首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To effectively postpone preterm birth, cervical ripening needs to be detected and delayed. As the cervix ripens, the spacing between the collagen fibers increases and fills with water, hyaluronan, decorin, and enzymes suggesting that the ultrasonic attenuation of the cervix should decrease. The decrease in ultrasonic attenuation may be detectable, leading to an effective means of detecting cervical ripening. Herein, the traditional attenuation slope-estimation algorithm based on measuring the downshift in center frequency of the ultrasonic backscattered signal with propagation depth was modified and applied to the cervix of rats. The modified algorithm was verified using computer simulations and an ex vivo tissue sample before being evaluated in in vivo animal studies. Spherically-focused f/3 transducers with 33-MHz center frequencies and with 9-mm focal lengths were used in both the simulations and experiments. The accuracy was better than 15% in the simulations, and the attenuation slope of the cervix in the ex vivo experiment was 2.6+/-0.6 dB/cm-MHz, which is comparable to 2.5+/-0.4 dB/cm-MHz measured using a through-transmission insertion loss technique. For the in vivo experiments, a statistically significant effect of ultrasonic attenuation with gestational age was not observed. The large variances in the in vivo results were most likely due to the natural variation in attenuation for biological tissue between animals.  相似文献   

2.
Attenuation estimation and imaging in the cervix has been utilized to evaluate the onset of cervical ripening during pregnancy. This feature has also been utilized for the acoustic characterization of leiomyomas and myometrial tissue. In this paper, we present direct narrowband substitution measurement values of the variation in the ultrasonic attenuation coefficient in ex vivo human uterine and cervical tissue, in the 5-10 MHz frequency range. At 5 MHz, the attenuation coefficient values are similar for the different orientations of uterine tissue with values of 4.1-4.2 dB/cm, 5.1 dB/cm for the leiomyoma, and 6.3 dB/cm for the cervix. As the frequency increases, the attenuation coefficient values increase and are also spread out, with a value of approximately 12.6 dB/cm for the uterus (both parallel and perpendicular), 16.0 for the leiomyoma, and 26.8 dB/cm for the cervix at 10 MHz. The attenuation coefficient measured increases monotonically over the frequency range measured following a power law.  相似文献   

3.
In this study, an algorithm previously developed for estimating the total ultrasonic attenuation along the propagation path from the surface of the transducer to a region of interest (ROI) in tissue, was modified to make it more practical for use in clinical settings. Specifically, the algorithm was re-derived for when a tissue mimicking phantom rather than a planar reflector is used to obtain the reference power spectrum. The reference power spectrum is needed to compensate for the transfer function of the transmitted pulse, the transfer function of transducer, and the diffraction effects that result from focusing/beam forming. The modified algorithm was tested on simulated radio frequency (RF) echo lines obtained from two samples that have different scatterer sizes and different attenuation coefficient slopes, one of which was used as a reference. The mean and standard deviation of the percent errors in the attenuation coefficient estimates (ACEs) were less than 5% and 10%, respectively, for ROIs that contain more than 10 pulse lengths and more than 25 independent echo lines. The proposed algorithm was also tested on two tissue mimicking phantoms that have attenuation coefficient slopes of 0.7 dB/cm-MHz and 0.5 dB/cm-MHz respectively, the latter being the reference phantom. When a single element spherically focused source was used, the mean and standard deviation of the percent errors in the ACEs were less than 5% and 10% respectively for windows that contain more than 10 pulse lengths and more than 17 independent echo lines. When a clinical array transducer was used, the mean and standard deviation of the percent errors in the ACEs were less than 5% and 25%, respectively, for windows that contain more than 12 pulse lengths and more than 45 independent echo lines.  相似文献   

