首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
This work was designed to develop an electrochemical sensor based on molecular imprinted polyaniline membranes onto reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) modified glassy carbon (GC) electrode for dapsone (DDS) determination. The prepared RGO/AuNPs/PANI‐MIPs nanocomposite was characterized by Ultra‐Violet‐Visible (UV‐Vis), Fourier transform infrared spectroscopy (FT‐IR) and scanning electronic microscopy (SEM) images. The feature of the imprinted electrode was evaluated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and impedance spectroscopy (IS). Throughout this study several analytical parameters, such as incubation time, pH value, concentration of monomer/template molecules and electro‐polymerization cycles were investigated. Under the optimized conditions, the experimental results showed best analytical performances for DDS detection with a sensitivity of 0.188 Ω/mol L?1, a linear range from 1.0×10?7 M to 1.0×10?3 M and a detection limit of 6.8×10?7 M. The bioanalytical sensor was applied to the determination of dapsone in real samples with high selectivity and recovery.  相似文献   

2.
A modified glassy carbon electrode was prepared as an electrochemical voltammetric sensor based on molecularly imprinted polymer film for tartrazine (TT) detection. The sensitive film was prepared by copolymerization of tartrazine and acrylamide on the carbon nanotube-modified glassy carbon electrode. The performance of the imprinted sensor was investigated by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy in detail. Under the optimum conditions, two dynamic linear ranges of 8?×?10?8 to 1?×?10?6?mol?L?1 and 1?×?10?6 to 1?×?10?5?mol?L?1 were obtained, with a detection limit of 2.74?×?10?8?mol?L?1(S/N?=?3). This sensor was used successfully for tartrazine determination in beverages.  相似文献   

3.
A new molecularly imprinted electrochemical luminescence sensor (MIP‐ECL sensor) was developed for isoproturon (IPU) determination based on the competition reaction between IPU and glucose oxidase labeled IPU (GOD‐IPU). After competition, hydrogen peroxide produced by residual GOD‐IPU on the MIP reacted with luminol to emit electrochemiluminescence (ECL) signal. The ECL intensity decreased when the GOD‐IPU molecules were replaced by IPU molecules in the samples. IPU could be determined in the concentration range from 9×10?11 mol/L to 5.1×10?9 mol/L with a detection limit of 3.78×10?12 mol/L. Water samples were assayed and recoveries ranging from 98.5 % to 102.1 % were obtained.  相似文献   

4.
Dopamine (DA) is a significant neurotransmitter in the central nervous system, coexisting with uric acid (UA) and ascorbic acid (AA). UA and AA are easily oxidizable compounds having potentials close to that of DA for electrochemical analysis, resulting in overlapping voltammetric response. In this work, a novel molecularly imprinted (MI) electrochemical sensor was proposed for selective determination of DA (in the presence of up to 80‐fold excess of UA and AA), relying on gold nanoparticles (Aunano)‐decorated glassy carbon (GC) electrode coated with poly(carbazole (Cz)‐co‐aniline (ANI)) copolymer film incorporating DA as template (DA imprinted‐GC/P(Cz‐co‐ANI)‐Aunano electrode, DA‐MIP‐Aunano electrode). The DA recognizing sensor electrode showed great electroactivity for analyte oxidation in 0.2 mol L?1 pH 7 phosphate buffer. Square wave voltammetry (SWV) was performed within 10?4–10?5 mol L?1 of DA, of which the oxidation peak potential was observed at 0.16 V. The limit of detection (LOD) and limit of quantification (LOQ) were 2.0×10?6 and 6.7×10?6 mol L?1, respectively. Binary and ternary synthetic mixtures of DA‐UA, DA‐AA and DA‐UA‐AA yielded excellent recoveries for DA. Additionally, DA was quantitatively recovered from a real sample of bovine serum spiked with DA, and determined in concentrated dopamine injection solution. The developed SWV method was statistically validated against a literature potentiodynamic method using a caffeic acid modified‐GC electrode.  相似文献   

