首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An aluminum electrode modified with gold atoms was introduced as a novel electrode. Gold atoms were deposited both chemically and electrochemically onto the aluminum electrode to make an aluminum/gold (Al/Au) modified electrode (ME). The experimental results showed that the Al/Au modified electrode prepared by chemical deposition, exhibits much more current than the electrochemical deposition method. The electrochemical behavior of the Al/Au modified electrode was studied by cyclic voltammometry. This modified electrode showed two pairs of peaks, a1c1 and a2c2, with surface‐confined characteristics in a 0.5 M phosphate buffer. The dependence of Epa of the second peak (a2c2) on pH shows a Nernestian behavior with a slope of 55 mV per unit pH. The effect of different supporting electrolytes, solution's pH and different scan rates on electrochemical behavior of Al/Au modified electrode was studied. Au deposited electrochemically on a Pt electrode (Pt/Au) was also used as another modified electrode. A comparative study of electrochemical behavior of bare Al, Pt/Au and Al/Au modified electrodes showed that both Pt/Au and Al/Au electrodes have the ability of electrocatalytic oxidation of S2O32?, but the electrocatalytic oxidation on the latter was better than the former. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry and chronoamperometry techniques. The average value of the rate constant for the catalytic reaction and the diffusion coefficient were evaluated by means of chronoamperometry technique.  相似文献   

2.
A self-assembled monolayer (SAM) of thiol modified chitosan (SH-CHIT), with thioglycolic acid (TGA) as a modifier to bestow thiol groups, has been prepared onto gold (Au)-coated glass plates for fabrication of the nucleic acid biosensor. The chemical modification of CHIT via TGA has been evidenced by Fourier transform infrared spectroscopy (FT-IR) studies, and the biocompatibility studies reveal that CHIT retains its biocompatible nature after chemical modification. The electrochemical studies conducted onto SH-CHIT/Au electrode reveal that thiol modification in CHIT amino end enhances the electrochemical behavior indicating that it may be attributed to delocalization of electrons in CHIT skeleton that participates in the resonance process. The carboxyl group modified end of DNA probe has been immobilized onto SH-CHIT/Au electrode using N-ethyl-N′-(3-dimethylaminopropyl)carbodimide (EDC) and N-hydroxysuccinimide (NHS) chemistry for detection of complementary, one-base mismatch and non-complementary sequence using electrochemical and optical studies for Mycobacterium tuberculosis detection. It has been found that DNA-SH-CHIT/Au bioelectrode can specifically detect 0.01 μM of target DNA concentration with sensitivity of 1.69?×?10?6 A μM?1.  相似文献   

3.
《Analytical letters》2012,45(14):2747-2757
Abstract

A novel functional electrode was obtained by implanting NH2 + into ITO film (NH2/ITO) for the first time. The NH2/ITO surface showed a better affinity to gold nanoparticles than bare ITO. Gold nanoparticles were deposited on the surface of NH2/ITO electrode (Au/NH2/ITO). The Au/NH2/ITO and NH2/ITO electrodes were used to observe the electrochemical behavior of Hemoglobin (Hb) immobilized on the electrodes surfaces. The peak current value of Hb immobilized on NH2/ITO increased compared with on bare ITO while peak current value of Hb immobilized on Au/NH2/ITO increased compared with on Au/ITO. Linkage between the ‐NH2 implanted into the ITO film and the ‐COOH of Hb was thought to be the reason for the increase of active Hb coverage on NH2/ITO compared with bare ITO. Increase of active Hb coverage on Au/NH2/ITO compare with Au/ITO was attributed to the different amount of gold nanoparticles deposited. Results showed the novel NH2/ITO and Au/NH2/ITO electrodes exhibited good stability, reproducibility besides selectivity and sensitivity. The electrode process of Hb immobilized on Au/NH2/ITO was quasi‐reversible with adsorption. The electrode reaction rate constant ks and other related constants were determined. X‐ray photoelectron spectroscopy (XPS), field‐emission scanning electron microscopy (FE‐SEM), and impedance spectra were used to characterize the different surfaces.  相似文献   