4.
Ultrasonic attenuation is important not only as a parameter for characterizing tissue but also for compensating other parameters that are used to classify tissues. Several techniques have been explored for estimating ultrasonic attenuation from backscattered signals. In the present study, a technique is developed to estimate the local ultrasonic attenuation coefficient by analyzing the time domain backscattered signal. The proposed method incorporates an objective function that combines the diffraction pattern of the source/receiver with the attenuation slope in an integral equation. The technique was assessed through simulations and validated through experiments with a tissue mimicking phantom and fresh rabbit liver samples. The attenuation values estimated using the proposed technique were compared with the attenuation estimated using insertion loss measurements. For a data block size of 15 pulse lengths axially and 15 beamwidths laterally, the mean attenuation estimates from the tissue mimicking phantoms were within 10% of the estimates using insertion loss measurements. With a data block size of 20 pulse lengths axially and 20 beamwidths laterally, the error in the attenuation values estimated from the liver samples were within 10% of the attenuation values estimated from the insertion loss measurements.  相似文献   

5.
Lerch TP  Cepel R  Neal SP 《Ultrasonics》2006,44(1):83-92
The ultrasonic attenuation coefficient of a fluid or solid is an acoustic parameter routinely estimated for the purpose of materials characterization and defect/disease detection. This paper describes a broadband attenuation coefficient estimation technique that combines two established estimation approaches. The key elements of these two approaches are: (1) the use of magnitude spectrum ratios of front surface, first back surface, and second back surface reflections from interfaces of materials with plate-like geometries, and (2) the use of an experimental diffraction correction approach to avoid diffraction losses. The combined estimation approach simplifies the attenuation coefficient estimation process by eliminating the need to explicitly make diffraction corrections or calculate reflection/transmission coefficients. The approach yields estimates of the attenuation coefficient, reflection coefficient, and material density. Models, experimental procedures, and signal analysis procedures, which support implementation of the approach, are presented. Attenuation coefficient and reflection coefficient estimates are presented for water and solid samples with estimates based on measurements made with multiple transducers.  相似文献   

6.
王璐  武丽伟  魏乐  高娟  孙翠丽  柴培  李道武 《中国物理 B》2014,23(2):27802-027802
The accuracy of attenuation correction in positron emission tomography scanners depends mainly on deriving the reliable 511-keV linear attenuation coefficient distribution in the scanned objects. In the PET/CT system, the linear attenu- ation distribution is usually obtained from the intensities of the CT image. However, the intensities of the CT image relate to the attenuation of photons in an energy range of 40 keV-140 keV. Before implementing PET attenuation correction, the intensities of CT images must be transformed into the PET 511-keV linear attenuation coefficients. However, the CT scan parameters can affect the effective energy of CT X-ray photons and thus affect the intensities of the CT image. Therefore, for PET/CT attenuation correction, it is crucial to determine the conversion curve with a given set of CT scan parameters and convert the CT image into a PET linear attenuation coefficient distribution. A generalized method is proposed for con- verting a CT image into a PET linear attenuation coefficient distribution. Instead of some parameter-dependent phantom calibration experiments, the conversion curve is calculated directly by employing the consistency conditions to yield the most consistent attenuation map with the measured PET data. The method is evaluated with phantom experiments and small animal experiments. In phantom studies, the estimated conversion curve fits the true attenuation coefficients accurately, and accurate PET attenuation maps are obtained by the estimated conversion curves and provide nearly the same correction results as the true attenuation map. In small animal studies, a more complicated attenuation distribution of the mouse is obtained successfully to remove the attenuation artifact and improve the PET image contrast efficiently.  相似文献   

7.
Omari E  Lee H  Varghese T 《Ultrasonics》2011,51(6):758-767
Quantitative ultrasound features such as the attenuation slope, sound speed and scatterer size, have been utilized to evaluate pathological variations in soft tissues such as the liver and breast. However, the impact of variations in the sound speed and backscatter due to underlying fat content or fibrotic changes, on the attenuation slope has not been addressed. Both numerical and acoustically uniform tissue-mimicking experimental phantoms are used to demonstrate the impact of sound speed variations on attenuation slope using clinical real-time ultrasound scanners equipped with linear array transducers. Radiofrequency data at center frequencies of 4 and 5 MHz are acquired for the experimental and numerical phantoms respectively. Numerical phantom sound speeds between 1480 and 1600 m/s in increments of 20 m/s for attenuation coefficients of 0.3, 0.4, 0.5, 0.6, and 0.7 dB/cm/MHz are simulated. Variations in the attenuation slope when the backscatter intensity of the sample is equal, 3 dB higher, and 3 dB lower than the reference is also evaluated. The sound speed for the experimental tissue-mimicking phantoms were 1500, 1540, 1560 and 1580 m/s respectively, with an attenuation coefficient of 0.5 dB/cm/MHz. Radiofrequency data is processed using three different attenuation estimation algorithms, i.e. the reference phantom, centroid downshift, and a hybrid method. In both numerical and experimental phantoms our results indicate a bias in attenuation slope estimates when the reference phantom sound speed is higher (overestimation) or lower (underestimation) than that of the sample. This bias is introduced via a small spectral shift in the normalized power spectra of the reference and sample with different sound speeds. The hybrid method provides the best estimation performance, especially for sample attenuation coefficient values lower than that of the reference phantom. The performance of all the methods deteriorates when the attenuation coefficient of the reference phantom is lower than that of the sample. In addition, the hybrid method is the least sensitive to sample backscatter intensity variations.  相似文献   