5.
《Analytical letters》2012,45(7):1132-1144
Molecular imprinting and sol-gel technique were combined to develop a molecular imprinted polymer (MIP) based electrochemical sensor in this work. With the successive modification of multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNPs), a modified glassy carbon electrode (GCE) was immersed in a sol-gel solution in the presence of paracetamol (PR) for the electropolymerization to fabricate an imprinted sensor. Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were employed to characterize the constructed sensor. The factors for the sensor preparation, the electropolymerization potential range, the monomer concentration, and the scan rate for the sensor preparation were optimized. The sensor displayed an excellent recognition capacity toward PR compared with other analogues. Additionally, the DPV peak current was linear to the PR concentration in the range from 8.0 × 10?8 to 5.0 × 10?5 mol/L, with a detection limit of 4.0 × 10?8 mol/L. The prepared sensor also showed satisfactory reproducibility and regeneration capacity.  相似文献   

6.
This work proposes a novel biomimetic sensor for the potentiometric transduction of rivastigmine based on molecularly imprinted polymer (MIP). Using the Taguchi method, this study analyzed the optimum conditions for preparing the MIP‐based membranes. The rank order of each controllable factor was also determined. MIP‐based membranes exhibited a Nernstian response (30.7±1.1 mV decade?1) in a concentration range from 1.0×10?5 to 1.0×10?2 mol L?1 with a LOD of 6.3×10?6 mol L?1. The sensor was successfully applied to the determination of rivastigmine concentrations in human serum, plasma, urine, rat brain and tablets.  相似文献   

7.
A sensitive and selective imprinted electrochemical sensor for the determination of aflatoxin B1 (AFB1) was constructed on a glassy carbon electrode by stepwise modification of functional multiwalled carbon nanotubes (MCNTs), Au/Pt bimetallic nanoparticles (Au/PtNPs), and a thin imprinted film. The fabrication of a homogeneous porous poly o-phenylenediamine (POPD)-grafted Au/Pt bimetallic multiwalled carbon nanotubes nanocomposite film was conducted by controllable electrodepositing technology. The sensitivity of the sensor was improved greatly because of the nanocomposite functional layer; the proposed sensor exhibited excellent selectivity toward AFB1 owing to the porous molecular imprinted polymer (MIP) film. The surface morphologies of the modified electrodes were characterized using a scanning electron microscope. The performance of the imprinted sensor was investigated by cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy in detail. A linear relationship between the sensor response signal and the logarithm of AFB1 concentrations ranging from 1?×?10?10 to 1?×?10?5 mol L?1 was obtained with a detection limit of 0.03 nmol L?1. It was applied to detect AFB1 in hogwash oil successfully.  相似文献   

8.
A highly selective molecularly imprinted polymer electrochemical sensor for In3+ detection was proposed. In3+ ion was chelated with alizarin red S to form a complex In‐ARS. The complex was used as the template molecule to prepare a molecularly imprinted polymer (MIP) based sensor. The selectivity of the sensor was improved significantly due to the three‐dimensional specific structure of the complex, and the selective complexation of ligands for metal ions. Moreover, the sensitivity of the proposed sensor was improved by recording the reductive current of ligand in complex. This technique was highly sensitive for quantitative analysis of In3+ in the concentrations ranged from 1×10?8 mol/L to 2.5×10?7 mol/L with a detection limit of 4.7×10?9 mol/L. The proposed sensor has been successfully used in detecting In3+ in real samples.  相似文献   

