiating acrylate/methacrylate pairs is readily achieved using secondary ions derived from both the polymer backbone and pendant groups. Principal component analysis (PCA) is performed on the SIMS spectra of the 16 polymers, whereby the resulting principal components are able to distinguish phenyl from benzyl groups, mono‐functional from multi‐functional monomers and acrylates from methacrylates. The principal components are applied to copolymer series to assess the predictive capabilities of the PCA. Beyond being able to predict the copolymer ratio, in some cases, the SIMS analysis is able to provide insight into the molecular sequence of a copolymer. The insight gained in this study will be beneficial for developing structure–function relationships based upon ToF‐SIMS data of polymer libraries. © 2016 The Authors Surface and Interface Analysis Published by John Wiley & Sons Ltd.  相似文献   

17.
Multivariate optical computations (MOCs) offer improved analytical precision and increased speed of analysis via synchronous data collection and numerical computation with scanning spectroscopic systems. The improved precision originates in the redistribution of integration time from spurious channels to informative channels in an optimal manner for increasing the signal‐to‐noise ratio with multivariate analysis under the constraint of constant total analysis time. In this work, MOCs perform the multiplication and addition steps of spectral processing by adjusting the integration parameters of the optical detector or adjusting the scanning profile of the tunable optical filter. Improvement in the precision of analysis is achieved via the implicit optimization of the analytically useful signal‐to‐noise ratio. The speed improvements are realized through simpler data post‐processing, which reduces the computation time required after data collection. Alternatively, the analysis time may be significantly truncated while still seeing an improvement in the precision of analysis, relative to competing methods. Surface plasmon resonance (SPR) spectroscopic sensors and visible reflectance spectroscopic imaging were used as test beds for assessing the performance of MOCs. MOCs were shown to reduce the standard deviation of prediction by 15% compared to digital data collection and analysis with the SPR and up to 45% for the imaging applications. Similarly, a 30% decrease in the total analysis time was realized while still seeing precision improvements. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Generally, dynamic secondary ion mass spectrometry (SIMS) has been mainly used as one of the most powerful tools for inorganic mass analysis. On the other hand, an Ar gas cluster ion beam (GCIB) has been developed and spread as a processing tool for surface flattening and also a projectile for time‐of‐flight (ToF) SIMS. In this study, we newly introduced an Ar‐GCIB as a primary ion source to a commercially available dynamic SIMS apparatus, and investigated mass spectra of amino acid films (such as Arginine and Glycine) and polymer films (Polyethylene: PE and Polypropylene: PP) as organic model samples. As a result, each characteristic fragment peak indicating the original molecular organic structure was observed in the acquired mass spectra. In addition, their own molecular ions of the amino acids were also clearly observed. Mass spectra of PE/PP blended‐polymer films acquired using Ar‐GCIB‐dynamic SIMS could be identified between pure PE and PE:PP = 1:3 mixture by applying principal component analysis (PCA).  相似文献   

19.
Principal component analysis (PCA) of time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS) data enables differentiating structurally similar molecules according to linear combinations of multiple peaks in their spectra. However, in order to use PCA to correctly identify variations in lipid composition between samples, the discrimination achieved must be based on chemical differences that are related to the lipid species, and not sample‐associated contamination. Here, we identify the positive‐ion TOF‐SIMS peaks that are related to phosphatidylcholine lipid headgroups and tail groups by PCA of spectra acquired from lipid isotopologs. We demonstrate that restricting PCA to a contaminant‐free lipid‐related peak set reduces the variability in the spectra acquired from lipid samples that is due to contaminants, which enhanced differentiating different lipid standards, but adversely affected the contrast in PC scores images of phase‐separated lipid membranes. We also show that PCA of a restricted data set consisting of the peaks related to lipids and amino acids increases the likelihood that the discrimination of TOF‐SIMS data acquired from intact cells is based on differences in the lipids and proteins on the cell surface, and not sample‐specific contamination without compromising sample discrimination. We expect that the lipid‐related peak database established herein will facilitate interpreting the TOF‐SIMS data and PCA results from studies of both model and cellular membranes, and enhance identifying the origins of the peaks that contribute to discriminating different types of cells. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
Variable cationisation of the alkylethoxylate surfactant Synperonic A7? has been observed during a ToF‐SIMS study of its interaction with a leaf surface, either by itself or as a component in a simple herbicide formulation. Depending on the conditions, cationisation predominantly by K+, Na+ and H+ was found. By deliberate surfactant solution doping with alkali bromides, the cationisation channel could be manipulated. Comparison of the apparent molecular weight dependence, derived from the ToF‐SIMS spectra, with that measured by HPLC‐MS, showed a further dependence on the cationising species, with Na+ giving the best match. An understanding of these effects is critical to the correct interpretation of the spectra from this surfactant. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号