8.
This study was designed to measure the ultrasonic attenuation within phantoms and tissue samples over a broad bandwidth and at many angles of incidence with respect to intrinsic orientations in order to elucidate both the frequency and angular dependence of the attenuation coefficient. Significant angular dependence, or anisotropy, of the attenuation was observed in canine myocardium (maximum to minimum ratio: 2.2 to 1) and a tissue mimicking phantom of oriented graphite fibers in gelatin (max to min: 2 to 1). In control studies, insignificant anisotropy was observed in the attenuation in canine liver samples and phantoms with graphite powder suspended in gelatin. Comparisons of the magnitude of variations of the oriented-fiber phantom to that predicted by a viscous relative motion model are presented.  相似文献   

9.
Time-domain speed-of-sound (SOS) measurements in calcaneus are effective predictors of osteoporotic fracture risk. High attenuation and dispersion in bone, however, produce severe distortion of transmitted pulses that leads to ambiguity of time-domain SOS measurements. An equation to predict the effects of system parameters (center frequency and bandwidth), algorithm parameters (pulse arrival-time marker), and bone properties (attenuation coefficient and thickness) on time-domain SOS estimates is derived for media with attenuation that varies linearly with frequency. The equation is validated using data from a bone-mimicking phantom and from 30 human calcaneus samples in vitro. The data suggest that the effects of dispersion are small compared with the effects of frequency-dependent attenuation. The equation can be used to retroactively compensate data. System-related variations in SOS are shown to decrease as the pulse-arrival-time marker is moved toward the pulse center. Therefore, compared with other time-domain measures of SOS, group velocity exhibits the minimum system dependence.  相似文献   

10.
In this study the attenuation coefficient and dispersion (frequency dependence of phase velocity) are measured using a phase sensitive (piezoelectric) receiver in a phantom in which two temporally overlapping signals are detected, analogous to the fast and slow waves typically found in measurements of cancellous bone. The phantom consisted of a flat and parallel Plexiglas plate into which a step discontinuity was milled. The phase velocity and attenuation coefficient of the plate were measured using both broadband and narrowband data and were calculated using standard magnitude and phase spectroscopy techniques. The observed frequency dependence of the phase velocity and attenuation coefficient exhibit significant changes in their frequency dependences as the interrogating ultrasonic field is translated across the step discontinuity of the plate. Negative dispersion is observed at specific spatial locations of the plate at which the attenuation coefficient rises linearly with frequency, a behavior analogous to that of bone measurements reported in the literature. For all sites investigated, broadband and narrowband data (3-7 MHz) demonstrate excellent consistency. Evidence suggests that the interference between the two signals simultaneously reaching the phase sensitive piezoelectric receiver is responsible for this negative dispersion.  相似文献   

11.
郑驰超  彭虎 《声学学报》2016,41(1):25-29
为了进一步提高超声成像的质量,提出一种信号特征空间的最小方差波束形成与相关系数特征值加权相融合的超声成像算法。利用超声回波信号具有一定的相关性,而相关系数空间最大特征值可以反映回波信号相关性较强的性质,将该特征值作为自适应加权系数对信号特征空间最小方差波束形成(EIBMV)的结果进行加权成像,得到高质量的成像结果。通过对散射点目标和斑目标的Field II仿真,结果表明该算法相对于EIBMV算法,亮斑对比度提高了4.22 dB,暗斑对比度提高了1.88 dB,并且进一步提高了横向分辨率。   相似文献   

