1.
The approach of this work was to study the capability of graphene‐based materials in the field of biological sample preparation. A polypyrrole/graphene composite was synthesized and characterized. The potential of the nanocomposite was investigated as a sorbent in dispersive solid‐phase extraction followed by high‐performance liquid chromatography with UV detection for vancomycin as a model drug. The effect of different parameters influencing extraction efficiency such as sample pH and sample volume, ionic strength, extraction time, type, and volume of desorption solvent and desorption time were investigated. A comparison study was also conducted between polypyrrole/graphene and some different novel and classic sorbents. Under optimized conditions, the calibration curve for vancomycin showed linearity in the range of 0.05–10 μg/mL. In addition, limits of detection, and quantification were 0.003 and 0.01 μg/mL, respectively. The intraday and interday relative standard deviations at a concentration of 0.05 μg/mL (n = 3) were 1.6 and 2.1%, respectively. Furthermore, the proposed method was successfully applied for the determination of vancomycin in plasma and urine samples. The relative recoveries indicated the feasibility of graphene‐based sorbents in biological sample analysis.  相似文献   

2.
A needle trap device (NTD) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from liquid samples followed by determination by gas chromatography–mass spectrometry (GC-MS). The extraction was performed using the dynamic sampling approach, in which a liquid sample was pumped through the system. Due to the flexibility and softness of graphene, its application in NTD may be difficult. Herein, the effectiveness of reduced graphene oxide (rGO) packed in NTD in dynamic extraction of PAHs was evaluated. Several experimental parameters, such as the adsorbent mass, eluent type and its volume, as well as the sample volume were optimized to achieve satisfactory performance for dynamic extraction. Comparative studies showed that the extraction performance of rGO-NTD was better than using NTDs packed with other sorbents such as activated carbon. The recovery rate for reduced graphene oxide exceeded 92%. Comparison of dynamic and headspace sampling showed comparable results but the dynamic mode is more suitable for field measurements. The recovery rates of PAHs spiked in water samples were from 76.5 to 100.2% and the relative standard deviation values were from 2.7 to 7.5% under the optimal conditions. This work reveals the potential of NTD with a graphene-based material for sample preparation before chromatographic analysis of liquid samples.  相似文献   

3.
A solid-phase extraction (SPE) using graphene as adsorbent coupled with capillary zone electrophoresis method was developed for the determination of four sulfonamide residues (sulfadimidine, sulfadimethoxine, sulfathiazole and sulfadiazine) in meat sample. Several condition parameters, such as elution solvents and volumes, sample pH and sample volume were optimized to obtain high SPE recoveries and extraction efficiency. Intra-day precisions of sulfonamides were in the range of 2.5–2.6 % and the inter-day precisions of sulfonamides were in the range of 2.6–3.4 %. Recoveries were 60.9–66.6 % for sulfadiazine and 86.1–111.4 % for other three sulfonamides in spiked meat sample. The developed method was successfully applied for the determination of sulfonamides in meat samples.  相似文献   

4.
Covalent derivatization of proteins with fluorescent dyes prior to separation is increasingly used in proteomic research. This paper examines the properties of several commercially available iodoacetamide and maleimide dyes and discusses the conditions and caveats for their use in labeling of proteomic samples. The iodoacetamide dyes BODIPY TMR cadaverine IA and BODIPY Fl C(1)-IA were highly specific for cysteine residues and showed little or no nonspecific labeling even at very high dye:thiol ratios. These dyes also showed minimal effects on pI's of standard proteins. Some iodoacetamide dyes, (5-TMRIA and eosin-5-iodoacetamide) and some maleimide dyes (ThioGlo I and Rhodamine Red C(2) maleimide) exhibited nonspecific labeling at high dye:thiol ratios. Labeling by both iodoacetamide and maleimide dyes was inhibited by tris(2-carboxyethyl)phosphine (TCEP); interactions between TCEP and dye were also observed. Thiourea, an important component of sample solubilization cocktails, inhibited labeling of proteins with iodoacetamide dyes but not with maleimide dyes. Maleimide dyes may serve as an alternative for labeling proteins where it is essential to have thiourea in the solubilization buffer. Covalent derivatization by BODIPY TMR cadaverine IA, BODIPY Fl C(1)-IA or Rhodamine Red C(2) maleimide was also demonstrated to be compatible with in-gel digestion and peptide mass fingerprinting by matrix assisted laser desorption/ionization-mass spectrometry and allowed successful protein identification.  相似文献   

5.
The graphene functionalized with (3‐aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1–100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029–0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples.  相似文献   