4.
《Electroanalysis》2003,15(12):1060-1066
The voltammetric behavior of methylene blue (MB) at thiol self‐assembled monolayers modified gold electrodes (SAMs/Au) has been investigated. MB exhibited a redox peak at about ?0.35 V (vs.SCE) in alkaline solution at bare gold electrodes. When the gold electrodes were modified with thiol SAMs, the peak grew due to the accumulation of MB at SAMs. With the solution pH rising, more MB was accumulated, hence the peak height increased, which differed from that at bare gold electrodes. The electrode process at SAMs/Au featured the characteristics of adsorption and/or electrode reaction controlled. The enhancing action of glutathione monolayer (GSH SAM), 3‐mercaptopropionic acid monolayer (3MPA SAM) and other thiol SAMs was compared. Among these, GSH SAM made the MB peak increase more. At GSH SAM/Au, the peak height varied linearly with MB concentration over the range of 2 μM to 400 μM. So this can be developed for the determination of MB and studies concerned. The accumulation behavior caused by GSH SAM and native fish sperm dsDNA was compared. The interaction between DNA and MB was also discussed under this condition.  相似文献   

5.
A stable quercetin–thioglycolic acid-modified gold electrode (Qu–TCA/Au) was prepared as a self-assembled monolayer (SAM) and its electrochemical behavior was investigated by electrochemical methods. In 0.05-M phosphate buffer solution (pH 7.0) quercetin exhibits quasi-reversible signals at the Qu–TCA/Au electrode. The stability of the quercetin-modified gold electrode is very good. The quercetin self-assembled monolayer is an effective mediator for the oxidation of dopamine, which was investigated by cyclic voltammetry and differential pulse voltammetry. Ascorbic acid does not interfere with determination of dopamine at an electrode modified with a mixture of quercetin–thioglycolic acid and quercetin–11-mercaptoundecanoic acid. This modification allows dopamine to be determined in the presence of ascorbic acid in the range from 3×10–5 to 3×10–4 M. The detection limit is 1×10–6 M. Scanning electrochemical microscopy (SECM) was employed to study the electrochemical performances of the modified gold electrode indicating different feedback modes at differently modified surfaces.  相似文献   

6.
《Electroanalysis》2003,15(11):987-990
The electrochemical quartz crystal impedance (EQCI) technique has been applied to investigate glucose oxidation on bare and Ni(OH)2‐modified Au electrodes in 0.2 mol L?1 KOH aqueous solution. The EQCI responses suggest different contributions of H+‐release and OH?‐incorporation reactions of the Ni(OH)2‐film redox process in 0.2 mol L?1 aqueous KOH at different potentials. Glucose adsorption on the Ni(OH)2‐modified Au electrode was studied. A mechanism for potential cyclic redox process of glucose at Ni(OH)2‐modified Au electrode is suggested, mainly based on a comparative EQCI analysis with direct glucose oxidation on bare gold and glucose ad‐/desorption on Ni(OH)2 film.  相似文献   

7.
The electrochemical behavior of cytochrome c (cyt‐c) that was electrostatically immobilized onto a self‐assembled monolayer (SAM) of captopril (capt) on a gold electrode has been investigated. Cyclic voltammetry, scanning electrochemical microscopy (SECM) and electrochemical impedance spectroscopy were employed to evaluate the blocking property of the capt SAM. SECM was used to measure the bimolecular electron transfer (ET) kinetics (kBI) between a solution‐based redox probe and the immobilized protein. In addition, the tunneling ET between the immobilized protein and the underlying gold electrode was calculated. A kBI value of (5.0±0.6)×108 mol?1 cm3 s?1 for the bimolecular ET and a standard tunneling rate constant (k0) of 46.4±0.2 s?1 for the tunneling ET have been obtained.  相似文献   

8.
《Electroanalysis》2003,15(12):1054-1059
Epinephrine (EP) could exhibit an anodic peak at a bare gold electrode, but it was very insensitive. However, when the bare gold electrode was modified with 3‐mercaptopropionic acid (3MPA) self‐assembled monolayer (3MPA SAM), the peaks of EP became more reversible and sensitive due to the accumulation and mediate efficiency of 3MPA SAM. Conditions such as solution pH, concentration of supporting electrolyte and accumulation time were optimized. Under the selected conditions (i.e., 0.02 M pH 6.8 sodium phosphate buffer, accumulation time: 2 min under open‐ circuit.), the height of the anodic peak at about 0.18 V (vs. SCE) was linear to EP concentration in the range of 2×10?7 ?1×10?6 M and 1×10?6?5×10?4 M with correlation coefficient of 0.995 and 0.999, respectively. When the 3MPA/Au was further modified with cysteamine, the interference of H2O2 and BrO3? was eliminated. But the resulting electrode still suffered from the interference of ascorbic acid. This method was used to determine the content of EP in adrenaline hydrochloride injections, and the recovery was in the range of 97.0% to 105.1%.  相似文献   