9.
《Analytical letters》2012,45(7):1117-1131
A molecularly imprinted electrochemical sensor was fabricated based on a gold electrode modified by chitosan-multiwalled carbon nanotube composite (CS-MWCNTs) multilayer films and gold nanoparticles (AuNPs) for convenient and sensitive determination of oxytetracycline (OTC). The multilayer of CS-MWCNTs composites and AuNPs were used to augment electronic transmission and sensitivity. The molecularly imprinted polymers (MIPs) were synthesized using OTC as the template molecule and o-phenylenediamine (OPD) as the functional monomer. They were modified on a gold electrode by electropolymerization. The electrochemical behavior of OTC at the imprinted sensor was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), and amperometry. The molecularly imprinted sensor showed high selectivity and excellent stability toward OTC. The linear range was from 3.0 × 10?8 to 8.0 × 10?5 mol/L, with a limit of detection (LOD) of 2.7 × 10?8 mol/L (S/N = 3). The developed sensor showed good recovery in spiked samples analysis.  相似文献   

10.
A voltammetric paracetamol sensor based on molecularly imprinted polymeric (MIP) micelles was prepared by direct electrodeposition. The MIP micelles were prepared via macromolecule self‐assembly of an amphiphilic photocrosslinkable copolymer using paracetamol as the template molecule. The resultant molecularly imprinted polymeric micelles swelled with increasing pH, and the disassociation of the micelles occurred at pH above approximately 7.4. A robust MIP film with good solvent resistance was formed on the electrode surface by anodic electrodeposition of the MIP micelles and subsequent photocrosslinking, resulting in the fabrication of a MIP electrochemical sensor for detecting paracetamol. The resultant sensor showed good response and selectivity towards paracetamol. In addition, a wide linear range from 0.01 mmol/L to 8 mmol/L and a low detection limit of 1×10?6 mol/L for paracetamol detection was demonstrated based on this sensor. The MIP sensor also showed good stability and reversibility which was applied to determine paracetamol commercial tablets.  相似文献   

11.
A sensitive and selective electrochemical sensor based on molecularly imprinted polymers (MIPs) was developed for caffeine (CAF) recognition and detection. The sensor was constructed through the following steps: multiwalled carbon nanotubes and gold nanoparticles were first modified onto the glassy carbon electrode surface by potentiostatic deposition method successively. Subsequently, o-aminothiophenol (ATP) was assembled on the surface of the above electrode through Au–S bond before electropolymerization. During the assembled and electropolymerization processes, CAF was embedded into the poly(o-aminothiophenol) film through hydrogen bonding interaction between CAF and ATP, forming an MIP electrochemical sensor. The morphologies and properties of the sensor were characterized by scanning electron microscopy, cyclic voltammetry, and differential pulse voltammetry. The recognition and determination of the sensor were observed by measuring the changes of amperometric response of the oxidation-reduction probe, [Fe(CN)6]3?/[Fe(CN)6]4?, on modified electrode. The results demonstrated that the prepared sensor had excellent selectivity and high sensitivity for CAF, and the linear range was 5.0?×?10?10?~?1.6?×?10?7?mol?L?1 with a detection limit of 9.0?×?10?11?mol?L?1 (S/N?=?3). The sensor was also successfully employed to detect CAF in tea samples.  相似文献   

12.
《Electroanalysis》2018,30(2):320-327
A novel molecularly imprinted polymer (MIP) photoelectrochemical sensor was fabricated for the highly sensitive and selective detection of triclosan. The MIP photoelectrochemical sensor was fabricated using graphite‐like carbon nitride (g‐C3N4) and gold nanoparticles (AuNPs) as photoelectric materials. The MIP/g‐C3N4‐AuNPs sensor used photocurrent as the detection signal and was triggered by ultraviolet light (UV‐Light 365 nm). g‐C3N4‐AuNPs was immobilized on indium tin oxide electrodes to produce the photoelectrochemically responsive electrode of the MIP/g‐C3N4‐AuNPs sensor. A MIP layer of poly‐o‐phenylenediamine was electropolymerized on the g‐C3N4‐AuNPs‐modified electrode to act as the recognition element of the MIP/g‐C3N4‐AuNPs sensor and to enable the selective adsorption of triclosan to the sensor through specific binding. Under optimal experimental conditions, the designed MIP/g‐C3N4‐AuNPs sensor presented high sensitivity for triclosan with a linear range of 2×10−12 to 8×10−10 M and a limit of detection of 6.01×10−13 M. Moreover, the MIP/g‐C3N4‐AuNPs sensor showed excellent selectivity. The sensor had been successfully applied in the analysis of toothpaste samples.  相似文献   