6.
This work presents a novel disposable electrochemical sensor for paracetamol (PCM). The sensing platform is based on graphene, manufactured via laser-scribing technology (LSG) to produce a 3D-porous structure that offers a large surface area. The analytical performances of LSG electrodes were greatly enhanced due to the high catalytic activity of graphene produced by LSG technology compared to conventional carbon electrodes. Moreover, the results showed an outstanding adsorption feature towards PCM, allowing its detection at nanomolar level from 5 nM to 100 nM through pre-concentration. The proposed sensing strategy was successfully applied for the determination of PCM in human urine samples.  相似文献   

7.
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories.  相似文献   

8.
A new method based on the combination of magnetic solid phase extraction (MSPE) and spectrofluorimetric determination was developed for isolation and preconcentration of fluoxetine form aquatic and biological samples using sodium dodecyl sulfate (SDS) coated Fe(3)O(4) nanoparticles (NPs) as a sorbent. The unique properties of Fe(3)O(4) NPs including high surface area and strong magnetism were utilized effectively in the MSPE process. Effect of different parameters influencing the extraction efficiency of fluoxetine including the amount of Fe(3)O(4) and SDS, pH value, sample volume, extraction time, desorption solvent and time were optimized. Under optimized condition, the method was successfully applied to the extraction of fluoxetine from water and urine samples and absolute recovery amount of 85%, detection limit of 20 μg L(-1) and a relative standard deviation (RSD) of 1.4% were obtained. The method linear response was over a range of 50-1000 μg L(-1) with R(2)=0.9968. The relative recovery in different aquatic and urine matrices were investigated and values of 80% to 104% were obtained. The whole procedure showed to be conveniently fast, efficient and economical for extraction of fluoxetine from environmental and biological samples.  相似文献   

9.
A solid-phase extraction procedure for Pb(II) and Cd(II) as 2,9 dimethyl-4,7-diphenyl-1,10-phenanthroline complexes on activated carbon cloth (ACC) has been established. In the determination step, flame atomic absorption spectrometry (FAAS) was used. The optimum conditions for pH, type and volume of eluent, volume of sample solution, flow rates of eluent, sample solution and matrix effect were determined. For quantitative recovery of the analyte ions, refereed optimum values are as follows: amount of ACC, 0.4 g; pH, 6.0 and eluent, 10 mL 3 M HNO3. To test the accuracy of the method, a certified reference material (CRM) analysis and add-recovery methods were performed. The developed method was applied for the determination of the analyte elements in water and vegetable samples.  相似文献   

10.
The biomonitoring of hydroxy polycyclic aromatic hydrocarbons in urine, as a direct way to access multiple exposures to polycyclic aromatic hydrocarbons, has raised great concerns due to their increasing hazardous health effects on humans. Solid‐phase extraction is an effective and useful technique to preconcentrate trace analytes from biological samples. Here, we report a novel solid‐phase extraction method using a graphene oxide incorporated monolithic syringe for the determination of six hydroxy polycyclic aromatic hydrocarbons in urine coupled with liquid chromatography‐tandem mass spectrometry. The effect of graphene oxide amount, washing solvent, eluting solvent, and its volume on the extraction performance were investigated. The fabricated monoliths gave higher adsorption efficiency and capacity than the neat polymer monolith and commercial C18 sorbent. Under the optimum conditions, the developed method provided the detection limits (S/N = 3) of 0.02–0.1 ng/mL and the linear ranges of 0.1–1500 ng/mL for six analytes in urine sample. The recoveries at three spiked levels ranged from 77.5 to 97.1%. Besides, the intra column‐to‐column (n = 3) and inter batch‐to‐batch (n = 3) precisions were ≤ 9.8%. The developed method was successfully applied for the determination of hydroxy polycyclic aromatic hydrocarbons in urine samples of coke oven workers.  相似文献   

11.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

12.
An effective, simple, and low‐cost sample preparation method based on dispersive SPE followed by GC with MS is developed for the multianalyte determination of fragrance allergens, musks, and phthalates, at sub‐ppb levels. The extraction procedure is based on a novel magnetic graphene sorbent, which is functionalized with octylamine, taking advantage of the functionalization's hydrophobic properties and π–π interactions with the analytes. Two alkyl amines, the octylamine and octadecylamine are studied to introduce alkyl chains in the basal plane of graphene. Magnetic graphene‐ octadecylamine is proved to be highly hydrophobic to such a degree that is hard to disperse in the bulk aqueous matrixes. Because of this behavior, its extraction efficiency for the target analytes is low. The synthesis and applicability of the magnetic graphene‐octylamine as more favored sorbent are optimized in terms of the most determining experimental conditions. The detection and quantification limits, which are calculated based on S/N ratio of 3 and 10, respectively, ranged from 0.29 to 3.2 ng L?1 and from 0.89 to 9.6, respectively. The dispersive SPE is successfully applied to routine analysis for the determination of the target analytes in samples from municipal treatment plant of Ioannina (Greece), from Pamvotis Lake and baby bathwater. The reproducibility of the spiked biological treatment plant water sample is evaluated and the relative standard deviation values range between 2.1 and 9.4%.  相似文献   