9.
《Analytical letters》2012,45(4):697-707
Abstract

The preparation of a gold electrode modified by aminylferrocene (FcAI) covalently bound to L‐cysteine self‐assembled monolayer (L‐Cys/Au SAM) was described, and characterized by cyclic voltammogram (CV) and electrochemical impedance spectroscopy (EIS). In pH 7.4 buffers, FcAI incorporated in L‐Cys/Au SAM gave a pair of well‐defined and quasi‐reversible cyclic voltammetric peaks at 0.109 vs. saturated calomel eletrode (SCE), characteristic of Fe(II)/Fe(III) redox couples of the Fc. The apparent surface electron transfer rate constant is 6.86 s?1 at the modified electrode. The immobilized Fc gave an excellent electrocatalytic activity for the oxidation of epinephrine (EP). The catalytic current of EP vs. its concentration has a good linear relation in the range of 1.7×10?7–1.0×10?4 mol/L, with the correlation coefficient of 0.9975 and detection limit of 1.8×10?8 mol/L. The modified electrode can be used for the determination of EP in practical injection. The method is simple, quick, sensitive, and accurate.  相似文献   

10.
A 4-Amino-2-mercaptopyrimidine self-assembled monolayer (AMP SAMs/Au) modified gold electrode was prepared. The electrochemical behavior of acetaminophen on the AMP SAMs/Au was studied in Britton-Robinson (BR) buffer solution. Compared to a bare gold electrode, the modified electrode exhibits a significant enhancement in the oxidation current response for acetaminophen. The modified electrode was used for the determination of acetaminophen by square wave voltammetry. The oxidation current increased linearly with the concentration of acetaminophen in the range of 2.0 × 10−6−4.0 × 10−3 M. The modified electrode made it possible to eliminate the interference of dopamine (DA), brucine, epinephrine (EP), and norepinephrine (NE). The practical analytical utility was illustrated by the determination of acetaminophen in a commercially available drug. The text was submitted by the authors in English.  相似文献   

11.
In this paper, a carbon ionic liquid electrode (CILE) was fabricated using ionic liquid 1-hexylpyridinium hexafluorophosphate as modifier, which was further in situ electrodeposited with graphene (GR) and gold nanoparticles step by step to get an Au/GR nanocomposite modified CILE. Myoglobin (Mb) was further immobilized on the Au/GR/CILE surface with Nafion film to get the modified electrode denoted as Nafion/Mb/Au/GR/CILE. Cyclic voltammetric experiments indicated that a pair of well-defined quasi-reversible redox peaks appeared in pH 3.0 phosphate buffer solution with the formal potential (E 0′) located at ?0.197 V (vs. saturated calomel electrode), which was the typical characteristics of Mb heme Fe(III)/Fe(II) redox couples. Thus, the direct electron transfer rate between Mb and the modified electrode was promoted due to the high conductivity and increased surface area of Au/GR nanocomposite present on electrode surface. Based on the cyclic voltammetric data, the electrochemical parameters of Mb on the modified electrode were calculated. The Mb-modified electrode showed excellent electrocatalytic activities towards the reduction of trichloroacetic acid and H2O2 with wider linear range and lower detection limit. Using GR and Au nanoparticles modified CILE, a new third-generation electrochemical Mb biosensor was constructed with good stability and reproducibility.  相似文献   

12.
《Electroanalysis》2006,18(11):1105-1113
We report for the first time the effective catalytic electrooxidation of nicotinamide adenine dinucleotide (NADH) on the pencil 8B‐scrawled gold electrode of an electrochemical quartz crystal microbalance (EQCM). The EQCM allowed us to quantitatively evaluate the catalytic activity of the pencil‐scrawled Au electrode. With increasing the mass of modified pencil powders, the peak potential for NADH oxidation shifted negatively, with maximum shift of ?0.35 V at saturated pencil modification; the NADH‐oxidation peak current density (jp) was also notably increased, and the jp at saturated pencil modification was found to be larger than those at conventional pencil 8B and bare Au electrodes. Sensitive amperometric detection of NADH was achieved at the gold electrode with saturated pencil modification, with low detection potential (0.4 V versus SCE), low detection limit (0.08 μmol L?1) and wide linear range (0.2–710 μmol L?1). The fluoroelectrochemical measurements of NADH at bare and pencil‐modified gold electrodes were also conducted with satisfactory results. The convenient and low‐cost modification of pencil powders on the Au electrode may have presented a new functional surface of the EQCM, which is recommended for wider applications to bioelectrochemical studies, especially in view of the EQCM's capability of providing abundant in situ information in relevant processes.  相似文献   