13.
This paper reports the use of a tetracycline (TC) sensor constructed from a combination of molecularly imprinted polymer (MIP) and gold nanoparticles modified multiwall carbon nanotubes (MWNTs‐GNPs). The results demonstrated that the amount of recognition sites in the polymer was significantly increased and the electron transfer ability of the sensor was improved. The relationship between the peak current and the TC concentration was linear in the range from 0.1 to 40 mg L?1, and the detection limit was 0.04 mg L?1 (S/N=3). The peak current to TC was 4.3, 6.2 and 6.8 times larger than that of oxytetracycline, chloramphenicol and nafcillin, respectively. Thus, the combination of MIP and MWNTs‐GNPs provides a sensitive and selective electrochemical detection method for tetracycline.  相似文献   

14.
The formation of gold nanoparticle (AuNP) composites with tantalum phthalocyanines (TaPc) complexes { 1a and 1b (Figure 1 )} is reported. The TaPc‐AuNPs conjugates were characterised by atomic force microscopy (AFM) and transmission electron microscopy. The AFM analyses show that conjugates of TaPc with AuNPs are more aggregated when compared to AuNPs alone. The conjugates and TaPc complexes were immobilized on a gold electrode by drop and dry method and these were characterized by electrochemical impedance spectroscopy. The charge transfer behaviour of AuNPs was enhanced in the presence of TaPc complexes. All the modified electrodes showed electrocatalytic oxidation of bisphenol A. The limits of detection for complexes 1a and 1 b were 4.78×10?10 and 2.76×10?10 mol L?1, respectively.  相似文献   

15.
The nature of binding between Terazosin (TR) and gold nanoparticles (Au‐Nps) is investigated using UV‐vis and fluorescence spectroscopies, cyclic voltammetry, SEM, and EIS. The results suggest that Au‐Nps are effective carriers for TR. An electrochemical sensor for TR is introduced using Au‐Nps electrodeposited on carbon paste electrode. The effect of parameters including pH and scan rate on the response was investigated. A linear range from 8.0×10?9 to 5.4×10?5 mol L?1 with correlation coefficient of 0.9995 and detection limit of 1.2×10?10 mol L?1 was obtained. This sensor was used for determining TR spiked in urine, and excellent recovery results are achieved.  相似文献   

16.
Molecularly imprinted polymer (MIP) films of melamine were prepared by photopolymerization of vinylic monomers on diazonium‐modified gold electrodes. The gold‐grafted MIPs are specific and selective for melamine in either organic or aqueous media. The interferent molecules cyromazine and cyanuric acid were not recognized by the MIPs. The limit of detection was as low as 1.75×10?12 mol L?1 at S/N=3. Efficiency of melamine rebinding is related to the solubility parameter of the organic solvent or pH and ionic strength of the aqueous medium. It is concluded that diazonium salts permit to design robust electrochemical MIP sensors.  相似文献   

17.
ABSTRACT

A molecularly imprinted electrochemical sensor for the rapid detection of the anti-parasitic drug Secnidazole (SCZ) is reported. In this work, the build electrochemical sensor was based on a carbon paste electrode (CPE) modified with multi-wall carbon nanotubes (MWCNTs) and boron-embedded duplex molecularly imprinted composite membranes (B-DMICMs), that significantly increased the efficiency of the sensor for the detection of template molecule SCZ. Density functional theory (DFT) was employed to study the interactions between the template and monomers to select appropriate functional monomers for rational design of the B-DMICMs.The optimal experimental conditions were optimised for the factors affecting the performance of the sensor. Under the optimal conditions, the reduction peak currents of SCZ by differential pulse voltammetry increased linearly with SCZ concentration in the range from 3.0 × 10?4 to 1.0 × 1.0?6 mol L?1 and 1.0 × 1.0?6 to 1.91 × 10?8 mol L?1 with a detection limit of 1.72 × 10?8 mol L?1 for secnidazole, which is significantly lower than those in the currently used methods and in previous reports. This method offers low cost, sensitive and effective determination of SCZ and can potentially be used for detection of SCZ in pharmaceutical and biological samples with good precision and accuracy.  相似文献   