13.
A graphene monolithic column was fabricated in a capillary using π-electron-rich poly(N-vinylcarbazole-divinylbenzene) as the supporter through in situ one-step polymerization for the enrichment of trace benzodiazepines in biological samples. This new three-dimensional monolith showed uniformity and a continuous column bed; more importantly, it retained the unique properties of graphene that are typically associated with individual graphene sheets. Based on the large delocalized π-electron system, graphene forms ππ stacking interactions with benzodiazepines and benzene rings of poly(N-vinylcarbazole-divinylbenzene), which not only enhance the extraction performance for benzodiazepines compared to the neat polymer but also provide chemical stability of the graphene monolith. Moreover, several factors likely to affect the extraction, including ionic strength, sample pH, sample volume, and eluant volume were studied in detail. The optimized method gave a linear range of 0.005–1?ng?mL?1, and detection limits of 1.12–2.35?ng?L?1. Finally, the graphene monolith was successfully applied to the separation and enrichment of benzodiazepines from urine and hair samples coupled with high-performance liquid chromatography–mass spectrometry. The recoveries were in the range of 78.6–85.6% for urine and 87.2–94.3% for hair with relative standard deviations of 3.4–6.9 and 2.9–8.3%, respectively.  相似文献   

14.
A simple, cost-effective and efficient method was developed for the determination of glycine, gamma-aminobutyrate and taurine in rat brain using graphene as a sorbent for solid-phase extraction. The analytes were eluted from a graphene-packed solid-phase extraction cartridge with methanol, derivatized at their amino groups with the fluorescent label 4-carboxy-2,6-dimethylquinoline N-hydroxysuccinimide ester, and then separated and fluorescently detected by HPLC. The type and volume of eluent, sample pH, extraction time and sample volume were optimized with respect to sensitivity and precision. Under optimal conditions, linear response is obtained in the concentration range from 0.1 to 50?μg?g?1, with correlation coefficients of >0.990. The limits of detection are 23.4?ng?g?1 (gamma-aminobutyrate), 45.3?ng?g?1 (glycine) and 67.5?ng?g?1 (taurine) (S/N?=?3). The results reveal the potential of graphene as a sorbent in the analysis of biological samples.
Figure
Representative chromatogram of NAAs derivatives obtained in rat brain samples.  相似文献   

15.
Multiwalled carbon nanotubes functionalized by oxidation of original multiwalled carbon nanotubes with NaClO were prepared and their application as solid phase extraction sorbent for 2,4-dichlorophenoxyacetic acid (2,4-D) was investigated systemically, and a new method was developed for the determination of trace 2,4-D in water samples based on extraction and preconcentration of 2,4-D with solid phase extraction columns packed with NaClO-treated multiwalled carbon nanotubes prior to its determination by HPLC. The optimum experimental parameters for preconcentration of 2,4-D, including the column activating conditions, the amount of the sorbent, pH of the sample, elution composition, and elution volume, were investigated. The results indicated 2,4-D could be quantitatively retained by 100 mg NaClO-treated multiwalled carbon nanotubes at pH 5, and then eluted completely with 10 mL 3:1 (v/v) methanol-ammonium acetate solution (0.3 mol/L). The detection limit of this method for 2,4-D was 0.15 μg/L, and the relative standard deviation was 2.3% for fortified tap water samples and 2.5% for fortified riverine water sample at the 10 μg/L level. The method was validated using fortified tap water and riverine water samples with known amount of 2,4-D at the 0.4, 10, and 30 μg/L levels, respectively.  相似文献   

16.
A magnetically separable Fe3O4@Diaion HP-2MG composite was prepared using the coprecipitation method and the resulting magnetic Fe3O4@Diaion HP-2MG composites were used for the separation and preconcentration of trace amounts of dopamine. For the detection stage, square wave voltammetry on a disposable graphene–screen-printed carbon electrode was successfully used for the determination of dopamine. The graphene–screen-printed carbon electrode exhibited excellent electroanalytical performance for dopamine. The linear concentration range was from 0.8 to 80?µM and a detection limit of 50?nM for dopamine was obtained. In combination with the magnetic solid-phase extraction method, the sensor response was linearly proportional to the concentration of dopamine in the range of 0.01–6.0?µM with a correlation coefficient of approximately 0.9992. The detection limit of the sensor was found to be 5.0?nM by square wave voltammetry. The combined methodology was successfully applied to determine dopamine in urine samples with good recoveries ranging from 95 to 98%.  相似文献   