13.
We use colloidal Au to enhance the DNA immobilization amount on a gold electrode and ultimately lower the detection limit of our electrochemical DNA biosensor. Self-assembly of approximately 16-nm diameter colloidal Au onto a cysteamine modified gold electrode resulted in an easier attachment of an oligonucleotide with a mercaptohexyl group at the 5′-phosphate end, and therefore an increased capacity for nucleic acid detection. Quantitative results showed that the surface densities of oligonucleotides on the Au colloid modified gold electrode were approximately (1–4)×1014 molecules cm−2. Hybridization was induced by exposure of the ssDNA-containing gold electrode to ferrocenecarboxaldehyde labeled complementary ssDNA in solution. The detection limit is 5×10−10 mol l−1 of complementary ssDNA, which is much lower than our previous electrochemical DNA biosensors. The Au nanoparticle films on the Au electrode provide a novel means for ssDNA immobilization and sequence-specific DNA detection.  相似文献   

14.
The electrochemical reduction of molecular oxygen (O2) has been performed at gold electrodes modified with a submonolayer of a self-assembly (sub-SAM/Au) of a thiol compound (typically cysteine (CYST)) in O2-saturated 0.5 M KOH. At bare gold electrode O2 reduction reaction proceeds irreversibly, while this reaction is totally hindered at gold electrodes with a compact structure of CYST over its surface. The partial reductive desorption of the compact CYST monolayer was achieved by controlling the potential of the CYST/Au electrode, leading to the formation of a submonolayer coverage of the thiol compound over the Au electrode surface (sub-SAM/Au), at which the CYST molecules selectively block the Au(1 0 0) and Au(1 1 0) fractions (the so-called rough domains) of the polycrystalline Au while the Au(1 1 1) component (the so-called smooth domains) remains bare (i.e., uncovered with CYST). This sub-SAM/Au electrode extraordinarily exhibits a quasi-reversible two-electron reduction of molecular oxygen (O2) in alkaline medium with a peak separation (ΔEp) between the cathodic and anodic peak potentials (Epc,Epa) of about 60 mV. The ratio of the anodic current to the cathodic one is close to unity. The formal potential (Eo) of this reaction is found to equal −150 mV vs. Ag/AgCl/KCl(sat.).  相似文献   

15.
This paper presents a simple electrochemical approach for the detection of thrombin, using aptamer-modified electrodes. The use of gold nanoparticles results in significant signal enhancement for subsequent detection. 1,6-Hexanedithiol was used as the medium to link Au nanoparticles to a bare gold electrode. Anti-thrombin aptamers were immobilized on the gold nanoparticles’ surfaces by self-assembly. The packing density of aptamers was determined by cyclic voltammetric (CV) studies of redox cations (e.g., [Ru(NH3)6]3+) which were electrostatically bound to the DNA phosphate backbones. The results indicate that the total amount of aptamer probes immobilized on the gold nanoparticle surface is sixfold higher than that on the bare electrode, leading to increased sensitivity of the aptasensor and a detection limit of 1 pmol L−1. Based on the Langmuir model, the sensor signal displayed an almost perfect linear relationship over the range of 1 pmol L−1 to 30 nmol L−1. Moreover, the proposed aptasensor is highly selective and stable. In summary, this biosensor is simple, highly sensitive, and selective, which is beneficial to the ever-growing interest in fabricating portable bio-analytical devices with simple electrical readout procedures.  相似文献   

16.
Polythymine oligonucleotide (PTO)‐modified gold electrode (PTO/Au) was developed for selective and sensitive Hg2+ detection in aqueous solutions. This modified electrode was prepared by self‐assembly of thiolated polythymine oligonucleotide (5′‐SH‐T15‐3′) on the gold electrode via Au? S bonds, and then the surface was passivated with 1‐mercaptohexanol solution. The proposed electrode utilizes the specific binding interactions between Hg2+ and thymine to selectively capture Hg2+, thereby reducing the interference from coexistent ions. After exchanging the medium, electrochemical reduction at ?0.2 V for 60 s, voltammetric determination was performed by differential pulse voltammetry using 10 mM HEPES; pH 7.2, 1 M NaClO4 as supporting electrolyte. This electrode showed increasing voltammetric response in the range of 0.21 nM Hg2+, with a relative standard deviation of 5.32% and a practical detection limit of 60 pM. Compared with the conventional stripping approach, the modified electrode exhibits good sensitivity and selectivity, and is expected to be a new type of green electrode.  相似文献   