12.
提出一种测量材料超声横波衰减-频率曲线(αs-f)的方法:应用窄带脉冲驱动接触式横波探头的脉冲反射方式,采用石英晶体作为耦合块,通过测量耦合块和被测试块耦合界面的声压反射和透射系数,并在衍射修正下测量得到单频率下的超声横波衰减系数;在探头有效带宽内改变发射频率并重复测量,得到不同频率下超声横波衰减系数数值;利用非线性最...  相似文献   

13.
Purpose: The aim of this pilot study was to evaluate a magnetically labeled water perfusion imaging technique as a non-contrast-enhanced approach to demonstrate the uterine artery, its branches, and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma (FIGO IIB-IVA).Methods and Materials: Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by magnetically labeled water perfusion imaging at different inversion delay times (300–900 ms). The magnetic resonance imaging (MRI) findings of all patients were matched to the findings of contrast-enhanced dynamic MRI and multiple biopsies (n = 5) and/or surgical whole mount specimens (n = 17), which were available in all patients.Results: The uterine artery was well visualized with short inversion delay times of 300–500 ms. It was characterized as single or multiple helical loops before dividing into its intracervical branches. The intracervical branching was observed at inversion delay times of 500–700 ms. With longer inversion delay times, arterial signal enhancement disappeared and cervical tissue enhancement was noted. Enhancement of benign tissue was observed at inversion delay times of 1100–1700 ms and in malignant tissue at shorter inversion delay times of 900–1300 ms. The maximum of this diffuse signal enhancement of benign tissue was seen at inversion delay times of 1500 ms (1100-1700 ms) in malignant tissue at significantly (p < 0.5) shorter inversion delay times of 1100 ms (900–1300 ms).Conclusion: Our preliminary results show that the vascular supply and blood flow of the normal uterine cervix and of advanced cervical cancer can be assessed by magnetically labeled water perfusion imaging and that malignant cervical tissue is earlier and stronger perfused than normal cervical tissue.  相似文献   

14.
A fundamental assumption embraced in conventional use of the ultrasonic pulse-echo immersion technique to measure attenuation in solid materials is revisited. The cited assumption relies on perfect and immutable adhesion at the water to sample interface, a necessary condition that allows calculating the reflection coefficient at any interface from elastic wave propagation theory. This parameter is then used to correct the measured signal and obtain the real attenuation coefficient of the sample under scrutiny. In this paper, cases in which the perfectly cohesive interfacial condition is not satisfied are presented. It is shown also that in those cases, the repeatability of the conditions at the interface is always uncertain. This implies that the reflection coefficients are unknown, even when density is known. A new method of simultaneously measuring the reflection coefficients for both exposed interfaces that are normal to the transducer, and the attenuation coefficient of the specimen is developed and is presented here. The robustness of the new method is proven, as we demonstrate that the proper value of attenuation is achieved independently of the continuously varying interfacial conditions of these non-ideal cases.  相似文献   

15.
This study examines the extent to which ultrasonic attenuation coefficients and velocity properties change between normal and fatty rat liver. The view of this problem is toward the application in clinical medicine in the future. Fatty livers were produced in rats by feeding them alcohol diets in liquid form. The animals were sacrificed and the fat concentration of the liver specimens determined. The fat concentration varied from 2.5% to 16.8% wet weight. The ultrasonic attenuation coefficient and velocity properties in 28 specimens were measured at 100 MHz with the scanning laser acoustic microscope (SLAM). Regression analysis was applied to the liver's ultrasonic propagation properties as a function of fat concentration. The results show that the attenuation coefficient increases at a rate of 1.08 dB/mm/% fat and the velocity decreases at a rate of 2.3 m/s/% fat as the fat concentration increases.  相似文献   