18.
A novel urea electrochemical sensor was constructed based on chitosan molecularly imprinted films which were prepared by potentiostatic electrodeposition of chitosan in the presence of urea followed by eluting with 0.1 M KCl. Various techniques were carried out to investigate the formation of molecularly imprinted polymer (MIP) films and the performance of the sensor. According to our expectation, the urea MIP electrochemical sensor showed excellent selectivity to urea among the structural similarities and co‐existences, high linear sensitivity to urea in the range from 1.0×10?8 to 4.0×10?5 M with a detection limit of 5.0×10?9 M. Furthermore, the recovery ranged from 96.3 % to 103.3 % and therefore offered great potential for clinical diagnosis applications.  相似文献   

19.
A molecularly imprinted polymer (MIP) based capacitive sensor for antibiotic detection in drinking water and milk has been developed on a gold coated silicon electrode (Au Electrode). The electrode was fabricated by electropolymerizing monomer resorcinol (RN) on Au surface in presence of sulphanilamide (SN) as a template molecule, to get insulated RN polymer antibiotic composite. The insulation of the polymer film was improved by incubation of electrode in 1‐Dodecanethiol solution. Subsequently MIP sensor was obtained by extraction of SN in ethanol and acetic acid solution. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) measurements were performed for characterization of the developed MIP electrode at different steps of fabrication. The surface morphology of MIP electrode was characterized using atomic force microscopy (AFM), X‐ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive x‐ray spectroscopy (EDS). Performance of MIP sensor was evaluated by measuring change in capacitance against varying concentration of SN using EIS. A linear response in the range 1 to 200 μg L?1 SN was recorded for MIP sensor with a detection limit of 0.1 μg L?1. The developed MIP sensor exhibited good selectivity towards SN in water and milk with recoveries in the range 92 % to 105 %. The obtained results suggest the usability of MIP based sensor for SN estimation in water and milk samples.  相似文献   

20.
A new voltammetric sensor based on molecularly imprinted poly(acrylic acid)‐MWCNT nanocomposite (MIP‐MWCNT) drop‐coated onto glassy carbon electrode (GCE) was developed and applied to tramadol (TR) determination in pharmaceutical samples. The voltammetric sensor prepared by suspension of MIP‐MWCNT at 1 : 1 (w/w) ratio show an improved performance compared to unmodified GCE. The electrochemical method is based on preconcentration of tramadol onto MIP‐MWCNT modified GCE surface at ?1.5 V vs Ag/AgCl for 180 s in 0.1 Britton‐Robinson buffer (pH 8.0) at stirred solution. Upon preconcentration, the differential anodic voltammogram was recorded under the optimized condition giving rise to an analytical curve varying from 9.0 up to 30.0 μmol L?1 (R2=0.997) and limits of detection and quantification of 1.4 and 4.8 μmol L?1, respectively. The method precision was assessed in terms of intraday (n=6) and interday (two consecutive days) precision, giving relative standard deviations (RSD%) values between 2.8 to 7.4 %. Excipients usually found in pharmaceutical pills (magnesium stearate, microcrystalline cellulose, starch, and silica) and paracetamol were evaluated as potential interferents, however no interference was evidenced in TR determination. The method applicability was evaluated by TR analysis in pharmaceutical samples. Moreover, the method accuracy was attested by comparison of addition and recovery assays with a reference technique (high‐performance liquid chromatography).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号