17.
A simple, highly sensitive and label‐free electrochemical impedance spectroscopy (EIS) immunosensor was developed using Nafion and gold nanoparticles (nano‐Au/Nafion) composites for the determination of 1‐pyrenebutyric acid (PBA). Under the optimal conditions, the amount of immobilized antibody was significantly improved on the nano‐Au/Nafion electrode due to the synergistic effect and biocompatibility of Nafion film and gold nanoparticles composites. The results showed that the sensitivity and stability of nano‐Au/Nafion composite electrode for PBA detection were much better than those of nano‐Au modified glassy carbon electrode (nano‐Au/GCE). The plot of increased electron transfer resistances (Rets) against the logarithm of PBA concentration is linear over the range from 0.1 to 150 ng·mL?1 with the detection limit of 0.03 ng·mL?1. The selectivity and accuracy of the proposed EIS immunosensor were evaluated with satisfactory results.  相似文献   

18.
《Electroanalysis》2018,30(3):533-542
A simple and highly sensitive electrochemical sensor COOH−C4 derived from dicarboxyl‐calix[4]arene modified on a screen printed gold electrode (Au) was developed for the determination of lead ions in water samples. A 3‐mercaptopropionic acid (MPA) monolayer was used as a template on the gold electrode for the surface modification with dicarboxyl‐calixarene. The modified electrodes were surface‐characterized using Fourier Transform infrared spectroscopy (FTIR). The data obtained proved the confirmation of each stage of the electrode modification. The electrochemical analyses of the COOH−C4 electrode showed an enhanced electrocatalytic activity and higher current towards Pb2+ ions as compared to the bare Au and MPA/Au electrodes. Under optimum conditions, the differential pulse voltammetry response of COOH−C4 displayed a wide linear response ranging from 280–2500 μg/L for Pb2+ with a detection limit of 6.2 μg/L. In addition, the fabricated electrode showed a high selectivity and stability towards the Pb2+ ions in presence of possible interfering species. The present method was successfully applied to determine Pb2+ ions in real samples with satisfactory precision, with a relative standard deviation of 3.12 % and an acceptable recovery of 92 %, which demonstrated the potential application of dicarboxyl‐calix[4]arene modified on electrodes for heavy‐metal sensing.  相似文献   

19.
Au/TiO2 nanorod composites with different ratios of [TiO2]:[Au] have been prepared by chemically reducing AuCl4 on the positively charged TiO2 nanorods surface and used to modify boron‐doped diamond (BDD) electrodes. The electrochemical behaviors of catechol on the bare and different Au/TiO2 nanorod composites‐modified BDD electrodes are studied. The cyclic voltammetric results indicate that these different Au/TiO2 nanorod composites‐modified BDD electrodes can enhance the electrocatalytic activity toward catechol detection, as compared with the bare BDD electrode. Among these different conditions, the Au/TiO2‐BDD3 electrode (the ratio of [TiO2]:[Au] is 27:1) is the most choice for catechol detection. The electrochemical response dependences of the Au/TiO2‐BDD3 electrode on pH of solution and the applied potential are studied. The detection limit of catechol is found to be about 1.4 × 10‐6 M in a linear range from 5 × 10‐6 M to 200 × 10‐6 M on the Au/TiO2‐BDD3 electrode.  相似文献   

20.
Molecular modeling, electrochemical methods, and quartz crystal microbalance were used to characterize immobilized hexameric tyrosine‐coordinated heme protein (HTHP) on bare carbon or on gold electrodes modified with positively and negatively charged self‐assembled monolayers (SAMs), respectively. HTHP binds to the positively charged surface but no direct electron transfer (DET) is found due to the long distance of the active sites from the electrode surfaces. At carboxyl‐terminated surfaces, the neutrally charged bottom of HTHP can bind to the SAM. For this “disc” orientation all six hemes are close to the electrode and their direct electron transfer should be efficient. HTHP on all negatively charged SAMs showed a quasi‐reversible redox behavior with rate constant ks values between 0.93 and 2.86 s?1 and apparent formal potentials ${E{{0{^{\prime }}\hfill \atop {\rm app}\hfill}}}$ between ‐131.1 and ‐249.1 mV. On the MUA/MU‐modified electrode, the maximum surface concentration corresponds to a complete monolayer of the hexameric HTHP in the disc orientation. HTHP electrostatically immobilized on negatively charged SAMs shows electrocatalysis of peroxide reduction and enzymatic oxidation of NADH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号