17.
This paper describes the use of graphene oxide/silica modified with nitro‐substituted tris(indolyl)methane as a solid‐phase extraction sorbent for the determination of organic acids. The resultant graphene oxide/silica modified with nitro‐substituted tris(indolyl)methane was characterized by FTIR spectroscopy and adsorption experiments. Solid‐phase extraction parameters such as sorbent type, sample solution pH, sample loading rate, eluent salt concentration, eluent methanol concentration, elution rate, sample loading, and elution volume were optimized. The method showed good precision, accuracy, sensitivity, and linear response for organic acids analysis over a concentration range of 1–100 μg/L for benzoic acid, p‐methoxybenzoic acid, and salicylic acid and 5–100 μg/L for the remaining organic acids (cinnamic acid, p‐chlorobenzoic acid, and p‐bromobenzoic acid) with coefficients of determination (r2) of higher than 0.9957. Limits of detection from 0.50 to 1.0 μg/L for six organic acids were achieved. The developed method was successfully applied to determine organic acids in real samples.  相似文献   

18.
In the present study, graphene oxide reinforced two‐phase electromembrane extraction (EME) coupled with gas chromatography was applied for the determination of methamphetamine as a model analyte in biological samples. The presence of graphene oxide in the hollow fiber wall can increase the effective surface area, interactions with analyte and polarity of support liquid membrane that leads to an enhancement in the analyte migration. To investigate the influence of the presence of graphene oxide in the support liquid membrane on the extraction efficiency, a comparative study was performed between graphene oxide and graphene oxide/EME methods. The extraction parameters such as type of organic solvent, pH of the donor phase, stirring speed, time, voltage, salt addition and the concentration of graphene oxide were optimized. Under the optimum conditions, the proposed microextraction technique provided low limit of detection (2.4 ng/mL), high preconcentration factor (195–198) and high relative recovery (95–98.5%). Finally, the method was successfully employed for the determination of methamphetamine in urine and hair samples.  相似文献   

19.
A novel graphene‐sensitized microporous membrane/solvent microextraction method named microporous membrane/graphene/solvent synergistic microextraction, coupled with high‐performance liquid chromatography and UV detection, was developed and introduced for the extraction and determination of three cinnamic acid derivatives in Rhizoma Typhonii. Several factors affecting performance were investigated and optimized, including the types of graphene and extraction solvent, concentration of graphene dispersed in octanol, sample phase pH, ionic strength, stirring rate, extraction time, extraction temperature, and sample volume. Under optimized conditions, the enrichment factors of cinnamic acid derivatives ranged from 75 to 269. Good linearities were obtained from 0.01 to 10 μg/mL for all analytes with regression coefficients between 0.9927 and 0.9994. The limits of quantification were <1 ng/mL, and satisfactory recoveries (99–104%) and precision (1.1–10.8%) were also achieved. The synergistic microextraction mechanism based on graphene sensitization was analyzed and described. The experimental results showed that the method was simple, sensitive, practical, and effective for the preconcentration and determination of cinnamic acid derivatives in Rhizoma Typhonii.  相似文献   

20.
冯娟娟  孙明霞  冯洋  辛绪波  丁亚丽  孙敏 《色谱》2022,40(11):953-965
样品前处理技术在样品分析中发挥着越来越重要的作用,而对分析物的富集能力和对样品基体的净化程度主要取决于高效的样品前处理材料,所以发展高性能的样品前处理材料一直是该领域的前沿研究方向。近年来,各类先进材料已经被引入样品前处理领域,发展了多种高性能的萃取材料。由于独特的物理化学性质,石墨烯已在各个研究领域获得广泛关注,在样品前处理领域也发挥着重要作用。基于高的比表面积、大的π电子结构、优异的吸附性能、丰富的官能团和易于化学改性等优点,石墨烯和氧化石墨烯基萃取材料被成功应用于各种样品的前处理,对不同领域中多种类型分析物表现出优异的萃取性能。该论文总结和讨论了近3年来石墨烯材料(石墨烯、氧化石墨烯及其功能化材料)在柱固相萃取、分散固相萃取、磁性固相萃取、搅拌棒萃取、纤维固相微萃取和管内固相微萃取等方面的研究进展。基于多种萃取机理如π-π、静电、疏水、亲水、氢键等相互作用,石墨烯萃取材料能够高效萃取和选择性富集不同类别的目标分析物,如重金属离子、多环芳烃、塑化剂、雌激素、药物分子、农药残留、兽药残留等。基于新型石墨烯萃取材料的各种样品前处理技术与多种检测技术如色谱、质谱、原子吸收光谱等联用,广泛应用于环境监测、食品安全和生化分析等领域。最后,总结了石墨烯在样品前处理领域中存在的问题,并展望了未来的发展趋势。  相似文献   