16.
A theoretical expression for the variance of scatterer size estimates is derived for a modified least squares size estimator used in conjunction with a reference phantom method for backscatter coefficient measurement. A Gaussian spatial autocorrelation function is assumed. Simulations and phantom experiments were performed to verify the results for backscatter and size variances. The dependence of size estimate errors upon free experimental parameters is explored. Implications of the findings for the optimization of scatterer size estimation are discussed. The utility of scatterer size parametric imaging is examined through the signal to noise ratio comparison with standard ultrasonic B-mode imaging.  相似文献   

17.
Accurate characterization of tissue pathologies using ultrasonic attenuation is strongly dependent on the accuracy of the algorithm that is used to obtain the attenuation coefficient estimates. In this paper, computer simulations were used to compare the accuracy and the precision of the three methods that are commonly used to estimate the local ultrasonic attenuation within a region of interest (ROI) in tissue; namely, the spectral log difference method, the spectral difference method, and the hybrid method. The effects of the inhomgeneities within the ROI on the accuracy of the three algorithms were studied, and the optimal ROI size (the number of independent echoes laterally and the number of pulse lengths axially) was quantified for each method. The three algorithms were tested for when the ROI was homogeneous, the ROI had variations in scatterer number density, and the ROI had variations in effective scatterer size. The results showed that when the ROI was homogeneous, the spectral difference method had the highest accuracy and precision followed by the spectral log difference method and the hybrid method, respectively. Also, when the scatterer number density varied, the spectral difference method completely failed, while the log difference method and hybrid method still gave good results. Lastly, when the scatterer size varied, all of the methods failed.  相似文献   

18.
Experimental measurements are presented for sound wave attenuation in foam without additives (standing wave method) and in foam with added particles (pulse method). A setup is developed that makes it possible to obtain a standing sound wave in stable foam and estimate the attenuation coefficient. A comparison is made of the coefficients of sound attenuation in foam in the sonic and ultrasonic frequency ranges, which have been published in a number of works. It is shown that the introduction of particles into foam leads to an increase in sound wave attenuation and may be the result of the viscous mechanism of sound wave energy loss.  相似文献   

19.
In this article deconvolution of ultrasonic pulse-echo data acquired from attenuative layered media is considered. The problem is divided in two subproblems: treating the sparse reflection sequence caused by the layered structure of the media and treating the frequency-dependent attenuation. The first subproblem is solved by means of joint maximum a posteriori estimation of the assumed zero mean, white, nonstationary reflection sequence and its corresponding sequence of unknown standard deviations. This approach leads to an algorithm that seeks minimum entropy solutions for the reflection sequence and therefore the algorithm serves as a novel link between the classical Wiener filter and methods for sparse or minimum entropy deconvolution. The second subproblem is solved by introducing a new signal processing-oriented, linear discrete-time model for frequency-dependent attenuation in isotropic and homogeneous media. The deconvolution algorithm is tested using simulated data and its performance for real normal incidence pulse-echo data from a composite material is also demonstrated. The results show that the algorithm, in combination with the attenuation model, yields estimates that reveal the internal structure of the composite and, thus, simplify the interpretation of the ultrasonic data.  相似文献   

20.
Phase cancellation effects can compromise the integrity of ultrasonic measurements performed with phase sensitive receiving apertures. A lack of spatial coherence of the ultrasonic field incident on a phase sensitive receiving array can produce inaccuracies of the measured attenuation coefficient and phase velocity. The causal (Kramers-Kronig) link between these two quantities in the presence of phase distortion is investigated using two plastic polymer materials, Plexiglas and Lexan, that exhibit attenuation coefficients that increase linearly with frequency, in a fashion analogous to that of soft tissue. Flat and parallel plates were machined to have a step of a thickness corresponding to an integer number of half wavelengths within the bandwidth investigated, 3 to 7 MHz. Insonification of the stepped portion of each plate produces phase cancellation artifacts at the receiving aperture and, therefore, in the measured frequency dependent attenuation coefficient. Dispersion predictions using two different forms of the Kramers-Kronig relations were performed for the flat and the stepped regions of each plastic plate. Despite significant phase distortion and a detection system sensitive to these aberrations, the Kramers-Kronig link between the apparent attenuation coefficient and apparent phase velocity dispersion remains intact.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号